• Title/Summary/Keyword: Side Channel Type

Search Result 99, Processing Time 0.029 seconds

FLOW ANALYSIS AND PERFORMANCE EVALUATION OF HIGH PRESSURE DOUBLE STAGE RING BLOWER (고압 이단 링블로워의 삼차원 유동해석 및 성능평가)

  • Lee, K.D.;Kim, K.Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.45-48
    • /
    • 2007
  • In the present work, flow analysis has been performed for side channel type double stage ring blower by solving three-dimensional Reynolds-averaged Navier-Stokes equation. Shear stress transport model is used as turbulent closure. The commercial CFD code CFX 11.0 is used for the calculations. Each of two stage is calculated separately and the second stage inlet flow is same as the first stage outlet flow so that consecutive calculation is possible. Velocity and pressure fields have been analyzed at the midplane between blades. The numerical results are validated with experimental data for head coefficients at different flow coefficients.

  • PDF

FLOW ANALYSIS AND PERFORMANCE EVALUATION OF HIGH PRESSURE DOUBLE STAGE RING BLOWER (고압 이단 링블로워의 삼차원 유동해석 및 성능평가)

  • Lee, K.D.;Kim, K.Y.
    • Journal of computational fluids engineering
    • /
    • v.12 no.4
    • /
    • pp.85-89
    • /
    • 2007
  • In the present work, flow analysis has been performed for side channel type double stage ring blower by solving three-dimensional Reynolds-averaged Navier-Stokes equation. Shear stress transport model is used as turbulent closure. The commercial CFD code CFX 11.0 is used for the calculations. Each of two stage is calculated separately and the second stage inlet flow is same as the first stage outlet flow so that consecutive calculation is possible. Velocity and pressure fields have been analyzed at the mid-plane between blades. The numerical results are validated with experimental data for head coefficients at different flow coefficients.

Measurement of Heat Transfer Coefficient in Dimpled Channel: Effect of Dimple Arrangement and Channel Height

  • Lee, K.S.;Shin, S.M.;Park, S.D.;Kwak, J.S.;Kang, J.S.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.39-44
    • /
    • 2008
  • In this paper, heat transfer coefficients were measured in a channel with one side dimpled surface. The sphere type dimples were fabricated and the diameter and depth of dimple was 16mm and 4mm, respectively. Two channel heights of about 0.6 and 1.2 time of the dimple diameter, two dimple configuration were tested. The Reynolds numbers based on the channel hydraulic diameter was varied from 30000 to 50000. The improved hue detection based transient liquid crystal technique was used in the heat transfer measurement. Heat transfer measurement results showed that high heat transfer was induced downstream of dimples due to flow reattachment. Due to the flow recirculation on the upstream side in the dimple, the heat transfer coefficient was very low. As the Reynolds increased, the overall heat transfer coefficients also increased. With same dimple arrangement, the heat transfer coefficients and the thermal performance factor were higher for the lower channel height. As the distance between dimples became smaller, the overall heat transfer coefficient and the thermal performance factor were increased.

  • PDF

Heat Transfer and Friction Behaviour in a Channel with an Inclined Perforated Baffle

  • Krishna Putra, Ary Bachtiar;Ahn, Soo-Whan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.2
    • /
    • pp.70-76
    • /
    • 2008
  • The effects of the inclined perforated baffles on the distributions of the local heat transfer coefficients and friction factors for air flows in a rectangular channel were determined for Reynolds numbers from 23,000 to 57,000. Four different types of the baffle are used. The inclined baffles have the width of 19.8cm, the square diamond type hole having one side length of 2.55cm, and the inclination angle of $5^{\circ}$, whereas the corresponding channel width-to-height ratio was 4.95. Results show that the heat transfer and friction factor depend significantly on the number of baffle holes and Reynolds number. The friction factor decreases with increasing Reynolds number and the number of holes on the baffle, and the heat transfer performance of baffle type II (3 hole baffle) has the best value.

EFFECTS OF CHANNEL ASPECT RATIO ON FLOW AND HEAT TRANSFER CHARACTERISTICS OF PRIMARY SURFACE HEAT EXCHANGER FOR ORC (유기랭킨사이클(ORC)을 위한 주전열면 열교환기의 채널 종횡비에 따른 유동 및 열전달 특성)

  • Sung, M.J.;Ahn, J.
    • Journal of computational fluids engineering
    • /
    • v.18 no.4
    • /
    • pp.35-40
    • /
    • 2013
  • A series of numerical simulation has been carried out to study thermo-hydraulic characteristics of a primary surface type heat exchanger, which is designed for the evaporator and condenser of a geothermal ORC. Working fluid is geothermal water at hot side and R-245fa, which is a refrigerant designed for ORC, at cold side. Aspect ratio of the channel and Reynolds number are considered as design parameters. Nusselt number is presented for the Reynolds number ranging from 50 to 150 and compared to existing correlations. The result shows that higher aspect ratio channel gives better heat transfer performance within the range of investigation.

PAPR Reduction using Partial Transmit Sequences with Side Information of feedback Type (궤환형 부가정보를 사용하는 PTS 기법의 PAPR 감소)

  • 윤기후;이준서;유흥균;박진수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.330-335
    • /
    • 2003
  • PTS(partial transmit sequences) has been widely studied for reducing the PAPR of OFDM signal, since it is flexible and any spectral regrowth may not occurred. A drawback of this PTS method should transmit the side information of the optimized phase factor for correct OFDM symbol recovery. A new idea of this paper is to insert the feedback type side information in the conventional PTS method. The simulation results show that the proposed scheme has the same PAPR reduction performance as the conventional PTS without side information and OFDM data are correctly recovered to get the required BER. Also, this method is independent of the channel characteristics and can be easily realized.

Symbol Power Allocation and Channel Estimation Method for LR-WPAN System (LR-WPAN 시스템에서 심볼 전력 할당과 2개의 직교 코드를 사용한 채널 추정 기법)

  • Lee, Kyung-Tak;Lee, Sung-Jun;Sohn, Sung-Hwan;Kim, Jae-Moung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.11
    • /
    • pp.1-10
    • /
    • 2007
  • In this paper, we proposed channel estimation scheme for LR-UWB system which has low data rate for WPAN in IEEE 802.15.4a. At the transmitter, we proposed dynamic power level allocation depends on channel condition in specific period when we modulate signal. We use two orthogonal code to estimate channel at once. It can estimate channel more accurately by using two code which shows good correlation characteristic then it can estimate more accurately by spreading gain. Using estimated channel condition, we synchronize symbol timing of transmitted signal. Then determined power allocation scheme and channel information is transmitted to transmiter side. Finally, using these information, transmiter side change the power level of repeated pulse to adopt to channel condition. Simulation is performed under S-V channel for LR-WPAN in IEEE 802.15.4a and we compare the performance with a different type of receiver type. We use coherent and non-coherent method at the receiver. Simulation result shows us at the NLOS channal performance evaluation is greater than that of LOS channel and the result is independent of receiver type. In the NLOS channel, as the signal delay spreading is big, performance evaluation is also increased.

The Distribution Characteristics of Fish Community by Habitat Type in the Nonsan Stream (논산천의 서식처 유형별 어류군집의 분포특성)

  • Lee, Hwang-Goo;Choi, Jun-Kil
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.303-313
    • /
    • 2014
  • The spatial distribution characteristic of fish community were investigated at the 10 habitat types in the Nonsan stream from August, 2008 to June, 2009. The collected species during the surveyed period were 26 species belong to 6 families. Korean endemic species were Sarcocheilichthys nigripinnis morii, Squalidus japonicus coreanus, Hemiculter eigenmanni, Pseudobagrus koreanus, and Odontobutis interrupta which showed 19.2% ratio of total species. Dominant species was Zacco platypus, and subdominant species was Tridentiger brevispinis. Dominant species according to habitat types were Micropterus salmoides(substrate type pool and rock type pool), Lepomis macrochirus(channel connected pool and channel unconnected pool/abandoned type pool), T. brevispinis(channel unconnected pool/overflow type and run) and Z. platypus(riffle, meander type pool, side channel, and dam type pool). As a results of community analysis in side channel, diversity index showed relatively high values, indicating that habitat types in the Nonsan stream have relatively stable community structure. Bray-curtis cluster analysis indicated that the meander type pool and riffle showed the most similar values(80.8%). Moreover, cluster and principal component analysis were classified as 2 groups(lotic and lentic habitats).

Analysis in Technological Responses to Side-channel Attack (부채널 공격에 대한 대응기술 분석)

  • d, Young-Jin;Jo, JungBok;Lee, HoonJae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.219-222
    • /
    • 2013
  • The Side Channel attack methods proposed by P.Kocher are mainly used for cryptanalysis different cipher algorithms even though they are claimed to be strongly secured. Those kinds of attacks depend on environment implementation especially on the hardware implementation of the algorithm to the crypto module. side-channel attacks are a type of attack introduced by P.Kocher and is applicable according to each environment or method that is designed. This kind of attack can analyze and also extract important information by reading the binary code data via measurement of changes in electricity(voltage) consumption, running time, error output and sounds. Thus, in this paper, we discuss recent SPA and DPA attacks as well as recent countermeasure techniques.

  • PDF

The Design and Construction of the Anchorage of Yi Sun-Sin Grand Bridge (이순신대교 앵커리지 설계-시공사례)

  • An, Ik-Kyun;Kim, Kyung-Taek;Seo, Young-Hwa
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.14-25
    • /
    • 2010
  • The Yi Sun-Sin grand bridge is the suspension bridge which connects Myodo and Gwangyang. It is over the main navigation channel of Gwangyang Harbor. South anchorage(AN1, Myodo side) of the bridge is designed as rock anchored type. It sustains using the resistance of the underground rock's mass in Myodo. As this type of anchorage can minimize the exposure of the structure, It is economically efficient and environmentally friendly. North anchorage (AN2, Gwangyang side) is designed as the gravity type. This anchorage is 68 meters in diameter and use its own weight to support. Instead of normal rectangular diaphragm wall, the circular shape diaphragm wall is adopted to the north anchorage. It doesn't need to use internal temporary facilities, so it can significantly improve the constructability of the structure.

  • PDF