• Title/Summary/Keyword: Signal Factor

Search Result 1,835, Processing Time 0.028 seconds

The High Power Factor Control of a Single Phase PWM Converter using a Reduced-Order Luenberger Observer (축소차원 Luenberger 관측기를 이용한 단상 PWM 컨버터의 고역률 제어)

  • Yang, Lee-U;Kim, Yeong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.529-535
    • /
    • 2000
  • In this paper, a current control system of a single phase PWM AC/DC converter using a reduced-order Luenberger observer without source voltage sensors is proposed. The sinusoidal input current and unity input power factor are realised based on the estimated source voltage performed by the reduced-order Luenberger observer using actual currents and DC link voltage. The poles of the reduced-order Luenberger observer are placed in the left half plane of s-plane by the pole-placement method in order to acquire the stability of the observer. The magnitude and the phase of the estimated source voltage are used to accomplish the unity power factor. The proposed method is implemented by DSP(Digital Signal Processor). Experimental Results verify that the reduced-order observer estimates the source voltage without the estimation error and the control system accomplishes the unity power factor, and constant DC link voltage.

  • PDF

Ethyl Acetate Fraction from Petasites japonicus Attenuates Oxidative Stress through Regulation of Nuclear Factor E2-Related Factor-2 Signal Pathway in LLC-PK1 Cells (머위 에틸아세테이트 분획물의 LLC-PK1 세포에서의 Nrf-2 매개 항산화 효과)

  • Kim, Ji Hyun;Lee, Jaemin;Lee, Sanghyun;Cho, Eun Ju
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.1
    • /
    • pp.55-61
    • /
    • 2016
  • Antioxidant effects and nuclear factor E2-related factor-2 (Nrf-2) signal pathway of methanol extract and 4 fractions [n-hexane, methylene chloride, ethyl acetate (EtOAc), and n-butanol fractions] from Petasites japonicus were investigated. The EtOAc fraction showed highest polyphenol and flavonoid contents among other fractions. In addition, EtOAc fraction showed stronger scavenging activity against superoxide anion radical than other fractions. Furthermore, we investigated antioxidants effects of the EtOAc fraction under cellular system using $LLC-PK_1$ cells. The EtOAc fraction dose-dependently increased the antioxidant protein expressions of heme oxygenase 1 (HO-1) and thioredoxin reductase 1 (TrxR1) known to be involved in oxidative stress, through activation of Nrf-2. The treatment of EtOAc fraction ($100{\mu}g/mL$) led to the elevation of the high expression of Nrf-2-dependent factor such as HO-1 and TrxR1. These results indicated that the EtOAc fraction of P. japonicus showed high antioxidant activity by regulation of Nrf-2 signaling pathway.

A Study on the Optimum Design of Warm-up rate in a Air-Heated Heater System by Using CFD Analysis and Taguchi Method (전산유체해석과 다구찌 방법을 연계한 공기 가열식 히터 시스템의 난방속효성 최적화에 관한 연구)

  • Kim, Min-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.72-82
    • /
    • 2005
  • The objective of this paper is to describe the optimization of design parameters in a large-sized commercial bus heater system by using CFD(computational fluid dynamics) analysis and Taguchi method. In order to obtain the best combination of each control factor which results in a desired performance of heater system, the parameter design of the Taguchi method is adopted for the robust design considering the dynamic characteristic. The research activity may be divided into four phases. The first one is analyzing the problem, i.e., ascertaining the influential factors. In the second phase the levels were set in such a way that their variation would significantly influence the response. In the third phase the experimental runs were designed. In the final phase the planned runs were carried out numerically to evaluate the optimal combination of factors which is able to provide the best response. In this study, eight factors were considered for the analysis: one with two level and seven with three level combinations comprising the $L_{18}(2^1{\times}3^7)$ orthogonal array. The results of this study can be summarized as follows ; (i)The optimum condition of control factor is a set of <$A_2\;B_1\;C_3\;D_3\;E_1\;F_2\;G_3\;H_2$> where A is shape of the outer fin, B is pitch of the outer fin, C is height of the outer fin, D is the inner fin number, E is the inner fin height, F is length of the flame guide, G is diameter of the heating element and H is clearance between air guide and heating element. (ii)The heat capacity of heated discharge air under the optimum condition satisfies the equation y=0.6M w here M is a signal factor. (iii)The warm-up rate improves about three times, more largely as com pared with the current condition, which results in about 9.2minutes reduction.

The Performance Advancement of Power Analysis Attack Using Principal Component Analysis (주성분 분석을 이용한 전력 분석 공격의 성능 향상)

  • Kim, Hee-Seok;Kim, Hyun-Min;Park, Il-Hwan;Kim, Chang-Kyun;Ryu, Heui-Su;Park, Young-Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.20 no.6
    • /
    • pp.15-21
    • /
    • 2010
  • In the recent years, various researches about the signal processing have been presented to improve the performance of power analysis. Among these signal processing techniques, the research about the signal compression is not enough than a signal alignment and a noise reduction; even though that can reduce considerably the computation time for the power analysis. But, the existing compression method can sometimes reduce the performance of the power analysis because those are the unsophisticated method not considering the characteristic of the signal. In this paper, we propose the new PCA (principal component analysis)-based signal compression method, which can block the loss of the meaningful factor of the original signal as much as possible, considering the characteristic of the signal. Also, we prove the performance of our method by carrying out the experiment.

The Roles of Peroxiredoxin and Thioredoxin in Hydrogen Peroxide Sensing and in Signal Transduction

  • Netto, Luis E.S.;Antunes, Fernando
    • Molecules and Cells
    • /
    • v.39 no.1
    • /
    • pp.65-71
    • /
    • 2016
  • A challenge in the redox field is the elucidation of the molecular mechanisms, by which $H_2O_2$ mediates signal transduction in cells. This is relevant since redox pathways are disturbed in some pathologies. The transcription factor OxyR is the $H_2O_2$ sensor in bacteria, whereas Cys-based peroxidases are involved in the perception of this oxidant in eukaryotic cells. Three possible mechanisms may be involved in $H_2O_2$ signaling that are not mutually exclusive. In the simplest pathway, $H_2O_2$ signals through direct oxidation of the signaling protein, such as a phosphatase or a transcription factor. Although signaling proteins are frequently observed in the oxidized state in biological systems, in most cases their direct oxidation by $H_2O_2$ is too slow ($10^1M^{-1}s^{-1}$ range) to outcompete Cys-based peroxidases and glutathione. In some particular cellular compartments (such as vicinity of NADPH oxidases), it is possible that a signaling protein faces extremely high $H_2O_2$ concentrations, making the direct oxidation feasible. Alternatively, high $H_2O_2$ levels can hyperoxidize peroxiredoxins leading to local building up of $H_2O_2$ that then could oxidize a signaling protein (floodgate hypothesis). In a second model, $H_2O_2$ oxidizes Cys-based peroxidases that then through thiol-disulfide reshuffling would transmit the oxidized equivalents to the signaling protein. The third model of signaling is centered on the reducing substrate of Cys-based peroxidases that in most cases is thioredoxin. Is this model, peroxiredoxins would signal by modulating the thioredoxin redox status. More kinetic data is required to allow the identification of the complex network of thiol switches.

Firmness Measurement of Melon by Characteristics of Impact Signal (I) - Characteristics of Impact Signal of Melon - (충격신호 특성을 이용한 멜론의 경도측정(I) - 멜론의 충격신호특성 -)

  • Lee, Young-Hee;Choi, Dong-Soo;Choi, Seung-Ryul;Kim, Man-Soo;Kim, Ghi-Seok
    • Journal of Biosystems Engineering
    • /
    • v.33 no.4
    • /
    • pp.239-247
    • /
    • 2008
  • Firmness is very important factor to evaluate the freshness and ripeness among the various factors, in concerning about the melon quality. This study was carried out to develop the technique using impact signal to measure the melon firmness nondestructively. Results of analyzing impulse signals of melons having different firmness levels showed that the firmness of melon affected various impulse responses including amplitude, transmitted time, maximum peak frequency, firmness index 1 ($f^2m$), and firmness index 2 ($f^2m^{2/3}$). Impulse signal amplitude was the best indicator to predict the firmness of melon because of a strong corelation ($R^2\;=\;0.9071$). Firmness index 1, firmness index 2, maximum peak frequency, and normalized transmitted time were also possible indicators with acceptable correlation values.

The Glucoamylase Signal Sequence Directs the Efficient Secretion of Human $\alpha$1-Antitrypsin in Yeast Cells (효모에서 Glucoamylase 신호서열에 의한 인체 $\alpha$1-Antitrypsin의 분비 효율 향상)

  • Song, Moo-Young;Kwon, Ki-Sun;Kang, Dae-Ook;Yu, Myeong-Hee;Park, Hee-Moon;Kim, Jinmi
    • Korean Journal of Microbiology
    • /
    • v.31 no.3
    • /
    • pp.203-207
    • /
    • 1993
  • Five different secretion vectors were constructed by varying the signal sequences and .alpha.-antitrypsin (.alpha.1-AT) a numan secretory protein, was produced from yeast cells. The signal sequences used are those of acid phosphatase (PH05) and .alpha.-factor (M f.alphal1) of Saccharomyces cerevisiae, glucoamylase (STA1) of Saccharomyces diastaticus, and human .alpha.1-AT. Four vectors directed the efficient secretion of .alpha.1-AT ito the culture media. The secretion vector carrying the glucoamylase signal sequence (pGAT11) showed the highest efficiency of secretion. About 70% of .alpha.1-AT produce dwere secreted into the media. The endo H treatment of partially purified .alpha.1-AT indicates that the secreted .alpha.1-AT appeared to be glycosylated. This glycosylation pattern was altered when amino acid substitution mutations were introduced at the three glycosylation sites of .alpha.-AT.

  • PDF

A 4x Time-Domain Interpolation 6-bit 3.4 GS/s 12.6 mW Flash ADC in 65 nm CMOS

  • Liu, Jianwei;Chan, Chi-Hang;Sin, Sai-Weng;U, Seng-Pan;Martins, Rui Paulo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.4
    • /
    • pp.395-404
    • /
    • 2016
  • A 6-bit 3.4 GS/s flash ADC in a 65 nm CMOS process is reported along with the proposed 4x time-domain interpolation technique which allows the reduction of the number of comparators from the conventional $2^N-1$ to $2^{N-2}$ in a N-bit flash ADC. The proposed scheme effectively achieves a 4x interpolation factor with simple SR-latches without extra clocking and calibration hardware overhead in the interpolated stage where only offset between the $2^{N-2}$ comparators needs to be calibrated. The offset in SR-latches is within ${\pm}0.5$ LSB in the reported ADC under a wide range of process, voltage supply, and temperature (PVT). The design considerations of the proposed technique are detailed in this paper. The prototype achieves 3.4 GS/s with 5.4-bit ENOB at Nyquist and consumes 12.6 mW power at 1 V supply, yielding a Walden FoM of 89 fJ/conversion-step.

The Experimental Study on Optical Characteristics of a Detector by Turbidity Variance (탁도 변화에 따른 검출기의 광원특성에 관한 실험적 고찰)

  • Kim, Young-Do;Lee, Kye-Bock
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.6
    • /
    • pp.50-56
    • /
    • 2007
  • In this study, we have performed some experimental works on the effects of variation of low, middle and high turbidity for understanding of optical characteristics which is very important factor for the turbidity measurement. The various output frequencies were obtained by the experimental apparatus which consist of detectors, a light source, a frequency counter and so on. From the result of analysis of these frequencies, Firstly, The difference of signal value for each degrees of low turbidity was the smallest of three scopes around the Nephelometric position. Second, the characteristics of each degrees of middle turbidity was proved that signal values of all degrees were larger those of low turbidity but the difference of each signal value of the forward direction was smaller than that of the backward direction. Third, the characteristics of each degrees of high turbidity was proved that though similar to the characteristics of middle turbidity, each signal value of all degrees was larger and the difference of each signal value of all degrees was smaller than those of low and middle turbidity

Switching performances of multivarite VSI chart for simultaneous monitoring correlation coefficients of related quality variables

  • Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.2
    • /
    • pp.451-459
    • /
    • 2017
  • There are many researches showing that when a process change has occurred, variable sampling intervals (VSI) control chart is better than the fixed sampling interval (FSI) control chart in terms of reducing the required time to signal. When the process engineers use VSI control procedure, frequent switching between different sampling intervals can be a complicating factor. However, average number of samples to signal (ANSS), which is the amount of required samples to signal, and average time to signal (ATS) do not provide any control statistics about switching performances of VSI charts. In this study, we evaluate numerical switching performances of multivariate VSI EWMA chart including average number of switches to signal (ANSW) and average switching rate (ASWR). In addition, numerical study has been carried out to examine how to improve the performance of considered chart with accumulate-combine approach under several different smoothing constant and sample size. In conclusion, process engineers, who want to manage the correlation coefficients of related quality variables, are recommended to make sample size as large and smoothing constant as small as possible under permission of process conditions.