• Title/Summary/Keyword: Signal to background ratio

Search Result 174, Processing Time 0.034 seconds

Design of a Single Pulse Laser Range Finder with Er:Yb:glass Microchip Lasers (어븀:이터븀:유리 마이크로칩 레이저를 이용한 단펄스 거리측정기 설계)

  • Koh, Hae Seog;Lee, Chang Jae;Park, Choong Bum;Jeon, Hyoung Ha;Ahn, Pil Dong;Park, Do Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.295-305
    • /
    • 2018
  • We present a passively Q-switched monolithic Er:Yb:glass microchip laser developed in our lab. The microchip laser can produce pulses at 1535 nm of the 'eye-safe' wavelengths with the pulse energy of 50 uJ and the pulse width of 4-6 ns. Using the laser we also designed and developed a pulsed Er:Yb:glass microchip laser rangefinder. Expressions for background and signal power, noise, and signal-to-noise ratio are reviewed. A computer simulation was used to optimize laser power, receiver aperture, and preamplifier bandwidth for the efficient system design of the laser rangefinder. Experimental results are presented to compare with the theory.

An Application of the Kalman Filter for Attenuation of Colored Noise Superimposed on Speech Signal (칼만필터를 이용한 음성신호에 중첩된 유색잡음의 감쇠)

  • Gu, Bon-Eung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.76-85
    • /
    • 1994
  • A speech enhancement algorithm which attenuates nonstationary colored noise is presented In this paper. The algorithm consists of a stationary Kalman filter and the simple speech/nonspeech detector. While the conventional enhancement systems are focused on a stationary and/or white background noise, this study Is focused on the mort realistic nonstationary and nonwhite noise. An AR model-based vector Kalman filter is used as a noise suppression system and a short-time energy threshold logic is used as a speech/nonspeech classifier. For Kalman filtering. noise coefficients are estimated in the nonspeech frame, and speech coefficients are estimated by applying the EM iteration algorithm. Simulation results using the car noise are presented based on the signal-to-noise ratio and informal listening tests. According to the experimental results, background noises in the nonspeech frames are eliminated almost completely, while some distortions are noticed in the speech frames. The distortion becomes severer as the SNR is reduced to 0dB and -5dB. Intelligibility, however, is not degraded significantly.

  • PDF

Analysis of Polycyclic Aromatic Hydrocarbons in Agricultural Soils by Gas Chromatography-Ion Trap Tandem Mass Spectrometry

  • Nam, Jae-Jak;Lee, Sang-Hak
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.113-118
    • /
    • 2003
  • An investigation has been carried out on collision-induced dissociation (CID) in the development of an analytical protocol for the determination of polycyclic aromatic hydrocarbons (PARs) by ion trap tandem mass spectrometry. Two different considerations were used to choose the optimal CID conditions for complex matrix environmental samples, namely, to determine the highest signal-to-noise (SIN) ratio and the other to eliminate the background interferences originated from complex matrix samples. The PAR content of agricultural soil was measured to estimate overall distribution of PAR in throughout the country, we collected and analyzed 226 soil samples from paddy and upland soil. The average content of total PAR in all samples was 236 ${\mu}g$ $kg^{-1}$, and the range was from 23.3 to 2, 834 ${\mu}g$ $kg^{-1}$. The overall distribution of PAR was found to be closely related to the pollution sources, the size of city and the type of industry.

  • PDF

Study on Dual-Energy Signal and Noise of Double-Exposure X-Ray Imaging for High Conspicuity

  • Song, Boram;Kim, Changsoo;Kim, Junwoo
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.160-169
    • /
    • 2021
  • Background: Dual-energy X-ray images (DEI) can distinguish or improve materials of interest in a two-dimensional radiographic image, by combining two images obtained from separate low and high energies. The concepts of DEI performance describing the performance of double-exposure DEI systems in the Fourier domain been previously introduced, however, the performance of double-exposure DEI itself in terms of various parameters, has not been reported. Materials and Methods: To investigate the DEI performance, signal-difference-to-noise ratio, modulation transfer function, noise power spectrum, and noise equivalent quanta were used. Low- and high-energy were 60 and 130 kVp with 0.01-0.09 mGy, respectively. The energy-separation filter material and its thicknesses were tin (Sn) and 0.0-1.0 mm, respectively. Noise-reduction (NR) filtering used the Gaussian-filter NR, median-filter NR, and anti-correlated NR. Results and Discussion: DEI performance was affected by Sn-filter thickness, weighting factor, and dose allocation. All NR filtering successfully reduced noise, when compared with the dual-energy (DE) images without any NR filtering. Conclusion: The results indicated the significance of investigating, and evaluating suitable DEI performance, for DE images in chest radiography applications. Additionally, all the NR filtering methods were effective at reducing noise in the resultant DE images.

Pre-filtering and Location Estimation of a Loose Part

  • Kim, Jung-Soo;Kim, Tae-Wan;Joon Lyou
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.522-522
    • /
    • 2000
  • In this paper, two pre-filtering techniques are presented for accurately estimating the impact location of a loose part. The reason why a pre-filterng technique Is necessary in a Loose Part Monitoring System is that the effects of background noise on the signal to noise ratio (SNR) can be reduced considerably resulting in improved estimation accuracy. The first method is to take d moving average operation in the time domain. The second one is to adopt band-pass filters designed in the frequency domain such as a Butterworth filter, Chebyshev filter I & II and an Elliptic Filter. To show the effectiveness, the impact test data (signals) from the YGN3 power plant are first preprocessed and then used to estimate the loose pan impact position. Resultantly. we observed that SNR is much improved and the average estimation error is below 7.5%.

  • PDF

Sound Source Localization Technique at a Long Distance for Intelligent Service Robot (지능형 서비스 로봇을 위한 원거리 음원 추적 기술)

  • Lee Ji-Yeoun;Hahn Min-Soo
    • MALSORI
    • /
    • no.57
    • /
    • pp.85-97
    • /
    • 2006
  • This paper suggests an algorithm that can estimate the direction of the sound source in real time. The algorithm uses the time difference and sound intensity information among the recorded sound source by four microphones. Also, to deal with noise of robot itself, the Kalman filter is implemented. The proposed method can take shorter execution time than that of an existing algorithm to fit the real-time service robot. Also, using the Kalman filter, signal ratio relative to background noise, SNR, is approximately improved to 8 dB. And the estimation result of azimuth shows relatively small error within the range of ${\pm}7$ degree.

  • PDF

Fundamental Background for 3T MRI/MRS

  • Choe, Bo-Young
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.47-49
    • /
    • 2002
  • At present, the trend of magnetic field strength in MRI system is dramatically changing. In early 70, the only low field (<0.5T) was developed. It was technically difficult to develop the high field system. At that time, people believed that the fine MR imaging could not be obtained in the high field MR system due to the magnetic susceptibility effect. However, 1.5T system was evolved at the end of 80, and used for clinical usage. Thus, it was proved that the signal to noise ratio (SNR) could be greatly contribute to enhance the image quality. And, the results of functional MRI and MR spectroscopy could be improved in the higher field MR system. So, 8T system was eventually developed in Ohio State University Hospital at the end of 90. Therefore, there is no doubt that the system with the ultra high magnetic field strength will be developed near future in 21 century.

  • PDF

Evaluation of Roadmap Image Quality by Parameter Change in Angiography (혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가)

  • Kong, Chang gi;Song, Jong Nam;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • The purpose of this study is to identify factors affecting picture quality in Roadmap images, which were studied by varying the dilution rate, collimation field and flow rate of contrast medium. For a quantitative evaluation of the quality of the picture, a 3mm vessel model Water Phantom was self-produced using acrylic, a roadmap image was acquired with a self-produced vascular model Water Phantom, and the SNR(Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were analyzed. CM:N/S In the study on the change of dilution rate, CM:N/S dilution rate changed to (100%~10%:100%), and the measurement of the roadmap image taken using the vascular model Water Phantom showed that the measurement value of SNR gradually decreased as the N/S dilution rate was increased, and the measurement of CNR was gradually reduced. It was confirmed that the higher the dilution rate of CM:N/S, the lower the SNR and CNR, and also significant image can be obtained at the dilution rate of CM:N/S (100%~70:30%). The study showed the value of SNR and CNR in Roadmap image was increased as the Collimation Field was narrowed to the center of the vascular phantom; the Collimation Field was narrowed to the center of the vessel model by 2cm intervals to 0cm through 12cm. To verify the relationship with Roadmap image and Flow Rate, volume of the autoinjector was kept constant at 15 and the flow rate was gradually increased 1, 2, 3, 4, 5, 6, 7, 8, 9, 10. The value of SNR and CNR of images taken by using water Phantom gradually decreased as the Flow Rate increased, but at Flow Rate 9 and 10, the SNR and CNR value was increase. It was not possible to confirm the relationship with SNR and CNR by ROI mean value and Background mean value. It is considered that further study is needed to evaluate the correlation about Roadmap image and Flow Rate. In conclusion, as the dilution rate of N/S in contrast medium was increased, the value of SNR and CNR was decreased. The narrower the Collimation Field, the higher image quality by increasing value of SNR and CNR. However, it is not confirmed the relationship Roadmap image and Flow Rate. It is considered that appropriate contrast medium concentration to minimize the effects of kidney and proper Collimation Field to improve contrast of image and reduce exposure X-ray during procedure is needed.

Canonical Correlation of 3D Visual Fatigue between Subjective and Physiological Measures

  • Won, Myeung Ju;Park, Sang In;Whang, Mincheol
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.6
    • /
    • pp.785-791
    • /
    • 2012
  • Objective: The aim of this study was to investigate the correlation between 3D visual fatigue and physiological measures by canonical correlation analysis enabling to categorical correlation. Background: Few studies have been conducted to investigate the physiological mechanism underlying the visual fatigue caused by processing 3D information which may make the cognitive mechanism overloaded. However, even the previous studies lack validation in terms of the correlation between physiological variables and the visual fatigue. Method: 9 Female and 6 male subjects with a mean age of $22.53{\pm}2.55$ voluntarily participated in this experiment. All participants were asked to report how they felt about their health sate at after viewing 3D. In addition, Low & Hybrid measurement test(Event Related Potential, Steady-state Visual Evoked Potential) and for evaluating cognitive fatigue before and after viewing 3D were performed. The physiological signal were measured with subjective fatigue evaluation before and after in watching the 3D content. For this study suggesting categorical correlation, all measures were categorized into three sets such as included Visual Fatigue set(response time, subjective evaluation), Autonomic Nervous System set(PPG frequency, PPG amplitude, HF/LF ratio), Central Nervous System set(ERP amplitude P4, O1, O2, ERP latency P4, O1, O2, SSVEP S/N ratio P4, O1, O2). Then the correlation of three variables sets, canonical correlation analysis was conducted. Results: The results showed a significant correlation between visual fatigue and physiological measures. However, different variables of visual fatigue were highly correlated to respective HF/LF ratio and to ERP latency(O2). Conclusion: Response time was highly correlated to ERP latency(O2) while the subjective evaluation was to HF/LF ratio. Application: This study may provide the most significant variables for the quantitative evaluation of visual fatigue using HF/LF ratio and ERP latency based human performance and subjective fatigue.

Simple Image-Separation Method for Measuring Two-Phase Flow of Freely Rising Single Bubble (상승하는 단일 버블 이상유동의 PIV 계측을 위한 영상분리기법)

  • Park Sang-min;Jin Song-wan;Kim Won-tae;Sung Jae-yong;Yoo Jung-Yul
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.7-10
    • /
    • 2002
  • A novel two-phase PIV algorithm using a single camera has been proposed, which introduces a method of image-separation into respective phase images, and is applied to freely rising single bubble. Gas bubble, tracer particle and background each have different gray intensity ranges on the same image frame when reflection and dispersion in the phase interface are intrinsically eliminated by optical filters and fluorescent material. Further, the signals of the two phases do not interfere with each other. Gas phase velocities are obtained from the separated bubble image by applying the two-frame PTV. On the other hand, liquid phase velocities are obtained from the tracer particle image by applying the cross-correlation algorithm. Moreover, in order to increase the SNR (signal-to-noise ratio) of the cross-correlation of tracer particle image, image enhancement is employed.

  • PDF