• 제목/요약/키워드: Side ratio

검색결과 2,046건 처리시간 0.044초

Sm 490A강으로 제작된 T형 편면용접이음재의 굽힘피로강동에 관한 연구 (A Study on Bending Fatigue Strength of One Side Fillet Welded T-Joint by SM 490A steel)

  • 엄동석;강성원;이태훈;이해우;조수형
    • Journal of Welding and Joining
    • /
    • 제16권5호
    • /
    • pp.134-141
    • /
    • 1998
  • In this study, a fillet size for bending fatigue strength of one side fillet welded T-joint, used in box type girder and other welding structure, was investigated by bending fatigue test with or without edge preparation and burn through, with variation of joint shape. As a result, the following conclusions were obtained. (1) In one side fillet welded T-joint, the larger the leg length, the greater the bending fatigue strength. The increase in bending fatigue strength. (2) One side filet welded T-joint with edge preparation showed higher bending fatigue strength than that with twofold-large leg length and without edge preparation. (3) In one side fillet welded T-joint without edge preparation, both manual welding and automatic welding were carried out with same condition. In this case, automatic welding shoed deeper penetration and more increased horizontal leg length than manual welding, so that automatic welding offers grater bending fatigue strength. (4) For one side fillet welded T-joint without edge preparation, the ratio(h/t) of the leg length (h) and the main plate thickness (t) in which toe crack can occur was 1.2 over. (5) In one side fillet welded T-joint with edge preparation, the burn through led to reduced bending fatigue strength. However, this bending fatigue strength was higher than that of one side fillet welded T-joint without edge preparation and with a larger leg length.

  • PDF

정규압밀된 연약점토의 압밀시험시 측면 마찰의 영향 (Effect of Side Friction on Consolidation Test of Normally Consolidated Kaolinite Slurry)

  • 이장근
    • 한국지반환경공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.61-68
    • /
    • 2008
  • 압밀시험시 시료의 두께에 대한 직정의 비율이 크면 일반적으로 측면마찰은 없다고 간주된다. 그러나, 시료의 두께가 커질수록 측면 마찰의 영향은 무시할 수 없게 된다. 본 연구에서는 정규압밀된 카올리나이트 슬러리의 압밀시험시 측면마찰의 영향을 조사하였다. 압밀시험을 통해 압밀시험곡선, 과잉간극수압, 압밀-간극비, 투수계수-간극비 관계를 측정하였고, 압밀-간극비 관계에 있어 측면마찰의 영향을 고려하기 위해 Taylor(1942)가 제안한 식을 적용하였다. 측정된 압밀시험곡선과 과잉간극수압에 대해 수치해석 결과와 비교 분석을 통해 측면 마찰이 압밀시험에 미치는 영향을 검토하였다. 그 결과, 측면 마찰의 영향을 고려한 수치해석 결과는 측면 마찰을 무시한 결과보다 측정값에 근사한 것으로 나타났으며, 측면 마찰은 압밀-간극비 관계 뿐만 아니라 압밀시간에도 영향을 주는 요인이라는 결과를 얻을 수 있었다.

  • PDF

Non-Gaussian feature of fluctuating wind pressures on rectangular high-rise buildings with different side ratios

  • Jia-hui Yuan;Shui-fu Chen;Yi Liu
    • Wind and Structures
    • /
    • 제37권3호
    • /
    • pp.211-227
    • /
    • 2023
  • To investigate the non-Gaussian feature of fluctuating wind pressures on rectangular high-rise buildings, wind tunnel tests were conducted on scale models with side ratios ranging from 1/9~9 in an open exposure for various wind directions. The high-order statistical moments, time histories, probability density distributions, and peak factors of pressure fluctuations are analyzed. The mixed normal-Weibull distribution, Gumbel-Weibull distribution, and lognormal-Weibull distribution are adopted to fit the probability density distribution of different non-Gaussian wind pressures. Zones of Gaussian and non-Gaussian are classified for rectangular buildings with various side ratios. The results indicate that on the side wall, the non-Gaussian wind pressures are related to the distance from the leading edge. Apart from the non-Gaussianity in the separated flow regions noted by some literature, wind pressures behind the area where reattachment happens present non-Gaussian nature as well. There is a new probability density distribution type of non-Gaussian wind pressure which has both long positive and negative tail found behind the reattachment regions. The correlation coefficient of wind pressures is proved to reflect the non-Gaussianity and a new method to estimate the mean reattachment length of rectangular high-rise building side wall is proposed by evaluating the correlation coefficient. For rectangular high-rise buildings, the mean reattachment length calculated by the correlation coefficient method along the height changes in a parabolic shape. Distributions of Gaussian and non-Gaussian wind pressures vary with side ratios. It is inappropriate to estimate the extreme loads of wind pressures using a fixed peak factor. The trend of the peak factor with side ratios on different walls is given.

정상인의 안면부 운동 시 표면근전도 측정 연구 (A Study of Surface Electromyography Measurement of Facial Muscles in Normal Person)

  • 이형걸;정다정;최유민;김석희;육태한;송범용;김종욱
    • Journal of Acupuncture Research
    • /
    • 제31권2호
    • /
    • pp.51-63
    • /
    • 2014
  • Background or Objectives : The purpose of this study is to measure surface Electromyography(sEMG) of facial muscles in normal person and to find method for standardizing of sEMG's value. Methods : We measured 3points on face, frontalis muscle($GB_{14}$), zygomaticus muscle($SI_{18}$), orbicularis oris muscle($LI_{19}$) of 40 normal person by sEMG. 40 normal person consist with two groups, each 20 male, 20 female. Average age of subject was $26.50{\pm}4.79$. SEMG instrument QEMG-4 XL was used. After training exercise of facial muscles, sEMG's root mean square value was measured once. Results : 1. In whole experimental group, frontalis muscle's both side average was $78.36{\pm}40.87$, zygomaticus muscle's both side average was $84.70{\pm}49.81$, orbicularis oris's both side average was $104.83{\pm}38.81$. 2. Left side of Frontalis muscle, both side of zygomaticus muscle are high marked in male than female in statistically. 3. In whole experimental group, average of ratio comparing smaller value with bigger value in difference between left side and right side was $19.60{\pm}12.88$ %. 4. Average of asymmetry index(AI) was $11.46{\pm}8.36$ %. orbicularis oris muscle's average of AI had least difference was $8.95{\pm}7.50$ %. zygomaticus muscle's average of AI had most difference was $13.95{\pm}8.90$ %. Conclusions : The result of this study could provide useful information of field of sEMG is used in oriental medicine treatment of facial muscles. To assess efficacy of treatment in facial muscles, we need to standardize facial muscle's sEMG values by using AI, ratio comparing values and etc.

성인 남성용 런닝형 니퍼패턴 개발 (A Study on the Running Type Nipper Pattern Development for Adult men)

  • 조평훈;손후조;나미향
    • 한국생활과학회지
    • /
    • 제16권3호
    • /
    • pp.577-585
    • /
    • 2007
  • This research aimed for 20 latter man whose body shape of torso alters remarkably to develop nipper pattern of running type considered characteristic of body shape of 20 latter man to keep rather balanced body shape against middle age when body shape changes extremely. 1. running type nipper pattern design. Pattern of running, lining and nipper were designed by flattening surface shell. A basis line of running pattern is completed by applying reduction ratio after 3 times of modification & complement based on surface shell. Nipper pattern is designed with design line set by a plaster cast based on running pattern line. Lining pattern is designed with lining design line set by a plaster cast based on running type outside material and nipper pattern. 2. Functional evaluation of research and commercial nipper. Functional inspection through dress test was applied 5point evaluation method and the result of functional inspection on the sight of a wearer is that research nipper(running reduction ratio 15%, nipper reduction ratio 18%) averaged more 4.8point but commercial nipper averaged less 1.8point in the aspect of 20 items such as wear sensibility, motional function and external appearance aesthetic. Research running type nipper scored high in order of motional function, looks of side, back, front and whole and wear sensibility. Functional inspection in the point of view of an observer is that research nipper(running reduction ratio 15%, nipper reduction ratio 18%) averaged over 4.8point and commercial nipper averaged under 1.9point in 17 items of external appearance beauty. Research running type nipper marked high in order of looks of back, whole, front and side.

자궁경부암의 고선량율 강내치료 선량계획 분석 (Analysis of High Dose Rate Intracavitary Radiotherapy(HDR-ICR) Treatment Planning for Uterine Cervical Cancer)

  • 채규영
    • Radiation Oncology Journal
    • /
    • 제12권3호
    • /
    • pp.387-392
    • /
    • 1994
  • Purpose : This study was done to confirm the reference point variation according to variation in applicator configuration in each fractioation of HDR ICR. Materials and Methods : We analyzed the treatment planning of HDRICR for 33 uterine cervical cancer patients treated in department of therapeutic radiology from January 1992 to February 1992. Analysis was done with respect to three view points-Interfractionation A point variation, interfractionation bladder and rectum dose ratio variation, interfractionation treatment volume variation. Interfractionation A point variation was defined as difference between maximum and minimum distance from fixed rectal point to A point in each patient. Interfractionation bladder and rectum dose ratio variation was defined as difference between maximum and minimum dose ratio of bladder or rectum to A point dose in each patient, Interfractionation treatment volume variation was defined as difference between miximum and minimum treatment volume which absorbed over the described dose-that is, 350 cGy or 400 cGy-in each patient. Results The mean of distance from rectum to A point was 4.44cm, and the mean of interfractionation distance variation was 1.14 cm in right side,1.09 cm in left side. The mean of bladder and rectum dose ratio was $63.8\%$ and $63.1\%$ and the mean of interfractionation variation was $14.9\%$ and $15.8\%$ respectively. With fixed planning administration of same planning to all fractionations as in first fractionation planning-mean of bladder and rectum dose ratio was $64.9\%$ and $72.3\%$.and the mean of interfraction variation was $28.1\%$ and $48.1\%$ reapectively. The mean of treatment volume was $84.15cm^3$ and the interfractionation variation was $21.47cm^2$. Conclusion : From these data, it was confirmed that there should be adapted planning for every fractionation ,and that confirmation device installed in ICR room would reduce the interfractionation variation due to more stable applicator configuration.

  • PDF

원형 편파 마이크로스트립 $12\times12$ 직-병렬 배열 안테나 설계 (Design of a Circular Polarization Microstrip $12\times12$ Series-Parallel Array Antenna at 10 GHz)

  • 이영주;정명숙;박위상
    • 한국전자파학회논문지
    • /
    • 제11권1호
    • /
    • pp.26-36
    • /
    • 2000
  • 본 논문에서는 위성 통신에 이용될 수 있는 X-band원형 편파 마이크로스트립 $12\times12$배열 안테나를 설계하였다. 복사체는 대형배열에 적합한 개구면 결합형 마이크로스트립 환형 안테나를 사용하였으며, broadside 방향의 빔을 형성시키기 위해 소자간 간격은 $0.7\lambda_0$로 하였다. 또한 높은 이득과 좋은 원형 편파 특성을 위해 직-병렬 구조으1 sequential array 형태의 급전구조를 사용하였다. 제작된 안테나는 본 교의 compact range에서 측정하였 다 그 칠파 10,3 GHz에서 27.88 dB의 directivity에 대해 25.55 dB의 높은 gam을 가지며 이로써 60 %의 높은 효율을 가짐을 확인했다 또한 1.74 dB의 axial ratio와 - 13 dB의 side-lobe-level 특성을 가졌다. 그리고 VSWR 2 기준으로 볼 때 약 43 %의 넓은 반사 계수 대역폭플 가지며,16 %의 axial ratio 대역폭을 가짐을 알 수 있었다.

  • PDF

알루미늄 플레이트-핀 열교환기의 분배기 형상비에 따른 분배특성에 관한 해석적 연구 (Numerical Study on the Distribution Characteristics of Aluminum Plate-Fin Heat Exchangers According to the Distributor Aspect Ratio)

  • 이응찬;강훈;허재혁;김용찬;박재홍;조성열
    • 대한기계학회논문집B
    • /
    • 제35권8호
    • /
    • pp.805-814
    • /
    • 2011
  • 알루미늄 플레이트-핀 열교환기는 석유 및 가스 처리공정에서 널리 사용되고 있다. 알루미늄 플레이트-핀 열교환기의 성능은 각 유체의 헤더 및 분배기에서의 분배 성능에 의하여 크게 영향을 받는다. 본 연구에서는 CFD(Computational fluid dynamics)를 이용하여 알루미늄 플레이트-핀 열교환기의 측면 입구 형태의 분배기를 모델링하고, 입구 조건과 형상비의 변화에 따른 상대 및 절대 불균등 분배도를 고찰하여 최적 분배기 형상비를 제시하였다.

마그네틱 감속기의 극수비 영향 분석 (Analysis of Pole Ratio Effect of Magnetic Reducer)

  • 정광석
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.277-283
    • /
    • 2020
  • 기계식 기어의 치를 영구자석으로 대체한 동심 마그네틱 기어에서 원주방향을 따라 놓인 모든 자석이 동력 전달에 관여하므로 감속비를 결정하는 자석의 극수비는 마그네틱 기어의 거동 특성에 큰 영향을 미친다. 본 논문에서는 극수비를 변화시켜가며 마그네틱 기어에서 생성되는 전달토크의 밀도, 동손을 고려한 토크의 효율, 코깅 특성을 포함한 토크의 품질 등을 유한요소 해석을 이용하여 비교 분석하였다. 구동측의 극수를 2극에서 5극까지 변화시킬 때 전달토크가 최대가 되는 최적의 극수비가 존재함을 확인하였으며 이는 모듈레이터를 통한 구동측 자기장의 필터링 성분에 직접적인 영향을 받다. 전달 효율 역시 와전류 생성 밀도와 자기장간에 비례특성이 있으므로 전달 토크 밀도와 유사한 경향을 나타내는 것을 알 수 있으며 낮은 기어비에서는 95% 이상의 효율을 보인다. 제한된 극수를 갖는 영구자석의 상호작용에 기인하는 코깅 특성은 일반적인 동기 모터에서와 같이 구동측 자석의 개수와 모듈레이터 치의 개수간의 최소공배수에 반비례하는 것을 확인할 수 있었다. 전달 토크 평가를 위해 실제 시험 모델이 제작되었고 실증시험이 진행되었다.

Mechanical behaviour of composite columns composed of RAC-filled square steel tube and profile steel under eccentric compression loads

  • Ma, Hui;Xi, Jiacheng;Zhao, Yaoli;Dong, Jikun
    • Steel and Composite Structures
    • /
    • 제38권1호
    • /
    • pp.103-120
    • /
    • 2021
  • This research examines the eccentric compression performance of composite columns composed of recycled aggregate concrete (RAC)-filled square steel tube and profile steel. A total of 17 specimens on the composite columns with different recycled coarse aggregate (RCA) replacement percentage, RAC strength, width to thickness ratio of square steel tube, profile steel ratio, eccentricity and slenderness ratio were subjected to eccentric compression tests. The failure process and characteristic of specimens under eccentric compression loading were observed in detail. The load-lateral deflection curves, load-train curves and strain distribution on the cross section of the composite columns were also obtained and described on the basis of test data. Results corroborate that the failure characteristics and modes of the specimens with different design parameters were basically similar under eccentric compression loads. The compression side of square steel tube yields first, followed by the compression side of profile steel. Finally, the RAC in the columns was crushed and the apparent local bulging of square steel tube was also observed, which meant that the composite column was damaged and failed. The composite columns under eccentric compression loading suffered from typical bending failure. Moreover, the eccentric bearing capacity and deformation of the specimens decreased as the RCA replacement percentage and width to thickness ratio of square steel tube increased, respectively. Slenderness ratio and eccentricity had a significantly adverse effect on the eccentric compression performance of composite columns. But overall, the composite columns generally had high-bearing capacity and good deformation. Meanwhile, the mechanism of the composite columns under eccentric compression loads was also analysed in detail, and the calculation formulas on the eccentric compression capacity of composite columns were proposed via the limit equilibrium analysis method. The calculation results of the eccentric compression capacity of columns are consistent with the test results, which verify the validity of the formulas, and the conclusions can serve as references for the engineering application of this kind of composite columns.