• Title/Summary/Keyword: Silicone

Search Result 1,466, Processing Time 0.029 seconds

120 Cases of Facial Foreign Body Granuloma (안면부 이물 육아종 120례의 치험례)

  • Park, Tae-Hwan;Seo, Sang-Won;Kim, June-Kyu;Chang, Choong-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.233-238
    • /
    • 2010
  • Purpose: As the use of soft tissue fillers becomes more popular, complications such as foreign body granuloma (FBG) are increasing. We report 120 cases of facial FBG and review the available literatures. Methods: 120 patients of facial FBG in our clinic from Mar. 2003 to Feb. 2008 were complied and analyzed. A retrospective chart review was done and patient satisfaction was evaluated with a questionnaire using 5 score scale. Patients with severe inflammation sign or bizarre deformity underwent surgical excision and those with minimal symptoms or a history of hyaluronic acid injection received injection therapy using hyaluronidase. Results: 100 females and 20 males were observed. The average age was 43.7 years (from 16 to 74). 84 patients received surgical therapy and 36, injection therapy. Deformity of facial contour, foreign body sensation and inflammation sign were the three main chief complaints. 84 patients did not know what the injection materials were. The known materials are as follows: collagen, hyaluronic acid, silicone oil, paraffin. 92 cases were performed by unlicensed practitioners, 29 by physicians. Anatomical site most frequently affected by the foreign body granuloma was the cheek (25.8%), followed by forehead (19.2%), lips (15.8%), nose (9.2%), mentum (8.3%), eyelid and eyebrow (4.3%) and temple (0.8%). In 21 patients (17.5%), FBGs were found on multiple sites. Patients with inflammation sign got the highest satisfaction ($3.19{\pm}0.73$) (p=0.001) among 3 chief complaints. And patient satisfaction was statistically higher in surgical therapy group ($3.43{\pm}0.72$) than in injection therapy group ($2.97{\pm}0.88$) (p=0.003). Conclusion: We suggest that it may be beneficial to tailor the type of treatment for FBG relying on wound state and patient's chief complaints. In surgical therapy, resolute approach is necessary to correct facial deformity definitely and to minimize inflammation. Injection therapy could be another option for those with minimal symptoms or a history of hyaluronic acid injection. To prevent foreign body granuloma, not only plastic surgeons but also other physicians should inject soft tissue fillers with great caution and we should warn the public of disastrous consequences associated with illegal medical practice.

Synthesis and Application of Bluish-Green BaSi2O2N2:Eu2+ Phosphor for White LEDs (백색 LED용 청록색 BaSi2O2N2:Eu2+ 형광체의 합성 및 응용)

  • Jee, Soon-Duk;Choi, Kang-Sik;Choi, Kyoung-Jae;Kim, Chang-Hae
    • Korean Journal of Materials Research
    • /
    • v.21 no.5
    • /
    • pp.250-254
    • /
    • 2011
  • We have synthesized bluish-green, highly-efficient $BaSi_2O_2N_2:Eu^{2+}$ and $(Ba,Sr)Si_2O_2N_2:Eu^{2+}$ phosphors through a conventional solid state reaction method using metal carbonate, $Si_3N_4$, and $Eu_2O_3$ as raw materials. The X-ray diffraction (XRD) pattern of these phosphors revealed that a $BaSi_2O_2N_2$ single phase was obtained. The excitation and emission spectra showed typical broadband excitation and emission resulting from the 5d to 4f transition of $Eu^{2+}$. These phosphors absorb blue light at around 450 nm and emit bluish-green luminescence, with a peak wavelength at around 495 nm. From the results of an experiment involving Eu concentration quenching, the relative PL intensity was reduced dramatically for Eu = 0.033. A small substitution of Sr in place of Ba increased the relative emission intensity of the phosphor. We prepared several white LEDs through a combination of $BaSi_2O_2N_2:Eu^{2+}$, YAG:$Ce^{3+}$, and silicone resin with a blue InGaN-based LED. In the case of only the YAG:$Ce^{3+}$-converted LED, the color rendering index was 73.4 and the efficiency was 127 lm/W. In contrast, in the YAG:$Ce^{3+}$ and $BaSi_2O_2N_2:Eu^{2+}$-converted LED, two distinct emission bands from InGaN (450 nm) and the two phosphors (475-750 nm) are observed, and combine to give a spectrum that appears white to the naked eye. The range of the color rendering index and the efficiency were 79.7-81.2 and 117-128 lm/W, respectively. The increased values of the color rendering index indicate that the two phosphor-converted LEDs have improved bluish-green emission compared to the YAG:Ce-converted LED. As such, the $BaSi_2O_2N_2:Eu^{2+}$ phosphor is applicable to white high-rendered LEDs for solid state lighting.

A Study on the Development of Sound Absorption Material Using Perlite for Noise Barrier Wall (펄라이트를 이용한 방음벽의 흡음소재 개발에 관한 기초적 연구)

  • Jo, Young-Kug;Yang, Ju-Kyung
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.653-660
    • /
    • 2008
  • The purpose of this study is to analyze the optimal mix design of the sound absorption material that is made from perlite and various binder systems for noise barrier wall. The polymer cement slurry which is made from two types of polymer dispersions, and silicone type inorganic material are used as binder. The test specimens are prepared with various polymer cement ratios, binder ratios, and tested for strengths, freezing and thawing and sound absorption performance by the tube and the reverberation room methods. From the test results, the difference of sound absorption coefficient by the tube method is a little recognized, however, noise reduction coefficient (NRC) of test specimens bound by the polymer cement slurry is in the ranges of 0.48 to 0.51. They are a little higher than those bound by cement only, and are lower values than recommended value of 0.7 by the Ministry of Environment. However, the sound absorption coefficient of test specimens at low frequency range of 250 to 500 Hz by reverberation room method shows very high values as 0.84 to 1.00, and 0.57 to 0.77 at the high frequency. The test specimens with polymer cement slurry binder have a good balance between performance and cost, and have proper properties in strengths, freezing and thawing resistance as sound absorption material for noise barrier wall. It is apparent that the good sound absorption material can be produced according to the optimum mix design that is recommended from this study.

Studies on the Removal of Volatile Organic Compounds in Wastewater using PTMSP/PDMS-PEI Composite Membrane by Pervaporation (PTMSP/PDMS-PEI 복합막을 이용한 폐수중의 휘발성 유기화합물 제거에 관한 연구)

  • Kweon, Chang-Oh;Paik, Gwi-Chan;Chun, Kyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3532-3540
    • /
    • 2011
  • In order to improve flux of PTMSP/PDMS dense membrane, PTMSP/PDMS-PEI composite membrane with PEI support was prepared by phase inversion process and dip coating. These membranes were evaluated in terms of the removal of volatile organic compounds such as PCE, TCE, chloroform, 1,1,1-trichloroethane from wastewater by pervaporation. The selectivity and flux of PTMSP/PDMS dense membranes was in the range of 216.2 to 2394.4 and 244.3 to 428.2g/m2h, respectively. And pervaporation property of PTMSP/PDMS-PEI composite membrane was in the range of 215.5 to 2404.2 and 390.4 to 728.6g/m2h, respectively. PTMSP/PDMS-PEI composite membrane has remarkably greater flux than dense membranes with similar selectivity. It was possible for polymeric membranes used in this study to remove PCE selectively which is dissolved small quantity in water among other separable solutes. PTMSP/PDMS-PEI composite membrane showed the best performances among the silicone polymeric membranes, and has better durability and mechanical strength than dense membranes. PTMSP/PDMS-PEI composite membrane should be a useful candidate for the removal of volatile organic compounds dissolved in wastewater.

Reccurent Foreign body Granuloma after Gore-tex Removal in Rhinoplasty (융비술에서 고어텍스 제거 후 발생한 재발성 이물성 육아종의 치험례)

  • Kwon, Soon Geun;You, Young Cheun;Yang, Won Yong;Park, Jun;Kang, Sang Yun
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.611-614
    • /
    • 2008
  • Purpose: Infection, foreign body reaction and decreased volume of implant are common complications after augmentation rhinoplasty with $Gore-tex^{(R)}$ implant. The author experienced two cases of recurrent foreign body granuloma in the patients who underwent $Gore-tex^{(R)}$ removal because of infection after augmentation rhinoplasty. and treated them with complete removal of$Gore-tex^{(R)}$. Methods: Case 1: A 49 year-old female visited our clinic for recurrent foreign body reaction on nasal dorsum and tip area. The patient underwent augmentation rhinoplasty with $Gore-tex^{(R)}$ 3 years ago and implant was removed due to infection 9 months ago. Excision of the granuloma was performed and a piece of foreign body suspicious to be a $Gore-tex^{(R)}$ implant debris was detected under the subcutaneous pocket. The implant fragments were removed and nasalis muscle rotation flap was performed to cover the lesion. The specimen was proved to be $Gore-tex^{(R)}$ in histological study. Case 2: A 31 year-old-male with recurrent foreign body granuloma on the nasal tip area visited our clinic. 10 years ago, the patient had augmentation rhinoplasty with silicone implant and then, he underwent revisional rhinoplasty five times including nasal implant removal, which was performed 9 months ago. The authors excised the granuloma and found a small sized foreign body suspicious to be a $Gore-tex^{(R)}$ implant debris under the granuloma. The foreign body was excised and identified to be $Gore-tex^{(R)}$ in histological study. Results: In both cases, the lesions were healed without any complications and there were no evidences of recurrence up to 6 months of follow-up. Conclusion: The $Gore-tex^{(R)}$ is known to be weak against mechanical force. These properties of $Gore-tex^{(R)}$ make it difficult to remove the implant completely. In the patient who have infection after augmentation rhinoplasty with $Gore-tex^{(R)}$, the operator should take care to perform the complete removal without remaining fragment of the implant.

Evaluation of Brain Damage Induced by Transient Occlusion of Middle Cerebral Artery in Rats

  • Insook Jung;Lee, Juseon;Melissa D. Oh;Kim, Myungsoo;Changbae Jin
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1997.04a
    • /
    • pp.103-103
    • /
    • 1997
  • 일시적인 국소 뇌허혈 rat model에서 중대뇌동맥의 폐쇄시간에 따른 뇌조직의 손상정도를 비교 조사하였다. 웅성 Wistar rats를 isoflurane 홉입마취하에서 우측 내경동맥내로 17 mm의 silicone-coated 4-0 nylon monofilament를 삽입하여, 중대뇌동맥의 기저부를 30분, 60분 또는 90분동안 폐쇄한 후 이 monofilament를 다시 밖으로 뽑아내므로써 23 시간동안 recirculation 시키는 일시적 국소 뇌허혈 rat model을 사용한 결과, 수술 후 거의 모든 rats에서 left hemiparesis 또는 좌측으로의 circling과 같은 신경학적 결손이 나타나므로써 높은 성공률을 가지고서 비교적 용이하게 뇌허혈을 유발시킬 수 있었으며, 2 mm 두께의 fresh brain coronal slices에 대하여 2,3,5-triphenyltetrazolium chloride (TTC) 염색법을 시행하여 slice surface의 사진을 찍고 computerized 영상분석법을 이용하여 필요한 면적을 측정하므로써, coronal slice의 infarction size (%)는 총 면적에 대한 infarction 면적의 %로서, 부종율 (%)은 대조측 대뇌반구 면적의 2배에 대한 동측 대뇌반구와 대조측 대뇌반구 면적 차이의 %로서 산정되어졌다. 30분 허혈군에서는 본 염색법으로는 infarction이 거의 확인되지 않았으나 60분 허혈군 (n=13)에서는 우측 somatosensory frontoparietal cortex와 striatum 양자 모두 또는 일부 rats에서는 striatum에만 국한된 ulfarction이 확인되어졌으며 90분 허혈군 (n=12)에서는 거의 대부분의 rats에서 위 두 지역 모두에서 infarction이 확인되어졌다. Infarction size (%)는 60분과 90분 허혈군 각각에서, frontal pole로부터 5 mm되는 slice에서는 11.9$\pm$1.2 (평균치$\pm$표준오차), 13.7$\pm$1.9이었으며 7 mm되는 slice에서는 19.1$\pm$1.8, 21.9$\pm$2.1이었으며 9 mm되는 slice에서는 14.7$\pm$2.4, 19.7$\pm$2.2이었다. 또한 부종율 (%)은 60분과 90분 허혈군 각각에서, frontal pole로부터 5 mm되는 slice에서는 3.1$\pm$0.6, 3.8$\pm$0.7이었으며 7 mm되는 slice에서는 3.5$\pm$0.3, 5.7$\pm$1.0이었으며 9 $\pm$되는 slice에서는 3.4$\pm$0.5, 5.7$\pm$0.9이었다. 한편 90분 동안의 중대뇌동맥 폐쇄에 따른 뇌조직 손상을 cresyl violet 염색법, NADPH-diaphorase histochemistry, GFAP immunohistochemistry를 사용하여 일부 측정한 결과, 위의 손상지역에서는 뇌신경세포체들의 shrinkage 내지는 소실됨을 확인할 수 있었으며, NADPH-diaphorase-positive neuron들도 대부분 dendrite와 axon같은 cell process들의 fragmentation, shrinkage 내지는 소실되므로써 intensity의 감소현상이 나타났으며, reactive gliosis로 말미암아 GFAP immunoreactive intensity의 증가현상이 나타났다.

  • PDF

Effects of Catalysts and Blowing Agents on the Physical Properties and Cell Morphology of Polyurethane Foams (폴리우레탄 폼의 물성과 Cell Morphology에 대한 촉매와 발포제의 영향)

  • Kwon, Hyun;Lee, Su Heon;Kim, Sang Bum;Bang, Moon-Soo;Kim, Youn Cheol
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.379-384
    • /
    • 2005
  • Polyurethane foams (PUFs) were prepared from polymeric 4,4'-diphenylmethane diisocyanate (PMDI), seven polyols with different functionalities and OH values, silicone surfactant, two catalysts, and three blowing agents. Chlorofluorocarbon (CFC-11), hydrochlorofluorocarbon (HCFC-141b) and hydrofluorocarbon (HFC-365mfc) were used as blowing agents. The effect of gelling and blowing catalysts on basic properties and cell structure of PUF with HCFC-141b was investigated. The cell size of the PUF decreased with an increase in the amount of catalyst from 0 to 2 pph (parts per hundred polyol). In the case of gelling type catalyst, the compressive strength increased from 11.9 to $12.66kg_f/cm^2$ with an increase in the amount catalyst from 0 to 2 pph but the density did not change significantly. The gelling time, density, and compressive strength of the PUF with three different blowing agents were measured. There was no detectable change in their properties. However, the cell structure of PUF with HCFC-141b was not uniform as in the other systems.

Optimum design of injection mold heater for uniform curing of LSR seal for waterproof connector (방수 커넥터용 LSR Seal의 균일 경화를 위한 사출 금형 히터의 최적 설계)

  • Song, Min-Jae;Cha, Baeg-Soon;Hong, Seok-Kwan;Ko, Young-Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.310-315
    • /
    • 2017
  • Automotive waterproof connectors are highly functional parts that must be air-tight in a complex environment. In the LSR multi-cavity injection molding process for manufacturing waterproof connectors, it is important to maintain a uniform curing temperature between the cavities in order to obtain a quality product. For this purpose, we designed the capacity of the cartridge heater differently for each position, and then linked the heat transfer analysis and optimization module to obtain the optimal cartridge heater capacity. As a result of the optimization analysis, the temperature deviation between cavities was decreased from $13.1^{\circ}C$ to $8.1^{\circ}C$ compared with the case in which constant heater capacity was applied, so that the design criterion could be satisfied within a temperature deviation of $10^{\circ}C$ for uniform curing. This study suggests that this method can be applied efficiently to the design of a large area multi-cavity LSR mold heater.

Synergistic Interaction in W/O and W/S Emulsions Stabilized by a Mixture of Powders and Surfactant (분체와 유화제의 상호 관계성에 기인한 저점도 W/O 및 W/S 에멀젼의 안정성 연구)

  • In, So Hyun;Cho, Hwanil;Kang, Nae Gyu;Han, Jong Sup;Park, Sun Gyoo;Lee, Cheon Koo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.1
    • /
    • pp.15-28
    • /
    • 2016
  • Water-in-oil emulsions including water-in-ester oil and water-in-silicone oil (W/O+S) have various advantages such as blocking moisture evaporation and forming air permeable membrane. However, their applications have been limited due to the poor stability under low viscosity condition. In this study, we investigated the effect of synergistic interaction between nonionic surfactant, micro-size particles and cationic surfactant on the stability of W/O+S formulation. The stability of W/O+S emulsions was changed as a function of cationic surfactant concentration where it increased at lower concentration and then started to decrease above a critical point. Finally, emulsion phase inversion occurred at a high concentration. The results suggest that W/O+S emulsions of low viscosity ranging from 2000 to 5000 cps can be stabilized under the conditions where a nonionic surfactant, micro-size particles and a cationic surfactant are used in the range of 1.0 ~ 4.0 wt%, 2.5 wt% and 0.1 ~ 0.5 wt%, respectively.

Preparation of Asymmetric Folyethersulfone Hollow Fiber Membranes for Flue Gas Separation (온실기체 분리용 폴리이서설폰 비대칭 중공사 막의 제조)

  • Kim Jeong-Hoon;Sohn Woo-Ik;Choi Seung-Hak;Lee Soo-Bok
    • Membrane Journal
    • /
    • v.15 no.2
    • /
    • pp.147-156
    • /
    • 2005
  • It is well-known that polyethersulfone (PES) has high $CO_2$ selectivity over $N_2\;(or\;CH_4)$ and excellent pressure resistance of $CO_2$ plasticization among muy commercialized engineering plastics[1-4]. Asymmetric PES hollow fiber membranes for flue gas separation were developed by dry-wet spinning technique. The dope solution consists of PES, NMP and acetone. Water and water/NMP mixtures are used in outer and inner coagulants, respectively. Gas permeation rate (i.e., permeance) and $CO_2/N_2$ selectivity were measured with pure gas, respectively and the micro-structure of hollow fiber membranes was characterized by scanning electron microscopy. The effects of polymer concentration, ratio of NMP to acetone, length of air gap, evaporation condition and silicone coating were investigated on the $CO_2/N_2$ separation properties of the hollow fibers. Optimized PES hollow fiber membranes exhibited high permeance of $25\~50$ GPU and $CO_2/N_2$ selectivity of $30\~40$ at room temperature and have the apparent skin layer thickness of about $0.1\;{\mu}m$. The developed PES hollow fiber membranes, would be a good candidate suitable for the flue gas separation process.