• Title/Summary/Keyword: Si-adhesive

Search Result 147, Processing Time 0.033 seconds

Microstructure and Characteristics of SiCp/Al-4.5wt%Cu-1wt%Mg Composites by Pressurized Continuous Compo-Casting (가압연속주조법에 의한 SiCp/Al 합금기 복합재료의 조직 및 특성)

  • Lee, Hak-Joo;Hong, Chun-Pyo
    • Journal of Korea Foundry Society
    • /
    • v.11 no.1
    • /
    • pp.71-78
    • /
    • 1991
  • Microstructure and characteristics of the SiCp/Al-4.5wt%Cu-1wt%Mg composites fabricated by the combination of the compocasting and the pressurized continuous casting process, which is one of the processes to decrease the limitations of the size, and shops of the products, are investigated. The main results are as follows: 1) the SiCp/Al alloy matrix composites can be made continuously 2) as the amount of SiCp addition increases; (1) the degree of directional solidification of matrix structure decreases, and that of SiCp dispersion improves, (2) wear resistance improves, and especially these composites show the excellent wear resistance under the high sliding speed and high final load condition, (3) wear mechanism of these composites is changed from adhesive wear into abrasive wear, and the tendency of that becomes outstanding with increasing sliding speed.

  • PDF

THE EFFECT OF SURFACE TREATMENTS ON THE SHEAR BOND STRENGTH OF REPAIRED COMPOSITES (광중합형 복합레진 수리시 표면처리가 전단결합강도에 미치는 영향)

  • Moon, Jang-Won;Lee, Kwang-Won;Park, Soo-Joung
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.156-165
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of surface treatments on the shear bond strength between new and old composites. Circular cavities prepared on the center of acrylic resin mold and the prepared cavities were filled with composite resin. They randomly assigned into control group and 8 groups according to the difference in surface treatments of old composites; Control group: no surface treatment, Group 1: surface treated with #120 SiC paper & bonding agent, Group 2: surface treated with #400 SiC paper & bonding agent, Group 3: surface treated with #120 SiC paper, 32% $H_3PO_4$ & bonding agent, Group 4: surface treated with #400 SiC paper, 32% $H_3PO_4$ & bonding agent, Group 5: surface treated with #120 SiC paper, primer & bonding agent, Group 6: surface treated with #400 SiC paper, primer & bonding agent, Group 7: surface treated with #120 SiC paper, 32% $H_3PO_4$, primer & bonding agent, Group 8: surface treated with #400 SiC paper, 32% $H_3PO_4$, primer & bonding agent. New composites were applicated on the old composites of experimental groups. The shear bond strengths for the experimental specimen were measured and the results were analyzed by using one way ANOVA. The observations of surface morphology after SiC paper roughening and debonded surface morphology after shear bond strength test were done by SEM. The results were as follows; 1. Shear bond strengths for specimens roughened with #120 SiC paper matching with the particle size of coarse diamond bur were significantly higher than those for the specimens with #400 SiC paper(P<0.05). By SEM, the surface of the specimens roughened with #120 SiC paper was more irregular than the specimens with #400 SiC paper. 2. Shear bond strengths for specimens treated with 32% $H_3PO_4$ etchant, primer, bonding resin were significantly higher than those for specimens treated with 32% $H_3PO_4$ and bonding resin(P<0.05). 3. Shear bond strengths for the specimens treated with 32% $H_3PO_4$ etchant and bonding resin were significantly higher than those for specimens treated with only bonding resin(P<0.05). There was no remarkable change of surface morphology after 32% $H_3PO_4$ etching. 4. It was possible to observe mixed fracture patterns (the cohesive fracture of old composite and the adhesive fracture between old and new composite) in the specimens roughened with #120 SiC paper, but almost adhesive fracture in the specimens roughened with #400 SiC paper.

  • PDF

Study of Characteristics for Red Adhesive in Traditional Gold Thread (전통 편금사에 사용된 붉은 접착제 특성 연구)

  • Kim, Ji Eun;Yu, Ji A;Han, Ye Bin;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.32 no.1
    • /
    • pp.43-49
    • /
    • 2016
  • Gold threads mean thread made by metal, it is composed various material to gold leaf, adhesive and media. The making technique and using materials of Gold threads are different from region, it can be used to distinguish country of origin. So this study finds characteristics and making techniques for flat gold threads of relics. Standard samples are made of animal glue, lacquer, red lacquer and etc. This materials are based on the scientific investigation of cultural gold threads properties. Then traditional techniques were estimated by comparison and analysis of actual cultural properties and standard samples. As a result of investigating cultural properties, it is similar to the standard sample which are mixed with red soil additives. After analysis of SEM-EDS, it is detected to Al, Si, Fe. So it is to the conclusion that traditional gold thread is made of adhesive mixed with red soil to improve gold color better. And this ways are similar with china that uses animal glue and red soil to adhesive and different from japan that uses lacquer to adhesive. Through this study, it will be used to data and reference for reappearance and making techniques of traditional gold threads.

Shear bond strength between universal adhesives with various pH and dual-cured resin cements (다양한 pH를 가지는 Universal adhesives와 이원 중합 레진 세멘트 간의 전단결합강도)

  • Kwon, Sung-Joo;Park, Jeong-Kil;Son, Sung-Ae
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.301-310
    • /
    • 2018
  • The purpose of this study is to evaluate the compatibility of universal adhesives with two dual-cured resin cements. Eighty human molars were divided into eight groups. Tooth was embedded in self-curing acrylic resin and sectioned horizontally to exposure dentine surface. After polishing with 600-grit SiC paper, adhesives were applied. All-Bond Universal (Bisco), G-premio bond (GC), Scotch-bond universal (3M ESPE), Scotch-bond Multipurpose (3M ESPE) were used in this study. Calibra (Dentsply) as a conventional dual-curing resin cement and RelyX Ultimate (3M ESPE) as an amine free resin cement were used. The adhesives and the cements were applied according to the manufacturer's instructions. Final specimens were cylinder (diameter 2mm, height 3mm) shape. After storing in distilled water at $37^{\circ}C$ for 7 days the shear bond strength (SBS) test was performed. There was no significant difference in shear bond strength between the adhesives when RelyX Ultimate was used (p>0.05). However, when Calibra used with Scotch-bond Multipurpose and All-Bond Universal were used, statistically higher SBS was observed, as compared to the groups which Calibra cements with G-premio bond and Scotch-bond universal adhesive (p<0.05) were used. Within the limitations of this study, RelyX Ultimate resin cement was compatible with universal adhesives of various pH. All-Bond Universal adhesive was compatible with a resin cement containing the tertiary amine.

Wear Characteristics of Atomic Force Microscope Tip

  • Chung, Koo-Hyun;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.2
    • /
    • pp.39-45
    • /
    • 2004
  • Atomic Force Microscope (AFM) has been widely used in micro/nano-scale studies and applications for the last few decades. In this work, wear characteristics of silicon-based AFM tip was investigated. AFM tip shape was observed using a high resolution SEM and the wear coefficient was approximately calculated based on Archard's wear equation. It was shown that the wear coefficient of Si and ${Si}_3$$N_4$ tips were in the range of ${10}^{-1}$~${10}^{-3}$and ${10}^{-3}$~${10}^{-4}$, respectively. Also, the effect of relative humidity and sliding distance on adhesion-induced tip wear was investigated. It was found that the tip wear has more severe for harder counter surface materials. Finally, the probable wear mechanism was analyzed from the adhesive and abrasive interaction point of view.

Tribological Behaviors Against Counterpart Materials of Ti-Si-N Coating Layers Prepared by a Hybrid Coating System (하이브리드 코팅시스템에 의해 제조된 Ti-Si-N 코팅막의 상대재에 대한 마모거동 연구)

  • 박옥남;박종현;윤석영;권식철;김광호
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.2
    • /
    • pp.116-121
    • /
    • 2003
  • Ti-Si-N coating layers were deposited onto WC-Co substrates by a hybrid system of arc ion plating (AIP) and sputtering techniques. The tribological behaviors of Ti-Si-N coating layers with various Si contents were investigated by the dry sliding wear experiments, which were conducted at three different sliding speeds, 0.1, 0.3, 0.5 m/s, against the steel and alumina balls. In the case of steel ball, the average friction coefficient slightly decreased with increasing the sliding speed regardless of Si content due to adhesive wear behavior between coating layer and steel ball. At constant sliding speed, the average friction coefficient decreased with increase of Si content. On the contrary, in the case of alumina ball, the average friction coefficient increased with increasing the sliding speed regardless of Si content, indicating that the abrasive wear behavior was more dominant when the coating layers slide against alumina ball. Through these experimental results, it was found that the tribological behaviors of Ti-Si-N coating layers were effected by factors such as Si content, sliding speed, and kinds of counterpart materials rather than the hardness of coating layer.

Characteristics of Adhesive Disks in Parthenocissus tricuspidata during Attachment (착생에 따른 담쟁이덩굴 흡착근의 부착 특성)

  • Lee, Myung-Hui;Kim, In-Sun
    • Applied Microscopy
    • /
    • v.41 no.2
    • /
    • pp.139-145
    • /
    • 2011
  • Parthenocissus tricuspidata is an epiphyte that lacks a main axial stem, but develops adhesive disks along the stem for climbing support. In this study, scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) were utilized to examine the brick wall surface and the adhesive disks of P. tricuspidata that attached to the surface successfully. The study was mainly focused the outermost layers of both structures before and after adhesion to find out whether there has been some structural and/or physical interactions between the two. The adhesive disks adhered firmly to the brick wall by secreting adhesive materials that help them for a tight attachment to the surface. The rough wall surface appeared facilitating better attachment of the adhesive disks by infiltrating the materials into those spaces leading to some degree of interactions at the interface. EDS analysis on the outermost layers of the adhesive disks that were separated from the substrates was also consistent with the SEM data on the interaction between the adhesive disks and the substrate surface. EDS analysis of the brick wall surface and the adhesive disks demonstrated similar elements of O, Si, Fe, Al, K, Mg, and Na in their components.

Adhesion and Diffusion Barrier Properties of $TaN_x$ Films between Cu and $SiO_2$ (Cu 박막과 $SiO_2$ 절연막사이의 $TaN_x$ 박막의 접착 및 확산방지 특성)

  • Kim, Yong-Chul;Lee, Do-Seon;Lee, Won-Jong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.3
    • /
    • pp.19-24
    • /
    • 2009
  • Formation of an adhesion/barrier layer and a seed layer by sputtering techniques followed by electroplating has been one of the most widely used methods for the filling of through-Si via (TSV) with high aspect ratio for 3-D packaging. In this research, the adhesion and diffusion-barrier properties of the $TaN_x$ film deposited by reactive sputtering were investigated. The adhesion strength between Cu film and $SiO_2$/Si substrate was quantitatively measured by $180^{\circ}$ peel test and topple test as a function of the composition of the adhesive $TaN_x$ film. As the nitrogen content increased in the adhesive $TaN_x$ film, the adhesion strength between Cu and $SiO_2$/Si substrate increased, which was attributed to the increased formation of interfacial compound layer with the nitrogen flow rate. We also examined the diffusion-barrier properties of the $TaN_x$ films against Cu diffusion and found that it was improved with increasing nitrogen content in the $TaN_x$ film up to N/Ta ratio of 1.4.

  • PDF

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.