• Title/Summary/Keyword: Side step

Search Result 575, Processing Time 0.029 seconds

Effect of an Arm Sling on Gait with Hemiparesis (팔걸이가 편마비환자의 보행에 미치는 영향)

  • Song, Geun-Ho;Lee, Hyun-Ok
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.4
    • /
    • pp.27-40
    • /
    • 2006
  • Purpose: This study was to investigate the effect of an arm sling on gait with hemiparesis. Methods: Fifteen patients(8 male, 7 female) with hemiparesis participated in this study and walked self-selected speed over 10m walkway, randomly without arm sling, with Single strap hemisling and Rolyan humeral cuff sling. It were filmed by 5 video camera and used with 3-dimensional motion analyzer system. The following gait variables were analyzed: temporo-spatial parameters, kinematic parameters. Results: In the comparison of temporo-spatial parameters each trial, walking velocity and single support time on affected side was significantly increased and step length on affected side, step length asymmetry ratio, single support time asymmetry ratio was significantly decreased in the Single strap hemisling and Rolyan humeral cuff sling. In the comparison of kinematic parameters each trial, maximal angle of the hip flexion on affected side was significantly increased in the Single strap hemisling and Rolyan humeral cuff sling and maximal angle of the knee flexion on affected side was significantly increased in the Rolyan humeral cuff sling and maximal angle of the ankle dorsiflexion on affected side was significantly increased in the Single strap hemisling. Conclusion: An arm sling improved walking velocity and decreased asymmetry and increased maximal angle of hip, knee, ankle flexion on affected side with hemiparesis caused by stroke.

  • PDF

The Effect of Resistance Exercise Using Elastic Band on Muscle Strength, Muscle Tone, Balance and Gait in Stroke Patients (탄성밴드를 이용한 저항운동이 뇌졸중 환자의 근력, 근긴장도, 균형 및 보행에 미치는 영향)

  • An, Soyeong;Kang, Soonhee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.57-66
    • /
    • 2020
  • Purpose : This study aimed to identify whether resistance exercise using elastic bands for six weeks can improve muscle strength, muscle tone, balance, and gait in patients with stroke. Methods : In total, 35 patients with stroke were randomly divided into three groups: resistance exercise using elastic band training combined with less affected side training group, more affected side training group, and both sides training group. Muscle strength, muscle tone, balance, and gait were assessed using a hand-held dynamometer, the modified Ashworth scale, the Berg Balance scale (BBS), and wireless 3-axis accelerometer, before and after training. Results : All three groups showed a significant increase in muscle strength of the lower extremity after training, and there was a significant difference among the groups. There was no change in muscle tone in all three groups. BBS scores increased significantly in all three groups after training, but these scores were not significantly different. The gait speed increased significantly in all three groups after the training, but the difference was not significant. The cadence increased significantly in Group 2 after training; however, there was no significant difference between Groups 1 and 3. There were no significant differences between the groups before and after the training. Step length increased significantly in Groups 2 and 3 after the training, but it was not significantly different in Group 1. After training, Groups 2 and 3 were significantly greater than Group 1 in the change in step length. Conclusion : The results show that resistance exercise using elastic bands can improve strength, balance, and gait in patients with chronic stroke. Especially, more affected side training was more effective in improving muscle strength than less affected side training. More affected side and both sides training are thought to be more effective than less affected side training to improve step length.

The Influence of Auditory-Feedback Device Using Wearable Air-Pressure Insole on Spatiotemporal Gait Symmetry in Chronic Hemplegia

  • Heo, Ji-Hun;Song, Changho;Jung, Sangwoo
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.3
    • /
    • pp.311-319
    • /
    • 2021
  • Objective: To investigate the effect of emphasized initial contact by using a wearable air-pressure insole to provide auditory-feedback with variations of maximum peak pressure (MPP) of the affected side on spatiotemporal gait parameters and gait symmetry of stroke patients Design: A cross-sectional study Methods: Eighteen stroke patients participated in this study. All subjects walked five trials using an air-pressure insole that provides auditory feedback with different thresholds set on the insole. First, subjects walked without any auditory feedback. Then, the MPP threshold on the affected side was set from 70% and increase threshold by 10% after each trial until 100%. They walked three times or more on the gait analyzer for each trial, and the average values were measured. Before starting the experiment, subjects measured body weight, initial gait abilities and affected side MPP without auditory feedback. Results: Temporal and spatial variables were significantly increased in trials with auditory feedback from air-pressure insole except for non-paralyzed single support time and spatial gait symmetry compared to trials without auditory feedback(p<0.05). Among the four different thresholds, the walking speed, unaffected side single support time, affected and unaffected side stride, and affected side step length were greatest at 80% threshold of maximum peak, while affected single support time, temporal gait symmetry, and unaffected step length were greatest at the maximum peak of 100% threshold. Conclusions: These results indicate that auditory feedback gait using air-pressure insoles can be an effective way to improve walking speed, single support time, step length, stride, and temporal gait symmetry in stroke patients.

Interpretation of Corrosion Mechanism on Anode side Separator for MCFC (용융탄산염 연료전지에서 양극측 분리판의 부식기구 해석)

  • Park, Hyeong-Ho;Lee, Min-Ho;Lee, Kyu-Taek
    • Korean Journal of Materials Research
    • /
    • v.8 no.6
    • /
    • pp.571-576
    • /
    • 1998
  • This study was carried out for investigating the corrosion behaviors, corrosion mechanisms, and behaviors of elements on a separator for a molten carbonate fuel cell under both the electrolyte and anode side environment. A 310S austenitic stainless steel was used as the separator material. Corrosion proceeded via three steps; the formation step of corrosion product in which rapid corrosion takes place until stable corrosion product is formed after the beginning of corrosion, the protection step against corrosion until breakaway occurs after the formation step of stable corrosion product and the advancing step of corrosion after the breakaway. From the standpoint of the behavior of the elements in the specimen, Fe and Cr, Ni were enriched in the region of corrosion product, in the region of corrosion protection, and at the Cr-deplete zone, respectively. With respect to corrosion mechanism, ionization of electrolyte at the anode side was the main corrosion mechanism, and the final corrosion products were $LiFeO_2$ and $LiCrO_2$ at the anode side.

  • PDF

A Study on the Fitness of Children's Shoes -Centered on the Correlation of Shoes Size and Walking- (아동화의 적합성에 관한 연구 -신발크기와 보행과의 관계를 중심으로-)

  • 심부자
    • Journal of the Korean Home Economics Association
    • /
    • v.29 no.3
    • /
    • pp.23-34
    • /
    • 1991
  • With 10 subjects of 6-year-old children residing in Pusan, I analyzed the relation of walking types(step angle, step width, step and stride) and wear comfort according to the style and size fo shoes in order to reveal the fitness of children's shoes centered on the relationship of shoes size and walking. Three styles of children's shoes(laced and unlaced formal shoes, magic-taped sports shoes) ranging in five different size were used. The following are conclusions. 1. As to step angle, there was no conceivable change in the left side, while the right side had a significance in accordance with the shoes size at p<0.001. As the size grew, right step angle of all shoes increased, with unlaced shoes having more influence than others. Step angle were the smallest when all the sampled shoes made the difference of 5mm between foot size and shoes size. 2. As to step width, there was no conceivable change in the style of shoes, while shoes size had a significance at p<0.001. As the size grew, step width also increased. Step width were the smallest when all the sampled shoes made the difference of 5mm between foot size and shoes size. 3. Step and stride, however, took no significance at all, since they were not influenced by the size or style of the shoes. 4. Wear comfort had a significance at the level of p<0.001. Since it was influenced by the size or style of the shoes. The best wear comfort was felt when all the sampled shoes had laces and magic tapes as well as the size with the difference of 5-10mm between foot size and shoes size.

  • PDF

Effects of Step-up Training on Walking Ability of Stroke Patients by Different Support Surface Characteristics

  • Oh, Geun-Sik;Choi, Yu-Ran;Bang, Dae-Hyouk;Cha, Yong-Jun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.3
    • /
    • pp.99-104
    • /
    • 2017
  • PURPOSE: Gait disturbances in patients with hemiplegic stroke involve asymmetry of stance time. Step box training is used to supplement the limitations of stair walking training and increasing the torque value of the paralyzed lower leg's strength. This study aimed to investigate whether step-up training on unstable support could change walking ability in patients with chronic stroke. METHODS: Thirty stroke patients were randomly assigned to the step-up training group (experimental group), that performed training on an unstable surface, and the control group, that performed training on a stable surface. Walking speed, step length, and cadence were measured before and after training. Paired t-tests were used to compare pre- and post-intervention data, while the independent samples t-test was used to determine intergroup differences. Values of p < .05 were considered statistically significant. RESULTS: There was a significant difference in walking ability before versus after the intervention in both groups, although the experimental group showed greater differences than the control group (walking velocity by 8.1%; step length of the non-paralyzed side by 6.9%, respectively; p<.05). CONCLUSION: Step-up training might be more effective on an unstable surface than on a stable surface for increasing walking speed and step length of the non-paralyzed side.

A Study on the Characteristics of Circular Piezoelectric Transformner which has Multi-layered Crescent-Shaped Input Electrode (적층형 Crescent-Shaped Input Type 원형 압전변압기의 특성)

  • Jeong, Seong-Su;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.223-224
    • /
    • 2006
  • This paper present a new disk-type piezoelectric transformer. The input side of the transformer has a crescent-shaped electrode and the output side has a focused poling direction. This transformer has multi-layered structure. The piezoelectric transformers operated m each transformer's resonance vibration mode. The electrodes and poling directions on commercialy available piezoelectric ceramic disks were designed so that the planar or shear mode coupling factor ($k_p,\;k_{15}$) becomes effective rather than the transverse mode coupling factor ($k_{31}$). The Resonance frequency is 65.22[kHz] and maximum voltage step-up ratio is 149. Multi-layered transformer has better efficiency and step-up ratio than the single-layered transformer.

  • PDF

A Computational Study on the Unsteady Lateral Loads in a Rocket Nozzle

  • Nagdewe, Suryakant;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.289-292
    • /
    • 2008
  • Highly over-expanded nozzle of the rocket engines will be excited by non-axial forces due to flow separation at sea level operations. Since rocket engines are designed to produce axial thrust to power the vehicle, non-axial static and/or dynamic forces are not desirable. Several engine failures were attributed to the side loads. Present work investigate the unsteady flow in an over-expanded rocket nozzle in order to estimate side load during a shutdown/starting. Numerical computations has been carried out with density based solver on multi-block structured grid. Present solver is explicit in time and unsteady time step is calculated using dual time step approach. AUSMDV is considered as a numerical scheme for the flux calculations. One equation Spalart-Allmaras turbulence model is selected. Results presented here is for two nozzle pressure ratio i.e. 100 and 20. At 100 NPR, restricted shock separation (RSS) pattern is observed while, 20 NPR shows free shock separation (FSS) pattern. Side load is observed during the transition of separation pattern at different NPR.

  • PDF

A Study on the One Bath One Step Thermosol Dyeing of Polyester/Cotton Blended Fabrics (폴리에스터/면 혼방직물의 1욕 1단 서모졸 염색에 관한 연구)

  • Ro, Duck-Kil
    • Textile Coloration and Finishing
    • /
    • v.20 no.1
    • /
    • pp.16-21
    • /
    • 2008
  • In this study the effects of swelling and fixing agent for the cotton side of polyester/cotton blended fabrics and the thermosol temperature on the dyeing properties and fastness. were investigated, when the polyester/cotton blended fabrics were dyed with a disperse dye which was able to dye both side of fiber by one bath one step thermosol process. The obtained results are as follows; The dye adsorption decreased with the increase of cotton blend ratio in polyester/cotton blended fabrics, when the ratio of swelling and fixing agent for cotton side was constant. As the thermosol temperature increased up to $210^{\circ}C$, the dye adsorption were increased, but that effect was less significant when the cotton blend ratio was higher.

Double Side SMT and Molding Process Development for mPossum Package

  • Kim, ByongJin;Cho, EunNaRa;Kim, ChoongHoe;Lee, YoungWoo;Lee, JaeUng;Ryu, DongSu;Jung, GyuIck;Kang, DaeByoung;Khim, JinYoung;Yoon, JuHoon;Kim, Sun-Joong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.43-48
    • /
    • 2016
  • 3-Dimensional System in Package (3-D SiP) structure (Amkor calls it mPossum-molded Possum) using double side Surface Mount Technology (SMT) and double side molding was evaluated in order to achieve small/thin form factor as well as good functionality by integration and double side layout. As the new platform on laminate substrate basis, molding process was challenge in mold flow balance at top and bottom side and package warpage control over the overall assembly process. There were two types of different molding process evaluated with 1) 1-step molding which was done at both side at the same time and 2) 2-step molding which was done at the conventional molding process twice. Mold simulation helped to narrow down the material selections and parameters available before actual sample build. There were many challenges for this first trial in design/ parameter and material types but optimized them to enable this structure.