• Title/Summary/Keyword: Signal transfer method

Search Result 315, Processing Time 0.025 seconds

An adjustment of coefficients for SMAC using MODIS red band (MODIS 가시 채널을 사용한 SMAC 계수 개선)

  • Park, Soo-Jae;Lee, Chang-Suk;Yeom, Jong-Min;Lee, Ga-Lam;Pi, Kyoung-Jin;Han, Kyung-Soo;Kim, Young-Seup
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.254-259
    • /
    • 2009
  • In this study, Simplified Method for the Atmospheric Correction (SMAC) radiative transfer model (RTM) used to retrieve surface reflectance from MODIS Top Of Atmosphere (TOA) reflectance (MOD02). SMAC code provides coefficients which were previously yielded by Second Simulation of the Satellite Signal in the Solar Spectrum (6S) for each satellite sensor. We conducted error analysis of SMAC RTM using MOD02 over comparison with MODIS surface reflectance (MOD09) which was provided from 6S. It showed that low accuracy values such as, $R^2$ : 0.6196, Root Means Square Error (RMSE) : 0.00031, bias : - 0.0859. Thus sensitivity analysis of input parameters and coefficients was conducted to searching error sources. Coefficients about $\tau_p$ (average AOD) are more influence than any other coefficients of $\tau_{a550}$ (Aerosol Optical Depth at 550nm) from sensitivity test. Calibrated coefficients of $\tau_p$ from regression analysis were used to surface reflectance which showed that improve accuracy of surface reflectance ($R^2$ : 0.827, RMSE : 0.00672, bias : - 0.000762).

  • PDF

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

A Time Comparison Measurement Technique for eLoran Receivers (시각비교를 위한 eLoran 수신기 지연측정 기술)

  • Lee, Chang-Bok;Lee, Jong-Koo;Lee, Young-Kyu;Hwang, Sang-wook;Yang, Sung-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.40 no.6
    • /
    • pp.385-390
    • /
    • 2016
  • ELoran Systems can provide Position, Navigation, and Time services with comparable performance to Global Positioning Systems (GPS) as a back up or alternative system. High timing and navigation performance can be achieved by eLoran signals because eLoran receivers use "all-in-view" reception. This incorporates Time of Arrival (TOA) signals from all stations in the service range because each eLoran station is synchronized to Coordinated Universal Time (UTC). Transmission station information and the differential Loran correction data are transmitted via an additional Loran Data Channel (LDC) on the transmitted eLoran signal such that eLoran provides improved Position Navigation and Timing (PNT) over legacy Loran. In this paper, we propose a technique for adapting the delay time compensation values in eLoran timing receivers to provide precise time comparison. For this purpose, we have designed a system that measures time delay from the crossing point of the third cycle extracted from the current transformer at the end point of the transmitter. The receiver delay was measured by connecting an active H-field, an E-field and a passive loop antenna to a commercial eLoran timing receiver. The common-view time transfer technique using the calibrated eLoran timing receiver improved the eLoran transfer time. A eLoran timing receiver calibrated by this method can be utilized in the field for precise time comparison as a GNSS backup.

Apoptosis in the Bovine Blastocyst following Nnclear Transfer and In Vitro Fertilization (핵치환과 체외수정에 유래된 소의 배반포에서의 Apoptosis)

  • Kim, . E.H;D.W. Han;K.S. Chung;Lee, H.T.
    • Korean Journal of Animal Reproduction
    • /
    • v.26 no.2
    • /
    • pp.173-182
    • /
    • 2002
  • The mechanisms underlying of the visual assessment and resulting in optimum embryonic development following in vitro maturation, fertilization, and culture are unclear, It was known that in vitro produced embryos show more frequent occurrence of fragmentation, which resulted in poor developmental potential and decreased implantation rate. The objective of this study was to investigate the apoptotic rates in bovine blastocyst derived from in vitro fertilization (IVF) and nuclear transfer (NT). In addition, the expression levels of Bcl-2 and Bax gene were investigated in the blastocyst to confirm their potential roles in the regulation of apoptosis during preimplantation embryonic development. Analysis of apoptosis was carried out by using terminal deoxynucleotidyl transferase mediate dUTP nick end labeling (TUNEL) method. The levels of Bcl-2 and Bax gene in the blastocyst derived from IVF and NT were determined by RT-PCR. The proportion of TUNEL positive signal in blastocyst derived from NT was significantly higher than that in blastocyst derived from IVF (p<0.001). Bcl-2 expression level of blastocyst derived from IVF was higher than that of blstocyst derived from NT. However, high expression level of Bax was observed in the blastocyst derived from NT. These results indicates that apoptosis is more responsible for fiagmentation in bovine blastocyst derived from NT than IVF. These results suggested that the increase of developmental failure followed by NT could be caused by nuclear fragmentation as apoptosis.

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

A Design and Implementation of Process Controller for BMW (Bacteria Mineral Water) Plant (비엠 활성수 플랜트의 공정제어기 설계 및 구현)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.2
    • /
    • pp.74-82
    • /
    • 2015
  • In this study, a BMW plant process control system model which produces BMW is suggested and the BMW plant process controller with the following functions is developed. The first function is to operate the electronic overload relays to stop the blower for a certain period of time and to re-operate it again when the blower is overloaded. The second function is to close the motor operated valve automatically in case of power failure to prevent the circulation from the guided tank to the compost throwing tank and to block leak from the compost throwing tank due to the failure of ball valve. The third function is to transfer produced BMW from the concentration tank to 4 storage tanks for automatic managing of the BMW output. A device to measure the signal of the BMW plant process controller and a test equipment are developed. The designed BMW plant process controller is checked to see if it operates correctly according to the design specifications. The sequence control method based on BMW plant process controller is developed at a low cost in this study, so it is expected to bring improvements in the stability and the efficiency of system and to cause reductions in the operation and the management costs in the future.

Development of Flexible Glucose Measurement Sensor Based on Copper Nanocubes Electroplated Laser Induced Graphene Electrode (구리 나노 큐브를 전기 도금한 레이저 유도 그래핀 전극 기반의 글루코스 측정용 유연 센서 개발)

  • Kim, Geon-Jong;Kim, Taeheon;Pak, Jungho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.413-418
    • /
    • 2018
  • In this paper, we describe the development of a non-enzymatic glucose sensor based on copper nanocubes(Cu NCs) electroplated laser induced graphene(LIG) electrodes which can detect a certain range of glucose concentrations. $CO_2$ laser equipment was used to form LIG electrodes on the PI film. This fabrication method allows easy control of the LIG electrode size and shape. The Cu NCs were electrochemically deposited on the LIG electrodes to improve electron transfer rates and thus enhancing electrocatalytic reaction with glucose. The average sheet resistances before and after electroplating were $15.6{\Omega}/{\Box}$ and $19.6{\Omega}/{\Box}$, respectively, which confirmed that copper nanocubes were formed on the laser induced graphene electrodes. The prepared electrode was used to measure the current according to glucose concentration using an electrochemical method. The LIG electrodes with Cu NCs demonstrated a high degree of sensitivity ($1643.31{\mu}A/mM{\cdot}cm^2$), good stability with a linear response to glucose ranging from 0.05 mM to 1 mM concentration, and a limit of detection of 0.05 mM. In order to verify that these electrodes can be used as flexible devices, the electrodes were bent to $30^{\circ}$, $90^{\circ}$, and $180^{\circ}$ and cyclic voltammetry measurements were taken while the electrodes were bent. The measured data showed that the peak voltage was almost constant at 0.42 V and the signal was stable even in the flexed condition. Therefore, it is concluded that these electrodes can be used in flexible sensors for detecting glucose in the physiological sample like saliva, tear or sweat.

The Use of Artificial Neural Networks in the Monitoring of Spot Weld Quality (인공신경회로망을 이용한 저항 점용접의 품질감시)

  • 임태균;조형석;장희석
    • Journal of Welding and Joining
    • /
    • v.11 no.2
    • /
    • pp.27-41
    • /
    • 1993
  • The estimation of nugget sizes was attempted by utilizing the artificial neural networks method. Artificial neural networks is a highly simplified model of the biological nervous system. Artificial neural networks is composed of a large number of elemental processors connected like biological neurons. Although the elemental processors have only simple computation functions, because they are connected massively, they can describe any complex functional relationship between an input-output pair in an autonomous manner. The electrode head movement signal, which is a good indicator of corresponding nugget size was determined by measuring the each test specimen. The sampled electrode movement data and the corresponding nugget sizes were fed into the artificial neural networks as input-output pairs to train the networks. In the training phase for the networks, the artificial neural networks constructs a fuctional relationship between the input-output pairs autonomusly by adjusting the set of weights. In the production(estimation) phase when new inputs are sampled and presented, the artificial neural networks produces appropriate outputs(the estimates of the nugget size) based upon the transfer characteristics learned during the training mode. Experimental verification of the proposed estimation method using artificial neural networks was done by actual destructive testing of welds. The predicted result by the artifficial neural networks were found to be in a good agreement with the actual nugget size. The results are quite promising in that the real-time estimation of the invisible nugget size can be achieved by analyzing the process variable without any conventional destructive testing of welds.

  • PDF

Experimental Study of System Identification for Seismic Response of Building Structure (건축구조물의 지진응답제어를 위한 시스템 식별의 실험적 연구)

  • 주석준;박지훈;민경원;홍성목
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.4
    • /
    • pp.47-60
    • /
    • 1999
  • The stability and efficiency of structural control systems depend on the accuracy of mathematical model of the system to be controlled. In this study, state equation models of a small scale test structure and an AMD(active mass damper) are obtained separately using OKID(observer/Kalman filter identification) which is a time domain system identification method. The test structure with each floor acceleration as outputs is identified for two inputs - the ground acceleration and the acceleration of the moving mass of AMD relative to the installation floor - individually and the two identified state equation models are integrated into one by model reduction method. The AMD is identified with the motor control signal as an input and the relative acceleration of the moving mass as an output, and it is shown that the identified model has large damping ratio and phase shift. The transfer functions and the time histories reconstructed from the identified models of the test model and the AMD match well with those measured from the experiment.

  • PDF

A Study on the Computational Simulation of Cyclic Voltammetry using Semi-infinite Diffusion Model (반무한 확산모델을 이용한 순환전위법의 전산모사에 관한 연구)

  • Cho, Ha-Na;Kim, Tae-Yong;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.3
    • /
    • pp.138-144
    • /
    • 2011
  • The transport phenomena of electron and ion around the electrode have been analyzed, herein the computational program to simulate the electrochemical signal of cyclic voltammetry has been implemented. For the dominant mass-transfer system, the governing equation and its boundary conditions are confined to the semi-infinite diffusion model and the reversible reaction at the electrode. In order to obtain the numerical solutions of cyclic voltammetry, MATLAB was used for the explicit finite difference method. Experimental results from the cyclic voltammetry of electrochemical system(10 mM $K_3Fe(CN)_6$ and 0.1M KCl) upon the ITO glass substrate were compared with the numerical solutions. Present program explains the experimental results fairly well, where they approached the simulated ones closely with deceasing the scan rate. Furthermore, the effects of electrode area, electrochemical reaction constants and transfering coefficients in the cyclic voltammetry were discussed quantitatively.