• Title/Summary/Keyword: Simple X-ray

Search Result 574, Processing Time 0.025 seconds

A pilot study of half-value layer measurements using a semiconductor dosimeter for intraoral radiography

  • Shun Nouchi;Hidenori Yoshida;Yusaku Miki;Yasuhito Tezuka;Ruri Ogawa;Ichiro Ogura
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.217-220
    • /
    • 2023
  • Purpose: This pilot study was conducted to evaluate half-value layer (HVL) measurements obtained using a semiconductor dosimeter for intraoral radiography. Materials and Methods: This study included 8 aluminum plates, 4 of which were low-purity (less than 99.9%) and 4 high-purity (greater than 99.9%). Intraoral radiography was performed using an intraoral X-ray unit in accordance with the dental protocol at the authors' affiliated hospital: tube voltage, 60 kVp and 70 kVp; tube current, 7 mA; and exposure time, 0.10 s. The accuracy of HVL measurements for intraoral radiography was assessed using a semiconductor dosimeter. A simple regression analysis was performed to compare the aluminum plate thickness and HVL in relation to the tube voltage (60 kVp and 70 kVp) and aluminum purity (low and high). Results: For the low-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the thickness of the aluminum plate (X), with Y=1.708+0.415X (r=0.999, P<0.05) and Y=1.980+0.484X (r=0.999, P<0.05), respectively. Similarly, for the high-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the plate thickness(X), with Y=1.696+0.454X (r=0.999, P<0.05) and Y=1.968+0.515X (r=0.998, P<0.05), respectively. Conclusion: This pilot study examined the relationship between aluminum plate thickness and HVL measurements using a semiconductor dosimeter for intraoral radiography. Semiconductor dosimeters may prove useful in HVL measurement for purposes such as quality assurance in dental X-ray imaging.

Survey of the Musculoskeletal Disorders of Riot Police and Conscripted Policeman in Radiologic Examination (전.의경의 방사선 검사를 통한 근골격계 질환 현황 조사)

  • Cho, Jae-Hwan;Kang, Maeng-Jin;Seok, Jong-Min;Jeun, Sung-Joon;Lim, Youn-Shik;Jeong, Jae-Kyo;Kim, Hyeon-Ju;Ju, Myeong-Shik;Dong, Kyung-Rae;Park, Cheol-Soo;Lee, Jin;Lee, Hae-Kag
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.315-324
    • /
    • 2011
  • The purpose of this study was to use as basic data for the is systematic and efficient facility inventory of policeman and the riot police, conscripted policeman. First, the analysis was performed for the patient implementing the simple x-ray, CT, and MRI examination to the policeman and the riot police, conscripted policeman within the radiologic examination. As to the classification by disease, it classified into the partial body as the common disease and musculoskeletal system disease. As to the fixed quantity comparison of the policeman and the riot police, conscripted policeman the basic X-ray, CT, MRI examination by part average personnel was compared. As to the research result the riot police, conscripted policeman, the Lower extremity examination occupies the simple X-ray, CT, and MRI examination in comparison with the other part altogether much and particularly, the Knee examination ratio occupies much among the Lower extremity examination.

Clinical Features and Outcomes of Pelvic Insufficiency Fractures (골반 부전 골절의 임상 양상과 치료 결과)

  • Seo, Yong Min;Kim, Young Chang;Kim, Ji Wan
    • Journal of the Korean Fracture Society
    • /
    • v.30 no.4
    • /
    • pp.186-191
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the radiological and epidemiological characteristics, as well as the clinical course of pelvic insufficiency fractures in the elderly population. Materials and Methods: At a Haeundae Paik Hospital, we retrospectively reviewed patients with pelvic insufficiency fractures between March 2010 and May 2017. The demographic data of patients were analyzed, and bone mineral density and bone turnover markers were evaluated to estimate the metabolic status of the bone. The radiological characteristics were evaluated by comparing the simple x-ray images with the computed tomography images, and the types of fractures were classified via computed tomography images. For clinical course evaluation, we investigated comorbid complications, and compared the walking ability scale before and 6 months after the fracture. Results: A total of 42 patients were included, with an average age of 76.5 years. All were female except one case. In 5 cases where the initial medical examination was from another institution, the fracture was not found in 3 cases. All cases received conservative treatment. After the diagnosis of pelvic bone fracture using a simple x-ray imaging, additional fractures were found in 81.0% of the study population using a computed tomography. Initiation of gait occurred at an average of 2.8 weeks, and every case except 1 (97.6%) fully recovered their gait ability. Conclusion: We concluded that there was a limitation with diagnosing pelvic insufficiency fracture using only a simple x-ray imaging technique. In general, cases in this study showed conservative treatment yielded favorable clinical outcome with relatively less critical complications.

The Crystallographic and Magnetic Properties of $Fe_{1-x}Co_x$System ($Fe_{1-x}Co_x$계의 결정구조와 자기적인 성질)

  • 김정기;한경훈;서정철
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.4
    • /
    • pp.190-195
    • /
    • 1999
  • The crystallographic and magnetic properties of the system of $Fe_{1-x}Co_x$(x=0.2 and 0.4) prepared by microwave arc-melting with the maximum power of 3.5 kW and a iron-foil with thickness of 25 ${\mu}{\textrm}{m}$ have been studied by the methods of X-ray diffraction and the measurement of the magnetic hysteresis using the vibrating sample magnetometer at room temperature. The samples were prepared in three different ways: First, pellet form pressed under the pressure of 9,000 N/$\textrm{cm}^2$. Second, the sheet cold rolled. Third, thin sheet treated with the temperature of 90$0^{\circ}C$. The X-ray diffraction pattern of the sample prepared by the first method shows that the crystal structure of the sample is bcc as same as that of Fe with a good uniformity. The iron-foil has the coercivity of 43 Oe and the initial slope of magnetization of 0.328 emu/gOe. The coervicity and magnetization of the sample prepared by the second method increased as the Co content increased. But the initial slop of the magnetization decreased as the Co content increased. This means that the displacement of domain wall is suppressed by the increases of coercivity as the Co content increased. The saturation magnetization of the samples made by the third method increased. On the other hand, the coercivity of these samples decreased. The increase of saturation magnetization of the samples seems to be related to the changes in X-ray intensity after heat treatment. Also some magnetic parameters of the samples were calculated by using a simple model and compared with other values.

  • PDF

Surgical Treatment of Congenital Cystic Adenomatoid Malformation; 1 Case Report (선천성 낭종성 기형의 외과적치료;1례 보고)

  • Lee, Jeong-Hui;Im, Jin-Su;Choe, Hyeong-Ho
    • Journal of Chest Surgery
    • /
    • v.26 no.4
    • /
    • pp.320-324
    • /
    • 1993
  • Congenital cystic adenomatoid malformation [CCAM] of the lung is extremely rare. The patient was 10 year old female and had no specipic signs and symptoms except right lower chest pain for 5 days ago before admission.On simple chest X-ray and thoracic CT scan, about 9x8x8cm sized, heterogenous marginal enhanced multiseparated hypodence lesion with air fluid level and gas bubbles in posterior pleural space in right lower chest .The culture result of needle aspiration of cavity was apergillus flavus. Right lower lobectomy was carried out and the result of biopsy was congenital cystic adenomatoid malformation.

  • PDF

A Gastroesophageal Cyst in the Posterior Mediastinum; A Report of Case (후종격동에 발생한 위식도 낭종)

  • 신화균
    • Journal of Chest Surgery
    • /
    • v.26 no.9
    • /
    • pp.738-742
    • /
    • 1993
  • The gastroesophageal cyst is rare variety of benign developmental cysts in the mediastinum and it arises from sequestrations of nodules of forgut in the developing embryo.The patient was 23 year old man with complaint of right chest pain. Simple chest X-ray and chest CT scan showed a huge homogeneous cystic mass in the posterior mediastinum. The resected cystic mass showed combining of portion of esophagus and stomach. The cyst was confirmed as gastroesophageal cyst.

  • PDF

Pulmonary Blastoma -A Case Report- (폐아세포종 -수술치험 1례-)

  • 금동윤
    • Journal of Chest Surgery
    • /
    • v.27 no.10
    • /
    • pp.868-873
    • /
    • 1994
  • We experienced a very rare case of pulmonary blastoma in a 29 year old female. She complained of left chest pain and dyspnea for 1 month. The characteristic feature of this tumor is it`s biphasic pattern consisting of a spindle cell stroma containing glandular structures. A serial check of simple chest X-ray and computed tomography revealed a growing huge lung mass occupying whole left thorax. We successfully removed the upper lobe of left lung with a huge tumor mass. Pathologic study revealed this tumor as pulmonary blastoma. We report a case with review of literature.

  • PDF

Partial Anormalous Pulmonary Venous Return with Scimitar Sign (Scimitar 징후를 동반한 부분폐정맥환류이상 -1례보고-)

  • 권종범
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.827-829
    • /
    • 2000
  • We experienced a case of partial anomalous pulmonary venous return from righ lung to inferior vena cava, which combined with Scimitar sign in 18 years old female patient. Diagnostic procedures were simple chest x-ray chest CT, and cardiac catheterization. We redirected the anomalous venous flow from inferior vena cava to left atrium through the intracardiac tunnel which was made with autologous pericardium. Postoperative course was not eventful.

  • PDF

Simple Algorithm of Structure Features Extration for Stereo Image Matching (스테레오 영상 정합을 위한 새로운 구조 정보 추출 알고리즘)

  • 최환언
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.9 no.1
    • /
    • pp.1-11
    • /
    • 1991
  • In this reseach, double-layered photoconductor consist of the carrier generation layer(CGL) of $\varepsilon$ type copper phthalocyanine thin film by an aqueous coating method and the carrier transport layer(CGL) of polyvinyl carbazol(PVK) by spin coating. We inverstigated effect of the surfactant solution and cathod electrolysis to the crystal type of $\varepsilon$-CuPc in CGL with TEM, SEM and X- ray diffraction spectroscopy and studied the mechanism of an aqueous coating for the preparation of CGL. The effect of the washing of CGL about the electrophotographic characteristics of the $\varepsilon$-CuPc/PVK doublelayered photoconductors is studied also.

  • PDF

Esophageal Perforation Predisposed by Cervical Spur - 1 Case Report - (식도천공 -1례 보고-)

  • 고태환
    • Journal of Chest Surgery
    • /
    • v.22 no.5
    • /
    • pp.873-879
    • /
    • 1989
  • The 50-year-old female patient was admitted to our hospital because of dysphagia and foreign body sensation on the neck after swallowing of solid foods 5 days ago. Esophagoscopic findings, performed on 2 days prior to admission, revealed no pathology. She had no history of preexisting esophageal disease. Under the diagnosis of the cervical esophageal perforation by routine studies such as simple chest, neck x-ray films and clinical findings, incision and drainage on the retropharyngeal space was done. Postoperatively we found the protruded degenerative spur on the 5th and 6th cervical vertebral bodies, and we considered that esophageal perforation in this case was predisposed by cervical spur. The postoperative course was uneventful.

  • PDF