• 제목/요약/키워드: Signal amplification

검색결과 250건 처리시간 0.032초

Fundamental requirements for performing electroencephalography

  • Koo, Dae Lim;Kim, Won-Joo;Lee, Sang-Ahm;Kim, Jae Moon;Kim, Juhan;Park, Soochul;Korean Society of Clinical Neurophysiology Education Committee
    • Annals of Clinical Neurophysiology
    • /
    • 제19권2호
    • /
    • pp.113-117
    • /
    • 2017
  • The performance of electroencephalogram (EEG) recordings is affected by electrode type, electronic parameters such as filtering, amplification, signal conversion, data storage; and environmental conditions. However, no single method has been identified for optimal EEG recording quality in all situations. Therefore, we aimed to provide general principles for EEG electrode selection as well as electronic noise reduction, and to present comprehensive information regarding the acquisition of satisfactory EEG signals. The standards provided in this document may be regarded as Korean guidelines for the clinical recording of EEG data. The equipment, types and nomenclature of electrodes, and the details for EEG recording are discussed.

Analytical Techniques Using ICP-MS for Clinical and Biological Analysis

  • Ko, Jungaa;Lim, H. B.
    • Mass Spectrometry Letters
    • /
    • 제6권4호
    • /
    • pp.85-90
    • /
    • 2015
  • This article reviews recent analytical techniques using inductively coupled plasma-mass spectrometry (ICP-MS) immunoassay for clinical and bio analysis. We classified the techniques into two categories, direct and indirect analysis, which depend upon a guideline of whether tagging materials are used or not. Direct analysis is well known, and generally used in conjunction with various other techniques, such as laser ablation, chromatographic separations, etc. Recently, indirect analysis using tagging elements has intensively been discussed because of its importance in future applications to bio and clinical analysis, including environmental and food industries. The method has shown advantages of multiplex detection, excellent sensitivity, and short analysis time owing to signal amplification and magnetic separation. Now, it expands the application field from small biomolecules to large cells.

Radio-on-Fiber 액세스시스템 기술

  • 박종대;남상식;박권철
    • 전자공학회지
    • /
    • 제30권3호
    • /
    • pp.295-295
    • /
    • 2003
  • The advantages of using analogue optical networks for delivering radio signals from a central location to many remote antenna sites have been recognized. In a telecommnications context, radio signals may be for fixed radio access, cordless or mobile networks, but the same principles apply. By making use of the high bandwidth, low loss characteristics of optical fiber, all high frequency and signal processing functions can be performed centrally and signals can then be transported over the optical network directly at the carrier frequency. The remote sites then become very simple, requiring only optoelectronic conversion, filtering and linear amplification. This shifting of the complex functionality away from the remote site allow cheap, reliable, small and light-weight radio access points with low power consumption to be deployed. In this paper, we show that an electroabsorption modulation(EAM) may be used as a single component in such a radio access point, as a passive transceiver for small-sized cell(picocells).

Radio-on-Fiber 액세스시스템 기술

  • 박종대;남상식;박권철
    • 전자공학회지
    • /
    • 제30권3호
    • /
    • pp.81-85
    • /
    • 2003
  • The advantages of using analogue optical networks for delivering radio signals from a central location to many remote antenna sites have been recognized. In a telecommnications context, radio signals may be for fixed radio access, cordless or mobile networks, but the same principles apply. By making use of the high bandwidth, low loss characteristics of optical fiber, all high frequency and signal processing functions can be performed centrally and signals can then be transported over the optical network directly at the carrier frequency. The remote sites then become very simple, requiring only optoelectronic conversion, filtering and linear amplification. This shifting of the complex functionality away from the remote site allow cheap, reliable, small and light-weight radio access points with low power consumption to be deployed. In this paper, we show that an electroabsorption modulation(EAM) may be used as a single component in such a radio access point, as a passive transceiver for small-sized cell(picocells).

  • PDF

CDMA 통신용 IS-95A/B, IS-95C 서비스의 Cell 확대를 위한 광중계기 연결보조장치 (IS-95C coupler for Optical repeater for Cell extension of IS-95A/B & IS-95C service)

  • 정재성;김부곤;이용국
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2001년도 종합학술발표회 논문집 Vol.11 No.1
    • /
    • pp.39-43
    • /
    • 2001
  • A system, IS-95C coupler that combines the signals of IS-95A/B and IS-95C BTS and compensates the differences between the signals of two systems and connected to optical repeater If no IS-95C coupler exist, Optical repeater can't service of signal balanced. A system carries on combination, amplification, level modulation function of the TX signals(IS-95A/B & IS-95C) and division and level modulation function of the RX signals. Isolation satisfied above 100dB.

  • PDF

Innate immune response in insects: recognition of bacterial peptidoglycan and amplification of its recognition signal

  • Kim, Chan-Hee;Park, Ji-Won;Ha, Nam-Chul;Kang, Hee-Jung;Lee, Bok-Luel
    • BMB Reports
    • /
    • 제41권2호
    • /
    • pp.93-101
    • /
    • 2008
  • The major cell wall components of bacteria are lipopolysaccharide, peptidoglycan, and teichoic acid. These molecules are known to trigger strong innate immune responses in the host. The molecular mechanisms by which the host recognizes the peptidoglycan of Gram-positive bacteria and amplifies this peptidoglycan recognition signals to mount an immune response remain largely unclear. Recent, elegant genetic and biochemical studies are revealing details of the molecular recognition mechanism and the signalling pathways triggered by bacterial peptidoglycan. Here we review recent progress in elucidating the molecular details of peptidoglycan recognition and its signalling pathways in insects. We also attempt to evaluate the importance of this issue for understanding innate immunity.

FeCoGe/페놀 복합체의 정적 자기변형 측정 (Static measurement of magnetostriction of FeCoGe/phenol composites)

  • 박경일;나석민;신광호;임상호;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.577-580
    • /
    • 2003
  • The magnetostriction of FeCoGe/phenol composites, which is one of the magnetostrictive materials, measured at the external magnetic field. The measurement was carried out using the electrical-resistance strain gage, the wheaten's Bridge for eliminating the unnecessary voltage, and the lock-in-amp for signal amplification and noise filtering. When the external magnetic field was applied in the longitudinal the samples, the maximum strain of 120ppm was taken with regard to the 10wt.% phenol composite. This results indicate that the FeCoGe/phenol composites can be useful as an actuator because it has larger stain than the other solid state actuators such as piezo electric materials.

  • PDF

Load Cell Noise 제거를 위한 Digital Load Cell 에 대한 연구 (A study on a digital load cell for the removal of load cell noise)

  • 이영진;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.562-564
    • /
    • 2002
  • Noise reduction and a simplification of a precision measurement system has been performed by changing analog output mode of a load cell into digital output mode. Usually, analog output signal of a few $\mu V$ from a load cell are amplified by amp and acquired by A/D converter. If the distance from a load cell to a DAS(Data Acquisition System) increases, more noise signals are mixed. So, a microprocessor has been integrated into a load cell so that the amplification and A/D conversion of output signals could be done in close proximity to the lode cell for the reduction in mixing of noise. Obtained data from the load cell like this manner are transferred to a computer with digital values(of TTL level). To simplify the configuration of a multi-channel DAS, RS-485 communication system has used for data transfer.

  • PDF

주사전자현미경용 전자검출기의 설계 및 제작 (Design and Manufacture of an Electron Detector for Scanning Electron Microscope)

  • 전종업;김지원
    • 한국정밀공학회지
    • /
    • 제25권4호
    • /
    • pp.53-60
    • /
    • 2008
  • Electron detectors used in scanning electron microscope accept electrons emitted from the specimen and convert them to an electrical signal that, after amplification, is used to modulate the gray-level intensities on a cathode ray tube, producing an image of the specimen. Electron detector is one of the key components dominating the performance of scanning electron microscope so that the development of electron detectors having high performance is indispensable to acquire high quality images using scanning electron microscope. In this paper, we designed and manufactured an electron detector and conducted a couple of image capture experiments using it. In particular, scintillator which generates light photons when it is struck by high-energy electrons was manufactured and experimental studies on the optimization of manufacturing condition was carried out. From experiments to evaluate the performance of our detector, it was verified that the performance of our detector is equivalent to or better than that of the conventional one.

THE CONSTRAINED ITERATIVE IMAGE RESTORATION ALGORITHM USING NEW REGULARIZATION OPERATORS

  • Lee, Sang-Hwa;Lee, Choong-Woong
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 1997년도 Proceedings International Workshop on New Video Media Technology
    • /
    • pp.107-112
    • /
    • 1997
  • This paper proposes the regularized constrained iterative image restoration algorithms which apply new space-adaptive methods to degraded image signals, and analyzes the convergence condition of the proposed algorithm. First, we introduce space-adaptive regularization operators which change according to edge characteristics of local images in order to effectively prevent the restored edges and boundaries from reblurring. And, pseudo projection operator is used to reduce the ringing artifact which results from extensive amplification of noise components in the restoration process. The analysed algorithm is stable convergent to the fixed point. According to the experimental results for various signal-to-noise ratios(SNR) and blur models, the proposed algorithms other methods and is robust to noise effects and edge reblurring by regularization especially.

  • PDF