• Title/Summary/Keyword: Signal Equipment

Search Result 966, Processing Time 0.03 seconds

Analysis on the Performance Degradations of Chung-Ju DGPS Reference Station by Radio Environment (전파환경에 의한 DGPS 충주 기준국의 성능저하 분석)

  • Park, SulGee;Han, YoungHoon;Park, SangHyun;Choi, YongKwon;Lee, Sang Jeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.9
    • /
    • pp.1822-1829
    • /
    • 2016
  • DGPS Reference station is established in Korea for improvement of GPS navigation accuracy and needs of integrity. Recently, DGPS stations provide user positioning information on land as well as ocean. However, this paper investigated visibility and interference environment for performance degradation of Chung-ju DGPS reference station. In case of Young-do reference station, visibility and interference environment were satisfied with reference standard. In case of Chung-ju reference station, visibility was satisfied with 7 degree elevation angle. However, interference environment was not satisfied with reference standard of -50dBm. This paper proposed time differential measurement analysis method excluding error of signal noise for analyzing measurement error. Chung-ju reference station measurement analysis result is three times the error than on Young-do in Dec, 2015. In addition, this paper has confirmed measurement performance degradations because of reference station equipment problem. Future study will be carried out performance analysis of 17 DGPS reference station.

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.

Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현)

  • Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.678-681
    • /
    • 2003
  • In this paper, we aims to develop a microcontroll er-based portable pulse oximeter using Compact Flash Interface. First, portable pulse oxineter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of SpO$_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patients condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO$_2$ modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact flash interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

Effect of Major Factors on the Spray Characteristics of Ultrasonic Atomizing Nozzle (초음파 미립화 노즐의 분무 특성에 미치는 주요 인자의 영향)

  • Jeong, Seon Yong;Lee, Kye Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.1-7
    • /
    • 2017
  • The atomization of a liquid into multiple droplets has many important industrial applications, including the atomization of fuels in combustion processes and coating of surfaces and particles. Ultrasonic atomizing nozzle has a transducer that receives electrical input in the form of a high frequency signal from a power generator and converts that into mechanical energy at the same frequency. Liquid is atomized into a fine mist spray using high frequency sound vibrations. In coating applications, the unpressurized, low-velocity spray reduces the amount of overspray significantly because the droplets tend to settle on the substrate, rather than bouncing off it. The spray can be controlled and shaped precisely by entraining the slow-moving spray in an ancillary air stream using specialized types of spray-shaping equipment. The desired patterns of spray can be obtained using an air stream. To simulate the water mist behavior of an ultrasonic atomizing nozzle using an air stream, the Lagrangian dispersed phase model was employed using the commercial code FLUENT. The effects of the nozzle contraction shape, water droplet size and the pneumatic pressure drop on the spray characteristics were investigated to obtain the optimal condition for coating applications.

Usefulness of the PRESS Technique using 3.0T Magnetic Resonance Spectroscopy for Evaluation of Non-Alcoholic Fatty Liver Disease Patients (비알콜성 지방간환자 평가를 위한 3.0T 고자기장 자기공명분광법을 이용한 PRESS 기법의 유용성)

  • Goo, Eun-Hoe
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5931-5936
    • /
    • 2012
  • This study was to evaluate the clinical usefulness of the PRESS technique based on the correlation between PRESS technique and biopsy results by applying 3.0T high magnetic field MRS technique for evaluation of non-alcoholic fatty liver disease patients. This experiment were carried out using a 3.0T magnetic resonance imaging equipment. The part data of each spectrum is taken by peak area integration. The part data of resonance peak was used to calculate relative ratio. MR spectral peak in patients with non-alcoholic fatty liver disease is from 0.9 to 1.6 ppm. According to MRS method study result, Patients with NAFLD were obtained with 94% sensitivity and 80% specificity(p=0.000). When compared to normal based on MRS and Biopsy results was valid correlation(r=0.79, p=0.04). Results for NAFLD(r=0.89, p=0.002) also showed a correlation. Therefore, PRESS technique to evaluate patients with non-alcoholic fatty liver disease, the distribution difference between normal liver and fatty liver part is significantly distinguished. Biopsy and MRS fatty liver peak ratio(%) proves high lipid over grade(r = 0.7).

Simulation Methods Development for a Plant Unit Master Control Logic Using Simulink in MATLAB (매트랩 시뮬링크를 이용한 플랜트 유닛마스터 제어로직 시뮬레이션 기법 개발)

  • Yoon, Changsun;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.324-334
    • /
    • 2017
  • The simulators for a plant unit master control (UMC) developed by domestic or overseas researchers have been developed for operator-training purposes. UMC simulators normally constructed at the end of the plant construction, despite the UMC logics, should be simulated to pre-check many signal interfaces within the power generation systems. Because of the differences in construction schedule, it is difficult for logic designers or commissioning engineers to simulate the UMC logic during the design or commissioning stage. In this background, this paper proposes a simulation method that can be used easily by plant logic designers or operators in the MATLAB Simulink programming environment. The core of the UMC is realized with a unique simulation algorithm based on mathematical analysis and functional blocks combination. In addition, an integer-based configuration was proposed to realize the plant target value control for the equipment in the logic. With these simulation methods, functions, e.g., load distribution, high-low limitations, frequency compensation, etc. were simulated. The results showed that the plant UMC logic can be simulated in Simulink without a plant simulator. The various functions proposed in this paper can provide useful information about Simulink-based simulation design for plant logic designers or commissioning engineers during the power plant construction period.

Derivation and verification of electrical resistivity theory for surrounding ground condition prediction of TBM (TBM 주변 지반상태예측을 위한 전기비저항 이론식 유도 및 검증)

  • Hong, Chang-Ho;Lee, Minhyeong;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.1
    • /
    • pp.135-144
    • /
    • 2020
  • Since the depth of tunneling with tunnel boring machine (TBM) becomes deeper and deeper, the expense for site investigation for coring and geophysical survey increases to obtain the sufficient accuracy. The tunnel ahead prediction methods have been introduced to overcome this limitation in the stage of site investigation. Probe drilling can obtain the core and borehole images from a borehole. However, the space in TBM for the probe drilling equipment is restricted and the core from probe drilling cannot reflect the whole tunnel face. Seismic methods such as tunnel seismic prediction (TSP) can forecast over 100 m ahead from the tunnel face though the signal is usually generated using the explosive which can affect the stability of segments and backfill grout. Electromagnetic methods such as tunnel electrical resistivity prospecting system (TEPS) offer the exact prediction for a conductive zone such as water-bearing zone. However, the number of electrodes installed for exploration is limited in small diameter TBM and finally the reduction of prediction ranges. In this study, the theoretical equations for the electrical resistivity survey whose electrodes are installed in the face and side of TBM to minimize the installed electrodes on face. The experimental tests were conducted to verify the derived equations.

Preliminary evaluation of new 68Ga-labeled cyclic RGD peptides by PET imaging

  • Shin, Un Chol;Jung, Ki-Hye;Lee, Ji Woong;Lee, Kyo Chul;Lee, Yong Jin;Park, Ji-Ae;Kim, Jung Young;Kang, Joo Hyun;An, Gwang Il;Ryu, Young Hoon;Choi, Jae Yong;Kim, Kyeong Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.2
    • /
    • pp.118-122
    • /
    • 2016
  • Integrin ${\alpha}_v{\beta}_3$ plays an important role in the tumor metastases and angiogenesis. Arginine-glycine-aspartate (RGD) peptide motif binds to the integrin ${\alpha}_v{\beta}_3$. General $^{68}Ga$-labeled cyclic RGD peptides was rapidly eliminated from the circulatory system by renal excretion because of its hydrophilic property. The purpose of this study was to develop a novel $^{68}Ga$-labeled cyclic RGD peptides, which could acquire enhanced PET tumor images with improved pharmacokinetics by adopting biphenyl group between chelator and RGD peptides. $^{68}Ga$-DOTA-2P-c(RGDyK) was demonstrated a 12% higher lipophilicity level than $^{68}Ga$-DOTA-c(RGDyK) as a reference compound. In the animal PET, $^{68}Ga$-DOTA-2P-c(RGDyK) represented relatively lower blood-clearance, and an increased signal to noise ratio compared to $^{68}Ga$-DOTA-c(RGDyK). From these perspective, $^{68}Ga$-DOTA-2P-c(RGDyK) could be a good candidate for in integrin ${\alpha}_v{\beta}_3$-expressed tumor imaging.

Implementation of a Ranging Simulator for the ATM-PON Based on ITU-T G.983.1 (G.983.1 기반의 ATM-PON을 위한 Ranging 시뮬레이터 구현)

  • Hong, Jae-Geun;Woo, Man-Sik;Chung, Hae;Kim, Jin-Hee;Yoo, Gun-Il;Kim, Woon-Ha
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.9
    • /
    • pp.12-20
    • /
    • 2001
  • The ATM-PON has an important meaning at next generation access network because the equipment transmits various types of user traffic with a single platform through the passive optical splitter. Ranging is a technology to place all ONUs at the same virtual distance in order to provide the synchronization for the upstream signal in the ATM-PON based on the Time Division Multiplexing (TDM). In this paper, we review the merits of ATM PON and related protocol for the PON operation. We summarize and analyze the steps about the ranging protocol based on ITU-T G.983.1 and implement a simulator that can simulate the ranging procedure based on our modeling. In this paper, we can investigate time requirements of G.983.1 by using the simulator and find out the wasted rate of the bandwidth during the ranging procedure in order to know the influence for ONUs while ATM-PON is in-service. Also, we show that a new ranging scheme reducing window size can avoid the degradation of quality of service of ONUs in service with simulation.

  • PDF

Standard Configuration for Interface of the Traffic Information Service using DSRC (DSRC를 이용한 교통정보서비스 인터페이스 표준 구성)

  • Kim, Kyoung-Hwan;Cho, Yung-Sung;Bae, Myoung-Hwan;Kim, Sang-Heon;Lee, Kyeong-Im
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.5
    • /
    • pp.1-13
    • /
    • 2011
  • Recently, a number of OBU(On Board Unit) have being spreaded since ETCS(Electronic Toll Collection System)using DSRC(Dedicated Short Range Communication) was installed in the tollgate of the whole country. Many R&D and commercialization related to ITS service using DSRC and OBU mentioned above are ongoing such as traffic information collection and provision and a signal control, and public traffic information and management and so on. Especially, there are many researches conducted(conducting) on traffic information collection and provision using communication between OBU and RSE. However, Standards for both DSRC application and traffic collection and provision are not established clearly yet. So we would like to suggest a method of traffic information collection and provision without changing of standard related to DSRC. This method is to put the traffic messages into the existing Action primitive for ETC, which is described on "Technical criterion IV of basic traffic information exchange" which was notified by Ministry of Land, Transport and Maritime Affairs. Proposed standard application method is applied both to RSE and OBE. It is the same system which ETCS used in highway, currently. We confirmed the efficiency and performance of the system through conducting a variety of driving test using 4 vehicles in real road condition. Result of the real road test shows the effectiveness and validity of this method with about 97% communication success rate and based on studying the cases of 3% communication failure, we can analyse the expected problems in traffic information collection and provision using this method.