• 제목/요약/키워드: Silver Alloy

검색결과 108건 처리시간 0.027초

Wetting properties between silver-copper-titanium braze alloy and hexagonal boron nitride

  • Sechi, Yoshihisa;Matsumoto, Taihei;Nakata, Kazuhiro
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.205-209
    • /
    • 2009
  • Wetting properties between silver-copper-titanium braze alloys with different titanium contents up to 2.8 mass% and hexagonal boron nitride ceramics were investigated using sessile drop method at 1123K in Argon. The final contact angle is less than $30^{\circ}$ when the Ti content was over 0.41 mass%. Meanwhile, the contact angle curves show different behavior. In case of using braze alloy containing 2.8 mass% of titanium, the initial contact angle is acute angle just after the melting of braze. In case of brazes containing titanium less than 2.26 mass%, the contact angle is larger than $90^{\circ}$ at the beginning and slowly decreases to acute angle. The reaction layer of titanium nitride is observed at the interface. In addition, the reaction of Ti in the braze and N in the bulk h-BN seemed to show diffusion limited spreading.

  • PDF

국소의치금속상과 Fe-Cr계 wire를 soldering 할때 발생한 계면의 성분변화 (Interfacial Elemental Change When Soldering the Nico-crally and Fe-Cr-Ni Alloy)

  • 조성암;고현권
    • 대한치과보철학회지
    • /
    • 제27권1호
    • /
    • pp.49-54
    • /
    • 1989
  • The purpose of this study was to investigate the interfacial elemental change when solding the Ni-Co-Cr dental removable partial denture alloy and Fe-Cr-Ni wrought wire alloy with Ag-Cu-Zu Silver solder, by EDXA, EPMA, to investigate the appropriateness of clinical usefullness for repair the fractured clasps of removable partial dentive. The result of this study was as follows: 1. The Ni element of major component of Ticonium penetrate into the silver solder 2. The movement Age element of silver solder into Fe-Cr-Ni wire was not significant, by EDXA and EPMA.

  • PDF

Electromagnetic Properties of Siver Coated Iron based Alloy Powders Prepared by Chemical Reduction Method

  • Lee, Byoung-Yoon;Lee, Jae-Wook;Yun, Yeo-Chun;Jeong, In-Bum;Moon, Joo-Ho
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1213-1214
    • /
    • 2006
  • The synthesis of silver coated iron base alloy (Sendust : Fe-Si-Al) powder having the both effects of shielding and suppressing of electromagnetic wave was studied. Depending on thickness of silver coating layer, the electromagnetic properties of the dispersed particles complexed with organic binder were examined. It is proposed that the silver coated sendust flake powders with controlled electrical properties and thickness can be used as thin microwave absorbers in quasi-microwave frequency band.

  • PDF

고대신라의 금속기술 연구 (A Study of Metal Technology in Ancient Silla Dynasity)

  • 강성군;조종수
    • 한국표면공학회지
    • /
    • 제8권1호
    • /
    • pp.1-9
    • /
    • 1975
  • The crorosion film of gilt bronz, silver and iron objects, which were excaved from Ancient Tomb of Silla Dynasty, was removed by the electrolytic reduction process. These metallic objects were mainly investigated for microstructure, designs and gilting film etc. Most iron objects might be made by hot forging process. The cold extrusion technique might be used for gold and silver objects, in addition to an amalgam method might be applied for the gilting Au film on Cu-alloy surface. For the gilting on glass surface, first, a Cu alloy was cladded on glass , next, Au-film was obtained on the Cu-ally by the amagum method.

  • PDF

온침소재의 열전달특성에 관한 연구 (Study on the Heat Transfer Characteristics of Warm Needle Materials in Korean Medicine)

  • 여수정;정지현;김영곤;구성태;이민규;임사비나
    • Korean Journal of Acupuncture
    • /
    • 제31권3호
    • /
    • pp.125-135
    • /
    • 2014
  • Objectives : Warm needling is the method combining the effects of acupuncture and moxibustion. In modern clinics, warm needling is only affected by treatment time or frequency. We need to study the physical characteristics of warm needles currently used in clinics in order to develop more efficient and economical treatments. Methods : We collected various warm needle specimens and analyzed chemical constitutions, measured heat transfer velocity, micro Vicker's hardness and specific resistance. We studied the relationship between heat transfer velocity and micro Vicker's hardness as well as that between heat transfer velocity and specific resistance. Results : The heat transfer velocity of the Silver_HL was 3.3 mm/sec, of the Au alloy group was 1.3~2.6 mm/sec, and Silver_IN, Silver_ZK and SS groups was less than 0.3 mm/sec. We therefore concluded that the needle composed of Ag has the best heat transfer velocity. In the Micro Vicker's hardness test, Vicker's hardness of the Au alloy group was 159~170 Hv, of Silver_HL was 181 Hv, and of the Silver_IN, Silver_ZK, SS group was 450.8~519 Hv. In the Silver_IN, Silver_ZK and SS groups, hardness was inversely proportial to thermal conductivity. In the specific resistance test, the specific resistance of Silver_HL was the lowest, that of the Au alloy group was the second lowest, and that of the Silver_IN, Silver_ZK, SS groups were the highest. Conclusions : We concluded that the needle composed of Ag has the best heat transfer velocity, highest electric conductivity and thermal conductivity, therefore the needle composed of Ag is suitable for warm needling.

Ge, In 첨가 은합금 주조물의 가압성형에 따른 물성변화 연구 (Property of Ge, In Added Silver Alloy with Plastic Deformation)

  • 김준환;송오성
    • 한국산학기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.1547-1551
    • /
    • 2010
  • 통상의 은합금 장신구 재료로 쓰이는 925 은합금 (Ag-7.5wt%Cu)의 가공 중 고온산화에 의한 변색 또는 착용 중 산화에 의한 색변화를 방지하기 위해서 Ag-5wt%Ge-2.5wt%Cu, 5wt%In-2.5wt%Cu의 새로운 조성을 제안하였다. 전체는 기존 925 은합금의 조성을 유지하여 기존 7.5wt%Cu합금원소를 Ge, In으로 대치하여 기존 925 은합금과 비교하여 주조공정 시의 형상변화와 주조능, 가공경화에 의한 물성과 내식성 변화를 확인하였다. 새로이 제안된 Ge, In 은합금은 기존 925은합금과 동일하거나 우수한 주조특성을 보였고, 특히 가공 중에 생기는 가공경화능력이 우수하여 내구성이 증가하였고 고온 내식성과 신체 착용 시의 내부식성이 향상됨을 확인하였다.

THE EFFECT OF GOLD ELECTROFORMING PROCEDURE ON GOLD-SILVER-PALLADIUM ALLOY

  • Hwang, Bo-Yeon;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.303-309
    • /
    • 2007
  • Statement of problem. The effect of gold electroforming on gold alloy was not studied. Purpose. This in vitro study investigate the effect of gold electroforming on gold-silver-palladium alloy. Material and methods. Three pieces of gold strips had undergone the electroforming procedures on one side and then half of the side again electroformed. The set mode for this study was program 1 ($200{\mu}m$). And the processing time was 15min (1/20 time to form $200{\mu}m$ coping). The confocal laser scanning microscope (PASCAL 5, Carl Zeiss, Bernried, Germany) was used to measure the thickness of the pure gold layer electroformed on the gold strips. Half of the gold strip was coated two times with electroformed gold, and the other half one time. The data from the cone focal laser system was processed to get the vertical profile of the strips and the difference of the vertical height between the double coated and single coated layer was regarded as the thickness of the gold coating. The layer thickness value to built 3D image of the cone-focal laser was set $0.5{\mu}m$. Next to the measurement of the thickness of the coating, the Vicker's hardness test was done. It was performed on the double coated surface, single coated surface and non-coated surface (back side) three times each. Results. The mean thickness value gained from gold electroforming technique was measured to be $22{\mu}m$ for sample 1, $23{\mu}m$ for sample 2, $21{\mu}m$ for sample 3. In the same condition of time, power and the amount of electrolyte, the data showed no difference between samples. According to the results of variance analysis, the differences among the variations in number of coating were statistically insignificant (p>0.05), meaning that the two times of gold electroforming coating did not change the hardness of gold-silver-palladium alloy. Conclusion. The test of thickness of gold coating proved the coherency of the gold electroforming procedure, in other words, when the power, the exposed surface area, processing time and the amount of electrolytes were set same, the same thickness of gold would be coated on. The hardness test showed that the electroformed gold coating did not change the hardness of the gold-silver-palladium alloy when it is coated not more than $45{\mu}m$.

A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy

  • Hong, Jun-Tae;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.372-378
    • /
    • 2014
  • PURPOSE. The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. MATERIALS AND METHODS. Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (${\alpha}=.05$). RESULTS. The 3-point bending test showed the strongest ($40.42{\pm}5.72$ MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy ($37.71{\pm}2.46$ MPa), precious metal alloy containing 83% of gold ($35.89{\pm}1.93$ MPa), and precious metal alloy containing 32% of gold ($34.59{\pm}2.63$ MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). CONCLUSION. The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa).

Ag925의 전기화학적 특성에 미치는 네오디뮴 함량의 영향 (Effect of Neodymium concentration on electrochemical properties of 925 silver)

  • 신병현;정승진;정원섭
    • 한국표면공학회지
    • /
    • 제54권2호
    • /
    • pp.71-76
    • /
    • 2021
  • Ag925, silver with added copper, is popular alloy due to its low price. However, it has a difficult to use because of the low corrosion resistance. In various alloys, neodymium (Nd) works as an element to improve corrosion resistance by reacting with interstitial elements in the alloy. When 1.5 wt. % Neodymium was added to Ag925, the potential on the activated polarization in a potentiodynamic polarization test was increased from -0.15 V to -0.05 V. Ag925 with added neodymium showed the passivation after activation polarization. But When the potential increased around 50 mV, the current density is increased to 3 × 10-3. Ag925 with the 1.5 wt. % Nd had the low corrosion rate.

오동상감(烏銅象嵌)기법을 활용한 장도(粧刀)의 제작기술 및 복원연구 (Jangdo(Small Ornamental Knives) manufacturing process and restoration research using Odong Inlay application)

  • 윤용현;조남철;정영상;장추남
    • 헤리티지:역사와 과학
    • /
    • 제49권2호
    • /
    • pp.172-189
    • /
    • 2016
  • 본 연구에서는 "오주서종박물고변(五洲書種博物考辯)", "천공개물(天工開物)" 등 고문헌에 기록된 오동 재료와 합금비, 주조 시설, 주조법 등을 확인하고 이를 기초자료로 활용하여 오동상감기법으로 장도를 제작하였다. 오동상감기법 장도 제작은 크게 오동 합금, 은땜 합금, 오동판과 은판 제작, 칼자루와 칼집 제작, 장도의 장석인 두겁 및 부속품 제작, 오동 상감, 조립의 순으로 진행하였다. 오동의 합금은 "오주서종박물고변"에 보이는 상품(上品)으로 전통방식의 진오동(眞烏銅) 합금비인 구리와 금을 20:1의 중량비로 하였다. 은땜의 합금은 상감된 문양에 사용한 경우 은과 황동(Cu 7 : Zn 3)을 중량비 5:1로, 단순 접합 사용한 경우에는 은과 황동을 중량비 5:2로 합금하여 은땜판을 제작하였다. 칼집과 칼자루 제작은 진오동 합금비로 만든 오동 괴를 풀림과 단조작업을 실시하여 오동판의 두께를 0.6mm로, 오동의 뒷면인 은판도 두께 0.6mm로 제작한 뒤, 오동판과 은판 접합, 풀림과 단조, 오동판에 문양 새기기, 은 상감하기, 오동판으로 칼집과 칼자루 모양잡기, 은땜으로 접합하기, 연마 및 광택내기 등의 과정을 거쳐 완성하였다. 붉은색의 오동판 표면을 검은색으로 부식시키는 '오동 살리기(발색하기)'는 오동 합금의 품위에 따라 발색 효과가 차이가 난다. 한지를 30일 정도 썩힌 인뇨(人尿)에 적셔 칼집과 칼자루 등에 감아 따뜻한 곳($25^{\circ}C$ 이상)에 두고 2~3시간이 경과하면 오동판의 겉면만 검은색으로 발색되고 은이 상감된 문양은 그대로 있어 오동상감기법을 재현할 수 있었다. 오동상감 복원에 사용했던 오동판, 은판, 은땜판의 합금성분과 오동의 표면 발색성분을 알기 위해 과학분석을 실시하였다. 오동 합금 분석(시료 2개)결과 고문헌 기록(Cu 95wt%, Au 5wt%)과 평균성분비가 유사한 Cu 95.57wt%, Au 4.16wt%과 차이가 있는 Cu 98.04wt%, Au 1.95wt%로 검출되었는데, 전자는 오동판 가공에 성공률이 높은 반면, 후자는 가공과정에서 터지는 등의 실패가 있었다. 오동판과 은판이 부착된 시료의 성분분석 결과 은판 부분은 Ag 100wt%로 검출되었고, 오동판과 은판이 접합된 부분은 Cu, Ag, Au가 모두 검출되어 접합이 잘 되었음을 확인할 수 있었다. 은과 황동을 합금한 은땜판은 분석결과 Ag 성분이 다양하게 검출되고 있어 성분비와 관계없이 매우 불균질하게 섞여있음을 관찰하였다. 오동판에 검은색으로 발색된 부분의 성분분석 결과 소지 금속에서 검출되지 않았던 S의 함량이 검출되어 S의 함량이 오동 색상에 영향을 미친 것으로 판단되었다. 향후 발색에 대한 정확한 메커니즘을 밝히기 위해서는 추가적인 화합물, 색도 및 재현 연구 등 추가연구가 필요하다. 이번 연구를 통해 시도 및 확인된 고문헌 속의 오동합금 실험 및 재현, 오동상감기법에 의한 장도제작, 오동판 검은색 발색 메커니즘의 과학 분석결과 등은 오동상감기법의 복원을 위한 중요한 기초자료로 활용될 수 있을 것이다.