A study on measurement of VOCs in newly house (신축 공동주택의 VOCs 실태조사)

  • 유복희;윤정숙
    • Journal of the Korean housing association
    • /
    • v.13 no.5
    • /
    • pp.71-76
    • /
    • 2002
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the air pollutant indoor. In addition, Volatile Organic Compounds(VOCs) has been paid attention to as one of the main reason that causes air pollutant indoor, and the exposure of VOCs indoor is recognizes as an important factor which have an effect on the health of resident. In this study, measuring of VOCs in newly houses, and the results are as follows; 1)TVOC(Total Volatile Organic Compounds) indoor is detected high concentration(11314$\mu\textrm{g}$/㎤). 2)There are detected acetaldehyde, methylenechloride, benzene, trichloroethylene and styrene that have to take precaution against human carcinogenicity

Indoor Ventilation Efficiency Depending on Diffuser Inlet Angle (급기구 유입각도에 따른 실내 환기효율)

  • Jeon, Hyun-Jun;Jang, Yong-Jun;Yang, Kyung-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.349-355
    • /
    • 2011
  • In this study, numerical simulation has been conducted to investigate dispersion of a pollutant released from a new furniture, a kind of Sick Building Syndrome (SBS). A sofa which generates formaldehyde is implemented by using an immersed boundary method. Large Eddy Simulation (LES) is employed to obtain time-dependent velocity and concentration fields. It is shown that the ventilation efficiency in this room can be improved by changing inlet angle of diffuser, even though other conditions still remain unchanged. Both active diffusion near a sofa and air flow pattern are important parameters to enhance the ventilation efficiency.

A Study on Concentration of Volatile Organic Compounds in the Apartment House (실내공기중의 휘발성유기화합물 농도변화에 관한 연구)

  • Lee, Yun-Gyu
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.129-136
    • /
    • 2004
  • Recently, indoor air pollution has been seriously apprehended, and became a striking issue, due to the airtightness of buildings or the misuse of building materials. Especially, SHS(Sick House Syndrome) and MCS(Multi Chemical Sensitivity) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. The emission rates of VOCs is sensitively affected by the indoor/outdoor condition, construction materials, construction method, and character of ventilation facilities. Therefore, in this study, by measuring the indoor air pollution substance of the existing apartment house, the problem over this tends to be grasped and it is going to secure an improvement methods.

The Occurrences of Allergic Diseases and Accidents within Housing and Residents' Consciousness

  • Kim, Sung-Hwa;Lee, Jae-Hoon
    • Architectural research
    • /
    • v.16 no.1
    • /
    • pp.9-16
    • /
    • 2014
  • Allergic diseases as the major symptoms of Sick Building Syndrome have significantly increased because of the indoor pollutants resulted from the enhanced energy conservation performances of residential buildings. Following traffic accidents, domestic accidents are known as the second most frequent accident type. This study analyzes the occurrences of allergic diseases and home accidents caused by housing conditions, together with the residents' consciousness of the diseases and accidents. The findings of this study are expected to help develop the design guidelines and new housing types conducive to the healthy housing environment. For this study, a questionnaire survey was conducted in two rounds which include face-to-face questionnaire survey and online survey, collecting 200 responses and 1000 responses respectively. The data based on the valid 1011 responses were analyzed by Frequency Analysis and T-test.

A Study on Concentration of Volatile Organic Compounds in Newly-Apartment House by Measurement (실측을 통한 신축공동주택의 주요 VOCs 물질 농도에 관한 연구)

  • Kim, Chang-Nam;Kim, Young-Kyoung;Lee, Sung-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1220-1224
    • /
    • 2008
  • Because of the high airtightness and insulation of the building, indoor environment has been largely polluted resulted from insufficient ventilation and occurrence of new air pollutant. These factors have made worse indoor air quality and caused symptoms of the SHS(Sick House Syndrome), MCS(Multi Chemical Sensitivity). The purpose of this study is to present the fundamental strategies for improving the Indoor Air Quality(IAQ) in newly-constructed apartment buildings. To investigate the concentration of indoor air pollutants such as Formaldehyde and VOCs, the field measurement were conducted.

  • PDF

A Study on Environmental Improvement of Indoor Air Quality in University Dormitory (대학교 기숙사의 실내공기질 환경 개선에 관한 연구)

  • Kim, Ho-Jin;Yang, Jeong-Hoon;Seok, Ho-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1398-1405
    • /
    • 2008
  • As the structure, material and construction of building develop continuously, so the recent residential buildings are being large, high-rise and group. High-rise residential buildings consume a lot of energy on supplying cold and hot water. As well, high-rise residential buildings bring on discomfortable use and unexpected conditions on account of faucet outlet pressure rise and the difference of water supply pressure between top floor and bottom floor. Thus, the purpose of this study is to research on using conditions of cold and hot water supply system through survey and field measurement in high-rise residential buildings and to analyze problems.

  • PDF

The Impact of Bake-Out Method on the Reduction of Pollutant Concentration in New Apartments (Bake-Out에 의한 신축 아파트의 실내 오염물질농도 저감효과 평가)

  • Pang Seung-Ki;Park Byung-Yoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.335-343
    • /
    • 2006
  • Indoor air pollution has been significantly aggravated due to hazardous pollutants emitted from petrochemical finishing materials in new apartments. Pollutants emitted into indoor environment have significant effects on the health of occupants, causing undesirable symptoms related to sick building syndrome such as headache, dizziness, difficulty in concentration, etc. Therefore, this paper attempted to investigate the reduction effect of bake out on VOCs emission in new apartments. Experiments were carried out in three households, one of which was naturally ventilated. The naturally ventilated showed the lowest indoor pollutant concentration and also showed the highest reduction rate by the use of bake out. The most desirable result was observed when the household was naturally ventilated after bake out. More detailed experiments are expected to be carried out afterwards on the prediction of reduction rate of each pollutant.

Impact of Indoor Air Quality on the Eye Conditions of Occupants in Newly-built University Buildings (새 학교 건물 내 실내공기질이 재실자의 안구에 미치는 영향)

  • Kim, Woo-Jae;Kim, Sun-Duk;Kim, Hyojin;Kim, Ho-Hyun;Lee, Cheol-Min;Kim, Yoon-Shin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.201-207
    • /
    • 2011
  • Purpose: This study was to find out the influence on eyes of indoor air quality in college students taking course, such as Sick-building syndrome symptoms and effects on the eye in new-built university buildings. Methods: We selected a new building in a university located in Metro Seoul and college students in a department for the study. The number of total participants was 33, to whom questionnaire surveys were conducted in advance to check individual traits (gender, age, whether to smoke, whether to wear contact lenses, or whether to drink). The first questionnaire surveys and checking of ocular symptoms to first indoor hazardous materials were conducted in October and two months later the second surveys and checking were carried out in December. The indoor air quality was measured when conducting the first questionnaire surveys and the second questionnaire surveys; especially measurements of gaseous materials such as aldehydes and VOCs in the indoor air were conducted. Results: Indoor air quality of the new building was as follows: formaldehyde level was 22.90 ${\mu}g/m^3$ in the first measurement and 16.79 ${\mu}g/m^3$ in the second measurement. In addition, most materials showed higher value in the first measurement. The level of TVOC was statistically significant (p<0.05) decreased on 448.54 ${\mu}g/m^3$ in the first and 62.55 ${\mu}g/m^3$ in the second. In clinical assessments to check ocular symptoms caused by eye irritations, dry eye syndrome was found in the first and second exposures. When comparing the first and second assessments, dry eyes deteriorated in the morning of the second attempt compared to the first one. Conclusions: In the survey of ocular symptoms and the measurement of indoor air quality, the level of formaldehyde was measured higher in the second attempt than the first; thus, it was confirmed the influence of indoor air quality in a new building upon ocular symptoms of occupants.

The Effects of Volatile Organic Compounds on Apoptosis of Human Neutrophils and Eosinophils

  • Yang, Eun-Ju;Kim, In-Sik
    • Biomedical Science Letters
    • /
    • v.16 no.2
    • /
    • pp.123-126
    • /
    • 2010
  • Volatile organic compounds are commonly off gassed from various building materials and can induce sick building syndrome. Volatile organic compounds such as formaldehyde, xylene and toluene are known as toxic agents in immune cells. Human leukocytes, particularly, neutrophils and eosinophils play important roles in the regulation of immune responses. In this study, we investigated the toxic effects of formaldehyde, ortho-xylene (o-xylene), para-xylene (p-xylene) and toluene on the apoptosis of neutrophils and eosinophils isolated from the blood of healthy donors. Formaldehyde increased the constitutive apoptosis of neutrophils and eosinophils. o-xylene, p-xylene and toluene increased the spontaneous apoptosis of eosinophils, but not that of neutrophils. Formaldehyde increased the protein level of IL-8 in neutrophils and eosinophils, and suppressed the MCP-1 expression in neutrophils. The release of IL-6 from neutrophils was diminished by volatile organic compounds used in this study. In conclusion, formaldehyde, xylene and toluene elevate the apoptosis of neutrophils and eosinophils, and regulate the release of cytokine and chemokine in neutrophils and eosinophils. These results indicate that formaldehyde, xylene and toluene have a cytotoxicity in human neutrophils and eosinophils and may damage the modulation of immune responses.

Usability and Strength Characteristics of Loess(Hwangtoh) Finishing Material by Different Ratios of Ingredients (황토 마감재의 배합비에 따른 압축강도 특성과 사용성 평가)

  • Lee, Shin-Ho;Yoon, Seong-Soo;Song, Kyo;Song, Chang-Seob;Han, Chung-Su
    • Journal of Korean Society of Rural Planning
    • /
    • v.11 no.3 s.28
    • /
    • pp.53-57
    • /
    • 2005
  • Up to recently building are constructed focusing on the convenience of residential condition. However, environmental-friendly materials is required for construction as people are spending more time inside buildings and causes of many problems like sick-building syndrome are known due to the noxious gases and polluted air originated from construction materials. Although loess(hwangtoh) is an environmental-friendly material, it has limitations in compressive strength far a construction material. The purpose of this study is to suggest the optimal ratio of loess(hwangtoh) mortar by tests of compressive strength comparing with standard strength of floor finishing mortar and evaluate the usability of loess(hwangtoh) mortar for floor finishing material through an impact test, a cracking test and a abrasion test. Based on the results of this study, 86% of loess(hwangtoh) and 14% of inorganic binder is suggested for the optimal mixture ratio of loess(hwangtoh) mortar. Moreover, the characteristics of loess(hwangtoh) is suitable for floor finishing material in impact, crack, abrasion.