• Title/Summary/Keyword: Signal Evaluation

Search Result 1,915, Processing Time 0.028 seconds

A Scheduler for Multimedia Data and Evaluation Method (멀티미디어 데이터를 위한 스케쥴러 및 평가법 설계)

  • 유명련;김현철
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.2
    • /
    • pp.1-7
    • /
    • 2002
  • Since multimedia data such as video and audio data are displayed within a certain time constraint, their computation and manipulation should be handled under limited condition. Traditional real-time scheduling algorithms could not be directly applicable, because they are not suitable for multimedia scheduling applications which support many clients at the same time. Rate Regulating Proportional Share Scheduling Algorithm is a scheduling algorithm considered the time constraint of the multimedia data. This scheduling algorithm uses a rate regulator which prevents tasks from receiving more resource than its share in a given period. But this algorithm loses fairness, and does not show graceful degradation of performance under overloaded situation. This paper proposes a new modified algorithm, namely Modified Proportional Share Scheduling Algorithm considering the characteristics of multimedia data such as its continuity and time dependency. Proposed scheduling algorithm shows graceful degradation of performance in overloaded situation and the reduction in the number of context switching. Furthermore, a new evaluation method is proposed which can evaluate the flexibility of scheduling algorithm.

  • PDF

Integration of immunohistochemical reactions into Electrochemical and Optical Analyses of Biochips (면역 조직화학 반응이 통합된 바이오칩의 전기화학 및 광학적 분석)

  • Choi Hyoung Gil;Hong Eun Kyoung;Lee Seung-Won;Yoon Hyun C.
    • KSBB Journal
    • /
    • v.20 no.2 s.91
    • /
    • pp.123-128
    • /
    • 2005
  • We have addressed two important issues of immunosensing biochips, including the construction of antibody functionalized suface for efficient affinity reactions and the development of a signal registration strategy that converts biospecific reactions into highly quantifiable electrochemical and/or optical signals. The developed immunoassay reaction is an integrated version of enzyme-mediated immunoprecipitaion reaction, which is widely used in immunohistochemistry, and electrochemical signaling reaction. For the evaluation of analytical performance of fabricated immunosensing biochips, signaling for mouse IgG in antiserum was conducted. Applications of the developed strategy have been found for the evaluation of histology chemicals and for the signal amplification for array-type biochip analysis.

An Assessment of the Prestress Force on the Bonded Tendon Using the Strain and the Stress Wave Velocity (변형률과 응력파속도를 이용한 부착식 텐던의 긴장력 평가)

  • Jang, Jung Bum;Hwang, Kyeong Min;Lee, Hong Pyo;Kim, Byeong Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3A
    • /
    • pp.183-188
    • /
    • 2012
  • The bonded tendon was adopted to the reactor containment building of some operating nuclear power plants in Korea and the assessment of the prestress force on the bonded tendon is very important for the evaluation of the structural integrity. The prestress force of the bonded tendon at real reactor containment building, was evaluated using the SI technique and impact signal analysis technique which were developed to improve the existing indirect assessmment technique. For these techniques, the strain of the reactor containment building and the stress wave velocity of the bonded tendon were measured. Both SI technique and impact signal analysis technique give the highly reliable results comparison with the existing theoretical approach. Therefore, it is confirmed that the developed techniques are very useful for the evaluation of the prestress force on the bonded tendon.

Evaluation of GaN Transistors Having Two Different Gate-Lengths for Class-S PA Design

  • Park, Jun-Chul;Yoo, Chan-Sei;Kim, Dongsu;Lee, Woo-Sung;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.3
    • /
    • pp.284-292
    • /
    • 2014
  • This paper presents a characteristic evaluation of commercial gallium nitride (GaN) transistors having two different gate-lengths of $0.4-{\mu}m$ and $0.25-{\mu}m$ in the design of a class-S power amplifier (PA). Class-S PA is operated by a random pulse-width input signal from band-pass delta-sigma modulation and has to deal with harmonics that consider quantization noise. Although a transistor having a short gate-length has an advantage of efficient operation at higher frequency for harmonics of the pulse signal, several problems can arise, such as the cost and export license of a $0.25-{\mu}m$ transistor. The possibility of using a $0.4-{\mu}m$ transistor on a class-S PA at 955 MHz is evaluated by comparing the frequency characteristics of GaN transistors having two different gate-lengths and extracting the intrinsic parameters as a shape of the simplified switch-based model. In addition, the effectiveness of the switch model is evaluated by currentmode class-D (CMCD) simulation. Finally, device characteristics are compared in terms of current-mode class-S PA. The analyses of the CMCD PA reveal that although the efficiency of $0.4-{\mu}m$ transistor decreases more as the operating frequency increases from 955 MHz to 3,500 MHz due to the efficiency limitation at the higher frequency region, it shows similar power and efficiency of 41.6 dBm and 49%, respectively, at 955 MHz when compared to the $0.25-{\mu}m$ transistor.

Development of an Portable Urine Glucose Monitoring System (휴대용 뇨당 측정 시스템의 개발)

  • 박호동;이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.397-403
    • /
    • 2002
  • Urine glucose monitoring system is a self-monitoring system that display the glucose level by non-invasive measurement method. In this paper, We developed a noninvasive urine glucose monitoring system that improved defects of urine glucose measurement with a colorimeter method and invasive blood glucose measurement method. This system consist of bio-chemical sensor for urine glucose measurements, signal detecting part, digital and signal analysis part, display part and power supplying part. The developed bio-chemical sensor for the measurement of urine glucose has good reproducibility, convenience of handing and can be mass-produced with cheap price. To evaluate the performance of the developed system, We performed the evaluation of confidence about the detection of glucose level by a comparison between a standard instrument in measuring glucose level and the developed system using standard glucose solutions mixed with urine. Standard error was 2.85282 from the evaluation of confidence based on regression analysis. Also, In analysis of S.D(standard deviation) and C.V(coefficient of validation) that are important parameters to evaluate system using bio-chemical sensor, S.D was 10% which falls under clinically valid value, 15%, and C.V was under 5%. Consequently from the above results, compared to blood glucose measurement, the system performance is satisfactory.

Non-hierarchical Clustering based Hybrid Recommendation using Context Knowledge (상황 지식을 이용한 비계층적 군집 기반 하이브리드 추천)

  • Baek, Ji-Won;Kim, Min-Jeong;Park, Roy C.;Jung, Hoill;Chung, Kyungyong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.3
    • /
    • pp.138-144
    • /
    • 2019
  • In a modern society, people are concerned seriously about their travel destinations depending on time, economic problem. In this paper, we propose an non-hierarchical clustering based hybrid recommendation using context knowledge. The proposed method is personalized way of recommended knowledge about preferred travel places according to the user's location, place, and weather. Based on 14 attributes from the data collected through the survey, users with similar characteristics are grouped using a non-hierarchical clustering based hybrid recommendation. This makes more accurate recommendation by weighting implicit and explicit data. The users can be recommended a preferred travel destination without spending unnecessary time. The performance evaluation uses accuracy, recall, F-measure. The evaluation result was shown 0.636 accuracy, 0.723 recall, and 0.676 F-measure.

Accuracy Evaluation of Brain Parenchymal MRI Image Classification Using Inception V3 (Inception V3를 이용한 뇌 실질 MRI 영상 분류의 정확도 평가)

  • Kim, Ji-Yul;Ye, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.3
    • /
    • pp.132-137
    • /
    • 2019
  • The amount of data generated from medical images is increasingly exceeding the limits of professional visual analysis, and the need for automated medical image analysis is increasing. For this reason, this study evaluated the classification and accuracy according to the presence or absence of tumor using Inception V3 deep learning model, using MRI medical images showing normal and tumor findings. As a result, the accuracy of the deep learning model was 90% for the training data set and 86% for the validation data set. The loss rate was 0.56 for the training data set and 1.28 for the validation data set. In future studies, it is necessary to secure the data of publicly available medical images to improve the performance of the deep learning model and to ensure the reliability of the evaluation, and to implement modeling by improving the accuracy of labeling through labeling classification.

A Composite DorsoPlantar Axial X-ray Projection Study on the Bones of the Whole Infant's Foot (유아 발 전체의 뼈에 대한 합성 전후축방향 엑스선촬영법 연구)

  • Park, Yun;Ahn, Byung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1007-1013
    • /
    • 2021
  • A Study that Cronbach Alpha values were Significantly higher at 0.813 in the Composite AP axial Radiography Signal to Noise Ratio(SNR) for Evaluating uniform Density and Advanced Images of the Entire Foot without overlap with the legs. The Subjective Evaluation ROC also scored a high score of 18 on Foot Calcaneus bone 10° from the Foot Metatarsal bone, and 18 on the Examination by tilting the Sharpness X-ray Tube 20° from the Foot Calcaneus bone. Results show uniform Density and images at 10° rearward of Foot Metatarsal bone and 20° forward of Foot Calcaneus bone during the Composite AP axial Radiography X-ray Examination of Infants.

A Study on the Development of Smart Helmet for Forest Firefighting Crews (산불진화대원용 스마트 헬멧 개발에 관한 연구)

  • Ha, Yeon-Chul;Jin, Young-Woo;Park, Jae-Mun;Doh, Hee-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.57-63
    • /
    • 2021
  • The purpose of this study is to develop a Smart Helmet to safeguard forest firefighting crews and provide on-site information in real time. The Smart Helmet for forest firefingting crews is equipped with a camera, video/voice communication module, GPS, Bluetooth, and LTE module to promote the safety of them, and through the Smart Helmet, the site situation is is transmitted in real time, and full duplex communication is possible. As a result of testing using the Smart Helmet, the control center was able to receive on-site information and communication with on-site forest firefighting crews. Through site evaluation and user evaluation, it was confirmed that the Smart Helmet needs to be improved. The developed Smart Helmet can be used in various ways in forest disasters and forest industry.

Technical Evaluation of Engineering Model of Ultra-Small Transmitter Mounted on Sweetpotato Hornworm

  • Nakajima, Isao;Muraki, Yoshiya;Mitsuhashi, Kokuryo;Juzoji, Hiroshi;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • v.9 no.2
    • /
    • pp.145-154
    • /
    • 2022
  • The authors are making a prototype flexible board of a radio-frequency transmitter for measuring an electromyogram (EMG) of a flying moth and plan to apply for an experimental station license from the Ministry of Internal Affairs and Communications of Japan in the summer of 2022. The goal is to create a continuous low-dose exposure standard that incorporates scientific and physiological functional assessments to replace the current standard based on lethal dose 50. This paper describes the technical evaluation of the hardware. The signal of a bipolar EMG electrode is amplified by an operational amplifier. This potential is added to a voltage-controlled crystal oscillator (27 MHz, bandwidth: 4 kHz), frequency-converted, and transmitted from an antenna about 10 cm long (diameter: 0.03 mm). The power source is a 1.55-V wristwatch battery that has a total weight of about 0.3 g (one dry battery and analog circuit) and an expected operating time of 20 minutes. The output power is -7 dBm and the effective isotropic radiated power is -40 dBm. The signal is received by a dual-whip antenna (2.15 dBi) at a distance of about 100 m from the moth. The link margin of the communication circuit is above 30 dB within 100 m. The concepts of this hardware and the measurement data are presented in this paper. This will be the first biological data transmission from a moth with an official license. In future, this telemetry system will improve the detection of physiological abnormalities of moths.