• Title/Summary/Keyword: Silicone

Search Result 1,466, Processing Time 0.025 seconds

Evaluation of fitness according to application of glass fiber reinforcement for lower jaw complete denture (하악 총의치 전용의 유리섬유 보강재 적용에 따른 적합도 비교 분석)

  • Kim, Dong-Yeon;Park, Jin-Young;Bae, So-Yeon;Kang, Hoo-Won;Kim, Ji-hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.40 no.4
    • /
    • pp.201-207
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the fitness of lower jaw compete denture with glass fiber. Methods: Lower jaw edentulous model was selected as the master model. Ten study models were produced using Type IV stone(n=10). Lower jaw trial dentures were produced by the wax denture base and artificial teeth. Conventional complete denture (CD) group was fabricated by excluding glass fiber reinforcement (n=5). Glass fiber complete denture (GD) group was fabricated with glass fiber reinforcement (n=5). The lower jaw trial complete denture was invested using a plaster. PMMA resin was injected and curing was performed. The CD and GD groups measured the fit using silicone replica technology. The measured data was verified by t-test. Results: The anterior area of the CD group showed the smallest value. There was a statistically significant difference in the anterior area of the CD group and the GD group (p<0.05), but there was no statistically significant difference in the posterior area (p>0.05). Conclusion : Complete denture with glass fiber showed low fitness and further study is needed to apply it clinically.

Geometric Evaluation of Patient-Specific 3D Bolus from 3D Printed Mold and Casting Method for Radiation Therapy

  • An, Hyun Joon;Kim, Myeong Soo;Kim, Jiseong;Son, Jaeman;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.30 no.1
    • /
    • pp.32-38
    • /
    • 2019
  • Purpose: The objective of this study is to evaluate the geometrical accuracy of a patient-specific bolus based on a three-dimensional (3D) printed mold and casting method. Materials and Methods: Three breast cancer patients undergoing treatment for a superficial region were scanned using computed tomography (CT) and a designed bolus structure through a treatment planning system (TPS). For the fabrication of patient-specific bolus, we cast harmless certified silicone into 3D printed molds. The produced bolus was also imaged using CT under the same conditions as the patient CT to acquire its geometrical shape. We compared the shapes of the produced bolus with the planned bolus structure from the TPS by measuring the average distance between two structures after a surface registration. Results and Conclusions: The result of the average difference in distance was within 1 mm and, as the worst case, the absolute difference did not exceed ${\pm}2mm$. The result of the geometric difference in the cross-section profile of each bolus was approximately 1 mm, which is a similar property of the average difference in distance. This discrepancy was negligible in affecting the dose reduction. The proposed fabrication of patient-specific bolus is useful for radiation therapy in the treatment of superficial regions, particularly those with an irregular shape.

A novel technique for placing titanium mesh with porous polyethylene via the endoscopic transnasal approach into the orbit for medial orbital wall fractures

  • Bae, Seong Hwan;Jeong, Dae Kyun;Go, Ju Young;Park, Heeseung;Kim, Joo Hyoung;Lee, Jae Woo;Kang, Taewoo
    • Archives of Plastic Surgery
    • /
    • v.46 no.5
    • /
    • pp.421-425
    • /
    • 2019
  • Background The endoscopic transnasal approach is widely used for reconstructing the medial orbital wall by filling it with a silicone sheet or Merocel, but this technique has the disadvantage of retaining the packing for a long time. To overcome this drawback, a method of positioning an absorbable plate in the orbit has been introduced, but there is a risk of defect recurrence after the plate is absorbed. Here, the authors report the results of a novel surgical technique of placing a nonabsorbable titanium mesh with porous polyethylene into the orbit through the endoscopic transnasal approach. Methods Fourteen patients underwent surgery using the endoscopic transnasal approach. Preoperative computed tomography (CT) was used to calculate the size of the bone defect due to the fracture, and the titanium mesh was designed to be shorter than the anteroposterior length of the defect and longer than its height. The titanium mesh was inserted into the orbit under an endoscopic view. The authors then confirmed that the titanium mesh supported the orbital contents by pressing the eyeball and finished the operation. Immediately after surgery, CT results were evaluated. Results Postoperative CT scans confirmed that the titanium mesh was well-inserted and in the correct position. All patients were discharged without any complications. Conclusions We obtained satisfactory results by inserting a titanium mesh with porous polyethylene into the orbit via the transnasal approach endoscopically.

Comparison of 2-dimensional marginal and internal fitness for the monolithic zirconia prosthesis using intraoral scanner and extraoral scanner: in vitro (Extraoral scanner와 intraoral scanner를 이용하여 제작된 zirconia crown의 2차원 변연 및 내면 적합도 비교: in vitro)

  • Lee, Tae-Hee;Lee, Ha-Bin;Kim, Ji-hwan
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.187-193
    • /
    • 2019
  • Purpose: The purpose of this study was to compare two-dimensional fitness of the monolithic zirconia prosthesis by using different type of scanner. Methods: No. 26 abutment tooth of FDI system was selected for the study. Using the extraoral scanner and intraoral scanner, the abutment tooth was scanned 10 times and the scanned files were saved as STL files. CAD/CAM system was used to produce the monolithic zirconia prosthesis. marginal and internal gap of the monolithic zirconia prosthesis were measured by digital microscope(x160) and applied silicone replica technique was applied. t-test, a statistical software, was used to perform data analysis. Results: Marginal gap $mean{\pm}SD$ of the monolithic zirconia prosthesis was $33{\pm}7.5{\mu}m$ with extra oral scanner and $34.7{\pm}11.1{\mu}m$ with intraoral scanner. axial gap mean was $40.5{\pm}3.5{\mu}m$ with extra oral scanner and $44.6{\pm}11.6{\mu}m$ with intraoral scanner. occlusal gap mean was $110.1{\pm}25.4{\mu}m$ with extra oral scanner and $64{\pm}9.7{\mu}m$ with intraoral scanner. Conclusion: In this study, fabricating zirconia prosthesis with different type of scanner was clinically applicable.

Physical characteristics of ceramic/glass-polymer based CAD/CAM materials: Effect of finishing and polishing techniques

  • Ekici, Mugem Asli;Egilmez, Ferhan;Cekic-Nagas, Isil;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.128-137
    • /
    • 2019
  • PURPOSE. The aim of this study was to compare the effect of different finishing and polishing techniques on water absorption, water solubility, and microhardness of ceramic or glass-polymer based computer-aided design and computer-aided manufacturing (CAD/CAM) materials following thermocycling. MATERIALS AND METHODS. 150 disc-shaped specimens were prepared from three different hybrid materials and divided into five subgroups according to the applied surface polishing techniques. All specimens were subjected up to #4000 grit SiC paper grinding. No additional polishing has been done to the control group (Group I). Other polishing procedures were as follows: Group II: two-stage diamond impregnated polishing discs; Group III: yellow colored rubber based silicone discs; Group IV: diamond polishing paste; and Group V: Aluminum oxide polishing discs. Subsequently, 5000-cycles of thermocycling were applied. The analyses were conducted after 24 hours, 7 days, and 30 days of water immersion. Water absorption and water solubility results were analyzed by two-way ANOVA and Tukey post-hoc tests. Besides, microhardness data were compared by Kruskal-Wallis and MannWhitney U tests (P<.05). RESULTS. Surface polishing procedures had significant effects on water absorption and solubility and surface microhardness of resin ceramics (P<.05). Group IV exhibited the lowest water absorption and the highest microhardness values (P<.05). Immersion periods had no effect on the microhardness of hybrid ceramic materials (P>.05). CONCLUSION. Surface finishing and polishing procedures might negatively affect physical properties of hybrid ceramic materials. Nevertheless, immersion periods do not affect the microhardness of the materials. Final polishing by using diamond polishing paste can be recommended for all CAD/CAM materials.

Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kang, Seen-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.24-35
    • /
    • 2021
  • PURPOSE. This study was to evaluate the effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing. MATERIALS AND METHODS. The maxillary right first molar master die was duplicated using a silicone material, while a study die was produced using epoxy resin. Scans of the epoxy resin die were used in combination with CAD software to design a maxillary right first molar interim crown. Based on this design, 24 interim crowns were fabricated with digital light processing. This study examined the trueness and precision of products that were processed with one of the three different postprocessing rinsing times (1 min, 5 min, and 10 min). Trueness was measured by superimposing reference data with scanned data from external, intaglio, and marginal surfaces. Precision was measured by superimposing the scan data within the group. The trueness and precision data were analyzed using Kruskal-Wallis, nonparametric, and post-hoc tests, and were compared using a Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. The trueness of the external and intaglio surfaces of crowns varied significantly among the different rinsing times (P=.004, P=.003), but there was no statistically significant difference in terms of trueness measurements of the marginal surfaces (P=.605). In terms of precision, statistically significant differences were found among the external, intaglio, and marginal surfaces (P=.001). CONCLUSION. Interim crowns rinsed for 10 minutes showed high accuracy.

Aging Property Studies on Rubber Gasket for Polymer Electrolyte Membrane Fuel Cell Stack (고분자 전해질 연료전지 스택용 고무 개스킷의 노화특성 연구)

  • Kang, Dong-gug;Hur, Byung-ki;Lee, Dong-won;Seo, Kwan-ho
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.149-154
    • /
    • 2011
  • In order to explore properties of various rubber compounds after thermal aging under the condition similar to the operating environment of a fuel cell-stack, heat resistance and compression set of those compounds were investigated for a long term operation in $H_2SO_4$, $H_2O$, and LLC (ethylene glycol : $H_2O=50:50$) solution. It was assumed that aging Acrylonitrile butadiene rubber (NBR) and Elthylene Propylene diene rubber (EDPM) compound in the solution resulted in discoloration as time passed. It was also found that hydrolysis was developed on the Silicone rubber (VMQ) compound intentionally aged under acidic condition by means of TGA, SEM, and EDS analysis.

Hole Identification Method Based on Template Matching for the Ear-Pins Insertion Automation System (이어핀 삽입 자동화 시스템을 위한 템플릿 매칭 기반 삽입 위치 판별 방법)

  • Baek, Jonghwan;Lee, Jaeyoul;Jung, Myungsoo;Jang, Minwoo;Shin, Dongho;Seo, Kapho;Hong, Sungho
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.1
    • /
    • pp.7-14
    • /
    • 2021
  • In jewelry industry, the proportion of labor costs is high. Also, the production time and quality of products are highly varied depending on the workers' capabilities. Therefore, there is a demand from the jewelry industry for automation. The ear pin insertion automation system is the robot automatically inserts the ear pins into the silicone mold, and this automated system require accurate and fast hole detection method. In this paper, we propose optimal binarization method and a template matching method that can be applied in the ear pin insertion automation system. Through the performance test, it was shown that the applied method has an accuracy of 98.5% and 0.5 seconds faster processing speed than the Otsu binarization method. So, this automation system can contribute to cost reduction, work time reduction, and productivity improvement.

Accuracy evaluation of dental model scanner according to occlusal attrition type (교합면의 교모형태에 따른 치과용 모형 스캐너의 정확도 평가)

  • Kim, Dong-Yeon;Kim, Ji-Hwan;Lee, Beom-Il;Lee, Ju-Hee;Kim, Won-Soo;Park, Jin-Young
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study is to compare and analyze the accuracy of single crowns based on the type of occlusal surface. Methods: A single crown wax pattern was fabricated in three types of occlusal surface. The prepared wax pattern was replicated with silicone, and stone was injected to create a stone model. The prepared specimens were scanned using a model scanner. Scans were classified into three groups, and each scan was performed six times to analyze the trueness and precision of a single crown. In addition, only the occlusal surface area was analyzed for trueness and precision. Data were analyzed using the Kruskal-Wallis H test, a nonparametric test (α=0.05). Results: With regard to the trueness value of the occlusal scan area, the no occlusal tooth attrition (NA) group showed the largest error of 3.5 ㎛, and the complete occlusal tooth attrition (CA) group showed the lowest value of 3.1 ㎛. The NA group had the greatest precision, and the medium occlusal tooth attrition (MA) group and CA group showed a low precision value of 3.2 ㎛; the difference between the groups was statistically significant (α=0.05). In the color difference map, the CA group showed a lower error than the NA group. Conclusion: The occlusal surface with severe attrition had excellent accuracy, but the accuracy of the group without attrition was low. There were significant differences between groups, but clinically acceptable values were shown.

In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies

  • Ozal, Cise;Ulusoy, Mutahhar
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.373-384
    • /
    • 2021
  • PURPOSE. This study aimed to compare the marginal and internal fit of 3-unit monolithic zirconia restorations that were designed by using the data obtained with the aid of intraoral and laboratory scanners. MATERIALS AND METHODS. For the fabrication of 3-unit monolithic zirconia restorations using impressions taken from the maxillary master cast, plaster cast was created and scanned in laboratory scanners (InEos X5 and D900L). The main cast was also scanned with different intraoral scanners (Omnicam [OMNI], Primescan [PS], Trios 3 [T3], Trios 4 [T4]) (n = 12 per group). Zirconia fixed partial dentures were virtually designed, produced from presintered block, and subsequently sintered. Marginal and internal discrepancy values (in ㎛) were measured by using silicone replica method under stereomicroscope. Data were statistically analyzed by using 1-way ANOVA and Kruskal Wallis tests (P<.05). RESULTS. In terms of marginal adaptation, the measurements on the canine tooth indicated better performance with intraoral scanners than those in laboratory scanners, but there was no difference among intraoral scanners (P<.05). In the premolar tooth, PS had the lowest marginal (86.9 ± 19.2 ㎛) and axial (92.4 ± 14.8 ㎛), and T4 had the lowest axio-occlusal (89.4 ± 15.6 ㎛) and occlusal (89.1 ± 13.9 ㎛) discrepancy value. In both canine and premolar teeth, the D900L was found to be the most marginally and internally inconsistent scanner. CONCLUSION. Within the limits of the study, marginal and internal discrepancy values were generally lower in intraoral scanners than in laboratory scanners. Marginal discrepancy values of scanners were clinically acceptable (< 120 ㎛), except D900L.