• Title/Summary/Keyword: Side step

Search Result 575, Processing Time 0.02 seconds

Flow Structure Around a Rectangular Prism Placed in a Thick Turbulent Boundary Layer (두꺼운 난류경계층 내부에 놓인 직사각형 프리즘 주위의 유동구조)

  • Kim, Gyeong-Cheon;Ji, Ho-Seong;Chu, Jae-Min;Lee, Seok-Ho;Seong, Seung-Hak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.578-586
    • /
    • 2002
  • Flow structures around a rectangular prism have been investigated by using a PIV(Particle Image Velocimetry) technique. A thick turbulent boundary layer was generated by using spires arid roughness elements. The boundary layer thickness, displacement thickness and momentum thickness were 650mm, 117.4mm and 78mm, respectively. The ratio between the model height(40mm) and the boundary layer thickness H/$\delta$, was 0.06. The Reynolds number based on the free stream velocity and the height of the model was 7.9$\times$10$^3$. The PIV measurements were performed at three different wall normal planes. Three recirculation regions at forward facing step, top of the roof and backward facing step are clearly seen and show three dimensional features. Dramatic changes of flow patterns are observed in the wake regions in the different spanwise wall normal planes. Instead of reattachment and recirculation zone, rising streamlines are depicted at the normal planes near the side wall due to the interaction with a rising horse shoe vortex. The peak of turbulent kinetic energy occurs at the separation bubble on top of the roof and the magnitude is 2.5 times higher compared with that of the wake region.

Microbiological Hazard Analysis for Seasoned Sweet Potato Stems in a Free Meal service Operation for the Elderly in Sungnam (성남시 무료 노인 급식에서 제공되는 고구마줄기무침의 미생물학적 위해 분석)

  • Park, Ji-Hyun;Kim, Hae-Young
    • Korean journal of food and cookery science
    • /
    • v.23 no.3 s.99
    • /
    • pp.378-387
    • /
    • 2007
  • In this study, we investigated the application of HACCP for a prepared side dish of sweet potato stems, within a free meal service system for the elderly in the Sungnam area. Total bacterial counts (TBC) and levels of coliforms and Esherichia coli (E.coli) were analyzed through an eight step cooking process. The TBCs of the raw samples ranged between 3.30 and 1.37${\times}10^4$ CFU/g per 100 cm$^2$ The trimmed, blanched, and drained sweet potato stems showed a mean TBC value of 1.37${\times}10^4$ CFU/g, and the level of coliforms was 1.48${\times}10^3$ CFU/g. Among the eight samples, however, after stir-frying and serving, the TBC decreased to a standard satisfactory level, and a coliforms and E. coli were not found. A five step process was used and samples were taken to check the microbial quality of the cook and cooking equipment. Here we tested for TBC, coliforms, Staphylococcus aureus (S. aureus), and Salmonella. Specifically, the TBC and number of coliforms were examined on the cook's hand's, cutting board, and knife, as they represented hazards for cross-contamination. The three inspection steps of preparation of the trimmed, rinsed, blanched, and drained sweet potato stems, cook's' hands, cutting board and knife were all considered CCPs, and a manual of cooking process management was established to improve the risk factors in this study. In conclusion, this study reinforces that microbiological analysis is as a valuable tool for checking what points and stages of the cooking process must be controlled.

The APIs Design for the Database Management of the Network Game Using Design Patterns (디자인 패턴을 적용한 네트워크 게임의 DB 관리 APIs 설계)

  • Kim Jong-Soo;Kwon Oh-Jun;Kim Tai-Suk
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.1
    • /
    • pp.101-108
    • /
    • 2006
  • Developing a network game that is serviced on the internet requires a lot of work, time and manpower. Therefore, it is important to design a game in such a way so that existing design codes could be used. The database for the multi-player network game is accessed from many clients. To manage the resource effectively, it is required to design the APIs to be minimized the database access and to be dealt with the related data efficiently. For this, it is needed to apply the object-oriented design for the related software modules. In the paper, we propose the design patterns of GoF to implement the APIs thatis needed to deal with the database resource. The database design through the analysis of some game's GUI has the advantage to create the optimized schema set more quickly, because it minimize the review step and the modification step of the database design generally. In addition, we apply to the design patterns of GoF for the APIs design of the server-side database. These reduce the times of the program call between the game server and the database server. These also make easily the maintenance for the already developed APIs, and it makes easily the addition of new APIs.

  • PDF

Surgical Anatomy of Lateral Extracavitary Approach to the Thoracolumar Spine - Cadaveric Study - (흉요추부 외측 강외 접근법(Lateral Extracavitary Approach)의 수술해부학적 구조 - 사체해부실험 -)

  • Kim, Sang-Don;Suh, Jung-Keun;Ha, Sung-Kon;Kim, Joo-Han;Cho, Tae-Hyung;Park, Jung-Yul;Kim, Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1187-1192
    • /
    • 2001
  • Objective : The lateral extracavitary approach(LECA) to the thoracolumbar spine is known as one of procedure which allows not only direct vision of pathologic lesion, but also ventral decompression, and dorsal fixation of the spine through the same incision. However, some drawbacks of LECA, including the technically- demanding, time-consuming, unfamiliar surgical anatomy and excessive blood loss, make surgeons to hesitate to use this approach. This study is to provide the surgical anatomy of LECA using cadavers, for detailed informations when LECA is considered for the surgery. Methods : We performed the 10 cadaveric studies, 7 male and 3 female, and careful dissection was carried out on right side of thoracolumbar region, except one for thoracic region. The photographs with micro-lens were taken to depict the close-up findings and for demonstrating detailed anatomy. Results : The photographs and hand-drawings demonstrated the relationships among the musculature, segmental vessels and nerve roots seen during each dissection plane. The lateral branches of dorsal rami of spinal nerve and the transverse process were confirmed to be the most important landmark of this approach. Conclusion : We concluded that detailed anatomical findings for LECA through this step-by-step dissection would be useful during operative intervention to reduce the intraoperative complications in LECA.

  • PDF

Investigation of TaNx diffusion barrier properties using Plasma-Enhanced ALD for copper interconnection

  • Han, Dong-Seok;Mun, Dae-Yong;Gwon, Tae-Seok;Kim, Ung-Seon;Hwang, Chang-Muk;Park, Jong-Wan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.178-178
    • /
    • 2010
  • With the scaling down of ULSI(Ultra Large Scale Integration) circuit of CMOS(Complementary Metal Oxide Semiconductor)based electronic devices, the electronic devices become more faster and smaller size that are promising field of semiconductor market. However, very narrow line width has some disadvantages. For example, because of narrow line width, deposition of conformal and thin barrier is difficult. Besides, proportion of barrier width is large, thus resistance is high. Conventional PVD(Physical Vapor Deposition) thin films are not able to gain a good quality and conformal layer. Hence, in order to get over these side effects, deposition of thin layer used of ALD(Atomic Layer Deposition) is important factor. Furthermore, it is essential that copper atomic diffusion into dielectric layer such as silicon oxide and hafnium oxide. If copper line is not surrounded by diffusion barrier, it cause the leakage current and devices degradation. There are some possible methods for improving the these secondary effects. In this study, TaNx, is used of Tertiarybutylimido tris (ethylamethlamino) tantalum (TBITEMAT), was deposited on the 24nm sized trench silicon oxide/silicon bi-layer substrate with good step coverage and high quality film using plasma enhanced atomic layer deposition (PEALD). And then copper was deposited on TaNx barrier using same deposition method. The thickness of TaNx was 4~5 nm. TaNx film was deposited the condition of under $300^{\circ}C$ and copper deposition temperature was under $120^{\circ}C$, and feeding time of TaNx and copper were 5 seconds and 5 seconds, relatively. Purge time of TaNx and copper films were 10 seconds and 6 seconds, relatively. XRD, TEM, AFM, I-V measurement(for testing leakage current and stability) were used to analyze this work. With this work, thin barrier layer(4~5nm) with deposited PEALD has good step coverage and good thermal stability. So the barrier properties of PEALD TaNx film are desirable for copper interconnection.

  • PDF

Computer Simulation of the Transanal Endoscopic Microsurgery for the Improvement of Optimal Operation Range (경항문 내시경 수술 도구에서의 최적 활동 반경 개선을 위한 컴퓨터 시뮬레이션 연구)

  • Kim, Hyung-Tae;Kim, Kwang-Gi;Sohn, Dae-Kyung;Kim, Hyun-Ho;Nam, Kyoung-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.482-488
    • /
    • 2009
  • Conventional devices for transanal endoscopic microsurgery that are currently used clinically for intestine or rectal cancer patients have 40 mm external diameter of rectoscope tube - induces anal damage and long-term postoperative pain for small-sized patients. In this paper, we designed rectum and rectoscope models and calculated the changing trends of operation area of the surgical tools in accordance with the step-by-step variation of design parameters of the rectoscope tube - external diameter, axial length, and distal angle. Using the results of computer simulation, we suggested an optimal set of design parameters that minimizes external diameter of the rectoscope tube and at the same time, maintains similar operation area of the surgical tools compared with commercialized devices (${\geq}\;4274.7mm^2$). The results of the simulation showed that the optimal design parameters were 35 mm external diameter, 100 mm axial length, and $45^{\circ}$ distal angle of the rectoscope tube. This result can be applied to the development of endoscopic microsurgery device that can minimize side effects to the intestine or rectal cancer patients.

Kinetic Study of Xylan Hydrolysis and Decomposition in Concentrated Sulfuric Acid Hydrolysis Process by $^1H$-NMR Spectroscopy ($^1H$-NMR에 의한 Xylan의 황산가수분해 과정에서 나타나는 반응 동력학 연구)

  • Cho, Dae-Haeng;Kim, Yong-Hwan;Kim, Byung-Ro;Park, Jong-Moon;Sung, Yong-Joo;Shin, Soo-Jeong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.43 no.3
    • /
    • pp.52-58
    • /
    • 2011
  • Proton-NMR spectroscopic method was applied to kinetic study of concentrated sulfuric acid hydrolysis reaction, especially focused on 2nd step of acid hydrolysis with deferent reaction time and temperature as main variables. Commercial xylan extracted from beech wood was used as model compound. In concentrated acid hydrolysis, xylan was converted to xylose, which is unstable in 2nd hydrolysis condition, which decomposed to furfural or other reaction products. Without neutralization steps, proton-NMR spectroscopic analysis method was valid for analysis of not only monosaccharide (xylose) but also other reaction products (furfural and formic acid) in acid hydrolyzates from concentrated acid hydrolysis of xylan, which was the main advantages of this analytical method. Higher temperature and longer reaction time at 2nd step acid hydrolysis led to less xylose concentration in xylan acid hydrolyzate, especially at $120^{\circ}C$ and 120 min, which meant hydrolyzed xylose was converted to furfural or other reaction products. Loss of xylose was not match with furfural formation, which meant part of furfural was degraded to other undetected compounds. Formation of formic acid was unexpected from acidic dehydration of pentose, which might come from the glucuronic acid at the side chain of xylan.

Electrochemical Migration Characteristics of Sn-3.0Ag-0.5Cu Solder Alloy in NaBr and NaF Solutions (NaBr 및 NaF 용액에 대한 Sn-3.0Ag-0.5Cu 솔더 합금의 Electrochemical Migration 특성)

  • Jung, Ja-Young;Jang, Eun-Jung;Yoo, Young-Ran;Lee, Shin-Bok;Kim, Young-Sik;Joo, Young-Chang;Chung, Tai-Joo;Lee, Kyu-Hwan;Park, Young-Bae
    • Journal of Welding and Joining
    • /
    • v.25 no.3
    • /
    • pp.57-63
    • /
    • 2007
  • Electrochemical migration characteristics of Pb-free solder alloys are quantitatively correlated with corrosion characteristics in harsh environment conditions. In-situ water drop test and corrosion resistance test for Sn-3.0Ag-0.5Cu solder alloys were carried out in NaBr and NaF solutions to obtain the electrochemical migration lifetime and pitting potential, respectively. Sn-3.0Ag-0.5Cu solder alloy shows similar ionization and electrochemical migration behavior with pure Sn because of Ag and Cu do not migrate due to the formation of resistant intermetallic compounds inside solder itself. Electrochemical migration lifetime in NaBr is longer than in NaF, which seems to be closely related to higher pitting potential in NaBr than NaF solution. Therefore, it was revealed that electrochemical migration lifetime of Sn-3.0Ag-0.5Cu solder alloys showed good correlation to the corrosion resistance, and also the initial ionization step at anode side is believed to be the rate-determining step during electrochemical migration of Pb-free solders in these environments.

The Eigenvalues and Their Relationships for the Rectangular Frame (4각형 골조의 고유치와 고유치 간의 관계)

  • Lee, Soo-Gon;Kim, Soon-Cheol;Song, Chang-Young;Song, Sang-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.139-150
    • /
    • 2005
  • Finite element method is applied to the determinations of the two eigenvalues(the elastic critical load and the natural frequence of lateral vibrations) of single story-3 equal bay rectangular frame. The analysis parameters are taper parameter ${\alpha}$ for column, and beam span to column height ratio, ${\beta}$ and second moment area ratio of beam to column, ${\Upsilon}$. Support condition at the column base and sway condition at the column top are also considered in the stability analysis of frame. The changes in the coefficient of eigenvalue are represented by algebraic function of analysis parameter. The coefficients estimated by the proposed algebraic function show good agreement with those determined by finite element method, which suggest the design aid role of the proposed function. By increasing the column axial forces step by step, the corresponding frequencies are also determined, which makes one examine or confirm the relationship suggested by other studies.

Hydrogen production with high temperature solar heat thermochemical cycle using NiFe2O4/m-ZrO2 device (NiFe2O4/m-ZrO2 device를 이용한 고온 태양열 열화학 싸이클의 수소 생산)

  • Lee, Jin-Gyu;Shin, Il-Yoong;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.107-114
    • /
    • 2011
  • Two-step thermochemical cycle using ferrite-oxide($Fe_3O_4$) device was investigated. The $H_2O$(g) was converted into $H_2$ in the first experiment which was performed using a dish type solar thermal system. However the experiment was lasted only for 2 cycles because the metal oxide device was sintered and broken down. Another problem was that the reaction was taken place mainly on a side of the metal oxide device. The $m-ZrO_2$, which was widely known as a material preventing sintering, was applied on the metal oxide device. The ferrite loading rate and the thickness of the metal oxide device were increased from 10.67wt% to 20wt% and from 10mm to 15mm, respectively. The chemical reactor having two inlets was designed in order to supply the reactants uniformly to the metal oxide device. The second-experiment was lasted for 5 cycles, which was for 6 hours. The total amount of the $H_2$ production was 861.30mL.