• Title/Summary/Keyword: Signal Intensity

Search Result 1,278, Processing Time 0.035 seconds

Usefulness of subtraction pelvic magnetic resonance imaging for detection of ovarian endometriosis

  • Lee, Hyun Jung
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.2
    • /
    • pp.90-97
    • /
    • 2020
  • Background: To minimize damage to the ovarian reserve, it is necessary to evaluate the follicular density in the ovarian tissue surrounding endometriosis on preoperative imaging. The purpose of the present study was to evaluate the usefulness of subtraction pelvic magnetic resonance imaging (MRI) to detect ovarian reserve. Methods: A subtracted T1-weighted image (subT1WI) was obtained by subtracting unenhanced T1WI from contrast-enhanced T1WI (ceT1WI) with similar parameters in 22 patients with ovarian endometriosis. The signal-to-noise ratio (SNR) in ovarian endometriosis, which was classified into the high signal intensity and iso-to-low signal intensity groups on the T2-weighted image, was compared to that in normal ovarian tissue. To evaluate the effect of contrast enhancement, a standardization map was obtained by dividing subT1WI by ceT1WI. Results: On visual assessment of 22 patients with ovarian endometriosis, 16 patients showed a high signal intensity, and 6 patients showed an iso-to-low signal intensity on T1WI. Although SNR in endometriosis with a high signal intensity was higher than that with an iso-to-low signal intensity, there was no difference in SNR after the subtraction (13.72±77.55 vs. 63.03±43.90, p=0.126). The area of the affected ovary was smaller than that of the normal ovary (121.10±22.48 vs. 380.51±75.87 ㎟, p=0.002), but the mean number of pixels in the viable remaining tissue of the affected ovary was similar to that of the normal ovary (0.53±0.09 vs. 0.47±0.09, p=0.682). Conclusion: The subtraction technique used with pelvic MRI could reveal the extent of endometrial invasion of the normal ovarian tissue and viable remnant ovarian tissue.

Magnetic Resonance Imaging and Pathologic Correlation of Cerebral Fat Embolism using Oleic Acid

  • Park, Byung-Rae
    • Biomedical Science Letters
    • /
    • v.10 no.2
    • /
    • pp.115-120
    • /
    • 2004
  • To investigate the correlation between the magnetic resonance imaging (MRI) of cerebral fat embolism that is induced by injecting oleic acid into 10 cats, and a pathologic diagnosis. Using a microcatheter, 30 ${mu}ell$ of oleic acid was injected into the internal carotid artery of 10 cats. MR T2-weighted image (T2WI), diffusion-weighted image (DWI) and Gadolinium-enhanced T1-weighted image (Gd-enhanced T1WI) were obtained after 30 minutes and 2 hours of embolization. After 30 minutes of the embolization, lesions of very high signal intensity were detected by T2WI in 6 cats, and of slightly high signal intensity in 2 cats; in the remaining 2 cats, signal intensity was normal. DWI showed lesions of very high intensity in 9 cats and of slightly high intensity in one cat. According to the findings of light microscopic examination, infarcted lesions mainly involved the gray matter, but also some white matter. A magnetic resonance imaging diagnosis for cerebral fat embolism that was induced by oleic acid through the internal carotid artery in cats showed high signal intensity on the T2WI and the DWI within an initial 2 hours, and with a well enhancement on the Gd-enhanced T1WI. Considering cellular edema, cerebrovascular injury and extracellular space widening, we assumed pathologically that cytotoxic and vasogenic edema exists at the same time.

  • PDF

A study on EPD(End Point Detection) controller on plasma teaching process (플라즈마 식각공정에서의 EPD(End Point Detection) 제어기에 관한 연구)

  • 최순혁;차상엽;이종민;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.415-418
    • /
    • 1996
  • Etching Process, one of the most important process in semiconductor fabrication, has input control part of which components are pressure, gas flow, RF power and etc., and plasma gas which is complex and not exactly understood is used to etch wafer in etching chamber. So this process has not real-time feedback controller based on input-output relation, then it uses EPD(End Point Detection) signal to determine when to start or when to stop etching. Various type EPD controller control etching process using EPD signal obtained from optical intensity of etching chamber. In development EPD controller we concentrate on compensation of this signal intensity and setting the relative signal magnitude at first of etching. We compensate signal intensity using neural network learning method and set the relative signal magnitude using fuzzy inference method. Potential of this method which improves EPD system capability is proved by experiences.

  • PDF

Measured Intensity Control Method of a Phase-shift Measurement Based Laser Scanner by using APD Bias Voltage Characteristic (위상 검출 방식 레이저 스캐너의 APD bias 전압 특성을 이용한 검출신호세기 제어 방법)

  • Jang, Jun-Hwan;Yoon, Hee-Sun;Hwang, Sung-Ui;Park, Kyi-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.10
    • /
    • pp.1096-1100
    • /
    • 2012
  • In the phase-shift measurement method, the distance light travels can be obtained based on the phase difference between the reference signal and the measured signal. When the object having various colors is measured, the intensity of the measured signal much varies even at the same distance, and it causes different phase delay due to wide dynamic range input to a signal processing circuit. In this work, an measured intensity control method is proposed to solve this phase delay problem.

ESR Spectroscopy for Detecting Gamma-Irradiated Shellfishes (방사선 조사된 조개류의 확인을 위한 ESR Spectroscopy의 이용)

  • 남혜선;양재승
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.1
    • /
    • pp.43-47
    • /
    • 2001
  • Electron spin resonance (ESR) spectroscopy was used to investigate the effect of irradiation dose on the ESR signal intensity and to identify the stability of radicals after 9 weeks of storage in order to detect irradiated shellfishes. The irradiated shellfishes (short-necked clam, purplish washington clam, freshwater clam, jackknifed clam, scallop and hard-shell mussel) presented an asymmetric absorption in shape at $g_{1}$=2.002~2.003 and $g_{2}$=1.998. The strength of the ESR signal increased linearly with the applied doses (1~7 kGy). A highly positive correlation coefficients ($R^{2}$=0.9136~0.9896) were obtained between the irradiation dose and corresponding ESR signal intensity. The intensity of the signals after irradiation was stable even after 9 weeks of storage at 5$\pm$1$^{\circ}C$.

  • PDF

The Optimal Signal Intensity according to Image Scale Reset of MRI (자기공명영상의 image scale 재설정에 따른 최적의 영상신호 표준화)

  • Lee, Ho-Beom;Choi, Kwan-Woo;Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.12
    • /
    • pp.266-271
    • /
    • 2017
  • In this study, we tried to improve the reproducibility of signal intensity by applying DOTS method. The study was conducted on 30 patients who had undergone hepatic screening because of poor reproducibility and decreased signal intensity. The images were acquired before and after injection of contrast media and then post-processed by DOTS methods. Signal intensity was compared and evaluated. The results showed that the signal intensity of the images was 183.3% ($1038.0{\pm}70.7$ before application, $2940.7{\pm}179.6$ after application) and 1118.4% ($444.1{\pm}92.4$, $5410.5{\pm}168.4$ after application). This is a significant improvement in the fact that the reproducibility of MRI) was changed by the DOTS method, which is a post-processing method.

Evaluation of the signal intensity of magnetic resonance angiography in accordance with the dilution rate of the contrast agent (조영제 희석률에 따른 조영증강 자기공명혈관조영검사의 신호강도 평가)

  • Choi, Kwan-Woo;Seo, Sung-Mi;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5124-5130
    • /
    • 2014
  • Dilution of the contrast agent by analyzing the change in the signal intensity during MR angiography in accordance with the viscosity and osmotic pressure minimizes the side effects, and improves the image quality. The contrast agent molarity changes by the dilution of the contrast agent in the blood, as it is injected, which leads to a change in signal intensity. Based on this principle, a phantom was prepared and experiments were performed. After the phantom experiment, a clinical experiment was conducted using the results of the phantom experiment. From November 2013 to January 2014, a group of patients were classified into diluted contrast agent (30 persons) and undiluted (30 persons), and the signal intensity of the cerebral vessels was compared. The signal intensity of the phantom according to the molarity of the contrast agent increased sharply from 0.0125 mmol, reached a peak at 20 mmol, and achieved equilibrium from 200 mmol. Based on the study results, the signal intensity of the blood vessels in the brain through were compared in a clinical experiment. All the brain vessels in the imaging range with diluting a high content of the gadolinium contrast agent showed high signal intensity. This result supports the phantom experiment and means that using the 500mmol diluted contrast agent is better than using 1000mmol undiluted contrast agent because it is easier to approach the 20mmol level needed to achieve the highest signal intensity. This study has significance in that it can minimize the high viscosity and osmotic pressure, which can cause side effects and improve the image quality using the method of the dilution rate.

Design of Algorithm for maximum Signal Sensing by Optical System (광시스템에서 maximum 신호 Sensing을 위한 Algorithm 설계)

  • Choi, Do-Sun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.4
    • /
    • pp.70-75
    • /
    • 2010
  • In this paper, was designed Algorithm Brent. this Algorithm can be used in the medical optical system. Optical signals are transmitted using optical fibers and integrated Optic. Developed Algorithm finds the maximum of the transmitted signal intensity. Optical system is made for Laser-Diode, HeNe-Laseer, controller for stepping motor, glass fiber and integrated Optic, etc. In this paper, two algorithms were investigated.

  • PDF

Association of Carotid Intraplaque Hemorrhage and Territorial Acute Infarction in Patients with Acute Neurological Symptoms Using Carotid Magnetization-Prepared Rapid Acquisition with Gradient-Echo

  • Park, Jung Soo;Kwak, Hyo Sung;Lee, Jong Myong;Koh, Eun Jeong;Chung, Gyung Ho;Hwang, Seung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.2
    • /
    • pp.94-99
    • /
    • 2015
  • Objective : The purpose of our study was to assess prevalence of carotid intraplaque hemorrhage (IPH) and associations between territorial acute infarction and IPH on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) in patients with acute neurologic symptoms. Methods : 83 patients with suspected acute neurologic symptoms were evaluated with both brain diffusion weighted imaging (DWI) and carotid MPRAGE sequences. Carotid plaque with high signal intensity on MPRAGE of >200% that of adjacent muscle was categorized as IPH. We analyzed the prevalence of IPH and its correlation with territorial acute infarction. Results : Of 166 arteries, 39 had a carotid artery plaque. Of these arteries, 26 had carotid artery stenosis less than 50%. In all carotid arteries, MR-depicted IPH was found in 7.2% (12/166). High-signal intensity on DWI was found in 17.5% (29/166). Combined lesion with ipsilateral high-signal intensity on DWI and IPH on carotid MPRAGE sequence was found in 6 lesions (6/166, 3.6%). Of patients with carotid artery plaque, MR-predicted IPH was found in 30.8% (12/39) and match lesions with high-signal intensity on DWI and MPRAGE was found in 15.4% (6/39). MR-predicted IPH was significantly higher prevalence in high-grade stenosis group (p=0.010). Relative risk between carotid MPRAGE-positive signal and ipsilateral high-signal intensity on DWI in arteries with carotid artery plaques was 6.8 (p=0.010). Conclusion : Carotid MPRAGE-positive signal in patients was associated with an increased risk of territorial acute infarction as detected objectively by brain DWI. The relative risk of stroke was increased in high-grade stenosis categories.

Perception of sentences varying with prosody pattern, sound intensity, and signal-to-noise ratio (운율 패턴, 강도, 신호대소음비에 따른 문장 지각 변화)

  • Chang, Son-A;Jang, Eunjoo;Jang, Jaejin
    • Phonetics and Speech Sciences
    • /
    • v.9 no.2
    • /
    • pp.119-124
    • /
    • 2017
  • This study investigates how perception of easy sentences varies with prosody pattern, sound intensity, and signal-to-noise ratio(SNR) in young adults with normal hearing who were in their 20's. The results showed that the presence of proper prosody pattern in the sentences increased correct perception rate of the target sentences, and that the lower the intensity and SNR, the lower the sentence perception scores. The results also showed that SNR had a greater effect on the sentence perception scores than sound intensity. There was a significant decrease of perception scores starting at the level of 15 dB and +3 SNR for the sentences with prosody pattern, while starting at the level of 18 dB and +6 SNR for the sentences without prosody pattern, ending up with a very poor perception score as sound intensity and SNR gets lower. There was a significant difference in the perception score of the sentences with prosody pattern between 20 year-old group and 21 year or older group in several listening conditions of sound intensity and SNR.