• Title/Summary/Keyword: Side Emitting

Search Result 115, Processing Time 0.027 seconds

Attraction Effects of Sex Pheromone and LED Mass-Trap to Spodoptera exigua and Spodoptera litura (Fabricius) Adults around the Tomato Greenhouse (토마토 재배지 성페로몬 및 LED 유인 트랩을 이용한 파밤나방(Spodoptera exigua)과 담배거세미나방(Spodoptera litura) 대량 포획)

  • Lee, Jung Sup;Bang, Ji Wong;Lee, Jae Han;Jang, Hye Sook
    • Journal of Bio-Environment Control
    • /
    • v.31 no.1
    • /
    • pp.22-27
    • /
    • 2022
  • The attraction effects of light emitting diode (LED) trap to Spodoptera exigua and Spodoptera litura adults were evaluated in greenhouse and compared with those of no light trap, which is typical used in commercial trap. At this time, in order to attract these two species of moths, sex pheromone traps were installed at the top side according to the degree of tomato growth inside the tomato cultivation greenhouse around the LED trap. In addition, two types of light-emitting traps (420 nm, 470 nm) were installed in the greenhouse at 1/40 m2, respectively. Also two sex pheromone were installed inside of the greenhouse according to the height of the tomato plants. 10 days later, Blue-light trap(BLB, 470 nm wavelength) was 3.1-3.5 times more attractive than Violet-light trap(VLB, 420 nm wavelength) in S. exigua (105.6 ± 7.3) and S. litura (42.0 ± 3.1) respectively, whereas the no-light trap was little attractive to S. exigua (33.7 ± 2.8) and S. litura (12.0 ± 1.5). On the other hand, after the installation of the sex pheromone trap and the LED trap, there was no damage to S. litura (Fabricius) and S. exigua in the pesticide-free area, indicating a high possibility of control. At this time, the operating cost of the two types of LED traps was 80 won/m2 per unit area, and it was confirmed that both types of moths could be controlled. In addition, as a result of confirming the number of two types of moths caught in the sexual pheromone trap and two types of LED traps after 4 months, it was judged that eco-friendly control was possible as more than 373 moths/trap were attracted to the two types of moths.

The Combined Effects of Curcumin Administration and 630 nm LED Phototherapy against DNCB-induced Atopic Dermatitis-like Skin Lesions in BALB/c Mice (BALB/c 마우스에서 DNCB-유도 아토피 피부염 유사병변에 대한 Curcumin 투여와 630 nm LED 광치료의 병용 효과)

  • Jekal, Seung-Joo;Park, Mi-Suk;Kim, Dae-Jung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.2
    • /
    • pp.150-160
    • /
    • 2017
  • Atopic dermatitis (AD) is a chronic inflammatory skin disease. It is characterized by eczematous lesions, skin dryness, and pruritus. The existing treatment drugs for AD have side effects, especially if the drugs are taken for extended periods. Therefore, new alternative therapies are necessary. The aim of this study was to investigate the combined effects of curcumin administration and LED irradiation on AD. AD-like lesions were induced in BALB/c mice by repeated application of 1-chloro-2,4-dinitrobenzene (DNCB) to the shaved skin of the ear and neck. Thirty male BALB/c mice were divided into five groups: vehicle, DNCB, curcumin, LED, and curcumin+LED groups. Curcumin (0.1 g/kg/day) was administrated repeatedly during a period of 14 days (experimental period) and 630 nm LED irradiation ($5J/cm^2/day$) was performed in the acryl box once a day for 10 days, after inducing AD-like lesions via DNCB application. The severity of AD-like lesions was evaluated during the experimental period, using a modified SCORAD index. Both ear and neck skin tissues were examined histologically for epidermal thickness, mast cell, eosinophil counting, and dermal collagen density. Epidermal cell proliferation and apoptosis were detected using immunohistochemistry and TUNEL, respectively. These were all reduced in SCORAD index, epidermal thickness, collagen density, number of mast cell and eosinophil in dermis, and number of proliferating cell and apoptotic cell in epidermis by curcumin administration and 630 nm LED irradiation. Moreover, all parameters were significantly lower in the curcumin+LED group compared with the curcumin group and LED group. These results suggest that the combined therapy of curcumin and LED is more effective than a single treatment. We recommend that this can be a feasible alternative therapy to manage AD.

The comparison of lesion localization methods in breast lymphoscintigraphy (Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교)

  • Yeon, Joon ho;Hong, Gun chul;Kim, Soo yung;Choi, Sung wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.74-80
    • /
    • 2015
  • Purpose Breast lymphoscintigraphy is an important technique to present for body surface precisely, which shows a lymph node metastasis of malignant tumors at an early stage and is performed before and after surgery in patients with breast cancer. In this study, we evaluated several methods of body outline imaging to present exact location of lesions, as well as compared respective exposure doses. Materials and Methods RANDO phantom and SYMBIA T-16 were used for obtaining imaging. A lesion and an injection site were created by inserting a point source of 0.11 MBq on the axillary sentinel lymph node and 37 MBq on the right breast, respectively. The first method for acquiring the image was used by drawing the body surface of phantom for 30 sec using $Na^{99m}TcO_4$ as a point source. The second, the image was acquired with $^{57}Co$ flood source for 30 seconds on the rear side and the left side of the phantom, the image as the third method was obtained using a syringe filled with 37 MBq of $Na^{99m}TcO_4$ in 10 ml of saline, and as the fourth, we used a photon energy and scatter energy of $^{99m}Tc$ emitting from phantom without any addition radiation exposure. Finally, the image was fused the scout image and the basal image of SPECT/CT using MATLAB$^{(R)}$ program. Anterior and lateral images were acquired for 3 min, and radiation exposure was measured by the personal exposure dosimeter. We conducted preference of 10 images from nuclear medicine doctors by the survey. Results TBR values of anterior and right image in the first to fifth method were 334.9 and 117.2 ($1^{st}$), 266.1 and 124.4 ($2^{nd}$), 117.4 and 99.6 ($3^{rd}$), 3.2 and 7.6 ($4^{th}$), and 565.6 and 141.8 ($5^{th}$). And also exposure doses of these method were 2, 2, 2, 0, and $30{\mu}Sv$, respectively. Among five methods, the fifth method showed the highest TBR value as well as exposure dose, where as the fourth method showed the lowest TBR value and exposure dose. As a result, the last method ($5^{th}$) is the best method and the fourth method is the worst method in this study. Conclusion Scout method of SPECT/CT can be useful that provides the best values of TBR and the best score of survey result. Even though personal exposure dose when patients take scout of SPECT/CT was higher than another scan, it was slight level comparison to 1 mSv as the dose limit to non-radiation workers. If the scout is possible to less than 80 kV, exposure dose can be reduced, and also useful lesion localization provided.

  • PDF

Change in the Measured Value at 99mTc-MDP Administration before and after Bone Density Measurement using the Dual Energy X-ray Absorptiometry (이중에너지 X선 흡수법을 이용한 골밀도 측정시 99mTc-MDP 투여 전·후 측정값의 변화)

  • Kang, Yong-Gil;Won, Do-Yeon;Jung, Hong-Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • Measurement of bone marrow measurements may occur if bone marrow examination performed with bone marrow examination (bone marrow examination) and bone density (bone scan) are performed together recently. Thus, it was examined in clinical aspects that $^{99m}Tc-MDP$ compounds were affected by bone mineral density measurements. The average age of the participants in the experiment was $35.17{\pm}9.45$ and the patient fractures of the lumbar vertebrae that could affect the metabolic disease and bone density measurements affecting the metabolic disease of the 17 subjects. 6 patients with normal bone mineral density T-scores>-1.0 in 12 patients were analyzed before and after the administration of $^{99m}Tc-MDP$. In the lumbar spine, the average of $0.975{\pm}0.084g/cm^2$ and $0.966{\pm}0.078g/cm^2$ were increased by $0.009g/cm^2$. respectively In the right proximal femur, mean values were $0.909{\pm}0.078g/cm^2$ and $0.913{\pm}0.086g/cm^2$. In the right proximal thigh, mean values were $0.909{\pm}0.078g/cm^2$ and $0.913{\pm}0.08 g/cm^2$, respectively, which decreased by $0.004g/cm^2$. In the left side proximal femur, mean $0.887{\pm}0.099g/cm^2$ and $0.881{\pm}0.103g/cm^2$, respectively, increased by $0.007g/cm^2$. Therefore, the BMD changes in the lumbar region were larger than that in the proximal thigh. In addition, $^{99m}Tc-MDP$ did not affect the BMD. And a bone scan test using a technetium-labeled compound emitting a gamma-ray energy of 140 keV did not significantly affect bone density measurements. However, if the nuclear medical examination and the osteoporosis test are to be performed together, the examination should be carried out at intervals considering the exposures of the patient.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.