• Title/Summary/Keyword: Signal Evaluation

Search Result 1,915, Processing Time 0.032 seconds

Evaluation of the signal intensity of magnetic resonance angiography in accordance with the dilution rate of the contrast agent (조영제 희석률에 따른 조영증강 자기공명혈관조영검사의 신호강도 평가)

  • Choi, Kwan-Woo;Seo, Sung-Mi;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5124-5130
    • /
    • 2014
  • Dilution of the contrast agent by analyzing the change in the signal intensity during MR angiography in accordance with the viscosity and osmotic pressure minimizes the side effects, and improves the image quality. The contrast agent molarity changes by the dilution of the contrast agent in the blood, as it is injected, which leads to a change in signal intensity. Based on this principle, a phantom was prepared and experiments were performed. After the phantom experiment, a clinical experiment was conducted using the results of the phantom experiment. From November 2013 to January 2014, a group of patients were classified into diluted contrast agent (30 persons) and undiluted (30 persons), and the signal intensity of the cerebral vessels was compared. The signal intensity of the phantom according to the molarity of the contrast agent increased sharply from 0.0125 mmol, reached a peak at 20 mmol, and achieved equilibrium from 200 mmol. Based on the study results, the signal intensity of the blood vessels in the brain through were compared in a clinical experiment. All the brain vessels in the imaging range with diluting a high content of the gadolinium contrast agent showed high signal intensity. This result supports the phantom experiment and means that using the 500mmol diluted contrast agent is better than using 1000mmol undiluted contrast agent because it is easier to approach the 20mmol level needed to achieve the highest signal intensity. This study has significance in that it can minimize the high viscosity and osmotic pressure, which can cause side effects and improve the image quality using the method of the dilution rate.

Evaluation of Effect of Decrease in Metallic Artifacts using the Synthetic MR Technique (Synthetic MR 기법을 이용한 금속 인공물 감소 효과 평가)

  • Soon-Yong, Kwon;Nam-Yong, Ahn;Jeong-Eun, Oh;Seong-Ho, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.835-842
    • /
    • 2022
  • This study is aimed to evaluate the effects of a synthetic MR technique in reducing metal artifacts. In the experiment, the in-plane and through-plane images were acquired by applying a synthetic MR technique and a high-speed spin echo technique to a phantom manufactured with screw for spinal surgery. The area of the metal artifact was compared. The metal artifacts were measured by dividing the signal-loss and the signal pile-up areas, and the area of the final artifact was calculated through the sum of the two. As a result, the metal artifacts were relatively reduced when the synthetic MR techniques were applied to both in-plane and through-plane. Comparing by sequence, the in-plane T1 images decreased by 23.45%, T2 images by 20.85%, PD images by 19.67%, and FLAIR images by 22.12%. Also, in the case of the through-plane, the T1 image decreased by 62.95%, the T2 image decreased by 73.93%, the PD image decreased by 74.68%, and the FLAIR image decreased by 66.43%. The cause of this result is that when the synthetic MR technique is applied, the distortion is due to the signal pile-up and does not occur and the size of the entire metal artifact is reduced. Therefore, synthetic MR technique can very effectively reduce metal artifacts, which can help to increase the diagnostic value of images.

Development of WMTS Module Based Pulse Rate Period Detection and Human Sensibility Evaluation System (WMTS 무선통신 모듈을 이용한 맥파의 주기검출 및 감성평가 시스템 개발)

  • Lee, Hyun-Min;Kim, Dong-Jun;Jeon, Ki-Man;Son, Jae-Gi
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.811-817
    • /
    • 2013
  • In this study we present a system for pulse-rate period detection and human sensibility evaluation based on the wireless medical telemetry service (WMTS) used for transmission of data from medical telemetry devices to various medical facilities and services. We develop a medical-purpose specific WMTS communication module to transmit biometric signals. From the pulse rate variability(PRV) signal, we attempt to classify positive and negative emotional states based on analysis of the ratio of LF/HF in the frequency domain. We measure the data reception rate according to distance in order to test the performance of the WMTS module and analyze the effects on human sensibility evaluation.

Analysis of Quantization Noise in Magnetic Resonance Imaging Systems (자기공명영상 시스템의 양자화잡음 분석)

  • Ahn C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.42-49
    • /
    • 2004
  • Purpose : The quantization noise in magnetic resonance imaging (MRI) systems is analyzed. The signal-to-quantization noise ratio (SQNR) in the reconstructed image is derived from the level of quantization in the signal in spatial frequency domain. Based on the derived formula, the SQNRs in various main magnetic fields with different receiver systems are evaluated. From the evaluation, the quantization noise could be a major noise source determining overall system signal-to-noise ratio (SNR) in high field MRI system. A few methods to reduce the quantization noise are suggested. Materials and methods : In Fourier imaging methods, spin density distribution is encoded by phase and frequency encoding gradients in such a way that it becomes a distribution in the spatial frequency domain. Thus the quantization noise in the spatial frequency domain is expressed in terms of the SQNR in the reconstructed image. The validity of the derived formula is confirmed by experiments and computer simulation. Results : Using the derived formula, the SQNRs in various main magnetic fields with various receiver systems are evaluated. Since the quantization noise is proportional to the signal amplitude, yet it cannot be reduced by simple signal averaging, it could be a serious problem in high field imaging. In many receiver systems employing analog-to-digital converters (ADC) of 16 bits/sample, the quantization noise could be a major noise source limiting overall system SNR, especially in a high field imaging. Conclusion : The field strength of MRI system keeps going higher for functional imaging and spectroscopy. In high field MRI system, signal amplitude becomes larger with more susceptibility effect and wider spectral separation. Since the quantization noise is proportional to the signal amplitude, if the conversion bits of the ADCs in the receiver system are not large enough, the increase of signal amplitude may not be fully utilized for the SNR enhancement due to the increase of the quantization noise. Evaluation of the SQNR for various systems using the formula shows that the quantization noise could be a major noise source limiting overall system SNR, especially in three dimensional imaging in a high field imaging. Oversampling and off-center sampling would be an alternative solution to reduce the quantization noise without replacement of the receiver system.

  • PDF

Detection Characteristics of Gamma-Irradiated Seeds by using PSL, TL, ESR and GC/MS (PSL, TL, ESR 및 GC/MS 분석을 통한 감마선 조사된 유지종실류의 검지 특성 연구)

  • Kim, Kyu-Heon;Son, Jin-Hyok;Kang, Yoon-Jung;Park, Hye-Young;Kwak, Ji-Young;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Kim, Jae-I;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.2
    • /
    • pp.130-137
    • /
    • 2013
  • In this study, we investigated the applicability of the photostimulated luminescence (PSL), thermoluminescence (TL), electron spin resonance (ESR) and gas chromatography/mass spectrometry (GC/MS) methods for 5 seeds which are not allowed to be irradiated in Korea. All 5 seeds including evening primrose seed, safflower seed, rape seed, sunflower seed and flax seed were analyzed. Samples were irradiated at 1~10 kGy using a $^{60}Co$ gamma-ray irradiator. In PSL study, the photon counts of all the unirradiated samples showed negative (lower than 700). The photon counts of irradiated (1, 5, 10 kGy) samples showed positive (higher than 5,000). In TL analysis, results showed that it is possible to apply TL method to all foods containing minerals. In ESR measurements, the ESR signal (single-line) intensity of irradiated foods was higher than non-irradiated foods. The hydrocarbons 1,7-hexadecadiene ($C_{16:2}$) and 8-heptadecene ($C_{17:1}$) from oleic acid were detected only in the irradiated samples before and after the treatment at doses ${\geq}$ 1 kGy, but they were not detected in non-irradiated samples before and after treatment. These two hydrocarbons could be used as markers to identify irradiated safflower seed, rape seed, Sunflower seed and flax seed. And then, the hydrocarbons 1,7,10-hexadecatriene ($C_{16:3}$) and 6,9-heptadecadiene ($C_{17:2}$) from linoleic acid were detected in the evening primrose seed, safflower seed and sunflower seed. According to the results, PSL, TL and GC/MS methods were successfully applied to detect the irradiated foods. It is concluded that PSL, TL and GC/MS methods are suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.

Development of an Online Evaluation Model for Traffic Signal Control System (교통신호제어시스템 온라인 평가모형 개발)

  • Go, Gwang-Yong;Lee, Seung-Hwan
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.3
    • /
    • pp.31-40
    • /
    • 2008
  • There have been a lot of efforts to find more accurate evaluation methods for traffic signal control effectiveness for a long period of time. Nowadays a newly advanced method called HILSS, 'Hardware-in-the-Loop-Simulation System', is used to evaluate the overall traffic control's effectiveness including physical control environments like communication conditions, hardware performance, controller's mechanical operations and so on. In this study, an Online-HILSS model has been developed, which runs on CORSIM(5.0) micro traffic simulation model on-lined to COSMOS. For the verification of the model, three tests are performed as follows; (1) a comparison of TMC's timing plan with the simulated green interval, (2) as a case study, a delay distribution comparison of the online simulation with the CORSIM stand-alone simulation. The result of the first test shows that the model can run the simulation green interval by TMC's timing plan correctly. The result of second test shows that the online simulation of the model brings the same simulation results with the CORSIM offline simulation in case of the same timing plan. These results mean that the online evaluation model could be a reliable tool to measure a real-time signal control effectiveness of a wide area street network with the HILSS method.

Analytical Study of Delay Model of Traffic Signal Progression Evaluation on Arterial (간선도로 신호연동화 효율의 평가를 위한 지체도 모형의 해석적 연구)

  • 김영찬;황연하
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.1
    • /
    • pp.131-139
    • /
    • 1999
  • The quality of progression at signalized intersection has the largest potential effect. TRANSYT-7F is widely used to estimate the signal progression delay, but the progress of collecting and executing the compute program appears to be rather cumbersome. The research is to develop the analytical and progressing platoon delay model that is as simple as the methodology of HCM and familiar with the output of simulation model. The general approach to this research was conducted to examine the Rouphail and NCHRP 339 methodology together with the existing progression delay model (TRANSYT-7F. HCM). The scope is contained to be applicable only to cycles with no overflow queue and to obtain a comprehensive evaluation of the effects of changes in the quality of traffic signal progression on stopped delay and to be analyzed a simple mathematical method. The principle assumption for this model is that secondary flows is dispersed and partly mixed with average flow of the primary progressed flow. A second assumption is that through flow is consisted with the part of saturation flow at the front of it and the part of average flow at the rear of it. The delay equations vary for two arrival. The conclusion of this study could be summarized as 1)The evaluation of this model was consistently similar to that of TRANSYT-7F, 2) Platoon pattern has the real traffic flow characteristics. 3) The computing process of progression delay is made to have simple logic and easy calculation by integration, 4) This model could be estimated to be applied in almost all case.

  • PDF

Usability Evaluation and Development of Design Prototyping for MP3 Smart Clothing Product (MP3 스마트웨어 제품 상용화를 위한 디자인 프로토타입 개발 및 사용성 평가 연구)

  • Chea, Heang-Suk;Hong, Ji-Young;Kim, Jun-Hee;Kim, Jin-Hyung;Han, Kwang-Hee;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.10 no.3
    • /
    • pp.331-342
    • /
    • 2007
  • This study focused on developing MP3 smart clothing products and usability evaluation. MP3 smart clothing which was developed in this study contains e-textile keypad and a kit. The kit consists of MP3 Player, remote controller module and ear phone, and are easy to assemble and dismantle. And usability evaluation about MP3 smart Clothing which was developed in this study contains e-textile keypad and a kit. For making the MP3 Smart clothing, e-textile signal line and keypad was developed and a metal connection ring also was manufactured to adhere closely e-textile signal line to keypad. The last products are two kinds of MP3 smart clothing, jacket style of MP3-YSJ(Yonsei Smart Jacket) and safari style of MP3-YSS(Yonsei Smart Safari). Then usability evaluation conducted two times about MP3 smart clothing developed. Usability evaluation is classified by a module evaluation and an item evaluation. The module evaluation measured external appearance, material, a music controller, an ear phone(or a mini speaker) and connector. The item evaluation measured social acceptance, feeling of wearing, utility, easiness of maintenance and safety. The module evaluation described totally positive results in the first usability evaluation about MP3-YSJ 1.0 and MP3-YSS 1.0. The item evaluation shows a lower score in the social acceptance, especially the easiness of connector maintenance and the social acceptance of music-controller in MP3-YSJ 1.0 and MP3-YSS 1.0. The second usability evaluation conducted with improved products by the first usability test results. Results from second item evaluation indicated needs to improve the easiness of connector & music-controller maintenance and the social acceptance of music-controller in MP3-YSJ 2.0. In MP3-YSS 2.0, the easiness of material management and the social acceptance of music controller & connector needed to improvement. In particular, users felt inconvenience in the social acceptance because of e-textile keypad arrangement. To outweigh this disadvantage, further study is needed about keypad interface of the music controller.

  • PDF

Evaluation and Comparison of Signal to Noise Ratio According to Histogram Equalization of Heart Shadow on Chest Image (흉부영상에서 평활화 시 심장저부 음영의 신호 대 잡음비 비교평가)

  • Kim, Ki-Won;Lee, Eul-Kyu;Jeong, Hoi-Woun;Son, Jin-Hyun;Kang, Byung-Sam;Kim, Hyun-Soo;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.197-203
    • /
    • 2017
  • The purpose of this study was to measure signal to noise ratio (SNR) according to change of equalization from region of interest (ROI) of heart shadow in chest image. We examined images of chest image of 87 patients in a University-affiliated hospital, Seoul, Korea. Chest images of each patient were calculated by using ImageJ. We have analysis socio-demographical variables, SNR according to images, 95% confidence according to SNR of difference in a mean of SNR. Differences of SNR among change of equalization were tested by SPSS Statistics21 ANOVA test for there was statistical significance 95%(p < 0.05). In SNR results, with the quality of distributions in the order of original chest image, original chest image heart shadow and equalization chest image, equalization chest image heart shadow(p < 0.001). In conclusion, this study would be that quantitative evaluation of heart shadow on chest image can be used as an adjunct to the histogram equalization chest image.

Evaluation and Comparison of Signal to Noise Ratio According to Change of Kernel size of Heart Shadow on Chest Image (흉부 영상에서 커넬 크기변화에 따르는 신호대잡음비 비교평가)

  • Lee, Eul-Kyu;Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.443-451
    • /
    • 2017
  • The purpose of this study was to comparison of measure signal to noise ratio (SNR) according to change of kernel size from region of interest (ROI) of heart shadow in chest image. We examined images of chest image of 100 patients in a University-affiliated hospital, Seoul, Korea. Chest images of each patient were calculated by using ImageJ. We have analysis socio-demographical variables, SNR according to images, 95% confidence according to SNR of difference in a mean of SNR. Differences of SNR among change of equalization were tested by SPSS Statistics21 ANOVA test for there was statistical significance 95%(p<0.05). In SNR results, with the quality of distributions in the order of kernel size 9*9 image, kernel size 7*7 image and original chest image, kernel size 3*3 image (p<0.001). In conclusion, this study would be that quantitative evaluation of heart shadow on chest image can be used as an adjunct to the kernel size chest image.