• 제목/요약/키워드: Signal stability

검색결과 901건 처리시간 0.024초

디지털 PID 제어기의 제한 요소 영향 분석(II):유한 단어 길이 문 (Analysis of Limitation Factor Effects on Digital PID Controller(II) : Finite Wordlength Issue)

  • 홍석민;김인중;이상정
    • 대한전기학회논문지
    • /
    • 제43권2호
    • /
    • pp.318-329
    • /
    • 1994
  • This paper deals with the finite wordlength effect on the performance of digital PID controllers. The finite wordlength, one of the major limitation factors in digital controllers, results on two kinds of quantization error : the signal quantization error and the coefficient quantization error. This paper derives the variance of the plant output due to the signal quantization error. Using stability margins as performance criterion, the statistical wordlength concept is adopted for coefficient wordlength selection. Finally, the experimental results exhibit satisfactory performance of the digital PID controller with statistical coefficient wordlength.

PID 서보제어기를 이용한 곡면유리 자동성형 시스템 개발 (Development of Curved-Glass Automatic Shaping System using PID Servo-Drivers)

  • 유병국;양근호
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2003년도 하계학술대회 논문집
    • /
    • pp.161-164
    • /
    • 2003
  • This research presents the parallel control scheme of PID servo-driver for shaping of the curved glass. The designed system consists of a PC, main controller and 11 servo-drivers. Each elements are connected by using RS-232C and 8-bit bus communication. In order to guarantee the stability and the control performance, we use the LM629, a precision PID motion controller, and LMD18200, a H-bridge on the servo-drivers. PC calculates position values of 11 DC motors by using the pre-determined curvature value and offers the user interface environment operator.

  • PDF

계통의 종합적 미소신호 안정도 해석에 관한 연구 (Study of a unified framework for small signal stability of power systems)

  • 김상암;이병준;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.201-203
    • /
    • 1998
  • This paper presents the framework for analysis of small-signal stabili1ty. In this framework the equilibrium points of system DAE model are traced using continuation method and instability points are determined on the solution path. Especially Implicit shift QR-modified ARnoldi method is utilized to calculated the rightmost eigenvalues. ISPS measure is utilized to determine critical parameters.

  • PDF

PHYTOCHROME-SPECIFIC TYPE 5 PHOSPHATASE CONTROLS LIGHT SIGNAL FLUX BY ENHANCING PHYTOCHROME STABILITY AND AFFINITY FOR A SIGNAL TRANSDUCER.

  • Ryu, Jong-Sang;Kim, Jeong-Il;Kunkel, Tim;Kim, Byung-Chul;Cho, Dae-Shik;Hong, Sung-Hyun;Kim, Seong-Hee;Fernndez, Aurora Pias;Kim, Yu-Mi;Alonso, Jose M.;Ecker, Joseph R.;Nagy, Ferenc;Lim, Pyung-Ok;Song, Pill-Soon;Schfer, Eberhard;Nam, Hong-Gil
    • 한국광과학회:학술대회논문집
    • /
    • 한국광과학회 2005년도 제12회 학술대회 논문초록
    • /
    • pp.21-23
    • /
    • 2005
  • PDF

SS-OCT용 고 주파수분해능 저비용 정현파 발생기 (Low Cost Signal Generator with Frequency High-Resolution for SS-OCT)

  • 이주찬;엄진섭
    • 센서학회지
    • /
    • 제22권1호
    • /
    • pp.84-88
    • /
    • 2013
  • In this paper, the low price signal generator with capability of frequency high-resolution and variable sync pulse has implemented. It fulfils well the requirements for SS-OCT of the frequency resolution less than 1Hz, frequency stability of ${\leq}{\pm}0.5Hz$/10 min and variable sync pulse output timing. Through its performance test applied to wavelength swept laser, 120 nm sweeping range and 10 mW average optical power were obtained. This shows that the realized sine-wave generator can replace the commercial high cost and high performance signal generators employed by current SS-OCT systems.

포구속도측정레이더의 불확도에 관한 연구 (A Study on the Uncertainty of MVRS)

  • 박용석;최주호
    • 한국군사과학기술학회지
    • /
    • 제10권1호
    • /
    • pp.94-100
    • /
    • 2007
  • MVRS's measuring principles are based on the Doppler principle. It measures the velocities near the muzzle using the doppler signal output from the antenna and then predicts the velocity of the bullet leaving the muzzle by performing the regression analysis on previous measured velocities. There are a number of error sources when calculating the muzzle velocity. Antenna has long term frequency stability error and the doppler signal from the antenna has noise. These two error sources influence the accuracy of estimated velocities from the doppler signal. Estimated velocity errors result in the random error of data statistics. And when performing a regression analysis these random error components are transferred to the fitting error component. This study also analyzed the error components according to the hardware limitations of MVRS-700 and the signal processing method, and presented the calculated uncertainty of muzzle velocity.

방사선 조사된 조개류의 확인을 위한 ESR Spectroscopy의 이용 (ESR Spectroscopy for Detecting Gamma-Irradiated Shellfishes)

  • 남혜선;양재승
    • 한국식품영양과학회지
    • /
    • 제30권1호
    • /
    • pp.43-47
    • /
    • 2001
  • Electron spin resonance (ESR) spectroscopy was used to investigate the effect of irradiation dose on the ESR signal intensity and to identify the stability of radicals after 9 weeks of storage in order to detect irradiated shellfishes. The irradiated shellfishes (short-necked clam, purplish washington clam, freshwater clam, jackknifed clam, scallop and hard-shell mussel) presented an asymmetric absorption in shape at $g_{1}$=2.002~2.003 and $g_{2}$=1.998. The strength of the ESR signal increased linearly with the applied doses (1~7 kGy). A highly positive correlation coefficients ($R^{2}$=0.9136~0.9896) were obtained between the irradiation dose and corresponding ESR signal intensity. The intensity of the signals after irradiation was stable even after 9 weeks of storage at 5$\pm$1$^{\circ}C$.

  • PDF

GMAW에서 아크 빛을 이용한 실시간 용접품질 모니터링에 관한 연구 (A Study on On-Line Quality Monitoring Using Arc Light in Gas Metal Arc Welding)

  • 조택동;양상민
    • Journal of Welding and Joining
    • /
    • 제18권4호
    • /
    • pp.82-86
    • /
    • 2000
  • Gas metal arc welding(GMAW) is regarded as one of the best candidate for welding automation in industrial joining application. It is important to monitor the weld quality for the high performance weld automation. In GMAW, weld quality is closely related to arc stability especially. In this paper, arc light signal is measured and spectrum analyzed to the detect the variation of the weld quality. The FFT of the signal showed that the amplitude variance of FFT power spectrum was very large in poor weld process such as the decrease of weld bead width and height. The results show that it is possible to detect the weld defect position in weld process.

  • PDF

레이더용 다채널 수신기 설계 및 제작 (The Design and Fabrication of Multi-Channel Receiver for Radar System)

  • 김완식;이한영
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1671-1675
    • /
    • 2012
  • In this paper, we fabricate multi-channel receiver for radar system. This receiver at X-band can be received 8 signal of an identical characteristic, dynamic range has more than 80[dB]. To process direct received signals, this system has the built-in two digital de-modulators which offer the minimum loss on the receiving signal path and has high stability by adding Built-In Test. The gain, noise figure, difference of amplitude and phase on the signal path is respectively $14{\pm}2$[dB], 19[dB], ${\pm}2$[dB], $10^{\circ}$ and below.

ESR Spectroscopy에 의한 감마선 조사된 향신료의 확인 (Detection of Gamma-Irradiated Spices by ESR Spectroscopy)

  • 양재승;남혜선
    • 한국식품영양과학회지
    • /
    • 제30권2호
    • /
    • pp.239-242
    • /
    • 2001
  • Electron spin resonance(ESR) spectroscopy was used to investigate the effect of irradiation dose on the ESR signal intensity of irradiated spices and to identify the stability of radicals after storage. Red, white and black peppers, and garlic powders were irradiated with doses of 0, 1, 5, 10, 20 and 30 kGy at room temperature using a Co-60 irradiator. Triplet ESR signals were observed in irradiated pepper powders, while singlet ESR signals were observed in irradiated garlic powders. Those characteristic signals were not detected in non-irradiated samples. The strength of ESR signals linearly increased with the applied doses(1~3 kGy). Highly positive correlation coefficients ($R^2$=0.9757~0.9933) were obtained between the irradiation doses and the corresponding ESR signal intensities. The signal intensities of irradiated samples were stable even after 97 days of storage at room temperature.

  • PDF