• Title/Summary/Keyword: Silica-fume

Search Result 582, Processing Time 0.026 seconds

Experimental and numerical studies on flexural behavior of high strength concrete beams containing waste glass

  • Haido, James H.;Zainalabdeen, Marwa A.;Tayeh, Bassam A.
    • Advances in concrete construction
    • /
    • v.11 no.3
    • /
    • pp.239-253
    • /
    • 2021
  • The behavior of concrete containing waste glass as a replacement of cement or aggregate was studied previously in the most of researches, but the present investigation focuses on the recycling of waste glass powder as a substitute for silica fume in high strength concrete (HSC). This endeavor deals with the efficiency of using waste glass powder, as an alternative for silica fume, in the flexural capacity of HSC beam. Thirteen members with dimensions of 0.3 m width, 0.15 m depth and 0.9 m span length were utilized in this work. A comparison study was performed considering HSC members and hybrid beams fabricated by HSC and conventional normal concrete (CC). In addition to the experiments on the influence of glass powder on flexural behavior, numerical analysis was implemented using nonlinear finite element approach to simulate the structural performance of the beams. Same constitutive relationships were selected to model the behavior of HSC with waste glass powder or silica fume to show the matching between the modeling outputs for beams made with these powders. The results showed that the loading capacity and ductility index of the HSC beams with waste glass powder demonstrated enhancing ultimate load and ductility compared with those of HSC specimens with silica fume. The study deduced that the recycled waste glass powder is a good alternative to the pozzolanic powder of silica fume.

Review study towards effect of Silica Fume on the fresh and hardened properties of concrete

  • Imam, Ashhad;Kumar, Vikash;Srivastava, Vikas
    • Advances in concrete construction
    • /
    • v.6 no.2
    • /
    • pp.145-157
    • /
    • 2018
  • This paper presents a review on the use of Silica Fume (SF) as a mineral admixture in the concrete. Distinctive outcome from several researches have been demonstrated here, particularly emphasizing on the fresh and hardened properties of concrete when blended with Silica Fume (Micro-silica or Nano-silica). The results showed a substantial enhancement in the mechanical properties of concrete when replaced with SF. The review also presented a brief idea of percentage replacement of SF in case of normal and high-strength concrete. A decreasing trend in workability (slump value) has been identified when there is a increase in percentage replacement of SF. It can be concluded that the optimize percentage of replacement with SF lies in the range of 8-10% particularly for compressive strength. However the variation of blending goes up to 12-15% in case of split tensile and flexure strength of concrete. The study also demonstrates the effect of silica fume on durability parameters like water absorption, permeability, sulphate attack and chloride attack.

Experimental Study on the Strength Improvement and the Long Term Durability of Shotcrete mixed Micro-Silica Fume (실리카 흄을 혼입한 숏크리트의 강도증진과 장기내구특성에 관한 실험적 연구)

  • Ma, Sang-Joon;Kim, Dong-Min;Jang, Phil-Sung;Choi, Jae-Seok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.2
    • /
    • pp.165-182
    • /
    • 2006
  • In this study, field test was performed to investigate the strength-improvement effect of shotcrete mixed Micro-silica fume and shotcrete quality was estimated by EFNARC standard. Deterioration test combined the Freezing-thawing and Carbonation was also performed in order to investigate a long-term durability of high-strength shotcrete. As a result of test, the compressive strength of shotcrete using Micro-silica fume was 45.2~55.8MPa and flexible strength was 5.01~6.66MPa, so a promotion ratio of strength was 37~79%, 17~61% respectively. And the strength-improvement effect of strength by silica fume addition ratio of 7.5~10% for cement mass was more superior to the others. Due to relative dynamic modulus, mass decrease rate and carbonation progress of shotcrete mixed Micro-silica fume, it was especially realized that Micro-silica fume reduced deterioration caused by steel fiber and improved a long-term durability of shotcrete.

  • PDF

Microstructural Investigation on the Deterioration of Silica Fume Blended Cement Matrix Under Magnesium Sulfate Attack (황산마그네슘 침식을 받은 실리카 퓸 혼합 시멘트 경화체의 성능저하에 대한 미세구조적 관찰)

  • Lee, Seung-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.55-62
    • /
    • 2008
  • This paper reports the effect of replacement levels of silica fume on the resistance to magnesium sulfate attack. Mortar specimens incorporating silica fume were exposed to 5% magnesium sulfate solution for 360 days at ambient temperature. The main variable was the replacement levels of silica fume(0, 5, 10 and 15% of cement by mass). The resistance of mortar specimens incorporating silica fume against magnesium sulfate attack was regularly monitored by measuring compressive strength and expansion. In addition, in order to investigate the reactants formed by magnesium sulfate attack, various instrumental analyses such as XRD, SEM and DSC were used. Results demonstrated that the formation of gypsum, thaumasite and brucite led to a significant deterioration due to magnesium sulfate attack in cement matrix incorporating silica fume.

Mechanical Properties of Concrete Using Metakaolin and Silicon Dioxide (메타카올린 및 이산화규소를 활용(活用)한 콘크리트의 역학적(力學的) 특성(特性))

  • Kim, Nam-Wook;Kim, Chun-Ho
    • Resources Recycling
    • /
    • v.21 no.2
    • /
    • pp.47-52
    • /
    • 2012
  • According to the diversification of types of concrete structures, the quality of the concrete which is demanded also, is becoming high performance essentially. The high performance of the concrete leads using of admixtures, generally, in order to produce high strength, concrete has been used to silica fume. Silica fume is excellent mechanical properties, but unlikely to be economic. So, recently as a replacement for silica fume, metakaolin is a lot of research underway. In this study, it is used the metakaolin substitute for silica fume. For in order to prevent loss of liquidity when occurs using the admixtures, we used the silica dioxide. Therefore, concrete with the admixtures and silicon dioxide were examined the mechanical properties.

Properties of Ternary or Quaternary High Strength Concrete Using Silica Fume & Meta Kaolin (실리카퓸과 메타카올린을 사용한 다성분계 고강도콘크리트의 특성)

  • Park, Cho-Bum;Kim, Ho-Su;Jeon, Jun-Young;Kim, Eun-Kyum;Ryu, Deug-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.307-315
    • /
    • 2008
  • In this study, it is investigated the properties of high strength concrete using mineral admixture, on the purpose of use of meta kaolin for the substitutive materials to silica fume which is so expensive. The plain mixtures are 3 degrees which are ordinary portland cement, blast furnace slag cement and OPC included fly ash 20%, and silica fume and meta kaolin are substituted for the each plain mixtures in the range of 20%. The results of experiment showed as follows. In case of silica fume was only used, the viscosity and slump flow of fresh concrete were much decreased, on the contrary air content increased. But as usage of meta kaolin increased, to being increase the viscosity of fresh concrete, slump flow increased and air content and usage of super-plasticizer were decreased. Accordingly the workabilities of concrete were against tendency between silica fume and meta kaolin. The compressive strength, velocity of ultrasonic pulse and unit weight were increased according to usage of meta kaolin, the properties of hardened concrete were judged that they are affected with air content of fresh concrete, so it is very important to control air content of high strength concrete. Therefore, the use of meta kaolin is prospected to the substitutive material of silica fume, in case of using silica fume and meta kaolin, it is judged that the optimum usage of silica fume and meta kaolin is about 10% respectively, considering workability and strength of concrete.

An Experimental Study on the Effect on Strength and Internal Structure for UHPC by Silics Fume Replacement Ratio (실리카 퓸의 첨가량에 따른 UHPC의 강도와 내부조직에 미치는 영향에 관한 실험적 연구)

  • Park, Jung-Jun;Kang, Su-Tae;Ryu, Gum-Sung;Koh, Gyung-Taek;Kim, Sung-Wook;Lee, Jang-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.765-768
    • /
    • 2008
  • Silica fume is a very important gradient in UHPC(Ultra High Performance Concrete) and its amount is normally over 25% of cement(wt.%). But we surely need to comprehend the influence of the amount of silica fume on the UHPC. In this paper, it was investigated how the amount of silica fume influence on the properties such as fluidity, compressive strength, elastic modulus, and flexural strength. Furthermore, it was examined the internal micro structure on UHPC through the test of SEM and MIP. In results, If we properly use silica fume in UHPC, fluidity and strength of UHPC was increased. It can be ascertained through the test of MIP that silica fume effectively increased density of UHPC by posolanic reaction and acting as filler. Especially, In case of Cement to silica fume ratio$0.1{\sim}0.25%$, we can be concluded that UHPC has similar to mechanical property.

  • PDF

Modeling of ultimate value and kinetic of compressive strength and hydration heat of concrete made with different replacement rates of silica fume and w/b ratios

  • Djezzar, Mahdjoub;Ezziane, Karim;Kadri, Abdelkader;Kadri, El-Hadj
    • Advances in concrete construction
    • /
    • v.6 no.3
    • /
    • pp.297-309
    • /
    • 2018
  • The objective of this study was to evaluate the influence of silica fume (SF) on the hydration heat and compressive strength of concrete. Portland cement with w/(c+sf) ratios varying between 0.25 to 0.45 was substituted by 10%, 20% and 30% of SF by mass. A superplasticizer was used to maintain a fluid consistency of the concrete. The heat of hydration was monitored continuously by a semi-adiabatic calorimetric method for 10 days at $20^{\circ}C$. Compressive strengths are tested for each mixture until age of 180 days. The results show that silica fume considerably influences the evolution and the ultimate values of the compressive strengths as well as the hydration heat especially for 10% rate. The w/b ratio has a considerable effect where its decrease modifies compressive strength and hydration heat more than silica fume. The correlation of the obtained results allows deducing of ultimate properties as well as the ages to reach half of their values. The correlation coefficients are close to unity and reflect the judicious choice of these relationships to be used to predict compressive strength and hydration heat.

Axial compression behavior of circular recycled concrete-filled steel tubular short columns reinforced by silica fume and steel fiber

  • Chen, Juan;Liu, Xuan;Liu, Hongwei;Zeng, Lei
    • Steel and Composite Structures
    • /
    • v.27 no.2
    • /
    • pp.193-200
    • /
    • 2018
  • This paper presents an experimental work for short circular steel tube columns filled with normal concrete (NAC), recycled aggregate concrete (RAC), and RAC with silica fume and steel fiber. Ten specimens were tested under axial compression to research the effect of silica fume and steel fiber volume percentage on the behavior of recycled aggregate concrete-filled steel tube columns (RACFST). The failure modes, ultimate loads and axial load- strain relationships are presented. The test results indicate that silica fume and steel fiber would not change the failure mode of the RACFST column, but can increase the mechanical performances of the RACFST column because of the filling effect and pozzolanic action of silica fume and the confinement effect of steel fiber. The ultimate load, ductility and energy dissipation capacity of RACFST columns can exceed that of corresponding natural aggregate concrete-filled steel tube (NACFST) column. Design formulas EC4 for the load capacity NACFST and RACFST columns are proposed, and the predictions agree well with the experimental results from this study.