• Title/Summary/Keyword: Signed distance method

Search Result 30, Processing Time 0.022 seconds

Design of a Fuzzy Logic Controller for a Rotary-type Inverted Pendulum System

  • Park, Byung-Jae;Ryu, Chun-ha;Choi, Bong-Yeol
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.2 no.2
    • /
    • pp.109-114
    • /
    • 2002
  • Various inverted pendulum systems have been frequently used as a model for the performance test of the proposed control system. We first identify a rotary-type inverted pendulum system by the Euler-Lagrange method and then design a FLC (Fuzzy Logic Controller) fur the plant. FLC`s are one of useful control schemes fur plants having difficulties in deriving mathematical models or having performance limitations with conventional linear control schemes. Many FLC`s imitate the concept of conventional PD (Proportional-Derivative) or PI (Proportional-Integral) controller. That is, the error e and the change-of-error are used as antecedent variables and the control input u the change of control input Au is used as its consequent variable for FLC`s. In this paper we design a simple-structured FLC for the rotary inverted pendulum system. We also perform some computer simulations to examine the tracking performance of the closed-loop system.

Analysis on Spatial Sampling and Implementation for Primal Trees (Primal Tree의 공간 분할 샘플링 분석 및 구현)

  • Park, Taejung
    • Journal of Digital Contents Society
    • /
    • v.15 no.3
    • /
    • pp.347-355
    • /
    • 2014
  • The general octree structure is common for various applications including computer graphics, geometry information analysis and query. Unfortunately, the general octree approach causes duplicated sample data and discrepancy between sampling and representation positions when applied to sample continuous spatial information, for example, signed distance fields. To address these issues, some researchers introduced the dual octree. In this paper, the weakness of the dual octree approach will be illustrated by focusing on the fact that the dual octree cannot access some specific continuous zones asymptotically. This paper shows that the primal tree presented by Lefebvre and Hoppe can solve all the problems above. Also, this paper presents a three-dimensional primal tree traversal algorithm based the Morton codes which will help to parallelize the primal tree method.

Augmentation of Fractional-Order PI Controller with Nonlinear Error-Modulator for Enhancing Robustness of DC-DC Boost Converters

  • Saleem, Omer;Rizwan, Mohsin;Khizar, Ahmad;Ahmad, Muaaz
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.835-845
    • /
    • 2019
  • This paper presents a robust-optimal control strategy to improve the output-voltage error-tracking and control capability of a DC-DC boost converter. The proposed strategy employs an optimized Fractional-order Proportional-Integral (FoPI) controller that serves to eliminate oscillations, overshoots, undershoots and steady-state fluctuations. In order to significantly improve the error convergence-rate during a transient response, the FoPI controller is augmented with a pre-stage nonlinear error-modulator. The modulator combines the variations in the error and error-derivative via the signed-distance method. Then it feeds the aggregated-signal to a smooth sigmoidal control surface constituting an optimized hyperbolic secant function. The error-derivative is evaluated by measuring the output-capacitor current in order to compensate the hysteresis effect rendered by the parasitic impedances. The resulting modulated-signal is fed to the FoPI controller. The fixed controller parameters are meta-heuristically selected via a Particle-Swarm-Optimization (PSO) algorithm. The proposed control scheme exhibits rapid transits with improved damping in its response which aids in efficiently rejecting external disturbances such as load-transients and input-fluctuations. The superior robustness and time-optimality of the proposed control strategy is validated via experimental results.

Level Set Method Applied on Pseudo-compressibility Method for the Analysis of Two-phase Flow (Pseudo-compressibility 방법에서 이상유동 해석을 위한 Level Set방법의 적용)

  • Ihm Seung-Won;Kim Chongam;Shim Jae-Seol;Lee Dong-Young
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.3
    • /
    • pp.158-165
    • /
    • 2005
  • In order to analyze incompressible two-phase flow, Level Set method was applied on pseudo-compressibility formulation. Level Set function is defined as a signed distance function from the phase interface, and gives the information of the each phase location and the geometric data to the flow. In this study, Level Set function transport equation was coupled with flow conservation equations, and owing to pseudo-compressibility technique we could solve the resultant vector equation iteratively. Two-phase flow analysis code was developed on general curvilinear coordinate, and numerical tests of bubble dynamics and surging wave problems demonstrate its capability successfully.

Enhanced Dual Contouring method by using the Feature of Spherical Coordinate System (구면 좌표계의 특성을 이용한 듀얼 컨투어링 기법 개선)

  • Kim, Jong-Hyun;Park, Tae-Jung;Kim, Chang-Hun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.17 no.2
    • /
    • pp.27-36
    • /
    • 2011
  • The Dual Contouring method has an advantage over the primal polygonization methods like the Marching Cube method in terms of better expression of sharp features. In this paper, the Dual Contouring method is implemented in Spherical coordinates, not the Cartesian ones to examine some characteristics. For this purpose, our octree is defined in Spherical coordinates, which is called "S-Octree". Among some characteristics, the proposed Dual Contouring method in the S-Octree tends to produce less vertices at the same octree level. In particular, for any surface models close to surface sphere, the generated mesh surfaces are smoother and more detailed than those of the Cartesian Dual Contouring approach for specific applications including mesh compression where available geometric information is quite limited.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Skeletal and dentoalveolar changes after miniscrew-assisted rapid palatal expansion in young adults: A cone-beam computed tomography study

  • Park, Jung Jin;Park, Young-Chel;Lee, Kee-Joon;Cha, Jung-Yul;Tahk, Ji Hyun;Choi, Yoon Jeong
    • The korean journal of orthodontics
    • /
    • v.47 no.2
    • /
    • pp.77-86
    • /
    • 2017
  • Objective: The aim of this study was to evaluate the skeletal and dentoalveolar changes after miniscrew-assisted rapid palatal expansion (MARPE) in young adults by cone-beam computed tomography (CBCT). Methods: This retrospective study included 14 patients (mean age, 20.1 years; range, 16-26 years) with maxillary transverse deficiency treated with MARPE. Skeletal and dentoalveolar changes were evaluated using CBCT images acquired before and after expansion. Statistical analyses were performed using paired t-test or Wilcoxon signed-rank test according to normality of the data. Results: The midpalatal suture was separated, and the maxilla exhibited statistically significant lateral movement (p < 0.05) after MARPE. Some of the landmarks had shifted forwards or upwards by a clinically irrelevant distance of less than 1 mm. The amount of expansion decreased in the superior direction, with values of 5.5, 3.2, 2.0, and 0.8 mm at the crown, cementoenamel junction, maxillary basal bone, and zygomatic arch levels, respectively (p < 0.05). The buccal bone thickness and height of the alveolar crest had decreased by 0.6-1.1 mm and 1.7-2.2 mm, respectively, with the premolars and molars exhibiting buccal tipping of $1.1^{\circ}-2.9^{\circ}$. Conclusions: Our results indicate that MARPE is an effective method for the correction of maxillary transverse deficiency without surgery in young adults.

The Immediate Effect of the Backward Walking Exercise and Verbal Command on the Forward Head Posture of College Students in their 20s (뒤로 걷기 운동과 언어 지시가 20대 대학생들의 앞쪽 머리 자세에 미치는 즉각적인 효과)

  • Park, Han-kyu;Kim, Tae-ho;Kim, Dong-woo
    • Physical Therapy Korea
    • /
    • v.27 no.3
    • /
    • pp.185-190
    • /
    • 2020
  • Background: Backward walking exercise may offer some unique and potentially beneficial differences compared with forward walking exercise. There is still a lack of research on backward walking exercises and forward head posture. Objects: The purpose of this study was to determine the effect of backward walking exercise on college students forward head posture in their 20s. Methods: Twenty-one subjects participated in the experiment. The subjects were those with a craniovertebral angle (CVA) of 55 degrees or less who understood the purpose and method of this study and voluntarily agreed. A camera capable of taking pictures of the lateral plane was installed at a distance of 1.5 meters before exercising. Pictures were taken before walking backward, and after walking for 15 minutes on the treadmill, the images were taken in the same way. The composition of the backward walking exercise was walking at a rate of 1.0 for 5 minutes, and the remaining 10 minutes were walking at a rate of 1.5. Wilcoxon signed rank test was used to compare CVA and craniorotational angle (CRA) before and after exercise. Results: As a result of this study, there was a significant difference in CVA before and after exercise (p < 0.05). There was a significant difference in CRA before and after exercise (p < 0.05). Conclusion: The backward walking exercise and verbal command seems to have positively influenced the changes in CVA and CRA among college students in their 20s. It seems that studies to confirm balance or muscle activity as well as changes in forward head posture through the long-term intervention of the backward walking exercise should be conducted.

Visual Feedback System for Manipulating Objects Using Hand Motions in Virtual Reality Environment (가상 환경에서의 손동작을 사용한 물체 조작에 대한 시각적 피드백 시스템)

  • Seo, Woong;Kwon, Sangmo;Ihm, Insung
    • Journal of the Korea Computer Graphics Society
    • /
    • v.26 no.3
    • /
    • pp.9-19
    • /
    • 2020
  • With the recent development of various kinds of virtual reality devices, there has been an active research effort to increase the sense of reality by recognizing the physical behavior of users rather than by classical user input methods. Among such devices, the Leap Motion controller recognizes the user's hand gestures and can realistically trace the user's hand in a virtual reality environment. However, manipulating an object in virtual reality using a recognized user's hand often causes the hand to pass through the object, which should not occur in the real world. This study presents a way to build a visual feedback system for enhancing the user's sense of interaction between hands and objects in virtual reality. In virtual reality, the user's hands are examined precisely by using a ray tracing method to see if the virtual object collides with the user's hand, and when any collision occurs, visual feedback is given through the process of reconstructing the user's hand by moving the position of the end of the user's fingers that enter the object through sign distance field and reverse mechanics. This enables realistic interaction in virtual reality in real time.

An Investigation on the Effects of Wet Cupping on Wisu (BL21) for Non-acute Low Back Pain: A Pilot Randomized Controlled Trial (비급성 요통에 대한 위수혈 자락관법의 효과 탐색: 예비 무작위 대조군 시험)

  • Kim, Hyungsuk;Cho, Jae-Heung;Kim, Koh-Woon;Chung, Won-Seok;Park, Jae-Hyun;Shin, Woo-Chul;Chung, Seok-Hee
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.4
    • /
    • pp.21-32
    • /
    • 2018
  • Objectives This study was designed to investigate the effects of wet cupping on Wisu (BL12) in non-acute low back pain patients. Methods We recruited 30 participants for this study. Fifteen patients were randomly assigned to the Wisu (BL21) treatment group (WT group) and 15 were assigned to the non-acupoint treatment group (NT group). Both groups were treated with the pricking-cupping bloodletting method three times. Values at baseline and follow-up were analyzed by Wilcoxon signed rank test and the differences between the two groups were determined by Wilcoxon rank sum test. p-values less than 0.05 were considered significant. The primary outcome was the visual analogue scale (VAS), and secondary outcomes were the Oswestry disability index (ODI), Rolland-Morris disability questionnaire (RMDQ), Euroqol-5 dimension questionnaire (EQ-5D) and finger-to-ground distance (FTGD). These outcomes were measured on the day of first treatment before the procedure and on follow-up 7 days after the last treatment. Results Significant changes were identified in the VAS for pain and ODI in each group after wet cupping treatment on Wisu (p<0.05). However, no significant changes were found between groups. Meanwhile, RMDQ and EQ-5D were significantly decreased only in the NT group (p<0.05) without any differences between groups. FTGD was decreased in both groups, but not significantly. Conclusions Wet cupping with both Wisu treatment and non-acupoint had significant effects on non-acute low back pain, although there were no differences between the two groups. A large-scale study is needed to identify the effect of wet cupping on Wisu.