• Title/Summary/Keyword: Simple X-ray

Search Result 577, Processing Time 0.025 seconds

Microlens Fabrication Method by the Modified LICA Process (변형된 LIGA 공정을 이용한 마이크로렌즈 제작방법)

  • Lee, Sung-Keun;Lee, Kwang-Cheol;Lee, Seung-S.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2450-2456
    • /
    • 2002
  • Microlenses and microlens arrays are fabricated using a novel fabrication technology based on the exposure of a resist (usually PMMA) to deep X-rays and subsequent thermal treatment. The fabrication technology is very simple and produces microlenses and microlens arrays with good surface roughness (less than 1 nm). The molecular weight and glass transition temperature of PMMA is reduced when it is irradiated with deep X-rays. The microlenses is produced through the effects of volume change, surface tension, and reflow during thermal treatment of irradiated PMMA. The geometry of the microlens is determined by parameters such as the X-ray dose applied to the PMMA, the diameter of the microlens, along with the heating temperature, heating time, and cooling rate in the thermal treatment. Microlenses are produced with diameters ranging from 30 to 1500 ${\mu}{\textrm}{m}$. The modified LIGA process is used not only to construct hemispherical microlenses but also structures that are rectangular-shaped, star-shaped, etc.

One case report of mid-thoracic esophageal diverticulum (식도중간부 식도게실: 1 수술 치험례)

  • Sun, Kyung;Choi, Young-Ho;Chae, Sung-Soo;Kim, Hark-Jei;Kim, Hyong-Mook
    • Journal of Chest Surgery
    • /
    • v.15 no.4
    • /
    • pp.447-450
    • /
    • 1982
  • A 45 year old male officer was admitted due to upper substernal pain for 1 month, which was aggravated by swallowing. On past and family history, there was no specific history except heavy drinking. Simple chest x-ray revealed no specific abnormal findings. Preoperative esophagofiberscopy and Barium study showed midesophageal diverticulum, pulsion type, at about 2 cm below the left main bronchus. The opening of the diverticulum was located at the left posterolateral aspect of esophagus. Midesophageal false diverticulum, measuring 2 x 2 x 1 .S cm in size, was noted at about 5 cm under the aortic arch protruding through a slit-like muscular defect. After inversion of diverticular sac, interrupted sutures with 3-0 silks were done on muscular defect site, and mediastinal pleura was reinforced on the lesion with interrupted sutures. On 4th postoperative day, esophagography revealed no diverticulum or stenosis. Also esophagofiberscopy showed smooth mucosal tag without disturbance of passage. On 14th postoperative day, the patient was discharged uneventfully, and follow-up for 3 months after discharge revealed nothing abnormal symptoms. The authors report one case of midesophageal, pulsion type, false diverticulum.

  • PDF

A Minimally Invasive Rabbit Model of Progressive and Reproducible Disc Degeneration Confirmed by Radiology, Gene Expression, and Histology

  • Kwon, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.323-330
    • /
    • 2013
  • Objective : To develop a simple, reproducible model of disc degeneration in rabbits through percutaneous annular puncture and to confirm the degree of degeneration over time. Methods : Fifteen New Zealand white rabbits (4 to 5 months old and weighing approximately 3 to 3.5 kg each) underwent annular puncture of the L2-L3, L3-L4, and L4-L5 discs. Rabbits were sacrificed at 4, 8, or 20 weeks after puncture. For a longitudinal study to assess changes in disc height over time, serial X-rays were performed at 0, 2, 4, 8, and 20 weeks for rabbits in the 20-week group. Upon sacrifice, the whole spinal column and discs were extracted and analyzed with magnetic resonance imaging (MRI), real time reverse transcriptase-polymerase chain reaction, and histological staining. Results : The X-rays showed a slow, progressive decrease in disc height over time. Significant disc space narrowing compared to preoperative disc height was observed during the time period (p<0.001). The MRI grade, aggrecan, and matrix metalloprotease-13 mRNA expression and hematoxylin and eosin/safranin O/anti-collagen II staining were consistently indicative of degeneration, supporting the results of the X-ray data. Conclusion : Percutaneous annular puncture resulted in slow, reproducible disc degeneration that was confirmed by radiology, biochemistry, and histology. This in vivo model can be used to study and evaluate the safety and efficacy of biologic treatments for degenerative disc disease.

Gene Expression Biodosimetry: Quantitative Assessment of Radiation Dose with Total Body Exposure of Rats

  • Saberi, Alihossein;Khodamoradi, Ehsan;Birgani, Mohammad Javad Tahmasebi;Makvandi, Manoochehr
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8553-8557
    • /
    • 2016
  • Background: Accurate dose assessment and correct identification of irradiated from non-irradiated people are goals of biological dosimetry in radiation accidents. Objectives: Changes in the FDXR and the RAD51 gene expression (GE) levels were here analyzed in response to total body exposure (TBE) to a 6 MV x-ray beam in rats. We determined the accuracy for absolute quantification of GE to predict the dose at 24 hours. Materials and Methods: For this in vivo experimental study, using simple randomized sampling, peripheral blood samples were collected from a total of 20 Wistar rats at 24 hours following exposure of total body to 6 MV X-ray beam energy with doses (0.2, 0.5, 2 and 4 Gy) for TBE in Linac Varian 2100C/D (Varian, USA) in Golestan Hospital, in Ahvaz, Iran. Also, 9 rats was irradiated with a 6MV X-ray beam at doses of 1, 2, 3 Gy in 6MV energy as a validation group. A sham group was also included. After RNA extraction and DNA synthesis, GE changes were measured by the QRT-PCR technique and an absolute quantification strategy by taqman methodology in peripheral blood from rats. ROC analysis was used to distinguish irradiated from non-irradiated samples (qualitative dose assessment) at a dose of 2 Gy. Results: The best fits for mean of responses were polynomial equations with a R2 of 0.98 and 0.90 (for FDXR and RAD51 dose response curves, respectively). Dose response of the FDXR gene produced a better mean dose estimation of irradiated "validation" samples compared to the RAD51 gene at doses of 1, 2 and 3 Gy. FDXR gene expression separated the irradiated rats from controls with a sensitivity, specificity and accuracy of 87.5%, 83.5% and 81.3%, respectively, 24 hours after dose of 2 Gy. These values were significantly (p<0.05) higher than the 75%, 75% and 75%, respectively, obtained using gene expression of RAD51 analysis at a dose of 2 Gy. Conclusions: Collectively, these data suggest that absolute quantification by gel purified quantitative RT-PCR can be used to measure the mRNA copies for GE biodosimetry studies at comparable accuracy to similar methods. In the case of TBE with 6MV energy, FDXR gene expression analysis is more precise than that with RAD51 for quantitative and qualitative dose assessment.

A Study on the Accuracy and Convenience of Imaging Method Using Support Device in Knee Joint Lateral Radiography (슬관절의 측면 방사선 촬영에서 보조기구를 이용한 검사방법의 정확성과 편의성에 대한 연구)

  • Uhm, Soyeong;Cho, Yongkeun;Kang, Sungjin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.253-262
    • /
    • 2017
  • In lateral projection imaging method of knee joint, a method that adjusts the incidence angle of central X-ray toward the head side to $5{\sim}7^{\circ}$ in true lateral position which is existing recommended is called imaging method A, Method of imaging the central X-ray perpendicular to the horizontal plane of the examination table toward the knee is called imaging method B, and a method in which the central X-ray is perpendicularly applied to the joints while the lateral side of the distal tibia is compensated by radiolucent materials is called as method C. After tests each imaging method to classified study subject respectively, the joint space distance and the distance between lateral and medial condyle of femur were measured and compared as the quantitative index from the three imaging methods. In addition, the convenience of each imaging method was confirmed through questionnaires to practician. According to the result of the quantitative index, there is no statistically significant difference in imaging method A and C(p>0.05). However, imaging method B showed a significant difference in both A and C(p<0.05). As a result of evaluating the convenience of the imaging method, imaging method A was relatively assessed lower in all items than imaging methods B and C, and as a small difference, imaging method B is assessed higher than C. In this study suggested new knee joint lateral projection imaging method, by using a simple support device, could describe joint space as not much different as existing recommended method without some complex process, and could increase convenience of the practician in the process of the imaging.

Evaluation of Lead levels in Airborne by a portable X-Ray Fluorescence Instrument (휴대용 X-Ray 형광기기(XRF)를 이용한 공기중 납농도 평가)

  • Ahn, Kyu Dong;Lee, Jong Chun;Cho, Kwang Sung;Kim, Nam Su;Kim, Jin Ho;Lee, Sung Soo;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.235-240
    • /
    • 2001
  • This study was performed to compare the lead levels of 20 quality control standard samples(KOSHA:18-2000) and 72 field samples in lead-acid battery manufacturing plant between ICP and portable-XRF methods. 1. While the proficiencies of 20 quality control standard samples by ICP were 100%, those of analytic result values by XRF were 75%. 2. The correlation coefficient(r) between the reference values for quality control (REF) and the analytic result values by ICP (ICP) was 1.0(p<0.05), and simple linear regression equation and the coefficient(R2) were REF = -0.0009 + 1.016 ICP and 0.9997, respectively. 3. The correlation coefficient(r) between the analytic result values of quality control standard samples by ICP (ICP) and by XRF (XRF) was 0.975(p<0.05), and simple linear regression equation and the coefficient(R2) were ICP = -0.0003 + 1.002 XRF and 0.950, respectively. 4. The correlation coefficient(r) between the analytic result values for lead samples of a lead-acid battery manufacturing plant by ICP (ICP) and by XRF (XRF) was 0.993(p<0.05), and simple linear regression equation and the coefficient(R2) were ICP = -2.058 + 0.996 XRF and 0.987, respectively. 5. While the frequency distributions of XRF /ICP(Ratio) for each ICP concentration levels in a lead-acid battery manufacturing plant revealed high proportion in ratio range of 0.876-1.125 than in ration range of 1.126-1.375. Also, ICP concentration level in ration range of 0.786-1.125 was increased with increase of frequency distribution of XRF/ICP. 6. The limit of detection of XRF on lead was determined to be $6.11{\mu}g$/filter The data presented in this study indicated that relationship for lead level of quality control samples and field samples in a lead -acid battery manufacturing plant by ICP and portable-XRF methods was proved. The practicing industrial hygienist can use portable-XRF to produce a rapid on-site determination of lead exposure that can immediately becommunicated to workers and help identify appropriate levels of personal protection.

  • PDF

A K-Ray Image Reconstruction by the Direct Detection Method (직접검출방식(直接檢出方式)에 의한 X선영상(X線影像)의 재구성(再構成)에 관(關)한 연구(硏究))

  • Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.14 no.1
    • /
    • pp.61-72
    • /
    • 1991
  • In this paper, the rotating plate method extracting signal and reconstructing original image was proposed. The rotating methode has cell detector array each of which has used in the medical diagnosis X-ray photography. The major problem using the simple horizontal moving or non-moving methode is the size and number of detector cells which have the considerable affection on the sharpness and resolution of the reconstructed image. Secondary, the estimated pixel values of non-detected real points which are placed between detector cells will be the distorted pixels in the reconstructed image. Therefore, the proposed rotating plate method has the exact distribution on the uncertain pixels which were reconstructed by conventional methods to solve there problems. And then, the image using the rotated plate's cell out put signal was reconstructed on the computer simulation. The method will rotated the detector array plate to solve the reconstruction from the detector size and number of conventional methods. The result of simulation has estimated the original pixel position and 81 pixel/mm resolution which the reconsiderlation of the detector's moving orientation, the proposed method has 25 pixel/mm resolution. These results have been represented by 3-D computer graphics.

  • PDF

An ionization Chamber for a Steel Sheet Thickness Measurement

  • Kim, Han-Soo;Park, Se-Hwa;Kim, Yong-Kyun;Ha, Jang-Ho;Cho, Seung-Yeon
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.149-153
    • /
    • 2006
  • An ionization chamber is still widely used in many fields by virtue of its' simple operational characteristics and the possibility of its' various shapes. A parallel type of an ionization chamber for a steel sheet thickness measurement was designed and fabricated. High pure xenon gas, which was pressurized up to 6 atm, was chosen as a filling gas to increase the current response and sensitivity for a radiation. A high pressure gas system was also constructed. The active volume and the incident window size of the fabricated ionization chamber were $30\;cm^3\;and\;12\;cm^2$, respectively. Preliminary tests with a 25 mCi $^{241}Am$ gamma-ray source and evaluation tests in a standard X-ray field were performed. The optimal operation voltage was set from the results of the collection efficiency calculation by using an experimental two-voltage method. Linearity for a variation of the steel sheet thickness, which is the most important factor for an application during a steel sheet thickness measurement, was 0.989 in this study.

Fabrication and Improved Sensitivity with Surface Treatment of TiO2/GOD Mixture based Glucose Biosensor (TiO2/GOD 혼합물 기반의 글루코스 바이오 센서의 제작과 표면 처리를 통한 감도개선)

  • Lee, Junyeop;Jung, Dong Geon;Lee, Jae Yong;Kim, Jae Keon;Jung, Daewoong;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.170-174
    • /
    • 2018
  • In this paper, the $TiO_2$/glucose oxidase (GOD) mixture has synthesized through simple and low-cost fabrication methods. The physical properties of the mixture were proved using an FT-IR/NIR spectrometer, an X-Ray diffractometer, and a Raman spectrometer. GOD maintained its bioactivity during all fabrication process. The current characteristics of the glucose biosensor were proportional to the glucose concentration and effective surface area of square pyramid on a silicon substrate. The maximum current change was measured in a pH 7.0 buffer solution. The simple and low-cost fabrication process and surface treatment can be used widely in previous research for improvements in effective surface area.

Thoracoscopic Removal of an Intrapulmonary Sewing Needle - A case report - (폐실질 내 바늘의 흉강경을 통한 수술적 제거 - 1예 보고 -)

  • Yu, Jeong-Hwan;Kang, Shin-Kwang;Na, Myung-Hoon;Lim, Seung-Pyung;Lee, Young;Yu, Jae-Hyeon
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.798-801
    • /
    • 2007
  • A 24 year old man visited our hospital, because an intrapulmonary foreign body had been found incidentally. Simple chest X-ray showed a 5 cm sized foreign body of metallic density, and chest CT confirmed the foreign body, which was like a sewing needle, in the left upper lobe. We performed a simple extraction of the foreign body using VATS (Video Assisted Thoracic Surgery). After the operation, the patient was discharged without any complications.