• 제목/요약/키워드: Silver ion

검색결과 263건 처리시간 0.022초

Preparation and Investigation on Swelling and Drug Delivery Properties of a Novel Silver/Salep-g-Poly(Acrylic Acid) Nanocomposite Hydrogel

  • Bardajee, Ghasem Rezanejade;Hooshyar, Zari;Kabiri, Firozeh
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권8호
    • /
    • pp.2635-2641
    • /
    • 2012
  • Novel silver/salep-g-poly(acrylic acid) nanocomposite hydrogel were prepared in aqueous solution using poly(acrylic acid) grafted onto salep as a biopolymer based material. FT-IR spectra confirmed that poly(acrylic acid) (PAA) had been grafted onto salep in graft copolymerization reaction. TEM observations showed that silver nanoparticles have been uniformly dispersed in polymeric matrix. Effects of pH, acrylic acid (AA) amount and silver ion concentration on swelling capabilities were investigated. Results indicate that modifying AA and silver ion can improve swelling properties of the resultant nanocomposite hydrogel. pH response of this nanocomposite hydrogel in acidic and neutral pH made it suitable for drug delivery applications.

PET위 Silver Catalyst를 이용한 무전해 구리 도금 대안 공정 (Alternative Eletroless Copper Plating Process Utilizing Silver Catalyst on Poly(Ethylene Terephthalate))

  • 이홍기;허진영;임영생;이건형
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2014년도 추계학술대회 논문집
    • /
    • pp.127-128
    • /
    • 2014
  • 현재 기술 산업에서 PET위 무전해 도금을 실행하기 위해 다양한 전처리 공정과 Catalyst가 소개되고 있다. 그 중에서 가장 일반적으로 사용되고 있는 Catalyst는 Palladium으로서 Tin과 산화 환원 반응으로 Electroless Copper Deposition 단계에서 구리 도금의 Target으로 작용하고 있다. 하지만 상대적으로 Palladium은 생산 비용이 높으며 Tin은 쉽게 산화되는 문제점이 남아 있다. 이를 대체하기 위한 대안 공정으로서 Palladium 대신 Silver를 이용하여 Catalyst로서의 역할을 하는 공정이다. 이전에 PET위 전처리 공정으로 Ultra Violet을 사용하여 표면을 개질 시키는 방법을 연구했으며, 그 후 Potassium Permanganate와 Silver Catalyst의 Mechanism을 연구 했다. PET 표면 개질을 거치면서 화학 구조가 바뀌어 표면에 Carbon Carbon Double Bond를 형성한다. 이때 Permanganate ion이 새로이 형성된 이중 결합과 반응하여 두 개의 extra-OH functional group을 생성함과 동시에 $MnO_2$를 만들어 표면에 흡착 시킨다. $MnO_2$는 전위차에 의해 Silver Ion과 Redox Reaction을 일으키며 실질적인 Catalyst 역할을 하게 된다. Silver Catalyst는 무전해 구리 도금 용액 안에서 Copper의 Target으로 작용한다.

  • PDF

패각분말을 이용한 살균성 메디아의 제조 및 정수기용 필터에 대한 응용 (Manufacture of Sterilizing Media with Shell Powder and It's Application to the Filter of Water Clarifier)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제15권11호
    • /
    • pp.1027-1034
    • /
    • 2006
  • Antimicrobial powder was made by exchanging silver ion on calcined oyster shell. On the purpose of application to water clarifier, bail-type media mixed with antimicrobial powder and $0{\sim}30%$ white kaoline were made. The sterilization effect, pore size distribution and zeta potential was tested to indicate the condition for the media of water clarifier. From these tests, it was confirmed that this media have an excellent sterilization power on $G^-\;and\;G^+$ germs. As the concentration of the exchanged silver ion increased, the surface charge density of the anions on the surface of the media also increased. The surface pore size decreased with the concentration of silver ion and 20% more white kaoline ratio. Consequently, mixing ratio of white kaoline would appear to indicate the optimun condition as media have sterilization power.

초음속 유동에서 코로나 방전을 이용한 금속 나노 입자의 생성 (Metallic Nano Particle Generation by Supersonic Nozzle with Corona Discharge)

  • 정재희;박형호;김상수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1510-1515
    • /
    • 2004
  • The effects of additive ions on the generation of metallic nanoparticles were evaluated using a corona induced supersonic nozzle. Applying the corona discharge to the nanoparticle generator, a tungsten needle and the supersonic nozzle are used as an anode electrode and a cathode electrode respectively. The corona ions act as nuclei for the silver vapor condensation. The ion density was controlled precisely as varying the applied voltage between electrode and nozzle. The mean diameter of the silver particle decreases as the ion density increases. However, the number concentration of the silver particle tended to increase with the ion density. The size distribution is more uniform as the ion density increases.

  • PDF

임상형 유방염을 가진 홀스테인(Holstein) 소에 대한 은 이온의 적용 연구 (Application of Silver Ion for Clinical Mastitis in Holstein Cows)

  • 설재원;허태영;정영훈;박상열;강석진
    • 한국임상수의학회지
    • /
    • 제27권3호
    • /
    • pp.246-251
    • /
    • 2010
  • 유방염은 병원성 미생물들에 의한 유선 내에 염증이 생기는 질환으로, 유방 조직과 우유 내 체세포수 (SCC)와 세균학적 분석이 유방염 진단을 위해서 사용된다. 본 연구에서는 임상형 유방염이 걸린 홀스테인 소의 유선 내로 은 이온(20 ${\mu}g$/ml)을 투입하고, 유방염의 임상 증상의 변화와 우유 내 somatic cell count, 소 혈청 알부민과 lactoferrin 등과 같은 유방염 관련 인자들을 조사하였다. 은 이온의 유선 내 투입은 유방의 부종과 견고함 등의 염증 증상을 완화시켰으며, 우유의 응고와 체세포수를 감소시켰다. 또한, 우유 내 소 혈청 알부민과 lactoferrin의 농도가 은 이온의 투입에 의해 감소되었다, 그러나 임상형 유방염이 걸린 소의 유선 내 은 이온의 투입은 착유된 우유의 양과 혈액 내 백혈구와 적혈구 수를 변화시키지는 않았다. 이러한 결과는 유방염이 걸린 소에 은 이온을 유선 내로 투입 함으로서 염증과 세균의 활성을 감소시킨다는 것을 보여주며, 은 이온을 임상형 유방염의 치료에 적용할 수 있는 가능성을 보여 주는 것이다.

Evaluation of the biocidal effects of activated carbon filter supporting silver

  • Moon, Kyong-Whan;Kim, Young-Whan;Choi, Dal-Woong
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2004년도 International Conference Global Environmental Problems and their Health Consequences
    • /
    • pp.202-206
    • /
    • 2004
  • The objectives of this study are to investigate the relationship between the silver ion concentrations released from the point-of-use(POU) water purification devices installed silver impregnated activated carbon filters and the antibacterial activities against HPC bacteria. Total of 68 POU devices were tested. The concentrations of the eluted silver ion from the silver impregnated activated carbon filter showed the range from $4\;{\mu}g/L$ to $386\;{\mu}g/L$, and the HPC bacteria were found to diversely grow within the range 0-5,200 cfu/mL. The average silver concentrations released from UF units system and RO units system were $30\;{\mu}g/L$ and $73\;{\mu}g/L$, respectively. And the number of colonies were reduced significantly as the elution levels of silver exceeded $100\;{\mu}g/L$, however silver ions below the concentration of $100\;{\mu}g/L$ were not particularly effective for eradicating HPC bacteria from water.

  • PDF

Novel Silver(I) Ion Selective PVC Membrane Electrode Based on the Schiff Base (N2E,N2'E)-N2,N2'-Bis(Thiophen-2-ylmethylene)-1,1'-Binaphthyl-2,2'-Diamine

  • Jeong, Eunseon;Ahmed, Mohammad Shamsuddin;Jeong, Hae-Sang;Lee, Eun-Hee;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.800-804
    • /
    • 2011
  • A potentiometric sensor based on the Schiff base $(N^2E,N^{2'}E)-N^2,N^{2'}$-bis(thiophen-2-ylmethylene)-1,1'-binaphthl-2,2'-diamine has been synthesized and explored as an ionophore PVC-based membrane sensor selective for the silver ($Ag^+$) ion. Potentiometric investigations indicate a high affinity of this receptor for the silver ion. Seven membranes have been fabricated with different compositions, with the best performance shown by the membrane with an ionophore composition (w/w) of: 1.0 mg, PVC: 33.0 mg, DOA: 66.0 mg in 1.0 mL THF. The sensor worked well within a wide concentration range of $1.0{\times}10^{-2}$ to $1.0{\times}10^{-7}$ M, at pH 5, at room temperature (slope 57.4 mV/dec.), and with a rapid response time of 9 s; the sensor also showed good selectivity towards the silver ion over a huge number of interfering cations, with the highest selectivity coefficient for $Hg^{2+}$ at -3.7. Thus far, the best lower detection limit was $4.0{\times}10^{-8}$ M.

A New Cone Shaped Asymmetrically Substituted Calix[4]arene as an ExcellentIonophore in Construction of Ag(I) ion-Selective Membrane Electrode

  • Ganjali, Mohammad Reza;Babaei, Leila Hajiagha;Taghvaei-Ganjali, Saeed;Modjallal, Atoosa;Sahmsipur, Mojtaba;Hosseini, Morteza;Javanbakht, Mehran
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권2호
    • /
    • pp.177-181
    • /
    • 2004
  • A PVC membrane electrode for silver ion based on a new cone shaped calix[4]arene (CASCA) as membrane carrier was prepared. The electrode exhibits a Nernstian response for $Ag^+$ over a wide concentration range ($1.0{\times}10^{-1}-8.0{\times}10^{-6}$M) with a slope of 58.2 {\pm}$ 0.5 mV per decade. The limit of detection of the sensor is $5.0{\times}10^{-6}$M. The sensor has a very fast response time (~5 s) in the concentration range of ${\leq}=1.0{\times}10^{-3}$ M, and a useful working pH range of 4.0-9.5. The proposed sensor displays excellent discriminating ability toward $Ag^+$ ion with respect to common alkali, alkaline earth, transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of $Ag^+$ with EDTA and in direct determination of silver ion in wastewater of silver electroplating.

산화물유리에서의 $Na^+$이온과 $Ag^+$이온 교환에 따른 전기전도도 변화 (Electrical conductivity in oxide glasses subjected to $sodium \leftrightarrow silver$ ion exchange treatment)

  • 한준수;강원호;이효경
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권3호
    • /
    • pp.284-290
    • /
    • 1996
  • The electrical properties of bulk galsses in the system Na$_{2}$O-CaO-Al$_{2}$O$_{3}$-B$_{2}$O$_{3}$-SiO$_{2}$ containing 20 to 30mol% sodium which have been subjected to a sodium .tautm. silver ion exchange reaction for 24, 36 and 48 hrs. were analysed by impedance spectroscopy method. Ion exchanged glasses exhibit activation energy values lower than those of the untreated ones. The electrical conductivity increase with sodium content and ion exchanging time. In this experiment the electrical conductivity exhibits a manximum value of 1.78*10$^{-4}$ S/cm at 200.deg. C which contains 30mol% sodium and subjects ion exchange reaction for 48hrs.

  • PDF