Estimation of slamming coefficients on local members of offshore wind turbine foundation (jacket type) under plunging breaker

  • Jose, Jithin;Choi, Sung-Jin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권6호
    • /
    • pp.624-640
    • /
    • 2017
  • In this paper, the slamming coefficients on local members of a jacket structure under plunging breaker are studied based on numerical simulations. A 3D numerical model is used to investigate breaking wave forces on the local members of the jacket structure. A wide range of breaking wave conditions is considered in order to get generalized slamming coefficients on the jacket structure. In order to make quantitative comparison between CFD model and experimental data, Empirical Mode Decomposition (EMD) is employed for obtaining net breaking wave forces from the measured response, and the filtered results are compared with the computed results in order to confirm the accuracy of the numerical model. Based on the validated results, the slamming coefficients on the local members (front and back vertical members, front and back inclined members, and side inclined members) are estimated. The distribution of the slamming coefficients on local members is also discussed.

CRASHWORTHINESS ASSESSMENT OF SIDE IMPACT OF AN AUTO-BODY WITH 60TRIP STEEL FOR SIDE MEMBERS

  • Huh, H.;Lim, J.H.;Song, J.H.;Lee, K.S.;Lee, Y.W.;Han, S.S.
    • International Journal of Automotive Technology
    • /
    • 제4권3호
    • /
    • pp.149-156
    • /
    • 2003
  • This paper is concerned with the energy absorption efficiency of auto-body side structures for the conventional steel and 60TRIP high strength steel. In order to evaluate the energy absorption efficiency, the dynamic crash analysis is carried out with the regulation of US-SINCAP. The analysis adopts the Johnson-Cook model for the dynamic material properties, which have been obtained from dynamic material tests. For the sake of the dynamic material properties, the analysis has been accurately peformed for the crashworthiness assesment. The analysis result provides deformed shapes, amounts of penetration and accelerations at several important points during crash. The result confirms that 60TRIP greatly improves the crashworthiness of the side members without sacrificing the weight and thus can be used for the light-weight design of an auto-body.

고속충돌시험기 개발 및 부재의 충돌특성 실험에 관한 연구 (I) (A Study on the Development of Test Rig for High Speed Frontal Crash and Test of Members ($\textrm{I}$))

  • 강신유;장인배;김헌영;정규진;박경환
    • 한국정밀공학회지
    • /
    • 제17권6호
    • /
    • pp.119-126
    • /
    • 2000
  • In this paper. a simple high-speed crash test rig for members of vehicle was developed for the improvement of crashworthiness of vehicle's side rail. The cart hanging the specimen is accelerated up to 35 mph by the force of freely dropping weight and 1:3 accelerating pulleys. The cart with shock absorbers travels on the rail roads, so it does not transfer any additional vibration to the specimen. To measure the test results, two types of accelerator are considered. the one is a strain gage type and the other is a piezo type. The test rig is rated good to test the specimen like a side rail of vehicle as developing the vehicle's structures in the early design stage.

  • PDF

A Study on the Development of Test Rig for High Speed Frontal Crash and Test of Members

  • Shin-You. Kang;In-Bae. Chang;Jang, Hye-Jeong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권3호
    • /
    • pp.21-27
    • /
    • 2002
  • In this paper, a simple test rig of high-speed crash for the front members of vehicles was developed for the improvement of crashworthiness of vehicle's side rail. The cart hanging the specimen is accelerated up to 35 mph by the traction wire and by the force of freely dropping weight and 1:3 accelerating pulleys. The cart with shock absorbers travels on the rail roads, so it does not transfer any additional vibration to the specimen. In order to measure the energy absorbed by the specimen when it collapse to the wall and during it deform, the two strain gage type load cells are used at the wall place. The test rig rated good to test the specimen like a side rail of vehicle as developing the vehicle's structures in the early design stage.

내목도리의 발생과 시대적 변화에 관한 연구 (A Study on the Occurrence and A change in the times of the Nemok-dori)

  • 허경도;정명섭
    • 건축역사연구
    • /
    • 제29권1호
    • /
    • pp.39-49
    • /
    • 2020
  • A dapo type bracket system which consists of chuganpo(柱間包) and chusangpo(柱上包) with a fake-beam adopted a nemok-dori member to cope with oemok-dori member in order to obtain balance between the outer-side and the inner-side of the bracket system. The middle part of the longest rater in the dapo system is supported by three points made by oemok-dori, jusim-dori and nemok-dori members and the area between the rafer supporting points forms a supporting area. The increase of rafter supporting points and supporting area leads to heightening the structural stability and the efficiency of load delivery. In the eave of dapo system the portion where the three supporting points formed by oemok-dori, jusim-dori and nemok-dori members shows as 33% in the early period, 71% in the middle period and 78% in the later period. On the contrary the portion where more than one of the three dori members were omitted shows as 67% in the early period, 29% in the middle period and 22% in the later period. This is the result of the increase of the number and the distance of steps in the dapo bracket system as time goes on. This is because the structural role of three supporting points becomes important as the increase of distance between the dori members leads to the increase of load which burdens on each dori member.

Pullout Test of Headed Reinforcing Bar in RC or SFRC Members with Side-Face Blowout Failure

  • Lee, Chang-Yong;Kim, Seung-Hun;Lee, Yong-Taeg
    • Architectural research
    • /
    • 제22권1호
    • /
    • pp.33-39
    • /
    • 2020
  • In this study, side-face blowout failure strength of high strength headed reinforcing bar, which is vertically anchoring between RC or SFRC members, is evaluated throughout pullout test. The major test parameters are content ratio of high strength steel fibers, strength of rebar, length of anchorage, presence of shear reinforcement, and the side concrete cover thickness planned to be 1.3 times of the rebar. In pullout test, tensile force was applied to the headed reinforcing bar with the hinged supports positioned 1.5 and 0.7 times the anchorage length on both sides of the headed reinforcing bar. As a result, the cone-shaped crack occurred where the headed reinforcing bar embedded and finally side-face blowout failure caused by bearing pressure of the headed reinforcing bar. The tensile strength of specimens increased by 13.0 ~26.2% with shear reinforcement. The pullout strength of the specimens increased by 3.6 ~15.4% according to steel fiber reinforcement. Increasing the anchoring length and shear reinforcement were evaluated to reduce the stress bearing ration of the total stress.

성형효과를 고려한 해석을 통한 차체 측면구조의 충돌 및 진동 성능평가 (Evaluation of Crashworthiness and NVH Performances of Side Structure with Finite Element Analysis considering Stamping Effects)

  • 김세호;김기풍;최원호
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.119-127
    • /
    • 2008
  • In this paper, the influence of the stamping effect is investigated in the performance analysis of a side structure. The analysis covers the performance evaluation such as the crashworthiness and NVH. Stamping analyses are carried out for the center pillar and the side sill made of high strength steels. Then, numerical simulations are carried out in order to identify the stamping effect on the crashworthiness, the natural frequency and the normal mode. The result shows that the analysis of the side structure considering the forming history leads to a different result from that without considering the forming effect. The variation of the system response fully reveals effects of thinning and hardening of members on the performance prediction of vehicle parts. The analysis results demonstrate that the design of auto-body members should be carried out considering the stamping history for accurate assessment of various performances.

고온.고습 환경 하에서의 계면수 변화에 따른 CFRP모자형 단면 부재의 압궤특성 (Collapse Characteristics of CFRP Hat Shaped members According to Variation of Interface Numbers under the Hygrothermal Environment)

  • 양용준;차천석;양인영
    • 한국생산제조학회지
    • /
    • 제18권3호
    • /
    • pp.241-247
    • /
    • 2009
  • It is important to satisfy the requirements and standards for the protections of passengers in a car accident. There are lots of studies on the crushing energy absorption of a structure members in automobiles. We have studied to investigate collapse characteristics and moisture absorption movements of CFRP(Carbon Fiber Reinforced Plastics) hat shaped sectional members when CFRP laminates are under the hygrothermal environment. In particular, the absorbed energy, mean collapse load and deformation mode were analyzed for side members which absorbed most of the collision energy. Variation of CFRP interlaminar numbers is important to increase the energy absorption capability. Therefore we have made a static collapse experiment to research into the difference of absorbed energy and deformation mode between moisture absorbed specimen and non-moisture absorbed.

  • PDF

열습환경 하에서의 적층각도 변화에 따른 CFRP 모자형 단면부재의 압궤특성 (Collapse Characteristics of CFRP Hat Shaped Members under the Hygrothermal Environment According to Stacking Angle)

  • 양용준;양인영;심재기
    • 한국생산제조학회지
    • /
    • 제18권5호
    • /
    • pp.507-513
    • /
    • 2009
  • It is important to satisfy the requirements and standards for the protections of passengers in a car accident. There are lots of studies on the crushing energy absorption of structure members in automobiles. We have investigated collapse characteristics and moisture absorption movements of CFRP(Carbon Fiber Reinforced Plastics) hat shaped sectional members when CFRP laminates are under the hygrothermal environment. The absorbed energy, mean collapse load and deformation mode were analyzed for side members which absorbed most of the collision energy. Therefore we have made a static collapse experiment to research into the difference of absorbed energy and deformation mode between moisture absorbed specimen and non-moisture absorbed specimen.

  • PDF