• Title/Summary/Keyword: Signal Evaluation

Search Result 1,915, Processing Time 0.03 seconds

An Investigation into the Measured Values of Driver's Subjective and Objective Sensibility Response Stimulated by Different Car Noises (서로 다른 자동차소음에 대한 운전자의 주관적 및 객관적 감성반응 측정치에 관한 조사)

  • Kim, Tae Hyun;Cho, Jae Hoon;Cho, Won Hak;Lee, Moon Sub;Choi, Hyeon Ki
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.42 no.1
    • /
    • pp.73-79
    • /
    • 2016
  • The purpose of this study is to understand human sensory and emotional response according to car noise. This study investigated human stress levels from car noise based on the data of electro-encephalogram (EEG) and subjective evaluation analysis data. Since there are few previous works on the effect of car noise on human's reaction, more profound research about the effect of car noise on driver's emotion would be worth performing. Subjects were exposed to five different kinds of car noises. EEG data were collected while the subject was exposed to noise. In order to process EEG data, FFT analysis was used to separate the collected EEG data into ${\alpha}$-wave and ${\beta}$-wave. Also, survey was performed to carry out subjective evaluation. The results of the subjective evaluation were closely correlated to those found in the EEG signal analysis. The results from this study may provide useful information for mitigating car noise induced stress.

A Study on the Fluid Leakage Evaluation for Power Plant Valve Using Acoustic Imaging Technique (음향 영상화기법을 이용한 발전용 밸브 유체누설평가 연구)

  • Lee, S G.;Lee, S.K.;Kim, D.W.
    • Journal of Power System Engineering
    • /
    • v.15 no.1
    • /
    • pp.18-23
    • /
    • 2011
  • Image processing has provided powerful techniques to extract from the acoustic signals the desired information on evaluation for leakage existence, leakage rate, and searching for leakage location, etc. The imagery NDE data available can add additional and significant dimension in nondestructive evaluation(NDE) information and thus for exploiting in applications. To extract such information the use of advanced image processing techniques is much needed. In recent years, there has been much increased use of acoustic signal image processing techniques in acoustic NDE. This approach will increase the efficiency of inspection procedures and reduce inspection time. In this paper we are concerned only with This paper is concerned mainly with the use of advanced image processing techniques in valve leakage detection and advanced image restoration and enhancement methods, which attempt to evaluate promptly by a visualization method the acoustic sources while detecting the valve leakage.

Accuracy Enhancement of Reflection Signals in Impact Echo Test

  • Lho, Byeong-Cheol
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.924-929
    • /
    • 2003
  • A majority of infrastructures has been deteriorated over time. Therefore, it is very important to verify the quality of construction, and the level of structural deterioration in existing structures, to ensure their safety and functionality. Many researchers have studied non-destructive testing (NDT) methods to identify structural problems in existing structures. The impact echo technique is one of the widely used NDT techniques. The impact echo technique has several inherent problems, including the difficulties in P-wave velocity evaluation due to inhomogeneous concrete properties, deterioration of evaluation accuracy where multiple reflection boundaries exist, and the influence of the receiver location in evaluating the thickness of the tested structures. Therefore, the objective of this paper is to propose an enhanced impact echo technique that can reduce the aforementioned problems and develop a Virtual Instrument for the application via a thickness evaluation technique which has same technical background to find deterioration in concrete structures. In the proposed impact echo technique, transfer function from dual channel system analysis is used, and coherence is improved to achieve reliable data. Also an averaged signal -ensemble- is used to achieve more reliable results. From the analysis of transfer function, the thickness is effectively identified.

Time-Frequency Analysis of Lamb wave mode (램파모드의 시간-주파수 해석)

  • 박익근;안형근
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.133-140
    • /
    • 2001
  • Recently, to assure the integrity of a structural components such as piping pressure vessels and thinning structure, Lamb wave inspection technique has been used in material evaluation. It is very important to select the optimal Lamb wave mode and to analyze the signal accurately because of its unique dispersion properties grnerating several modes within the speci-men. It this study, the feasibility of material evaluation applications using wavelet analysis of Lamb wave has been veir-fied experimentally. These results show as follows; 1)dispersion characteristic of each mode in dispersion curve is demon-strated that A0 mode propagating material surface is useful mode having the lest energy loss and not sensitive to surface condition. 2) it can be detected even the micro defect ($1\times2mm$) fabricated in ultrasonic probe flaw distance (290mm) to axis direction. 3) the wavelet transform which is called "time-frequency analysis" shows the Lamb wave propagation due to the change of materials characterization can be evaluated at each frequency and experimental group velocity of Lamb wave agrees quite well with that of simulated dispersion curve.ion curve.

  • PDF

Comparison of vascular compliance between normal and replanted fingers using second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상과 재접합 손가락의 혈관 탄성도 비교)

  • Kim, Sung-Woo;Kim, Jin-Tae;Hong, Hyun-Ki;Kim, Soo-Chan;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.42-44
    • /
    • 2006
  • Up to the present, finger replantation patients have complained about various symptoms because of blood circulatory failure. Objective evaluation methods for the level of the blood circulatory failures in fingers were needed other than patient's subjective symptoms and complaints. Photoplethysmogram(PPG) measured from fingers is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular. Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, vascular compliance study for finger replantation patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal and replanted finger vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a represents vascular compliance. Study found out that when vascular compliance is decreased, b/a is increased, the absolute value of b/a is decreased. For 43 finger replantation patients, the average vascular compliance of replanted finger is lower than the normal finger statistically(p=0.001). we suggested an objective evaluation of finger vascular compliance for finger replantation patients and effect of surgical operation.

  • PDF

Reliability Evaluation of the Partial Discharge Measuring Sensor for Hydro Generator (대용량 수차발전기 부분방전 검출용 센서의 신뢰성 평가)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.40-45
    • /
    • 2006
  • In the operation of large capacity hydro generators, it's a very important thing that to minimize several kind of electrical trouble and accident. In order to overcome these problems, the on-line and off-line partial discharge (PD) measuring method has become an important one. Nowadays, epoxy mica coupler(EMC) has been the most widely used sensors for on-line PD detection in rotating machines. This time, we have made a ceramic coupling sensor using $SrTiO_{3}$, because at present, most of sensors has high cost and difficult procedure to making. This paper deals with the electrical characteristics of a ceramic coupling sensor, which has been made to continuously measure PD activity during the operation condition for 13kV class hydro generator. And we have performed the evaluation of sensor life and reliability based on the characteristic testing. The experimental results confirm that the sensor has satisfied at electrical required performance and output characteristic for simulated input signal.

Differential Gene Expression after Adenovirus-Mediated p16 Gene Transfer in Human Non-Small Cell Lung Cancer Cells (폐암세포주에서 아데노바이러스 매개 p16 유전자 전달로 인한 유전자 발현의 변화)

  • 박미선;김옥희;박현신;지승완;엄미옥;염태경;강호일
    • Toxicological Research
    • /
    • v.20 no.2
    • /
    • pp.109-116
    • /
    • 2004
  • For the safety evaluation of adenovirus-mediated gene transfer, we investigated differential gene expressions after transfecting adenoviral vector containing p16 tumor suppressor gene (Ad5CMV-p16) into human non-small cell lung cancer cells. In the previous study, we showed adenovirus-mediated $p16^{INK4a}$ gene transfer resulted in significant inhibition of cancer cell growth. We investigated gene expression changes after transfecting Ad5CMV-p16, Ad5CMV (null type, a mock vector) into A549 cells by using cDNA chip and oligonucleotide microarray chip (1200 genes) which carries genes related with signal transduction pathways, cell cycle regulations, oncogenes and tumor suppressor genes. We found that $p16^{INK4a}$ gene transfer down regulated 5 genes (cdc2, cyclin D3, cyclin B, cyclin E, cdk2) among 26 genes involved in cell cycle regulations. Compared with serum-free medium treated cells, Ad5CMV-p16 changed 27 gene expressions, two fold or more on oligonucleotide chip. In addition, Ad5CMV-p16 did not seem to increase the tumorigenicity-related gene expression in A549 cells. Further studies will be needed to investigate the effect of Ad5CMV-p16 on normal human cells and tissues for safety evaluation.

Ground Test and Evaluation of a Flight Control Systemfor Unmanned Aerial Vehicles

  • Suk, Jin-Young
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.5 no.1
    • /
    • pp.57-63
    • /
    • 2004
  • UAV(Unmanned Aerial Vehicle) has become one of the most popularmilitary/commercial aerial robots in the new millennium. In spite of all theadvantages that UAVs inherently have, it is not an easv job to develop a UAVbecause it requires very systematic and complete approaches in full developmentenvelop. The ground test and evaluation phase has the utmost importance in thesense that a well-developed system can be best verified on the ground. In addition,many of the aircraft crashes in the flight tests were resulted from the incompletedevelopment procedure. In this research, a verification procedure of the wholeairbome integrated system was conducted including the flight management system.An airbome flight control computer(FCC) senses the extemal environment from thepehpheral devices and sends the control signal to the actuating system using theassigned control logic and flight test strategy. A ground test station controls themission during the test while the downlink data are transferred from the flightmanagement computer using the serial communication interface. The pilot controlbox also applies additional manual actuating commands. The whole system wastested/verified on the wind-tunnel system, which gave a good pitch controlperformance with a preUspecified flight test procedure. The ground test systemguarantees the performance of fundamental functions of airbome electronic systemfor the future flight tests.

Performance Evaluation of Synchronization Method for Reducing the Overall Synchronization Time in Digital Radio Mondiale Receivers

  • Kwon, Ki-Won;Kim, Seong-Jun;Hwang, Jun;Paik, Jong-Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.8
    • /
    • pp.1860-1875
    • /
    • 2013
  • In this paper, we present a comparative performance evaluation of the sampling frequency synchronization method that eliminates the initial sampling frequency offset (SFO) to reduce the overall synchronization time in Digital Radio Mondiale (DRM) receivers. To satisfy the advanced synchronization performance requirements of DRM receivers, we introduce the conventional DRM synchronization method (Method 1) and another method (Method 2), which does not perform the initial sampling frequency synchronization in the conventional synchronization method (both methods are mentioned later in this paper). To demonstrate the effectiveness of the performance evaluation, analytical expressions for frame detection are derived and simulations are provided. Based on the simulations and numerical analysis, our result shows that Method 2, with a negligible performance loss, is robust to the effects of the initial sampling frequency synchronization even if SFO is present in the DRM signal. In addition, we verify that the inter-cell differential correlation used between reference cells is robust to the effect of the initial SFO.

Another View Point on the Performance Evaluation of an MC-DS-CDMA System

  • Chen, Joy Iong-Zong;Hsieh, Tai Wen
    • Journal of Communications and Networks
    • /
    • v.11 no.3
    • /
    • pp.240-247
    • /
    • 2009
  • The results of performance analysis by adopting the channel scenarios characterized as Weibull fading for an multicarrierdirect sequence-coded division multiple access (MC-DS-CDMA) system are proposed in this investigation. On the other hand, an approximate simple expression with the criterion of bit error rate (BER) versus signal-to-noise ratio (SNR) method is derived for an MC-DS-CDMA system combining with maximal ratio combining (MRC) diversity based on the moment generating function (MGF) formula of Weibull statistics, and it associates with an alternative expression of Gaussian Q-function. Besides, the other point of view on the BER performance evaluation of an MC-DS-CDMA system is not only the assumption of both single-user and multi-user cases applied, but the phenomena of partial band interference (PBI) is also included. Moreover, in order to validate the accuracy in the derived formulas, some of the system parameters, such as Weibull fading parameter (${\beta}$), user number (K), spreading chip number (N), branch number (L), and the PBI (JSR) values, etc., are compared with each other in the numerical results. To the best of author's knowledge, it is a brand new idea which proposes the evaluation of the system performance for an MC-DS-CDMA system over the point of view with Weibull fading channel.