• Title/Summary/Keyword: Side Injection

Search Result 589, Processing Time 0.03 seconds

A Study on the Injection Characters of The Back Side Grouting Method by a Model Test (모형실험을 통한 배면지수 그라우팅기법에 관한 연구)

  • Chun, Byung-Sik;Choi, Choon-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.175-182
    • /
    • 2002
  • The cement injection technology on the purpose of ground reinforcement and cut-off has been used in construction sites until now. However, recently it is applied to prevent leakage of underground structure. In this study, applicability of the back side waterproof grouting method was verified through performing field model tests and reviewing case histories. From the results of this study, injection shape of the back side waterproof grouting method was appeared to be root type, and waterproof effect by injection of cement grout material was excellent because grout material infiltrated into boundary between wall of structure and back side ground to be waterproof layer. Components influencing infiltration of injection material are type of soil and degree of compaction. For effective injection, injection pressure has to vary gradually from high pressure to low pessure and small quantity of injection material has to be injected for long times. Also, spacing of injection hole must be designed considering condition of back side ground, injection area, W/C ratio, the number of injection and injection pattern properly.

Optical 60 GHz signal generation using side-band injection-locking of semiconductor lasers (반도체 레이저의 Side-band Injection-Locking을 이용한 광학적 60 GHz 신호 생성)

  • Ryu, Hye-Seung;Seo, Young-Kwang;Choi, Woo-Young
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.2
    • /
    • pp.161-165
    • /
    • 2003
  • Optical 60 ㎓ millimeter-wave (MMW) signal generation is demonstrated using the sideband injection-locking method in the master/slave configuration, where two slave lasers are locked to two among several side-bands produced by the direct rf-modulation of a master laser. These two locked slave laser outputs beat against each other in the photo-detector and produce stable and very pure 60 ㎓ signals.

Effect of Shockwave on Diesel Spray Characteristics in Ultra High Pressure Injection (극초고압 디젤분무의 충격파가 디젤분무특성에 미치는 영향)

  • Jeong, Dae-Yong;Lee, Jong-Tai
    • Journal of ILASS-Korea
    • /
    • v.10 no.1
    • /
    • pp.10-16
    • /
    • 2005
  • To investigate the effect of shockwave on diesel spray characteristics under ultra high pressure injection, the velocity of spray tip and shock wave were investigated using the visualization of spray by schlieren method. Spray characteristics such as the spray radius, height, and droplets size were analyzed. It is found in this study that shock wave, produced by ultra high injection pressure, propagates faster than spray tip. Spray radius of right side of nozzle tip was shorter than that of left side and spray height of right side of nozzle tip was thicker than that of left side. Droplets sue was increased at 414MPa in injection pressure because of pressure gradient between inner and outer of tile spray caused by shockwave.

  • PDF

Effect of Geometrical Parameters on Discharge Coefficients of a Shear Coaxial Injector (전단동축형 분사기의 유량계수에 대한 형상학적 변수들의 영향)

  • Ahn, Jonghyeon;Lee, Keunseok;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.25 no.3
    • /
    • pp.95-102
    • /
    • 2020
  • Six shear coaxial injectors for a 3 tonf-class liquid rocket engine using oxygen and methane as propellants were designed and manufactured by considering geometric design parameters such as a recess length and a taper angle. Cold-flow tests on the injectors were performed using water and air as simulants. By changing the water mass flow rate and air mass flow rate, the injection pressure drop under single-injection and bi-injection was measured. The discharge coefficients through the injector oxidizer-side and fuel-side were calculated and the discharge coefficient ratio between bi-injection and single-injection was obtained. Under single-injection, the recess served to reduce the injection pressure drop on the injector fuel-side. For the injectors without recess, the discharge coefficients under bi-injection were almost the same as those under single-injection. However, for the injectors with recess, the taper angle and bi-injection had a significant effect on the discharge coefficient.

Comparison of pain intensity of anterior middle superior alveolar injection with infiltration anesthetic technique in maxillary periodontal surge

  • Shirmohammadi, Adileh;Faramarzi, Masoumeh;Lafzi, Ardeshir;Kashefimehr, Atabak;Malek, Sepideh
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.2
    • /
    • pp.45-49
    • /
    • 2012
  • Purpose: The aim of the present clinical trial was to compare pain during injection of anterior middle superior alveolar (AMSA) technique with that of infiltration injection technique in the maxilla in periodontal flap surgeries of patients referring to the Department of Periodontics, Faculty of Dentistry, Tabriz University of Medical Sciences. Methods: Twenty subjects with an age range of 20 to 40 years were selected for the present study. One side of the maxilla was randomly selected as the test side and the other as the control side using a flip of a coin. AMSA technique was used on the test side and infiltration technique was used on the control side for anesthesia. On both sides 2% lidocaine containing 1:80,000 epinephrine was used for anesthesia. The operator obtained the visual analogue scale for each patient immediately after the injection and immediately after surgery. Data was analyzed using descriptive statistical methods (frequency percentages, means and standard deviations) and Wilcoxon's test using SPSS ver. 13 (SPSS Inc.). Statistical significance was defined at P<0.05. Results: There were no statistically significant differences in pain during injection between the two techniques (P=0.856). There were statistically significant differences in postoperative pain between the two injection techniques (P=0.024). Conclusions: Postoperative pain in AMSA injection technique was less than that in the infiltration technique. Therefore, the AMSA technique is preferable in the periodontal surgeries for the anesthesia of palatal tissues given the fact that it has other advantages, too.

An Analytic Study on the Occurrence of Adverse Drug Reactions of Traditional Chinese Medicine Injections (중약주사제 부작용 발생에 관한 분석 연구)

  • Hwang, Ji Hye;Song, Ho Sueb
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.35 no.6
    • /
    • pp.219-227
    • /
    • 2021
  • The purpose of this study is to analyze the side effects (ADR) of Traditional Chinese Medicine (TCM) injections by age, injection type, symptoms, and causes, and to find preventive solutions for ADR. For the ADR of TCM injection data collected during the search period from January 1, 2010 to December 31, 2020, the correlation between each section was analyzed by subdividing it into age, injection type, symptoms and causes. CNKI, PubMed, and EMBASE were used to collect the clinical data. 'Chinese herbal injection', 'Traditional Chinese Medicine injection', 'Chinese herbal injection side effect', 'Chinese herbal injection adverse drug reaction' were used for the keyword from the database. All data were collected mainly for TCM injection and the causes of ADR due to TCM injection. However, data not related to the relevant study or TCM injection were excluded from this study. Among a total of 941 studies collected during the search period from January 1, 2010 to December 31, 2020, a total of 10 studies were selected for final analysis. In 1462 clinical data sets, ADR by gender was higher in males than females. By age, 41 to 60 years were the most common. The incidence of ADR by injection type was highest in the blood regulating injection type. Data analysis showed Xueshuantong injection had the highest ADR. Among the symptoms of ADR, skin diseases were the most common. The most common cause of ADR was the unreasonable use of drugs. In China, for ADR management, the use of TCM injections is recommended according to the basic principles for the clinical use of TCM injections established by the Chinese government. In this study, we analyzed the current status and causes of ADR in TCM injections, and found a preventive solution. It is expected that it can be used as basic data to increase the usability of pharmacopuncture and herbal medicines in Korea in the future.

The Change of Facial Contouring after Unilateral Injection of Botulinum Toxin in Unilateral Masseter Hypertrophy Patients (편측성 교근비대 환자에서 편측 보툴리눔 독소 주사 후 안모의 변화)

  • Cha, Yu-Rim;Kim, Young-Gun;Kim, Ji-Hyun;Shim, Young-Joo;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.247-251
    • /
    • 2011
  • Botulinum toxin type A (BoNT-A) is used for treating bilateral masseter hypertrophy since 1994. Recently there have been more clinical studies in this area, with some authors reporting that BoNT-A can reduce the size of the masseter muscle, as documented by photography, ultrasonography, computed tomography, and 3D(three dimensional) laser scan. However, earlier studies were only for bilateral masseter hypertrophy cases, not for unilateral masseter hypertrophy cases. The aim of this study was to use 3D laser scanning to evaluate changes in the external facial contour induced by unilateral BoNT-A injection. BoNT-A was injected into hypertrophic masseter muscle unilaterally in 10 patients with asymmetric masseter hypertrophy. The clinical effects of unilaterally injected BoNT-A were evaluated before the injection and 4, 8, and 12weeks after the injection using 3D laser scan. And the mean values of both sides (injection and non-injection sides) were compared with. At injection side, mean values of the volume and the bulkiest height at each time point diminished significantly between pre-injection and 4, 8, and 12weeks post-injection. At non-injection side, in contrast, mean values of the volume and the bulkiest height diminished also but less than that of injected side, and there was no statistical significance. In this limited study, we concluded that the unilaterally BoNT-A injection side showed greater mean values of the reduction of muscle volume than non-injection side at 4, 8, and 12 weeks after the injection.

Effects of different topical anesthetics on pain from needle insertion and injection, and the influence of anxiety in patients awaiting endodontic treatment

  • Fatih Aksoy;Samet Tosun
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.3
    • /
    • pp.25.1-25.11
    • /
    • 2022
  • Objectives: This study aimed to evaluate the effects of 5% lidocaine and 2.5% lidocaine/2.5% prilocaine topical anesthetic on pain during needle insertion and infiltration injection in the labial mucosa of anterior maxillary teeth, and to assess the relationship between patients' anxiety and pain scores. Materials and Methods: The Modified Dental Anxiety Scale questionnaire was applied and recorded. Patients were randomly divided into 4 groups (n = 30), as follows: G1 group: 5% lidocaine and placebo for 1 minute, G2 group: 2.5% lidocaine/2.5% prilocaine and placebo for 1 minute, G3 group: 5% lidocaine and placebo for 3 minutes, and G4 group: 2.5% lidocaine/2.5% prilocaine and placebo for 3 minutes. Before the application of topical anesthesia, one side was randomly selected as the topical anesthesia and the contralateral side as the placebo. The pain levels were measured with Visual Analog Scale (VAS) immediately after needle insertion and injection and were compared. The correlation between anxiety and pain scores was analyzed. Results: Administration of 5% lidocaine for 1 minute had significantly higher pain scores for both insertion and infiltration injection than the other groups (p < 0.05). There was a significant moderate positive correlation between dental anxiety and the injection-induced VAS pain score in the placebo side in all groups (p < 0.05). Conclusions: Topical anesthetics significantly reduced the pain caused by both needle insertion and injection pain in comparison to the placebo side. The pain scores of patients with dental anxiety were lower on the topical anesthesia compared to the placebo side.

EFFECT OF THE SHAPE OF IMPINGEMENT PLATE ON THE VAPORIZATION AND FORMATION OF FUEL MIXTURE IN IMPINGING SPRAY

  • Kang, J.J.;Kim, D.W.;Choi, G.M.;Kim, D.J.
    • International Journal of Automotive Technology
    • /
    • v.7 no.5
    • /
    • pp.585-593
    • /
    • 2006
  • The effect of the shape of the side wall on vaporization and fuel mixture were investigated for the impinging spray of a direct injection(DI) gasoline engine under a variety of conditions using the LIEF technique. The characteristics of the impinging spray were investigated under various configurations of piston cavities. To simulate the effect of piston cavity configurations and injection timing in an actual DI gasoline engine, the parameters were horizontal distance from the spray axis to side wall and vertical distance from nozzle tip to impingement plate. Prior to investigating the side wall effect, experiments on free and impinging sprays for flat plates were conducted and these results were compared with those of the side wall impinging spray. For each condition, the impingement plate was located at three different vertical distances(Z=46.7, 58.4, and 70 mm) below the injector tip and the rectangular side wall was installed at three different radial distances(R=15, 20, and 25 mm) from the spray axis. Radial propagation velocity from spray axis along impinging plate became higher with increasing ambient temperature. When the ambient pressure was increased, propagation speed reduced. High ambient pressures tended to prevent the impinging spray from the propagating radially and kept the fuel concentration higher near the spray axis. Regardless of ambient pressure and temperature fully developed vortices were generated near the side wall with nearly identical distributions, however there were discrepancies in the early development process. A relationship between the impingement distance(Z) and the distance from the side wall to the spray axis(R) was demonstrated in this study when R=20 and 25 mm and Z=46.7 and 58.4 mm. Fuel recirculation was achieved by adequate side wall distance. Fuel mixture stratification, an adequate piston cavity with a shorter impingement distance from the injector tip to the piston head should be required in the central direct injection system.

A Study on the Filling Pattern Imbalance by Width of Gate in the Thin Plate Injection Molding (박판 사출 성형에서 게이트 폭에 따른 충전 불균형에 대한 연구)

  • Jung, Tae-Sung;Jang, Jin-Hyeok;Kim, Jon-Sun
    • Design & Manufacturing
    • /
    • v.11 no.1
    • /
    • pp.14-18
    • /
    • 2017
  • Recently, the injection-molded products are lighter, and thinner than ever. In this work, Injection molding simulation was conducted to analysis the filling pattern imbalance in high speed injection molding process for thin-wall injection component, 8 inches LGP. Numerical analysis shows that shear heated polymer near the side wall causes filling imbalance between center and side of cavity. Short shot experiments were conducted and compared with simulation results. Filling imbalance ratio showed a tendency to increase for wider fan gate.