• 제목/요약/키워드: Signal stability

검색결과 899건 처리시간 0.029초

반도체 변압기용 단상 계통 연계형 인버터의 소신호 모델링과 제어기 설계 (Small-Signal Modeling and Controller Design of Grid-Connected Inverter for Solid State Transformer)

  • 김보경;이준영;;정지훈
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.40-47
    • /
    • 2017
  • In this paper, a small signal model for grid-connected inverter with unipolar pulse width modulation method is presented. Small-signal analysis allows to predict the stability and dynamics of the inverter. To regulate output voltage and to achieve power factor correction, inverter has two control loops. Loop gains are useful to identify the stability for multi-loop controlled system. Based on small-signal model, controllers are designed to improve audio susceptibility and output impedance characteristics. Proposed small-signal model and controllers are verified by PSIM simulation and experiments.

인공위성 시스템을 위한 태양전지 전력조절기의 저항제어 (Resistive Current Mode Control for the Solar Array Regulator of SPACE Power System)

  • 배현수;양정환;이재호;조보형
    • 전력전자학회논문지
    • /
    • 제11권6호
    • /
    • pp.535-542
    • /
    • 2006
  • 저궤도 인공위성 전력계 시스템의 설계 및 해석을 위한 태양전지 전력조절기의 대신호 안정도해석을 수행한다. 태양전지 전력조절기에서 제어가능한 모든 방법에 따른 태양전지에서 바라본 태양전지 전력조절기의 부하특성을 분류하고, 상태공간해석을 이용하여 태양전지 시스템의 대신호적 안정도를 해석한다. 또한, 본 논문에서는 태양전지 전력조절기의 부하특성을 정전력부하에서 정저항부하로 변환하여 대신호적인 안정도를 확보하는 비선형변환을 제안한다. 제안된 변환기법을 통해 최대전력점 추적제어나 배터리 충전제어 및 전류분배제어가 가능한 병렬 모듈 태양전지 레귤레이터에 적합한 단일 전류 제어기를 구성한다. 제안된 대신호 해석과 저항제어를 검증하기위해, 200W급 태양전지와 100W급 태양전지 전력조절기 두 모듈을 병렬로 구성하여 실험하였다.

대규모 전력계통의 미소신호 안정도 해석을 위한 Hessenberg Process의 수렴특성 가속화 방법 (A Method to Accelerate Convergence of Hessenberg process for Small Signal Stability Analysis of Large Scale Power Systems)

  • 송성근;남해곤;심관식;문채주;김용구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.871-874
    • /
    • 1998
  • It is most important in small signal stability analysis of large scale power systems to compute only the dominant eigenvalues selectively with numerical stability and efficiency. Hessenberg process is numerically very stable and identifies the largest eigenvalues in magnitude. Hence, transformed system matrix must be used with the process. Inverse transformation with complex shift provides high selectivity centered on the shift, but does not possess the desired property of computing the dominant mode first. Thus, advantage of high selectivity of the transformation can be fully utilized only when the complex shift is given close to the dominant eigenvalues. In this paper, complex shift is determined by Fourier transforming the results of dynamic simulation with PTI's PSS/E transient simulation program. The convergence in Hessenberg process is accelerated using the iterative scheme. Overall, a numerically stable and very efficient small signal stability program is obtained. The stability and efficiency of the program has been validated against New England 10-machines 39-bus system and KEPCO system.

  • PDF

시간영역에서 파라미터 추정과 전력계통의 저주파진동 해석 (A Parameter Estimation of Time Signal and Analysis of Low Frequency Oscillation in Power Systems)

  • 심관식;남해곤;김용구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권3호
    • /
    • pp.122-132
    • /
    • 2005
  • This paper presents a novel approach based on Prony method to analysis of small signal stability in power system. Prony method is a valuable tool in identifying transfer function and estimating the modal parameter of power system oscillation from measured or computed discrete time signal. This paper define the relative residue of time signal and propose the condition to select low frequency oscillation in each generator. This paper describes the application results of proposed algorithm with respect to KEPCO systems. Simulation results show that the proposed algorithm can be used as another tools of power systems analysis.

반복 학습법에 의한 비선형 계의 입력신호 재현 (Input signal reconstruction for nonlinear systems using iterative learning procedures)

  • Seo, Jong-Soo;S. J. Elliott
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.855-861
    • /
    • 2002
  • This paper demonstrates the reconstruction of input signals from only the measured signal for the simulation and endurance test of automobiles. The aim of this research is concerned with input signal reconstruction using various iterative teaming algorithm under the condition of system characteristics. From a linear to nonlinear systems which provides the output signals are estimated in this algorithm which is based on the frequency domain. Our concerns are that the algorithm can assure an acceptable stability and convergence compared to the ordinary iterative learning algorithm. As a practical application, a f car model with nonlinear damper system is used to verify the restoration of input signal especially with a modified iterative loaming algorithm.

  • PDF

음압신호와 안정도제어법을 이용한 선삭작업에서의 채터 감시 및 제어 (Monitoring and Control of Turing Chatter using Sound Pressure and Stability Control Methodology)

  • 이성일
    • 한국생산제조학회지
    • /
    • 제6권4호
    • /
    • pp.101-107
    • /
    • 1997
  • In order to detect and suppress chatter in turning process, a stability control methodology was studied through manipulation of spindle speeds regarding to chatter frequencies, The chatter frequency was identified by monitoring and signal processing of sound pressure during turing on a lathe. The stability control methodology can select stable spindle speeds without knowing a prior knowledge of machine compliances and cutting dynamics. Reliability of the developed stability control methodology was verified through turing experiments on an engine lathe. Experimental results show that a microphone is an excellent sensor for chatter detection and control .

  • PDF

대규모 전력계통의 과도안정도 상정사고 선택에 고유치감도 응용 (Applications of Eigen-Sensitivity for Contingency Screening of Transient Stability in Large Scale Power Systems)

  • 심관식;남해곤;김용구;송성근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.193-196
    • /
    • 1999
  • This paper presents a new systematic contingency selection and screening method for transient stability. The variation of modal synchronizing torque coefficient(MSTC) is computed using eigen-sensitivity analysis of the electromechanical oscillation modes in small signal stability model and contingencies are ranked in decreasing order of the sensitivities of the MSTC(SMSTC). The relevant clusters are identified using the eigenvector or participating factor. The proposed algorithm is tested on the KEPCO system. Ranking obtained by the SMSTC is consistent with the time simulation results by PSS/E.

  • PDF

한전 전력계통의 저주파 진동현상 요인분석;양수발전기 기동시 (Analysis of the Factors Affecting Low-Frequency Oscillations in KEPCO Power System` With Pumped-Storage Plant)

  • Kil Yeong Song;Sae Hyuk Kwon;Kyu Min Ro;Seok Ha Song
    • 대한전기학회논문지
    • /
    • 제41권8호
    • /
    • pp.841-849
    • /
    • 1992
  • In power system operation, the stability of synchronous machine has been recognized one of the most important things. AESOPS program developed by EPRI in U.S.A. is a frequency domain analysis program in power system stability and it computes the electro-mechanical oscillation mode. This paper presents how to analyze the power system small signal stability problem efficiently by uusing the AESOPS program and analyze the various factors affecting the damping characteristics of these oscillations in KEPCO power system of 1986 with pumped-storage plant. To reduce the computing time and efforts, selecting the poorly-damped oscillation mode and clustering technique have been used. The characteristics of load, the amount of power flow on the transmission line and the gain of exciter have a significant effects on the damping of the system while the governing system has only a minor one. With the Power System Stabilizers, the stability of the power system has been improved.

  • PDF

Scaling Factor Design Based Variable Step Size Incremental Resistance Maximum Power Point Tracking for PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.164-171
    • /
    • 2012
  • Variable step size maximum power point trackers (MPPTs) are widely used in photovoltaic (PV) systems to extract the peak array power which depends on solar irradiation and array temperature. One essential factor which judges system dynamics and steady state performances is the scaling factor (N), which is used to update the controlling equation in the tracking algorithm to determine a new duty cycle. This paper proposes a novel stability study of variable step size incremental resistance maximum power point tracking (INR MPPT). The main contribution of this analysis appears when developing the overall small signal model of the PV system. Therefore, by using linear control theory, the boundary value of the scaling factor can be determined. The theoretical analysis and the design principle of the proposed stability analysis have been validated using MATLAB simulations, and experimentally using a fixed point digital signal processor (TMS320F2808).

GTO 제어 STATCOM을 포함하는 이산 전력시스템의 RCF 해석법에 의한 진동모드 해석 (Analysis of Oscillation Modes in Discrete Power Systems Including GTO Controlled STATCOM by the RCF Method)

  • 김덕영
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.829-833
    • /
    • 2007
  • In this paper, the RCF method is applied to analyze small signal stability of power systems including GTO controlled parallel FACTS equipments such as STATCOM. To apply the RCF method in power system small signal stability problems, state transition equations of generator, controllers and STATCOM are presented. In eigenvalue analysis of power systems, STATCOM is modelled as the equivalents voltage source model and the PWM switching circuit model. As a result of simulation, the RCF method is very powerful to calculate the oscillation modes exactly after the switching operations, and useful to analyze the small signal stability of power systems with periodically operated switching devices such as STATCOM.