• 제목/요약/키워드: Signal intensity(SI)

검색결과 69건 처리시간 0.02초

병원 안전 심볼의 형태와 기억과의 관계 (Relationship between Hospital Safety Symbol Shapes and Memory)

  • 배석환;박명철;유재상;김용권;류철호;오동현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권2호
    • /
    • pp.115-122
    • /
    • 2023
  • The purpose of this study was to examine the association between the shapes and colors of emergency exit symbols, magnetic field warning symbols, and radiation zone symbols used in hospitals for staff and patient safety and their effects on cognitive memory. The hippocampal region's signal intensity(SI) was analyzed using fMRI. The Symbol 2 (1.75±0.54) with a green background had the highest signal intensity (SI) for emergency exits, according to the findings. The black symbol 2 (1.60±0.51) with a yellow background had the highest signal intensity (SI) for the magnetic field warning symbol, followed by the black symbol 1 (1.59±0.65) with an orange background. The black symbol 2 (1.59±0.59) with a yellow background and the black symbol 3 (1.58±0.52) with an orange background had the low signal intensity with slight differences as for the radiation zone symbols. In conclusion, it was determined that the signal intensity of the black symbol with a yellow background was the highest in the magnetic field area and radiation area. This implies that symbols with a high signal intensity (SI) must be utilized intensively. To ensure that the correct meaning of the symbols is communicated in the future, they must also be utilized regularly and continually in disaster safety education.

Magnetic resonance images of ameloblastoma

  • Kim Jae-Duk;Kim Jin-Soo
    • Imaging Science in Dentistry
    • /
    • 제35권4호
    • /
    • pp.207-213
    • /
    • 2005
  • Purpose: To classify and describe the characteristic features of MRI of some ameloblastoma variants. Materials and Methods: The MR images, CT images, and panoramic radiographs in 5 cases were retrospectively examined as follows. First, the contents of ameloblastomas were devided into two portions of either solid or cystic components on the basis of MR signal intensities. The signal intensity within the solid or cystic portions was classified as homogeneous or heterogeneous. Next, the characteristic internal feature of the lesion on T1W1 or T2WI was described. The signal intensities were classified into low, intermediate, slightly high, high, and strong high signal intensity. Results: Unicystic lesion showed homogeneous high signal intensity (SI) on T2W2 and the rim enhancement of the surrounding area including the mural nodule and the thick wall except the central portion on Gd- T1W1. Solid type revealed heterogeneous and high SI area with strong high SI area on T2W2. On Gd- T1W1, the area corresponding to the low signal spot on T1W1 and the strong high signal spot on T2W1 showed low SI. Hybrid type showed slightly enhanced capsular structures and low SI for the round bony septa and the areas connecting the mixed and cystic lesions on T2Wl and Gd-T1W1. Conclusion: MRI could easily assess the relationship between the mixed and cystic findings in ameloblastoma.

  • PDF

4-Valve SI 엔진의 Knock 특성 및 Knock 발생부위 측정 (Knock Characteristics and Measurement of Knock Location in a 4-Valve SI Engine)

  • 이경환;이시훈
    • 한국자동차공학회논문집
    • /
    • 제6권5호
    • /
    • pp.153-161
    • /
    • 1998
  • The knock in a spark ignition engine has been investigated to avoid the damage to the engine and unpleasant feeling caused by the pressure waves propagating across the combustion chamber. Knock intensity and knock onset angle were used as physical parameters to quantify the knock characteristics. The knock intensity is defined as a peak to peak value of the bank pass filtered combustion pressure signal and the knock onset angle is determined as the crank angle at which this signal exceeded the threshold level on each cycle. The cyclic variation of knock in four valve single cylinder engine was investigated with these two parameters. The location of autoignition was also examined by ion probes in the cylinder head gasket and squish region in the combustion chamber. For this measurement, a single cylinder engine was modified to accept the pressure transducer, 18 ion probes in the squish region and 8 ion probes in the specially designed PCB (Printed \ulcornerCircuit Board) cylinder head gasket.

  • PDF

적외선 배경신호 처리를 통한 OES 기반 PECVD공정 모니터링 정확도 개선 (OES based PECVD Process Monitoring Accuracy Improvement by IR Background Signal Subtraction from Emission Signal)

  • 이진영;서석준;김대웅;허민;이재옥;강우석
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.5-9
    • /
    • 2019
  • Optical emission spectroscopy is used to identify chemical species and monitor the changes of process results during the plasma process. However, plasma process monitoring or fault detection by using emission signal variation monitoring is vulnerable to background signal fluctuations. IR heaters are used in semiconductor manufacturing chambers where high temperature uniformity and fast response are required. During the process, the IR lamp output fluctuates to maintain a stable process temperature. This IR signal fluctuation reacts as a background signal fluctuation to the spectrometer. In this research, we evaluate the effect of infrared background signal fluctuation on plasma process monitoring and improve the plasma process monitoring accuracy by using simple infrared background signal subtraction method. The effect of infrared background signal fluctuation on plasma process monitoring was evaluated on $SiO_2$ PECVD process. Comparing the $SiO_2$ film thickness and the measured emission line intensity from the by-product molecules, the effect of infrared background signal on plasma process monitoring and the necessity of background signal subtraction method were confirmed.

Super-RENS 디스크의 노이즈 특성 향상 (Improvement of Noise Characteristics in Super-RENS Disc)

  • 김주호;김현기;황인오;박인식;배재철
    • 정보저장시스템학회논문집
    • /
    • 제1권1호
    • /
    • pp.48-52
    • /
    • 2005
  • The research topic of super-RENS technology is shifting from the signal intensity (CNR; Carrier to Noise Ratio) to the signal uniformity (Jitter or bER). To achieve an uniform signal characteristics, it is important to reduce signal fluctuation in a super-RENS disc. In this study, we investigated the relation between signal fluctuation and low frequency noise (LFN), and analyzed LFN increase in recording and readout processes. It was found that signal fluctuation had a close relationship with the LFN. Also, it was found that the recorded mark shape such a bubble type and high readout power increased the LFN in recording and readout process of a super-RENS disc. So, using non-bubble type recording material and low super-resolution readout material, we markedly improved the LFN in a super-RENS disc.

  • PDF

APPLICATION OF SOUND INTENSITY METHOD TO NOISE CONTROL ENGINEERING AND BUILDING ACOUSTICS

  • Tachibana, Hideki
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1995년도 추계학술대회논문집; 한국종합전시장, 24 Nov. 1995
    • /
    • pp.7-15
    • /
    • 1995
  • Sound pressure and particle velocity are the most essential quantities prescribing a sound field; they correspond to voltage and electric current respectively, in electric system. As electric power is the product of voltage and electric current, sound intensity is the product of sound pressure and particle velocity and it means the acoustic power passing through a unit area in a sound field. Although the definition of sound intensity is very simple as mentioned above, the method of measuring this quantity has not been realized for a long time, because it has been very difficult to measure the particle velocity simultaneously with the sound pressure. Owing to the recent development of such technologies as transducer production and digital signal processing, it has finally been realized. According to the sound intensity(SI) method, the sound power flow in an arbitrary sound field can be directly measured as a vector quantify. In this paper, the principle of the SI method is briefly explained at first and some examples of its application made in the author's laboratory are introduced.

  • PDF

Surface Photovoltage in Electron Beam Irradiation Semi-insulating GaAs

  • Yu, Jae-In;Lim, Jin-Hwan;Yu, Jae-Yong;Kim, Ki-Hong
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.543-545
    • /
    • 2006
  • Surface photovoltage (SPV) measurements were performed to investigate the optic-electrical properties in the electron beam irradiation semi-insulating GaAs (e-beam irradiation SI-GaAs) and semi-insulating GaAs (SI-GaAs). The signal intensity showed stronge. dependency on the frequency in the SI-GaAs than it did in the e-beam irradiation SI-GaAs. This result indicates that the number of the generated photo-carriers depends on the surface state. Also, the B region of the e-beam irradiation SI-GaAs found a weak signal. This result was explained by the surface and internal damage with e-beam irradiation.

Study of Apparent Diffusion Coefficient Changes According to Spinal Disease in MR Diffusion-weighted Image

  • Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.146-149
    • /
    • 2017
  • In this study, we compared the standardized value of each signal intensity, the apparent diffusion coefficient (ADC) that digitizes the diffusion of water molecules, and the signal to noise ratio (SNR) using b value 0 400, 1400 ($s/mm^2$). From March 2013 to December 2013, patients with suspicion of simple compound fracture and metastatic spine cancer were included in the MR readout. We used a 1.5 Tesla Achieva MRI system and a Syn-Spine Coil. Sequence is a DWI SE-EPI sagittal (diffusion weighted imaging spin echo-echo planar imaging sagittal) image with b-factor ($s/mm^2$) 0, 400, 1400 were used. Data analysis showed ROI (Region of Interest) in diseased area with high SI (signal intensity) in diffusion-weighted image b value 0 ($s/mm^2$) Using the MRIcro program, each SI was calculated with images of b-value 0, 400, and 1400 ($s/mm^2$), ADC map was obtained using Metlab Software with each image of b-value, The ADC is obtained by applying the ROI to the same position. The standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of simple compression fractures were $0.47{\pm}0.04$ and $0.23{\pm}0.03$ and the standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of the metastatic spine were $0.57{\pm}0.07$ and $0.32{\pm}0.08$ And the standardized values of the two diseases were statistically significant (p < 0.05). The ADC ($mm^2/s$) for b value 400 ($s/mm^2$) and 1400 ($s/mm^2$) of the simple compression fracture disease site were $1.70{\pm}0.16$ and $0.93{\pm}0.28$ and $1.24{\pm}0.21$ and $0.80{\pm}0.15$ for the metastatic spine. The ADC ($mm^2/s$) for b value 400($s/mm^2$) was statistically significant (p < 0.05) but the ADC ($mm^2/s$) for b value 1400 (p > 0.05). In conclusion, multi - b value recognition of signal changes in diffusion - weighted imaging is very important for the diagnosis of various spinal diseases.

Does Intramedullary Signal Intensity on MRI Affect the Surgical Outcomes of Patients with Ossification of Posterior Longitudinal Ligament?

  • Choi, Jae Hyuk;Shin, Jun Jae;Kim, Tae Hong;Shin, Hyung Shik;Hwang, Yong Soon;Park, Sang Keun
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권2호
    • /
    • pp.121-129
    • /
    • 2014
  • Objectives : Patients with cervical ossification of posterior longitudinal ligament (OPLL) are susceptible to cord injury, which often develops into myelopathic symptoms. However, little is known regarding the prognostic factors that are involved in minor trauma. We evaluated the relationship between minor trauma and neurological outcome of OPLL and investigated the prognostic factors with a focus on compressive factors and intramedullary signal intensity (SI). Methods : A total of 74 patients with cervical myelopathy caused by OPLL at more than three-levels were treated with posterior decompression surgeries. We surveyed the space available for spinal cord (SAC), the severity of SI change on T2-weighted image, and diabetes mellitus (DM). The neurological outcome using Japanese Orthopedic Association (JOA) scale was assessed at admission and at 12-month follow-up. Results : Among the variables tested, preoperative JOA score, severity of intramedullary SI, SAC, and DM were significantly related to neurological outcome. The mean preoperative JOA were $11.3{\pm}1.9$ for the 41 patients who did not have histories of trauma and $8.0{\pm}3.1$ for the 33 patients who had suffered minor traumas (p<0.05). However, there were no significant differences in the recovery ratios between those two groups. Conclusions : Initial neurological status and high intramedullary SI in the preoperative phase were related to poorer postoperative outcomes. Moreover, the patients with no histories of DM and larger SACs exhibited better improvement than did the patients with DM and smaller SACs. Although the initial JOA scores were worse for the minor trauma patients than did those who had no trauma prior to surgery, minor trauma exerted no direct effects on the surgical outcomes.

MRI sequence에 따른 GBCA 몰농도별 반응에 대한 정량적 분석 (Quantitative Analysis of GBCA Reaction by Mol Concentration Change on MRI Sequence)

  • 정현근;정현도;김호철
    • 전자공학회논문지
    • /
    • 제52권2호
    • /
    • pp.182-192
    • /
    • 2015
  • 본 논문에서는 GBCA(Gadolinium Based Contrast Agent)를 이용한 MRI 검사 시 다양한 MR 시퀀스에 따른 GBCA 몰농도별 조영증강 변화를 알아보기 위해 자체 제작한 MR 팬텀을 사용하여 정량적으로 평가 분석하고자 하였다. MR 팬텀을 제작하기 위해 28개의 용기에 500 mmol Gadoteridol을 saline과 혼합하여 각각 500 부터 0 mmol 까지 몰농도를 서로 다르게 하였다. 제작된 MR phantom을 1.5T MRI 장비에서 물리학적 기전이 서로 다른 T1 SE, T2 FLAIR, T1 FLAIR, 3D FLASH, T1 3D SPACE, 3D SPCIR 시퀀스로 스캔하여 신호강도 변화를 측정 한 후 비교 분석 하였다. T1 Spin echo는 Total SI(Signal Intensity)가 15608.7, Max peak는 1 mmol에서 1352.6, T2 FLAIR는 Total SI가 9106.4, Max peak는 0.4 mmol에서 1721.6, T1 FLAIR에서는 Total SI가 20972.5, Max peak는 1 mmol에서 1604.9, 3D FLASH는 Total SI가 20924.0, Max peak는 40 mmol에서 1425.7, 3D SPACE 1mm는 Total SI가 6399.0, Max peak는 3 mmol에서 528.3, 3D SPACE 5mm는 Total SI가 6276.5, Max peak는 2 mmol에서 514.6, 3D SPCIR의 경우는 Total SI가 1778.8, Max peak는 0.4 mmol에서 383.8의 신호강도를 보였다. T1 SE를 포함한 대부분의 시퀀스에서 몰농도가 높았을 때 보다는 대체적으로 일정이상 희석이 이루어진 비교적 낮은 농도에서 높은 신호강도를 보였다. 또한 서로 다른 물리학적 기전의 다양한 MR시퀀스에서 GBCA의 조영증강 패턴 역시 모두 달랐다. 본 연구를 통해 얻어진 시퀀스에 따른 GBCA 농도별 반응에 대한 정량적 데이터를 통하여 실제 임상에서의 조영증강검사에 있어서 효율적인 MR검사 프로토콜에 활용할 수 있을 것으로 사료된다.