• Title/Summary/Keyword: Side image

Search Result 1,021, Processing Time 0.031 seconds

Side lobe free medical ultrasonic imaging with application to assessing side lobe suppression filter

  • Jeong, Mok Kun;Kwon, Sung Jae
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.355-364
    • /
    • 2018
  • When focusing using an ultrasonic transducer array, a main lobe is formed in the focal region of an ultrasound field, but side lobes also arise around the focal region due to the leakage. Since the side lobes cannot be completely eliminated in the focusing process, they are responsible for subsequent ultrasound image quality degradation. To improve ultrasound image quality, a signal processing strategy to reduce side lobes is definitely in demand. To this end, quantitative determination of main and side lobes is necessary. We propose a theoretically and actually error-free method of exactly discriminating and separately computing the main lobe and side lobe parts in ultrasound image by computer simulation. We refer to images constructed using the main and side lobe signals as the main and side lobe images, respectively. Since the main and side lobe images exactly represent their main and side lobe components, respectively, they can be used to evaluate ultrasound image quality. Defining the average brightness of the main and side lobe images, the conventional to side lobe image ratio, and the main to side lobe image ratio as image quality metrics, we can evaluate image characteristics in speckle images. The proposed method is also applied in assessing the performance of side lobe suppression filtering. We show that the proposed method may greatly aid in the evaluation of medical ultrasonic images using computer simulations, albeit lacking the use of actual experimental data.

Digital Image Processing of Side Scan Sonar for Underwater Man-made Structure (수중 인공구조물에 대한 사이드스캔소나 탐사자료의 영상처리)

  • Shin, Sung-Ryul;Lim, Min-Hyuk;Kim, Kwang-Eun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.344-354
    • /
    • 2009
  • Side scan sonar using acoustic wave plays a very important role in the underwater, sea floor, and shallow marine geologic survey. In this study, we have acquired side scan sonar data for the underwater man-made structures, artificial reefs and fishing grounds, installed and distributed in the survey area. We applied digital image processing techniques to side scan sonar data in order to improve and enhance an image quality. We carried out digital image processing with various kinds of filtering in spatial domain and frequency domain. We tested filtering parameters such as kernel size, differential operator, and statistical value. We could easily estimate the conditions, distribution and environment of artificial structures through the interpretation of side scan sonar.

A study on the effect of side-lobe on axial image of confocal microscope (공초점 광학현미경에서의 side-lobe 감소방안에 대한 연구)

  • 김억봉;류재연;최치규;김두철;유영훈
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.356-361
    • /
    • 2001
  • The effect of side-lobe on axial image is investigated. We show, using computer simulation and experimentally, that an optimized axial response can be achieved by minimized side-lobe according to the Herschel condition and that the appearance of sidelobes is decreased by balancing phase error.

  • PDF

Suppression of side lobe using distance weight in spectrum of channel signal in medical ultrasound imaging system (의료용 초음파 영상 시스템에서 채널신호의 스펙트럼에서 거리 가중치를 이용한 부엽의 억제)

  • Yu Rim Lee;Mok Kun Jeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.203-213
    • /
    • 2023
  • In medical ultrasound imaging systems, Side lobes may appear if signals outside the imaging point are not completely removed during receive focusing. If the time signal of the side lobe overlaps with the time signal (main lobe) from the image point, it is difficult to completely remove it using filter processing in the time domain. However, In the receive focusing process, when time-channel signals are Fourier-transformed, the main lobe and side lobe signals are spatially separated in the spectral domain. Therefore, the side lobes can be suppressed by multiplying the image with magnitude weights, which are determined by the magnitudes of the main and side lobes calculated in the spectral domain. In addition, when the main lobe and the side lobe spectrum are adjacent, the distance weight was applied based on the distance between them. In a 5 MHz ultrasound imaging system using a 64-channel linear transducer, point reflector and speckle images with cysts of various brightness were synthesized and weights were applied to the ultrasound image. Using computer simulations, we confirmed that the side lobes were greatly reduced without affecting the spatial resolution in the point reflector image, and the contrast was significantly improved in the cyst image with computer simulations.

Analysis of Plants Shape by Image Processing (영상처리에 의한 식물체의 형상분석)

  • 이종환;노상하;류관희
    • Journal of Biosystems Engineering
    • /
    • v.21 no.3
    • /
    • pp.315-324
    • /
    • 1996
  • This study was one of a series of studies on application of machine vision and image processing to extract the geometrical features of plants and to analyze plant growth. Several algorithms were developed to measure morphological properties of plants and describing the growth development of in-situ lettuce(Lactuca sativa L.). Canopy, centroid, leaf density and fractal dimension of plant were measured from a top viewed binary image. It was capable of identifying plants by a thinning top viewed image. Overlapping the thinning side viewed image with a side viewed binary image of plant was very effective to auto-detect meaningful nodes associated with canopy components such as stem, branch, petiole and leaf. And, plant height, stem diameter, number and angle of branches, and internode length and so on were analyzed by using meaningful nodes extracted from overlapped side viewed images. Canopy, leaf density and fractal dimension showed high relation with fresh weight or growth pattern of in-situ lettuces. It was concluded that machine vision system and image processing techniques are very useful in extracting geometrical features and monitoring plant growth, although interactive methods, for some applications, were required.

  • PDF

Depth-based Correction of Side Scan Sonal Image Data and Segmentation for Seafloor Classification (수심을 고려한 사이드 스캔 소나 자료의 보정 및 해저면 분류를 위한 영상분할)

  • 서상일;김학일;이광훈;김대철
    • Korean Journal of Remote Sensing
    • /
    • v.13 no.2
    • /
    • pp.133-150
    • /
    • 1997
  • The purpose of this paper is to develop an algorithm of classification and interpretation of seafloor based on side scan sonar data. The algorithm consists of mosaicking of sonar data using navigation data, correction and compensation of the acouctic amplitude data considering the charateristics of the side scan sonar system, and segmentation of the seafloor using digital image processing techniques. The correction and compensation process is essential because there is usually difference in acoustic amplitudes from the same distance of the port-side and the starboard-side and the amplitudes become attenuated as the distance is increasing. In this paper, proposed is an algorithm of compensating the side scan sonar data, and its result is compared with the mosaicking result without any compensation. The algorithm considers the amplitude characteristics according to the tow-fish's depth as well as the attenuation trend of the side scan sonar along the beam positions. This paper also proposes an image segmentation algorithm based on the texture, where the criterion is the maximum occurence related with gray level. The preliminary experiment has been carried out with the side scan sonar data and its result is demonstrated.

Consumption values and components of self-image and self-evaluation (자기이미지와 자기평가의 구성요인과 소비가치)

  • Oh, Hyun-Jeong
    • Journal of the Korean Home Economics Association
    • /
    • v.44 no.11
    • /
    • pp.67-78
    • /
    • 2006
  • Self-concept is a multi-dimensional characteristic including self-image and self-evaluation. Self-image is the descriptive side of self-concept and is composed of the real self-image and the ideal self-image. Self-evaluation is the appraisable side self-concept and is composed of the internal self-concept, external self-concept and total score of self-concept. The purposes of this study were to determine the correlation of self-image and self-evaluation and to identify the effects of self-image and self-evaluation on consumption value. The data were collected from 237 college women residing in Gwangju using a questionnaire to investigate real/ideal self-image, self-evaluation and consumption value. The results were analyzed with factor analysis, Pearson's correlation and multiple regression analysis using statistical program SPSS 10.0. The results of this research were as follows. 1. The real self-image and ideal self-image had a significant correlation with internal self-concept, external self-concept and total score of self-concept. It was ensured that self-image and self-evaluation are one side of the multidimensional self-concept. 2. The real/ideal self-image and internal/external self-evaluation had a significant influence on consumption value. The real self-image and external self-evaluation were the most important variables explaining the consumption value.

A Study on The Image Expression of Side Scan Sonar (Side Scan Sonar 영상표현에 관한 연구)

  • Jang, Won-Sil;Yoon, Ki-Han;Kim, Young-Il
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.152-153
    • /
    • 2005
  • Side scan sonar System occupies an important position as one of marine survey equipments. The purpose of this research is to express sonar' scan images in underwater and compare with the measured size, shape and the quality of the material. Also we confirm the effectiveness of obtained images using the Side scan sonar.

  • PDF

Side Information Extrapolation Using Motion-aligned Auto Regressive Model for Compressed Sensing based Wyner-Ziv Codec

  • Li, Ran;Gan, Zongliang;Cui, Ziguan;Wu, Minghu;Zhu, Xiuchang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.2
    • /
    • pp.366-385
    • /
    • 2013
  • In this paper, we propose a compressed sensing (CS) based Wyner-Ziv (WZ) codec using motion-aligned auto regressive model (MAAR) based side information (SI) extrapolation to improve the compression performance of low-delay distributed video coding (DVC). In the CS based WZ codec, the WZ frame is divided into small blocks and CS measurements of each block are acquired at the encoder, and a specific CS reconstruction algorithm is proposed to correct errors in the SI using CS measurements at the decoder. In order to generate high quality SI, a MAAR model is introduced to improve the inaccurate motion field in auto regressive (AR) model, and the Tikhonov regularization on MAAR coefficients and overlapped block based interpolation are performed to reduce block effects and errors from over-fitting. Simulation experiments show that our proposed CS based WZ codec associated with MAAR based SI generation achieves better results compared to other SI extrapolation methods.

The Effects of a Mental Image Drawing on Left Neglect: a Case Study (심상그리기가 좌편 무시현상에 미치는 영향: 사례연구)

  • Kim, Ha-Kyung;Hwang, Young-Jin;Jeong, Ok-Ran
    • Speech Sciences
    • /
    • v.12 no.3
    • /
    • pp.91-102
    • /
    • 2005
  • This study investigated to the effects of a mental image drawing in RHD patients with left neglect. Three subjects participated in this study. All subjects were right handed and native speaker of korean. In task 1, the patients were presented with visual stimulus card directly above the response sheet and were asked to draw the picture. In task 2, they were presented with items auditorily and asked to draw the picture(mental image drawing). In all experimental conditions, there was no response time limit. The results showed that the subjects showed left neglect leaving some space on the left side in task 1. And the picture was drawn the left side from the right in direction. However, the neglect disappeared in task 2. And the picture was drawn the right side from the left in direction. The results of the present study suggested that a mental image drawing technique can be effective in treating individuals who exhibit left neglect. Also, the picture direction showed that the korean normality was same.

  • PDF