Thoracoscopic Removal of an Intrapulmonary Sewing Needle - A case report -

폐실질 내 바늘의 흉강경을 통한 수술적 제거 - 1예 보고 -

  • Yu, Jeong-Hwan (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Chungnam National University) ;
  • Kang, Shin-Kwang (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Chungnam National University) ;
  • Na, Myung-Hoon (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Chungnam National University) ;
  • Lim, Seung-Pyung (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Chungnam National University) ;
  • Lee, Young (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Chungnam National University) ;
  • Yu, Jae-Hyeon (Department of Thoracic and Cardiovascular Surgery, College of Medicine, Chungnam National University)
  • 유정환 (충남대학교 의과대학 흉부외과학교실) ;
  • 강신광 (충남대학교 의과대학 흉부외과학교실) ;
  • 나명훈 (충남대학교 의과대학 흉부외과학교실) ;
  • 임승평 (충남대학교 의과대학 흉부외과학교실) ;
  • 이영 (충남대학교 의과대학 흉부외과학교실) ;
  • 유재현 (충남대학교 의과대학 흉부외과학교실)
  • Published : 2007.11.05

Abstract

A 24 year old man visited our hospital, because an intrapulmonary foreign body had been found incidentally. Simple chest X-ray showed a 5 cm sized foreign body of metallic density, and chest CT confirmed the foreign body, which was like a sewing needle, in the left upper lobe. We performed a simple extraction of the foreign body using VATS (Video Assisted Thoracic Surgery). After the operation, the patient was discharged without any complications.

24세 남자가 우연히 발견된 폐실질 내 이물로 내원하였다. 단순흉부촬영상 약 5 cm크기의 금속성물질로 보였고, 흉부단층촬영에서 좌하엽폐야에 바느질 바늘로 추정되는 이물이 발견되었다. 수술은 흉강경을 이용하여 바늘을 제거하였다. 수술 후 환자는 특별한 경과나 합병증 없이 퇴원하였다. 이에 저자들은 폐실질 내 이물의 흉강경적 제거를 치험하였기에 문헌고찰과 함께 보고한다.

Keywords

References

  1. Park SS, Kang SK, Ku KW, et al. Intrathoracic migration of Steinmann pin: report of a case. Korean J Thorac Cardiovasc Surg 2001;34:511-3
  2. Ko MS, Lee S, Park KS. Surgical management for incidental finding of an intrapulmonary foreign body: report of a case. Korean J Thorac Cardiovasc Surg 2006;39:248-50
  3. Miura H, Taira O, Hiraguri S, Hirata T, Kato H. Successful surgical removal of an intrapulmonary aberrant needle under fluoroscopic guidance: report of a case. Surg Today 2001;31:55-8 https://doi.org/10.1007/s005950170221
  4. Venissac N, Alifano M, Dahan M, Mouroux J. Intrathoracic migration of Kirschner pins. Ann Thorac Surg 2000;69:1953-5 https://doi.org/10.1016/S0003-4975(00)01198-X
  5. Calkins CM, Moore EE, Johnson JL, Smith WR. Removal of an intrathoracic migrated fixation pin by thoracoscopy. Ann Thorac Surg 2001;71:368-70 https://doi.org/10.1016/S0003-4975(00)01722-7
  6. Bartek JP, Grasch A, Hazelrigg SR. Thoracoscopic retrieval of foreign bodies after penetrating chest trauma. Ann Thorac Surg 1997;63:327-33 https://doi.org/10.1016/S0003-4975(96)00960-5
  7. Lang-Lazdunski L, Mouroux J, Pons F, et al. Role of videothoracoscopy in chest trauma. Ann Thorac Surg 1997;63:327-33 https://doi.org/10.1016/S0003-4975(96)00960-5