• Title/Summary/Keyword: Significant Motion Sensor

Search Result 44, Processing Time 0.03 seconds

Significant Motion-Based Adaptive Sampling Module for Mobile Sensing Framework

  • Muthohar, Muhammad Fiqri;Nugraha, I Gde Dharma;Choi, Deokjai
    • Journal of Information Processing Systems
    • /
    • v.14 no.4
    • /
    • pp.948-960
    • /
    • 2018
  • Many mobile sensing frameworks have been developed to help researcher doing their mobile sensing research. However, energy consumption is still an issue in the mobile sensing research, and the existing frameworks do not provide enough solution for solving the issue. We have surveyed several mobile sensing frameworks and carefully chose one framework to improve. We have designed an adaptive sampling module for a mobile sensing framework to help solve the energy consumption issue. However, in this study, we limit our design to an adaptive sampling module for the location and motion sensors. In our adaptive sampling module, we utilize the significant motion sensor to help the adaptive sampling. We experimented with two sampling strategies that utilized the significant motion sensor to achieve low-power consumption during the continuous sampling. The first strategy is to utilize the sensor naively only while the second one is to add the duty cycle to the naive approach. We show that both strategies achieve low energy consumption, but the one that is combined with the duty cycle achieves better result.

Measurement of a Six-degree-of-freedom Dynamic Characteristics using Angle Sensor-Implemented Grating Interferometry (회절격자 간섭계를 이용한 초정밀 스테이지의 6 자유도 운동 특성 측정)

  • Lee, Cha-Bum;Kim, Gyu-Ha;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.906-912
    • /
    • 2012
  • This paper presents the new method for a six-degree-of-freedom (DOF) motion measurement and those dynamic characterizations in an ultraprecision linear stage using angle sensor-implemented grating interferometry. It consists of a diffractive optical element, a corner cube, four separate two-dimensional position sensitive detectors, four photodiodes and auxiliary optics components. From the previous study, it was confirmed that the proposed optical system could measure a six-DOF motion error in a linear stage. In this article, six-DOF motion dynamic characteristics of the stage were investigated through the step response and with respect to the conditions with a different speed of a slide table. As a result, the natural frequency and damping ratio according to a six-DOF direction was obtained. Also, it was seen that the speed of slide table had an significant effect on a six-DOF displacement motion, especially, X, which was considered as the effect of friction mechanism and local elastic mechanical deformation in a slide guide.

Development an embedded module for nondirectional wave spectrum analysis

  • Park, Soo-Hong;Wong, Sheng-Chao
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.454-461
    • /
    • 2008
  • This embedded module measures significant wave height and zero crossing periods through spectral energy from a record of time series heave motion. An ARM7TDMI core microcontroller serves as the main control unit which performs the appropriate control and signal conditioning. Monitored wave characteristic is transmitted with satellite modem. Mathematical equations on signal conditioning and experiments procedures are documented in this paper.

Development of Bib Pants Design and Pattern for Cycling Smart Wear (사이클링 스마트웨어 제작을 위한 빕 팬츠 디자인 및 패턴 개발)

  • Yunyoung, Kim;Byeongha, Ryu;Woojae, Lee;Kikwang, Lee;Rira, Kim
    • Journal of Fashion Business
    • /
    • v.26 no.5
    • /
    • pp.91-104
    • /
    • 2022
  • In this study, a cycling smart wear for measuring cycling posture and motion was developed using a three-dimensional motion analysis camera and an IMU inertial sensor. Results were compared according to parts to derive the optimal smart device attachment location, enabling correct posture measurement and cycle motion analysis to design a pattern. Conclusions were as follows: 1) 'S-T8' > 'S-T10' > 'S-L4' was the most significant area for each lumbar spine using a 3D motion analysis system with representative posture change (90°, 60°, 30°) to derive incisions and size specifications; 2) the part with the smallest relative angle change among significant section reference points during pattern design was applied as a reference point for attaching a cycling smart device to secure detachable safety of the device. Optimal locations for attaching the cycling device were the "S-L4" hip bone (Sacrum) and lumbar spine No. 4 (Lumbar 4th); 3) the most suitable sensor attachment location for monitoring knee induction-abduction was the anatomical location of the rectus femoris; 4) a cycling smart wear pattern was developed without incision in the part where the sensor and electrode passed. The wearing was confirmed with 3D CLO. This study aims to provide basic research on exercise analysis smart wear, to expand the smart cycling area that could only be realized with smart devices and smart watches attached to current cycles, and to provide an opportunity to commercialize it as cycling smart wear.

A Study on the Performance Improvement of Position Estimation using the Multi-Sensor Fusion in a Combat Vehicle (다중센서 융합을 통한 전투차량의 위치추정 성능 개선에 관한 연구)

  • Nam, Yoonwook;Kim, Sungho;Kim, Kitae;Kim, Hyoung-Nam
    • Journal of Korean Society for Quality Management
    • /
    • v.49 no.1
    • /
    • pp.1-15
    • /
    • 2021
  • Purpose: The purpose of this study was to propose a sensor fusion algorithm that integrates vehicle motion sensor(VMS) into the hybrid navigation system. Methods: How to evaluate the navigation performance was comparison test with the hybrid navigation system and the sensor fusion method. Results: The results of this study are as follows. It was found that the effects of the sensor fusion method and α value estimation were significant. Applying these greatly improves the navigation performance. Conclusion: For improving the reliability of navigation system, the sensor fusion method shows that the proposed method improves the navigation performance in a combat vehicle.

Comparison of Knee Muscle Strength and Ankle Dorsiflexion Range of Motion Between Standing Workers With and Without Patellofemoral Pain Syndrome

  • Weon, Young-soo;Ahn, Sun-hee;Kim, Jun-hee;Gwak, Gyeon-tae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.241-249
    • /
    • 2020
  • Background: Prolonged standing during work causes a lower extremity pain and disorders. Patellofemoral pain syndrome (PFPS) is one of the common diagnoses of the knee pain. Although the etiology of PFPS is not completely understood, it is considered to be multifactorial. Objects: The purpose of this study was to investigate difference in strength of knee muscles, quadriceps:hamstring muscles strength ratio (Q:H ratio), asymmetry ratio of knee muscles strength and dorsiflexion range of motion (ROM) between standing workers with and without PFPS. Methods: Twenty-eight standing workers with PFPS and 26 age-, height-, and weight-matched standing workers without PFPS participated in this study. A tension sensor measured knee muscle strength, and motion sensor measured dorsiflexion ROM. The asymmetry ratio of knee muscles was calculated by a specific formula using the knee muscles strength of the dominant side and the sound side. An independent t-test was used to identify significant differences in the strength, ROM, Q:H ratio, and asymmetry ratio between the PFPS and normal groups. Results: The standing worker with PFPS have significantly lower dorsiflexion ROM (p < 0.000) and higher asymmetry ratio of the hamstring muscles strength (p < 0.000) compare to the standing worker without PFPS. No significant differences were seen in the strength of quadriceps muscle and hamstring muscles, Q:H ratio, and asymmetry ratio of quadriceps muscle strength. Conclusion: There was a significant difference in the asymmetry ratio of the isometric hamstring muscle strength. This finding suggests that the asymmetry ratio of isometric hamstring muscle strength may be more important than measuring only the hamstring muscle strength of the PFPS side. Furthermore, the results of this study showed a significant difference in dorsiflexion ROM between the standing industrial workers with and without PFPS. Dorsiflexion ROM and isometric hamstring muscle strength should be considered when evaluating the subjects with PFPS.

Analysis of 3D Motion Recognition using Meta-analysis for Interaction (기존 3차원 인터랙션 동작인식 기술 현황 파악을 위한 메타분석)

  • Kim, Yong-Woo;Whang, Min-Cheol;Kim, Jong-Hwa;Woo, Jin-Cheol;Kim, Chi-Jung;Kim, Ji-Hye
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.925-932
    • /
    • 2010
  • Most of the research on three-dimensional interaction field have showed different accuracy in terms of sensing, mode and method. Furthermore, implementation of interaction has been a lack of consistency in application field. Therefore, this study is to suggest research trends of three-dimensional interaction using meta-analysis. Searching relative keyword in database provided with 153 domestic papers and 188 international papers covering three-dimensional interaction. Analytical coding tables determined 18 domestic papers and 28 international papers for analysis. Frequency analysis was carried out on method of action, element, number, accuracy and then verified accuracy by effect size of the meta-analysis. As the results, the effect size of sensor-based was higher than vision-based, but the effect size was extracted to small as 0.02. The effect size of vision-based using hand motion was higher than sensor-based using hand motion. Therefore, implementation of three-dimensional sensor-based interaction and vision-based using hand motions more efficient. This study was significant to comprehensive analysis of three-dimensional motion recognition for interaction and suggest to application directions of three-dimensional interaction.

Optimal Cylindrical Capacitive Sensor(CCS) taking into account the Circumferential Gaps between Sensor Electrodes (센서 전극 사이의 간극을 고려한 최적의 정전용량 센서)

  • Ahn, Hyeong-Joon;Park, Jong-Min;Han, Dong-Chul
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.613-618
    • /
    • 2004
  • CCS was developed and applied to rotating machines because of accurately measuring the spindle error motion without significant efforts. However, researches on the CCS have been focused on ideal cases where circumferential gaps were ignored. This paper presents the effects of circumferential gaps and proposes an optimal CCS considering the circumferential gaps. First, electrostatic analysis of the CCS that includes the circumferential gaps is performed using the FEM, and an additional capacitance due to the circumferential gap can be approximated as an equivalent extended sensor length. Second, a mathematical model of the CCS considering the circumferential gaps is derived, and the optimal CCS is determined through minimization of the weighted error amplification factor. Finally, two CCSs, both considering and ignoring the circumferential gaps, are built, and the effectiveness of the optimal design is verified through simulation and experiment.

  • PDF

A Study on the Analysis of 5-DOF Axis of Rotation Error in Low Speed Rotary Stage (저속 회전 스테이지의 5자유도 회전축 오차 분석에 관한 연구)

  • Han, Chang-Soo;Kim, Jin-Ho;Shin, Dong-Ik;Yun, Deok-Won;Lee, Yung-Gi;Lee, Sang-Moo;Nam, Gyung-Tai
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.23-27
    • /
    • 2007
  • Rotary stages in semiconductor, display industry and many other fields require challenging accuracy to perform their functions properly. Especially, Axis of rotation error on rotary system is significant; such as the spindle error motion of the aligner, wire bonder and inspector machine which result in the poor quality products. To evaluate and improve the performance of such precision rotary stage, undesired movements on the other 5 degrees of freedom of the rotary stage must be measured and analyzed. In this paper, we have measured the three translations and two tilt motions of the worm gear type spindle with high precision capacitive sensors. To obtain the radial error motion, we have used Donaldson's reversal technique. And the axial components of the spindle tilt error motion can be obtained accurately from the axial direction outputs of sensors by Estler face motion reversal technique. Further more we have designed and developed the sensor mounting jig with standard cylinder for reversal method.

  • PDF

Using a Stretch Sensor About of Squat Ankle Range of Motion Check Socks -Focusing on Men in Their Late 20s- (스트레치 센서를 이용한 스쿼트 시 발목 가동범위 체크 센서 양말에 관하여 -20대 후반 남성을 중심으로-)

  • Song, Kwanwoo;Park, Jinhee;Kim, Jooyong
    • Journal of Fashion Business
    • /
    • v.26 no.2
    • /
    • pp.129-142
    • /
    • 2022
  • The purpose of this study is to develop socks to check the range of ankle movement during squats for men in their late 20s. Sensors of 6, 8, and 12 mm were selected, and each sample was impregnated 1 to 3 times. It was prepared using a CNT dispersion, and the GF value was measured using UTM. Among them, the sample with 2 impregnation showed the best GF value. As a result of applying each sample to the socks, the 12 mm sensor was wider than the area of the Achilles tendon, resulting in noise, and the 8 mm sensor was higher than the tensile strength of the socks, resulting in a decrease in the graph. Therefore, testing was performed using a 6 mm sensor. In order to determine the effectiveness of the sensor, the normal operating range was checked through squats, and significant changes were confirmed when the operating range was checked again through squats by performing operations that can increase the operating range through Gastrocnemius, Soleus stretching, and low lunge. Using the results of this study, it is expected that the average value of the ankle movement range of the user is checked prevent injury, to be provided as basic data for the production of shoe products and the promotion of physical health.