• Title/Summary/Keyword: Siemens

Search Result 382, Processing Time 0.035 seconds

PERFORMANCE EVALUATION OF FUZZY CONTROL THROUGH AN INTERNATIONAL BENCHMARK

  • Boverie, Serge;Demaya, Bemard;Lequellec, Jean-Michel;Titli, Andre
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.941-944
    • /
    • 1993
  • In this paper, we present an international benchmark used in the adaptive control specialist community in order to evaluated the fuzzy control performances. Before solving the corresponding problems, we introduce some improvements on a classic fuzzy controller in order to consider high order systems and time delays. At the end of this paper, the simulation results obtained with the extended Fuzzy Controller will be compared with those obtained with a Supervised Adaptive Controller.

  • PDF

Preliminary Study of the Siemens Primus Linac MLC modelling using BEAM Monte Carlo code (BEAM 몬테칼로 코드를 이용한 Siemens Primus 선형가속기 다엽콜리메이터의 모델링 예비연구)

  • Cheong, Kwang-Ho;Suh, Tae-Suk;Cho, Byung-Chul;Park, Sung-Ho
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.29-32
    • /
    • 2004
  • In this study, we had modelled Siemens type MLC using BEAM Monte Carlo code and tested the feasibility of the modelling. To model the Primus linac MLC, we had measured the actual dimensions of MLC and each leaves, then approximated the leaf shape. VARMLC component module was used for the modelling and leakage, tongue-and-groove effect were also considered. Simulation result showed the good agreement with the film measurement.

  • PDF

Implementation of Performance Monitoring System for Thermal Power Plant in SIEMENS DCS (SIEMENS DCS 환경에서 화력발전소 성능감시 시스템 구현)

  • 김승민;문태선;조창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.37-37
    • /
    • 2000
  • This paper introduces the Performance Monitoring System(PMS) in a thermal power plant. The purpose of the PMS is to offer the operator current performance information of plant which could be an index of plant status or information to improve plant efficiency. The PMS of Bukcheju thermal power plant unit #2&3 is implemented under the SIEMENS DCS which supplies about 150 function blocks for performance calculation and all measured signals. The performance of unit, boiler, turbines, feedwater heaters, condenser, airpreheaters, feedwater pumps will be monitored and updated for every 5 minutes in PMS of Bukcheju TPP.

  • PDF

Electromagnetic effect by ignition current in vehicle (차량에서 Ignition current 변화에 따른 자기 유도에 의한 센서 출력 변화)

  • Lee, Dong-Ju;Kim, Cheol;Choe, Jang-Hyeon;Seong, Eun-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1611-1612
    • /
    • 2006
  • We are using the Faraday's electromagnetic law so as to improve our life in various industry fields. However, the side effect of the Faraday's law can be occurredin the sensors of the vehicle due to the high current flow such as Ignition. This effect is mainly caused by the shape of the wiring harness between sensor and high current load in the vehicle. To minimize the side effect by Faraday's law, three methods shall be considered in this paper (1) Pin definition of the sensor, (2) Pin definition of the high current load, (3) Wiring harness shape.

  • PDF

The ξ-Quality Defuzzification Method

  • Hans, Hellendoorn;Christoph, Thomas
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1159-1162
    • /
    • 1993
  • We describe six important defuzzification methods and their respective merits and shortcomings, dependent on the rules, domains, etc. Furthermore, we present an alternative approach, the so called ξ-Quality defuzzification method, for the case that the output fuzzy sets have different shape or are asymmetric.

  • PDF