• Title/Summary/Keyword: Shunt active filter

Search Result 105, Processing Time 0.025 seconds

Three-Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory (순시 무효전력 이론 기반의 능동전력필터 기능을 가지는 삼상 지-소스 정류기)

  • ANVAR, IBADULLAEV;Hong, Seung-Pyo;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.365-366
    • /
    • 2015
  • Shunt active power filter is a complete current source which can provide an effective and adjustable solution for elimination of harmonic currents in power system. Its performance depends on strategy employed in reference current generation, control technique and topology of converter used in the design.[1-2]. In this paper Three Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory is described. Thanking to the theory power factor and THD value are significantly improved. Experiment results and conclusions are presented.

  • PDF

Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Series Active Filter (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식)

  • Ji, Jun-Keun;Kim, Jang-Hwan;Sul, Seung-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.538-546
    • /
    • 2007
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently. In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state. Therefore the experimental results to prototype UPS system having power rating of 60kVA is shown to prove the verification of voltage control strategy.

Voltage %THD Improvement of Distribution System by Shunt Z-Source Active Filters (병렬형 Z-소스 능동필터에 의한 배전계통의 전압 %THD 개선)

  • Oh, Seung-Yeol;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.86-89
    • /
    • 2007
  • 본 연구에서는 배전계통의 전압 고조파 확산에 따른 전압 %THD (%Total Harmonic Distortion)를 개선하기 위한 Z-소스 능동필터(Z-AFU : Z-Source Active Filter Unit)를 제시하였다. 버스(Bus)의 전압 고조파는 60Hz 버터워쓰 저역통과필터(LPF)에 의하여 검출하였다. 제안된 시스템의 보상전원으로는 고분자 전해질 연료전지(PEMFC)를 사용하였다. 제안된 시스템의 타당성을 확인하기 위하여 PSIM 시뮬레이션을 수행하였으며, 전압 고조파 확산 억제에 따른 배전계통 전압의 %THD를 개선 할 수 있었다.

  • PDF

A Study on the capacity of shunt type active power filter with a thyristor converter load (싸이리스터 컨버터부하를 가지는 병렬형 능동전력필터 용량에 관한 연구)

  • Park, No-Joong;Joeng, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2470-2474
    • /
    • 1999
  • The main drawback of parallel type active power filters (APFs) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement for harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current, while maintaining the filtering performance with an acceptable total harmonic current level. the minimum capacity requirement of APF with current limiting is evaluated as a function of the firing angle of thyristor converter and short circuit ratio(SCR).

  • PDF

A design for a robust active power filter in unbalanced and distortion source voltages in three-phase four-wire systems (전원전압의 불평형 및 왜곡에 강인한 3상 4선식 전력용 능동 필터의 설계)

  • Min J.K.;Choi J.H.;Kim H.S.;Kim K.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.729-733
    • /
    • 2003
  • This paper proposed a novel current control strategy on active power filters using p-q-r instantaneous power theory which can compensate the line current harmonics and the neutral line current in unbalanced and/or distorted source conditions in three-phase four-wire systems. The proposed current control method is based on a sinusoidal PWM for fully-digital implementation which was compared with a hysteresis PWM. Simulation results showed good performance of the proposed current control strategy on shunt type APFs.

  • PDF

Series-Active and Shunt-Pasive Type Power Filter Compensating Harmonic Currents and Unbalanced Voltages of Source (직렬형 능동필터와 수동형 병렬필터를 이용한 전원불평형 및 고조파 전류 보상)

  • Lee G-Myoung;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.565-568
    • /
    • 2001
  • A novel control scheme compensating for source voltage unbalance and harmonic current for series active power filters is proposed, where the references for voltage unbalance and current harmonic and phase angle is derived from the positive sequence component of the source voltage obtained simply through digital all-pass filters, which makes the whole control algorithm simpler than other methods using p-q theory. In addition, the harmonic component of source current is compensated by harmonic component of load voltage and therefore fundamental component of source current is considered as separated terms for the control issue. The validity of the proposed scheme has been verified by experimental results.

  • PDF

Direct Harmonic Voltage Control Strategy of Shunt Active Power Filters Suitable for Microgrid Applications

  • Munir, Hafiz Mudassir;Zou, Jianxiao;Xie, Chuan;Li, Kay;Younas, Talha;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.265-277
    • /
    • 2019
  • The application of shunt active power filters (S-APFs) is considered to be the most popular approach for harmonic compensation due to its high simplicity, ease of installation and efficient control. Its functionality mainly depends upon the rapidness and precision of its internally built control algorithms. A S-APF is generally operated in the current controlled mode (CCM) with the detection of harmonic load current. Its operation may not be appropriate for the distributed power generation system (DPGS) due to the wide dispersion of nonlinear loads. Despite the fact that the voltage detection based resistive-APF (R-APF) appears to be more appropriate for use in the DPGS, the R-APF experiences poor performance in terms of mitigating harmonics and parameter tuning. Therefore, this paper introduces a direct harmonic voltage detection based control approach for the S-APF that does not need a remote harmonic load current since it only requires a local point of common coupling (PCC) voltage for the detection of harmonics. The complete design procedure of the proposed control approach is presented. In addition, experimental results are given in detail to validate the performance and superiority of the proposed method over the conventional R-APF control. Thus, the outcomes of this study approve the predominance of the discussed strategy.

Synthesis of Active Filers Using Linear Transformation (선형변환기법을 이용한 능동여파기의 구성에 관한 연구)

  • 이태원;조용현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.2
    • /
    • pp.41-51
    • /
    • 1983
  • An efficient method for the desist of active filters from doubly terminated lossless ladder type passive filters is presented. This technique is based on the linear transformation of network variables from the voltage-current domain to a new domain for the active realization of the passive networks. The method developed herein applies the linear transformation to a ladder building block which contains both a shunt and a series reactive arm, resulting in the minimization of the number of operational amplifiers required for the active realization. The validity and efficiency of this method are verified by the design of the 8th-order Chebyshev low-pass filter followed by the measurement of its frequency characteristics which fairly agree with the theoretic ones.

  • PDF

A Study on PV Power Generation System Adding the Function of Shunt Active Filler Using DSP (DSP를 이용한 엑티브 필터 기능 추가형 태양광발전시스템의 운전특성에 관한 연구)

  • Seo, Hyo-Ryong;Park, Young-Gil;Kim, Jong-Hyun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1169-1170
    • /
    • 2006
  • Grid connected PV(Photovoltic) generation systems are becoming and actual and general. The power output of PV system is directly affected by the weather conditions. And when AC power supply is needed, power conversion by an inverter and a MPPT control are necessary. The PV power generation system can be treated to a harmonics source for the power distribution system. So, the PV system combined the function of active filter system can be useful applied in power distribution system. AF(Active Filters) intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer. With the test analysis of the proposed control strategy of PV-AF system, the outcome of the test shows the stability and effectiveness of the proposed PV-AF system. The various capability of AF has been proved in previous research and usage. In this paper, authors present a DSP controlled PV-AF system for power conditioning in three-phase industrial or commercial power systems and verify it through experimental results.

  • PDF

An Improved One Cycle Control for Active Power Filters under Non-Ideal Voltage Conditions

  • Wang, Lei;Ren, Chunguang;Yang, Yu;Han, Xiaoqing;Wang, Peng
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2350-2358
    • /
    • 2016
  • The one cycle control (OCC) scheme for active power filters (APFs) has shown excellent harmonic suppression and implementation simplicity. However, its real world application is limited because the non-ideal supply voltage for APFs can influence its performance so that the source currents are still distorted after compensation. This paper proposes a modified one cycle control (MOCC) scheme to improve the performance of three-phase shunt APFs under non-ideal supply voltage conditions. In this paper a detailed mathematical derivation has been presented and the key control law of the MOCC has been developed for adaption to the non-ideal supply voltages, following the control philosophy of simplicity. A relatively simple sequence filter is introduced to extract the harmonic components of supply voltages. The modified scheme can be easily implemented. The proposed control strategy has excellent performance and a 5kVA APF hardware platform has been implemented to validate the feasibility and performance of the proposed strategy.