• Title/Summary/Keyword: Side Drop

Search Result 294, Processing Time 0.022 seconds

Effect of Ultrasonic Vibration on Culling Characteristics of Hot Rolled Strip (열연강판의 절단특성에 미치는 초음파진동의 영향)

  • 송길호;김기원;박해두
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.225-229
    • /
    • 2003
  • When hot strip is trimmed in the side trimming process at the entry side of tandem cold rolling mill, due to bad quality of trimming face and burr, product quality(saw ear)becomes so bad that it causes drop of yield and claim from customers. Therefore, it was examined that applying ultrasonic vibration is an effective method to improve quality of strip trimming face and decrease burr magnitude by decreasing shear force acting between strip trimming face and knife in side trimming process of cold rolling.

  • PDF

Analysis of Heat Transfer and Pressure Drop During Gas Cooling Process of Carbon Dioxide in Transcritical Region (초임계 영역내 $CO_2$ 냉각 열전달과 압력강하 분석)

  • 손창효;이동건;정시영;김영률;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.65-74
    • /
    • 2004
  • The heat transfer coefficient and pressure drop of $CO_2$(R-744) during gas cooling Process of carbon dioxide in a horizontal tube were investigated experimentally and theoretically. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop consist of a receiver. a variable-speed pump. a mass flowmeter, an evaporator. and a gas cooler(test section). The main components of the water loop consist of a variable-speed Pump. an constant temperature bath. and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus The test section consists of smooth, horizontal stainless steel tube of 9.53 mm outer diameter and 7.75 mm inner diameter. The length of test section is 6 m. The refrigerant mass fluxes were 200 ~ 300 kg/($m^2{\cdot}s$) and the inlet pressure of the gas cooler varied from 7.5 MPa to 8.5 MPa. The main results were summarized as follows : The predicted correlation can evaluated the R-744 exit temperature from the gas cooler within ${\pm}10%$ for most of the experimental data, given only the inlet conditions. The predicted gas cooley capacity using log mean temperature difference showed relatively food agreement with gas cooler capacity within ${\pm}5%$. The pressure drop predicted by Blasius estimated the pressure drop on the $CO_2$ side within ${\pm}4.3%$. The predicted heat transfer coefficients using Gnielinski's correlation evaluated the heat transfer coefficients on the $CO_2$ side well within the range of experimental error. The predicted heat transfer coefficients using Gao and Honda's correlation estimated the heat transfer coefficients on the coolant side well within ${\pm}10\;%$. Therefore. The predicted equation's usefulness is demonstrated by analyzing data obtained in experiments.

Sudden Foot Drop Caused by Foraminal Gas Pseudocyst

  • Kim, Hyun-Sook;Kim, Heyun-Sung;Kim, Seok-Won;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.384-386
    • /
    • 2011
  • A foraminal gas pseudocyst is a rare cause of lumbar radiculopathy. The association with a sudden foot drop has not been previously reported. Here, a 67-year-old woman with sudden foot drop on the left side is reported. Computed tomography and magnetic resonance imaging identified a foraminal gas containing lesion compressing the left L5 root at the L5-S1 foramen. The foraminal gas containing lesion compressing the L5 ganglion was successfully removed by the posterior approach. The histological diagnosis was a gas pseudocyst. This unique case of surgically proven gas pseudocyst indicates that it should be included in the differential diagnosis of patients presenting with sudden foot drop.

Soft Start-up Characteristics Analysis of Squirrel Cage Induction Generator (농형 유도 발전기의 소프트 기동 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.103-107
    • /
    • 2016
  • In general, the voltage stability of induction generator is lower than synchronous generator. Induction generator has a number of advantages over the synchronous generator on the side of price and maintenance. So Induction generator has been applied to the small hydroelectric power of low output. Induction generator usually generates a high current during grid connection. The high current that occurs during grid connection can cause a voltage drop in the system. In order to increase the supply of the induction generator, it is necessary to propose a method of reducing high current. This paper proposes some method of the soft start to reduce voltage drop caused by the large starting current. soft-start method has high voltage drop effect than direct start method, control of firing angle can be increased the voltage drop effect.

Pressure drop in packed beds with horizontally or vertically stratified structure

  • Li, Liangxing;Xie, Wei;Zhang, Zhengzheng;Zhang, Shuanglei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2491-2498
    • /
    • 2020
  • The paper concentrates on an experimental study of the pressure drop in double-layered packed beds formed by glass spheres, having the configuration of horizontal and vertical stratification. Both single-phase and two-phase flow tests are performed. The pressure drop during the test is recorded and the measured data are compared with those of homogeneous beds consisting of mono-size particles. The results show that for the horizontally stratified bed with fine particles atop coarse particles, the pressure drop in top layer is found higher than those of homogenous bed consisting of the same smaller size particles, while the measured pressure drop of bottom part is similar with those of similar homogenous bed. But for the homologous bed with upside-down structure, the stratification has little or no effect on the pressure drop of the horizontally stratified bed, and the pressure drop of each layer is almost same as that of homogeneous bed packed with corresponding spheres. Additionally, in vertically stratified bed, the pressure drops on the left and right side is almost equal and between those in homogeneous beds. It is speculated that vertically stratified structure may lead to lateral flow which redistributes the flow rate in different parts of packed bed.

Improvement of Responsivity of Unified Power Flow Controller in Digital Control System

  • Hamasaki, Shin-ichi;Miyazaki, Shinya;Takaki, Tsuyoshi;Tsuji, Mineo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.354-361
    • /
    • 2014
  • The Unified Power Flow Controller (UPFC) can flexibly manage power flow and maintain line voltage. The UPFC consists of two inverters in parallel side and series side. In parallel side, the reactive power can be compensated to improve the power factor. In series side, the voltage drop can be compensated to maintain proper line voltage. It is necessary for the operation in both sides to output the current and the voltage quickly and accurately. As the method for the UPFC control, the deadbeat control with state observer is applied. The deadbeat control is able to realize a quick response of the current and voltage control for only a sampling period compared with the general PI control. A principle and simulation results are presented in this paper.

An Experimental Study on Performance Characteristic of 30RT Closed-Type Hybrid Cooling Tower using Bare Tube (베어관을 이용한 30RT급 하이브리드 밀폐형 냉각탑의 성능특성에 관한 실험적 연구)

  • Jun, Chul-Ho;Lee, Ho-Saeng;Moon, Choon-Geun;Kim, Jae-Dol;Yoon, Jung-In
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1096-1101
    • /
    • 2005
  • In this study, the experiment of thermal performance about closed-type hybrid cooling tower was conducted. A closed type cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from top part of heat exchanger to bottom side in the inner side of tube, and spray water flows gravitational direction in the outer side of it. Air contacts of tube outer side are counterflow. The heat transfer pipe used in this experiment is a bare type tube having an outside diameter of 15.88mm. In this experiment, heat performances of the cooling tower are calculated such as overall heat transfer coefficient of between the process fluid and air, cooing capacity and pressure drop.

  • PDF

Modeling of Pressure Drop for Water Vapor Flow across Tube Banks inside Horizontal Tube Absorber

  • Phan Thanh Tong;Yoon Jung-In;Kim Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.483-493
    • /
    • 2006
  • A model for a pressure drop of water vapor flow across tube banks in a horizontal tube absorber of an absorption chiller/heater using LiBr solution as a working fluid has been developed based on a commercial 20RT(70kW) absorption chiller/heater. The numerical results show that the characteristic of the pressure drop in the shell side of the horizontal tube absorber is completely different from that in a conventional shell and tube heat exchanger. Especially, solution film thickness has significant influence on the vapor pressure drop in the horizontal tube absorber. In addition, the effects by the tube diameters, the longitudinal pitch to diameter ratio, and Reynolds number of the vapor flow, on the vapor pressure drop have been studied to evaluate the compactness of tube absorber. It was found that the vapor pressure drop decreases as tube diameter increases, the longitudinal pitch to diameter ratio increases, and Reynolds number of the vapor flow decreases. A comparison of the present study results with well-established experimental and numerical results showed a good overall agreement.

A Study on the/ Correlation Between Board Level Drop Test Experiment and Simulation

  • Kang, Tae-Min;Lee, Dae-Woong;Hwang, You-Kyung;Chung, Qwan-Ho;Yoo, Byun-Kwang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.35-41
    • /
    • 2011
  • Recently, board level solder joint reliability performance of IC packages during drop impact becomes a great concern to semiconductor and electronic product manufacturers. The handheld electronic products are prone to being dropped during their useful service life because of their size and weight. The IC packages are susceptible to solder joint failures, induced by a combination of printed circuit board (PCB) bending and mechanical shock during impact. The board level drop testing is an effective method to characterize the solder joint reliability performance of miniature handheld products. In this paper, applying the JEDEC (JESD22-B111) standard present a finite element modeling of the FBGA. The simulation results revealed that maximum stress was located at the outermost solder ball in the PCB or IC package side, which consisted well with the location of crack initiation observed in the failure analysis after drop reliability tests.

Performance Evaluation in Fin-Tube Heat Exchanger by Tow-In Winglet Pairs (Tow in 와류발생기에 의한 핀-관 열교환기의 성능실험)

  • ;Kahoru Torii
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.87-94
    • /
    • 2003
  • To reduce the air side pressure drop in air-cooled heat exchanger, tow-in type winglet vortex generators are applied. A specially designed multiple-channel test core was used in the experiments for the various geometry of winglet vortex generators. The proposed tow-in type vortex generator gives significant separation delay, reduces form drag, and removes the zone of poor heat transfer from near-wake of the tubes. The results show the significant pressure drop reduction for the tow-in win91e1 vortex generators with the similar enhancement of the heat transfer as other vortex generator applications in heat exchanger. In the range of Reynolds number of 350 to 2100 the pressure drop decrease 8∼15% and 34∼55% for the in-line and staggered tube banks, respectively, compared to those without vortex generators.