SD Methodological Evaluation of the Visual Cognition to the Urban Landscape (SD 기법을 활용한 주거단지의 시지각적 평가)

  • Hwang J.W.;Chai B.S.;Kwon T.K.;Hong C.U.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1918-1920
    • /
    • 2005
  • The color and structure of urban constructions is a factor of urban landscape and shows their characteristics. Hence the modern buildings with their materials and external appearance makes up the urban image. But still yet, it was not easy to evaluate the value of visual landscape of buildings with objective measuring method. Most of all, it depends on the subjective estimation of a few talented or high educated experts with a sense of beauty. In relation to this kind of problems, it was tried here in this study to analyse the human response of brain wave pattern (EEG) with use of SD method, while the tested persons watched the urban landscape constructed in a visual reality. The tested persons were 10 adult males and females with no color blindness and intact cognitive function. Light source with color filter was used for color environment in chamber room. The signal of EEG is analysed digitally and grouped into the $\alpha$ and $\beta$ waves. The result showed that relative power of $\alpha$ wave ratio increased in natural landscape scenary clearly. From these results it was possible to evaluate the human response, which was affected by urban color and structure stimulation and it might be useful as an indicator of visual cognition amenity toward the design of urban construction environment.

  • PDF

A Study on the NC Embedding of Vision System for Tool Breakage Detection (공구파손감지용 비젼시스템의 NC실장에 관한 연구)

  • 이돈진;김선호;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.369-372
    • /
    • 2002
  • In this research, a vision system for detecting tool breakage which is hardly detected by such indirect in-process measurement method as acoustic emission, cutting torque and motor current was developed and embedded into a PC-NC system. The vision system consists of CMOS image sensors, a slit beam laser generator and an image grabber board. Slit beam laser was emitted on the tool surface to separate the tool geometry well from the various obstacles surrounding the tool. An image of tool is captured through two steps of signal processing, that is, median filtering and thresholding and then the tool is estimated normal or broken by use of change of the centroid of the captured image. An air curtain made by the jetting high-pressure air in front of the lens was devised to prevent the vision system from being contaminated by scattered coolant, cutting chips in cutting process. To embed the vision system to a Siemens PC-NC controller 840D NC, an HMI(Human Machine Interface) program was developed under the Windows 95 operating system of MMC103. The developed HMI is placed in a sub window of the main window of 840D and this program can be activated or deactivated either by a soft key on the operating panel or M codes in the NC part program. As the tool breakage is detected, the HMI program emit a command for automatic tool change or send alarm to the NC kernel. Evaluation test in a high speed tapping center showed the developed system was successful in detection of the small-radius tool breakage.

  • PDF

Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor (광전용적맥파 센서를 이용한 맥파전달시간의 측정)

  • Choi, Byeong-Cheol;Jung, Dong-Keun;Jeong, Do-Un;Ro, Jung-Hun;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.383-391
    • /
    • 2004
  • In this study, we implemented the pulse transit time (PTT) system to examine usefulness of the monitoring method of distensibility and elasticity using photoplethysmography sensor in vivo. PTT is defined as the time interval between the peak of QRS complex in ECG signal and the maximum slope point of photoplethysmography. these two signals were converted to digital data by means of AID converter, then PTT was evaluated by heartbeat using PC. Results of analysis were displayed as a graph using spline interpolation method. The variance of PTT was measured repetitiously to verify efficiency of PTT system in resting state and hyperemic state. Repeated measurement of PTT was not same value but showed that coefficients of correlation were related with each other as 0.8302 (P<0.01) in resting state. And also repeated measurement of PTT showed significant correlation as 0.868 (P<0.01) in the hyperemic state. These result showed that PTT is reflect on transient pressure variance in the artery and is very useful method for the evaluation of prognosis of the hypertension and arteriosclerosis.

Detection Probability Evaluation of LEO Satellites based Automatic Identification System for a Maritime-Terrestrial Integrated Network (해상육상통합환경에서 저궤도 위성기반 AIS 시스템의 검출확률 성능평가)

  • Lee, Woo-Young;Choi, Jo-Chun;Lee, Jin-Seok;Lee, Seong-Ro;Lee, Yeon-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.5B
    • /
    • pp.530-538
    • /
    • 2011
  • In this paper, the feasibility of LEO(low earth orbit) satellite-based automatic identification system (SAT-AIS) for the coastal area of the South Korea is evaluated in the context of ship AIS transmission detection probability. We evaluate and compare AIS signal detection probability of ORBCOMM satellites and LEO-one satellites considering link budget, SOTDMA protocol and satellite's swath width. The simulation determines the total number of vessels served by those satellites according to satellite's swath width and thus, By simulation results, the ORBCOMM SAT-AIS system outperforms LEO-one SAT-AIS system. The suggested ORBCOMM based SAT-AIS system can be a solution to resolve the existing limited transmission distance problem of the conventional ship-to-shore AIS system.

Microstructure and Microwave Dielectric Properties of Glass $(La_2O_3-B_2O_3-TiO_2)$/Ceramic Composites ($(La_2O_3-B_2O_3-TiO_2)$ 세라믹 조성에서의 미세 조직 과 마이크로 유전체 특성)

  • Jung, Byung-Hae;Hwang, Seong-Jin;Han, Tae-Hee;Kim, Hyung-Sun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.138-138
    • /
    • 2003
  • Low temperature co-fired ceramic (LTCC) technology offers significant benefits over the other established packaging technologies for high density, high microwave frequency, and fast signal application. Most conventional electroceraramics do not meet the basic requirements in respect of sinterability for LTCC technology. Attention is, therefore, focused on the role of glasses because of the capability they supply with lower sintering temperatures. In this study, commercial ceramic (MBRT-90) in the system BaO-N $d_2$ $O_3$-Ti $O_2$ (BNT: 40 ~ 80 wt%) and L $a_2$ $O_3$- $B_2$ $O_3$-Ti $O_2$ glass (LBT;60 ~ 20 wt%) were prepared. These glass/ceramic composites were evaluated for sintering behavior, phase evaluation, densities, interface reaction, crystallinity, microstructure and microwave dielectric properties. It was found that the addition LBT glass frits significantly lowered the sintering temperature to below 90$0^{\circ}C$ and as temperature increased (750~90$0^{\circ}C$) densification developed dynamically which was meant to be as over 95% of relative density. It is supposed that in the microstructure, the grain size was increased accompanying with the formation of different phases such as LaB $O_3$ and Ti $O_2$ under the condition of increasing sintering temperature. The sintered bodies represented applicable dielectric properties, namely 20 ~ 40 for $\varepsilon_{{\gamma}}$, ~ 10000 GHz for Q* $f_{0}$ and 10~80 ppm/$^{\circ}C$ for $\tau$$_{f}$. The results suggest that the composite is one of feasible candidates for the microwave use in LTCC technology.y.e use in LTCC technology.y.

  • PDF

Standard Field Generation Using a Micro-TEM Cell and Its Measurement Uncertainty Evaluation (Micro-TEM Cell을 사용한 표준 전자기장의 발생 및 측정불확도 평가)

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Kang, Ung-Taek;Kang, No-Weon;Kang, Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.91-99
    • /
    • 2009
  • In this paper, a standard field generation method using a micro-TEM ceil is described and its measurement uncertainty is evaluated. The standard field generation system consists of an auto-leveling signal source, a micro-TEM cell operating up to 1.2 GHz, and a power measuring Instrument using a thermistor mount. Measurement results of a field strength key comparison (CCEM.RF-K20) for the field strength of 20 V/m at frequencies between 10 MHz and 1 GHz are presented for validating the standard field generation method.

Noise Cancellation using Microphone Array in Digital Hearing Aids (디지털 보청기에서 마이크로폰 어레이를 이용한 잡음제거)

  • Bang, Dong-Hyeouck;Kil, Se-Kee;Kang, Hyun-Deok;Yoon, Gwang-Sub;Lee, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.857-866
    • /
    • 2009
  • In this paper, a noise cancellation-method using microphone array for digital hearing aids is proposed. The microphone array is located around the ear of a dummy. Speech sound is generated from the forward speaker positioned in the front of the dummy and noise sound is generated from the backward speaker. The speech and noise are mixed in the air space and entered into the microphones. VAD(voice activity detector) and ANC(adaptive noise cancellation) methods were used to eliminate noise in the sound of the microphones. 10 two-syllable words and 4 sentences were used for speech signals. Babble and car interior noise were used for noise signals. The performance of the proposed algorithm was evaluated by SNR(signal-to-noise ratio) and PESQ-MOS(perceptual evaluation of speech quality-mean opinion score). In babble noise condition, SNR was improved as much as $7.963{\pm}1.3620dB\;and\;3.968{\pm}0.6659dB$ for words and sentences respectively. In the case of car interior noise, SNR was improved as $10.512{\pm}2.0665dB\;and\;6.000{\pm}1.7642dB$ for words and sentences respectively. PESQ-MOS of the babble noise was improved as much as $0.1722{\pm}0.0861$ score for words and $0.083{\pm}0.0417$ score for sentences. And PESQ-MOS of the car interior noise was improved as $0.2661{\pm}0.0335$ score and $0.040{\pm}0.0201$ score for words and sentences respectively. It is verified that the proposed algorithm has a good performance in noise cancellation of microphone array for digital hearing aids.

An Evaluation of Operator Performance Related to the Switch Types in Man Control Rooms of the Nuclear Power Plants (주관적 작업부하 평가기법을 이용한 원자력 발전소 주제어반 제어 스위치 사용 인적 수행도 평가)

  • Byun, Seung-Nam
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.1
    • /
    • pp.54-65
    • /
    • 2000
  • The objective of this study is to evaluate the operator performance relating to hand switches with two or three buttons in the main control rooms of nuclear power plants. Based on the comparative analysis of the nuclear power plants, two different subjective workload-rating scales were used to evaluate the performance of 48 operators: the Overall Workload(OW) and National Aeronautics and Space Administration Task Load Index (NASA TLX). The survey questions consisting of the eight-items were asked to evaluate the operating experiences for the two different switch types. The OW scales ratings were applied to measure the workload of the switch-related tasks. The ratings revealed that signal detection tasks caused less workload in the three-buttoned-switch operators than the other switch group. However, in the switch operation tasks, the switch types did not show statistically significant effects on workload level. The NASA TLX scale ratings were performed based on detailed task scenarios that assumed the accident of small break loss of coolant, what we call, the small LOCH. The NASA TLX was administered to three different task groups: the reactor, the turbine, and the electric operator groups. Based on the NASA TLX, the two-buttoned switch groups showed higher workload than those with the three-buttoned switches. However, a statistically significant difference was found only in the reactor operator groups. When the current switch type was assumed to be changed for the other type, all of the three-buttoned switch groups were predicted to have higher workload than the other switch groups, respectively. The implications of these findings were discussed.

  • PDF

Performance Evaluation of Time Hopping Binary PPM Impulse Radio System for Indoor Multiple Access Communication (실내 다원접속 통신을 위한 TH Binary PPM IR 시스템의 성능 평가)

  • 이양선;강희조
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.7
    • /
    • pp.1032-1037
    • /
    • 2002
  • In this paper, derived monocycle pulse that application is possible within permission frequency band (3.1 ~ 10.6GHz) that establish in FCC. Also, PPM modulated TH IR system simulator is designed in AWGN environment. It is analyzed monocycle pulse specific property and system performance using simulator. Also, analyzed BER performances of IR system in multiple access interference environment using proposed parameters. According to result, application of possible pulse duration$(t_n)$ is very limited by 0.04~0.0326 ns in permission frequency range that establish in FCC. In the case of same pulse signal power, we could know that system performance changes by $N_s$ regardless of pulse duration. IR system that need high speed transmission more than 50 Mbps in multiple access interference environment could know that very serious performance decrease by multiple access Interference happens.

Acoustic Transfer Characteristics of Ship′s Bridge for Whistle Sound (기적음에 대한 선박 선교의 음향전달특성)

  • Yim, Jeong-Bin;Kim, Chang-Kyoung
    • Journal of Navigation and Port Research
    • /
    • v.28 no.6
    • /
    • pp.491-496
    • /
    • 2004
  • The paper describes measurement techniques for an acoustic transfer characteristic of ship's bridge stimulated by a whistle sound The response sounds, according to the opening-shutting conditions of bridge doors for Training Ship ‘SAENURI’, are measured by B&K 2260D equipment, and then the frequency responses are extracted by B&K 7830 software. To evaluate the measured transfer characteristic, the 128th order FIR (Finite Impulse Response) filters, containing the different frequency characteristics, are constructed based on the frequency sampling-based design method Using evaluation indexes with six scales, psychological assessments by five subjects are carried out with test sounds which are obtained from convolving the source signal with FIR filters. As results of tests, the test sounds gives $A_S$ 3.3∼4.7 which means the psychological sense of ‘it is almost similar sound as original ones in a real world’, and thus it is clearly seen that the proposed method can be used for the measurement of an acoustic transfer characteristic of ship’s bridge.