• Title/Summary/Keyword: Signal Detector

Search Result 997, Processing Time 0.029 seconds

Time-encoded Near-infrared (NIR) Spectroscopic Comparison of Absorbance Measurement Using an Acousto-optic NIR Swept Laser Source (음향광학 파장선택 필터 기반 파장훑음 레이저를 이용한 시간-인코딩 된 근적외선 흡광도 측정 비교 연구)

  • Jang, Hansol;Kim, Gyeong Hun;Han, Ga-Hee;Cho, Jaedu;Kim, Chang-Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • Time-encoded near-infrared spectroscopy (NIRS) system is proposed, based on a near-infrared (NIR) swept laser source, for comparison to the conventional NIRS method using a detector-type spectrometer. The cavity of the NIR swept laser source consists of a semiconductor optical amplifier (SOA) with a gain region around 800 nm, and several fiber-optic components. To change the output wavelength in time using an applied electric radio-frequency signal, an acousto-optic tunable filter (AOTF) is introduced in the fiber ring cavity configuration. To demonstrate the feasibility of an NIR swept laser source for NIRS imaging, the spectroscopic comparison of two kinds of absorbance-measuring systems a detector-type spectrometer using a white light source, and a source-type spectrometer using an NIR swept laser is successfully performed with an NIR-absorbing dye.

Feasibility of Optoelectronic Neural Stimulation Shown in Sciatic Nerve of Rats (흰쥐의 좌골 신경 자극을 통한 광전 자극의 가능성에 대한 연구)

  • Kim Eui tae;Oh Seung jae;Baac Hyoung won;Kim Sung june
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.611-615
    • /
    • 2004
  • A neural prostheses can be designed to permit stimulation of specific sites in the nervous system to restore their functions, lost due to disease or trauma. This study focuses on the feasibility of optoelecronic stimulation into nervous system. Optoelectronic stimulation supplies, power and signal into the implanted optical detector inside the body by optics. It can be effective strategy especially on the retinal prosthesis, because it enables the non-invasive connection between the external source and internal detector through natural optical window 'eye'. Therefore, we designed an effective neural stimulating setup by optically based stimulation. Stimulating on the sciatic nerve of a rat with proper depth probe through optical stimulation needs higher ratio of current spreading through the neural surface, because of high impedance of neural interface. To increase the insertion current spreading into the neuron, we used a parallel low resistance compared to load resistance organic interface and calculated the optimized outer parallel resistance for maximum insertion current with the assumption of limited current by photodiode. Optimized outer parallel resistance was at a range of 500Ω-700Ω and a current was at a level between 580uA and 650uA. Stimulating current efficiency from initial photodiode induced current was between 47.5 and 59.7%. Various amplitude and frequency of the optical stimulation on the sciatic nerve showed the reliable visual tremble, and the action potential was also recorded near the stimulating area. These result demonstrate that optoelectronic stimulation with no bias can be applied to the retinal prosthesis and other neuroprosthetic area.

The fabrication and evaluation of CdS sensor for diagnostic x-ray detector application (진단 X선 검출기 적용을 위한 CdS 센서 제작 및 성능 평가)

  • Park, Ji-Koon;Lee, Mi-Hyun;Choi, Young-Zoon;Jung, Bong-Zae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Recently, various semiconductor compounds as radiation detection material have been researched for a diagnostic x-ray detector application. In this paper, we have fabricated the CdS detecton sensor that has good photosensitivity and high x-ray absorption efficiency among other semiconductor compounds, and evaluated the application feasibility by investigating the detection properties about energy range of diagnostic x-ray generator. We have fabricated the line voltage selector(LCV) for a signal acquisition and quantities of CdS sensor, and designed the voltage detection circuit and rectifying circuit. Also, we have used a relative relation algorithm according to x-ray exposure condition, and fabricated the interface board with DAC controller. Performance evaluation was investigated by data processing using ANOVA program from voltage profile characteristics according to resistive change obtained by a tube voltage, tube current, and exposure time that is a exposure condition of x-ray generator. From experimental results, an error rates were reduced according to increasing of a tube voltage and tube current, and a good properties of 6%(at 90 kVp) and 0.4%(at 320 mA) ere showed. and coefficient of determination was 0.98 with relative relation of 1:1. The error rate according to x-ray exposure time showed exponential reduction because of delayed response velocity of CdS material, and the error rate has 2.3% at 320 msec. Finally, the error rate according to x-ray dose is below 10%, and a high relative relation was showed with coefficient of determination of 0.9898.

DIGITAL IMAGE PROCESSING AND CLINICAL APPLICATION OF VIDEODENSITOMETER (실험적으로 제작한 Videodensitometer의 디지털 영상처리와 임상적 적용에 관한 연구)

  • Park Kwan-Soo;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.273-282
    • /
    • 1992
  • The purpose of this study was to propose the utility which was evaluated the digital image processing and clinical application of the videodensitomery. The experiments were performed with IBM-PC/16bit-AT compatible, video camera(CCdtr55, Sony Co., Japan), an color monitor(MultiSync 3D, NEC, Japan) providing the resolution of 512×480 and 64 levels of gray. Sylvia Image Capture Board for the ADC(analog to digital converter) was used, composed of digitized image from digital signal and the radiographic density was measured by 256 level of gray. The periapical radiograph(Ektaspeed EP-21, Kodak Co., U. S. A) which was radiographed dried human mandible by exposure condition of 70 kVp and 48 impulses, was used for primary X-ray detector. And them evaluated for digitzed image by low and high pass filtering, correlations between aluminum equivalent values and the thickness of aluminum step wedge, aluminum equivalent values of sound enamel, dentin, and alveolar bone, the range of diffuse density for gray level ranging from 0 to 255. The obtained results were as follows: 1. The edge between aluminum steps of digitized image were somewhat blurred by low pass filtering, but edge enhancement could be resulted by high pass filtering. Expecially, edge enhancement between distal root of lower left 2nd molar and alveolar lamina dura was observed. 2. The correlation between aluminum equivalent values and the thickness of aluminum step wedge was intimated, yielding the coefficient of correlation r=0.9997(p<0.00l), the regression line was described by Y=0.9699X+0.456, and coefficient of variation amounting to 1.5%. 3. The aluminum equivalent values of sound enamel, dentin, and alvolar bone were 15.41㎜, 12.48㎜, 10.35㎜, respectively. 4. The range of diffuse density for gray level ranging from 0 to 255 was wider enough than that of photodenstiometer to be within the range of 1-4.9.

  • PDF

A Study on the Phase-looked Dielectric Resonator Oscillator using Bias Tuning (바이어스 동조를 이용한 위상 고정 유전체 공진 발진기에 관한 연구)

  • 류근관;이두한;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.10
    • /
    • pp.1982-1990
    • /
    • 1994
  • We implemented a PLDRO(Phase Locked Dielectric Resonator Oscillator) using the concept of the feedback property of PLL(Phase Locked Loop) for Ku-band(10.95-11.70 GHz). The conventional approaches to a PLDRO design use varactor diode tuning method.. But in theis paper, the PLDRO has the advantage of the frequency sensitivity to changes in the supple voltage of the oscillating device without the frequency-variable part by varactor diode voltage-control. and uses a SPD(Sampling Phase Detector) for phase-comparision. The PLDRO is composed of the DRO phase-locked to the reference signal of UHF band by using a SPD for high frequency stability and can be available for European FSS(Fixed Satellite Service) at 10.00GHz. The PLDRO generates the output power of 8.67 dBm at 10.00 GHz and has a phase noise of -81 dBc/Hz at 10 kHz offset from carrier. The hamonic and spurious characteristics have -42.33 dBc and -65dBc respectively. This PLDRO has much better frequency stability, lower phase noise, and more economical effect for a satellite system than conventional DRO.

  • PDF

Signal Detection for 8 PSK and 16 QAM in EST-Based Modulation (EST기반 변조에서 8 PSK와 16 QAM 에 대한 신호 검출)

  • Kwon, Byung-Uk;Hwang, Tea-Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.11C
    • /
    • pp.682-693
    • /
    • 2011
  • Energy spreading transform (EST) based modulation is an effective technique to combat frequency-selective fading in broadband wireless communication. It performs close to the inter-symbol interference (ISI)-free matched filter bound (MFB) only at the complexity of a linear detector. Originally, EST-based modulation has been proposed for QPSK. However, to fully utilize the capacity of multipath fading channels, higher-order modulations are also necessary. In this paper, we review the EST based modulation that has originally been proposed for QPSK and discuss its extension to 8 PSK and 16 QAM. The performance of the extended system is verified through simulation in Proakis B and 8-tap fading channel. The EST based modulation for 8 PSK shows the performance which is very close to MFB and the EST based modulation for 16 QAM shows the performance gap between its receiver and MFB.

Design and Fabrication of Ka-Band Active PIN Diode Limiter for a Millimeter Wave Seeker (밀리미터파 탐색기용 Ka 대역 능동 PIN 다이오드 리미터 설계 및 제작)

  • Yang, Seong-Sik;Lim, Ju-Hyun;Na, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.220-228
    • /
    • 2012
  • In this paper, we explained the design technique about Ka-band active limiter for protecting the receiver of a millimeter wave seeker. To implement low flat leakage power, we proposed the control circuit of active limiter to control limiter voltage with PRF(Pulse Repetition Frequency) signal and input power. This active limiter consisted of the conventional 2 stage passive limiter, a feedback circuit with a directional coupler, detector, non-inverting amplifier and over-current protection resistance. As the test result of the fabricated Ka-band limiter, it had 1 GHz bandwidth, 3.5 dB insertion loss at the small input power and -7.5 dBm flat leakage at the 4 W RF input power, respectively.

A Study On Development of Fast Image Detector System (고속 영상 검지기 시스템 개발에 관한 연구)

  • Kim Byung Chul;Ha Dong Mun;Kim Yong Deak
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.1
    • /
    • pp.25-32
    • /
    • 2004
  • Nowadays image processing is very useful for some field of traffic applications. The one reason is we can construct the system in a low price, the other is the improvement of hardware processing power, it can be more fast to processing the data. In traffic field, the development of image using system is interesting issue. Because it has the advantage of price of installation and it does not obstruct traffic during the installation. In this study, 1 propose the traffic monitoring system that implement on the embedded system environment. The whole system consists of two main part, one is host controller board, the other is image processing board. The part of host controller board take charge of control the total system interface of external environment, and OSD(On screen display). The part of image processing board takes charge of image input and output using video encoder and decoder, Image classification and memory control of using FPGA, control of mouse signal. And finally, for stable operation of host controller board, uC/OS-II operating system is ported on the board.

Fast LFM Target Detection Method with Robustness for Doppler Shift in Narrow-Band Sonar Systems (협대역 소나시스템에서 도플러 천이에 강인한 고속 LFM 표적 검출기법)

  • Choi, Sang-Moon;Do, Dae-Won;Kim, Woo-Sik;Lee, Dong-Hun;Kim, Hyung-Moon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.114-125
    • /
    • 2014
  • In a conventional sonar system, which uses LFM signal for detecting targets with varying speed, the results of multiple LFM Doppler correlators are aligned and the maximum alined result are selected as a test cell for detecting targets. As the number of the LFM Doppler correlators are increased for accurate target detection, as the required computational complexity and the memory are also increased. This fact makes it difficult to implement the accurate LFM target detector. In this paper, we propose a new fast target detection which is robust for the variation of target speed. Because the proposed method uses the summation of alined results of large numbers of LFM Doppler correlators, the proposed method increase SNR and provide robust SNR for the variation of target speed. And the proposed method can provide very fast target detection by implementing the process, the summation of alined results of large numbers of LFM Doppler correlators, as one summation filter.

Visible Light Wireless Communication Link Using LEDs (LED를 이용한 가시광 무선 통신 링크)

  • Son, Yong-Hwan;An, Sung-Chan;Kim, Hyun-Seung;Won, Yong-Yuk;Han, Sang-Kook
    • Journal of IKEEE
    • /
    • v.13 no.4
    • /
    • pp.70-74
    • /
    • 2009
  • In this paper, We propose the visible light communication(VLC) link based on white light emitting diode (LED) and Photo detector(PD). The proposed architecture is demonstrated experimentally and its performance is verified through the experimental results of quality-factor(Q-factor) and eye pattern of 10Mb/s PRBS signal. The ambient light effect from a typical type fluorescent lamp source was also analyzed. when the distance between the LED and the PD is about 1m, error free wireless transmission of the LED was achieved up to 10Mb/s data rate. Under the condition with ambient light, low BER, data transmission of the VLC link is achieved up to 5Mb/s data rate at 1m. Also, when the PD is placed away from the center, low BER data transmission of the VLC link is achieved up to 1Mb/s at 10cm and 10Mb/s at 5cm.

  • PDF