• 제목/요약/키워드: Shunt Reactor

검색결과 44건 처리시간 0.025초

발전기 운전조건을 고려한 조상설비계획 (Shunt Compensator Planning considering generator's operating condition)

  • 이철휴;이상호;박종근;이송근;김홍균;이석진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1496-1498
    • /
    • 1999
  • The line charging is becoming larger due to the expansion of underground cable and extra high voltage lines. It causes reactive power surplus at light load condition which may force generators to operate reluctantly in the under excited mode. This paper proposes the pratical criteria and methodolgy for the shunt reactor planning while suppressing generator's under excited operation.

  • PDF

765 kV 송전선로의 345 kV 운전에 따른 계통 해석 (The analysis result of temporary operation of 765 kV transmission line as 345 kV rating)

  • 우정욱;심응보;강연욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1647-1649
    • /
    • 1998
  • This paper describes the power frequency voltage and its countermeasure when a 765 kV transmission line is directly connected to a 345 kV line and operated at 345 kV voltage. The summary of this result is as follows : The western route of 765 kV transmission line doesn't need any countermeasure to reduce the power frequency voltage at the receiving end. The eastern route of 765 kV transmission needs 100 Mvar(3 phase) capacity of shunt reactor at the receiving end to reduce the power frequency voltage. The use of shunt reactors in the 765 kV transmission lines has unexpected problems, one of which is induction of high voltages on a de-energized circuit of two parallel lines. This paper examined the problem of resonance on two parallel transmission circuits in one routes.

  • PDF

션트리액터에 의한 박막형 초전도 한류기의 퀜치 특성 (Quench Properties of a Superconducting Fault Current Limiter Using YBCO Films by Shunt Reactors)

  • 남긍현;조용선;이나영;박형민;최효상;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1219-1221
    • /
    • 2005
  • We improved quench properties of a superconducting fault current limiter(SFCL) components based on YBCO thin films. This consists of three components with nearly identical properties and one with slightly difference properties. The units were connected in series and first of parallel to increase the current and voltage ratings. It have caused significantly imbalanced power distribution. The imbalance remarkably improved by connecting a shunt reactor to the SFCL component in parallel.

  • PDF

분리형과 일체형 리액터에 따른 매트릭스형 초전도 한류기의 외부자장 의존성 연구 (Dependence of External Magnetic Field in the Matrix-Type SFCL with the Separated or the Integrated Reactors)

  • 조용선;최효상;정병익;고성필
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.880-884
    • /
    • 2011
  • The matrix-type superconducting fault current limiter (MSFCL) consists of the trigger and current-limiting parts. The trigger part with reactors connected in parallel improves the quenching characteristics by applying the external magnetic field into the superconducting units. The current-limiting part with superconducting units connected in parallel and shunt reactors connected in series limit the fault current when the fault occurs. We developed the integrated reactor with the trigger and the current-limiting parts to apply high external magnetic field into the superconducting units. This was composed of a superconducting unit for the trigger part and two superconducting units for the current-limiting parts. We confirmed that the external magnetic field generated in the MSFCL with an integrated reactor was larger than that of the MSFCL with the separated reactors. So the differences of voltages generated between superconducting units were decreased in the difference according to the increment of the applied voltage. The whole magnitude of the SFCL was reduced because the volume of an integrated reactor could be reduced by one-third than that of the separated reactors. We confirmed that the critical behavior between the superconducting units in the MSFCL with an integrated reactor was more improved than that of the MSFCL with the separated reactors.

전력용(電力用) 변압기(變壓器) 고장전류(故障電流) 감소(減少)를 위(爲)한 중성점(中性点) 리액터 적용(適用) 연구(硏究) (The Application of Neutral Reactors to Limit Through fault Duty on Substation Transformer.)

  • 장종근;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.210-213
    • /
    • 1990
  • This paper presents the countermeasure to present the main transformer of distribution substation from deteriorating and failing due to repeated magnetic force of the transformer winding by ground fault current in 22.9kV multi grounded distribution system. The Winding strength to the short circuit current is designed to be endurable to the stress of over current. But this design is related to the manufactures. In this paper we examine the application of shunt reactor to the neutral point of the low side of the transformer to reduce fault current due to the fault in the distribution lines we have analysed the fault characteristics of the system and calculated the optimum ohmic values of the neutral reactor.

  • PDF

AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식 (Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Series Active Filter)

  • 지준근;김장환;설승기
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.538-546
    • /
    • 2007
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently. In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state. Therefore the experimental results to prototype UPS system having power rating of 60kVA is shown to prove the verification of voltage control strategy.

광역계통 전압/무효전력 관리를 위한 전압관리시스템의 개발 및 현장설치 (Development and Installation of Voltage Management System for Voltage and Reactive Power Control of Wide Area System)

  • 남수철;신정훈;백승묵;이재걸;문승필;김태균
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1540-1548
    • /
    • 2010
  • KEPCO proposes enhanced voltage management system that is a coordinate voltage control system between the hierarchical voltage control system and the slow voltage control system. It has been installing in Jeju island. VMS consists of a master controller, CVC (Continuous Voltage Controller) and DVC (Discrete Voltage Controller). CVC consists of main controller, FDMU (Field Data Measurement Unit) and several RPDs (Reactive Power Dispatcher). CVC has a control scheme with AVRs of generator to maintain the voltage of a pilot bus in a power system, DVC has a control scheme with static reactive power sources, like a shunt capacitor, a shunt reactor, ULTC and so on, to maintain the reactive power reserve of a power system and a master controller is executed to recover reactive power margin of a power system through coordinated control between CVC and DVC.

하이브리드 타입 커패시터 뱅크를 이용한 공급신뢰도 및 전력품질 개선 방안 연구 (A Study on the Service Reliability and Power Quality Improvement Using Hybrid Type Capacitor Bank)

  • 이한상;윤동희
    • 전기전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.313-319
    • /
    • 2014
  • 전력계통운영의 목표는 전력시스템의 안정성과 신뢰성을 유지하여 원활한 전력을 공급하는 것이다. 안정적인 전력 공급을 위하여 무효전력과 모선 전압에 대한 고려를 해야 하는데, 모선의 전압을 일정 범위 이내로 유지하기 위하여 커패시터 뱅크를 비롯한 다양한 방안이 사용되고 있다. 본 논문에서는 계통 안정도와 전력공급 신뢰도를 상시키기 위한 하이브리드 타입의 커패시터 뱅크 설계 과정에 대하여 기술하였다. 설계 과정에는 커패시터 뱅크의 용량 산정, 리액터 타입 결정 및 리액터 용량 산정과정이 포함된다. 기존의 커패시터 뱅크의 설계과정과 같이 정상상태 Q-V 해석이나 상정사고 분석과 같은 방법을 통하여 무효전력 마진을 계산하여 저전압이 발생하는 모선에 무효전력 보상량을 산정한다. 그리고 고조파 실측을 통해 산출된 개별 고조파의 성분 크기를 기반으로 직렬 리액터의 크기를 산정하는 방식으로 설계과정을 제안하였다. 논문에서는 제안된 방법을 통하여 고조파의 크기가 감소함을 증명하였으며, 특히 5차와 7차 고조파의 저감에 효율적임을 보여주었다.

Coordinated Voltage-Reactive Power Control Schemes Based on PMU Measurement at Automated Substations

  • Choi, Yun-Hyuk;Kang, Sang-Gyun;Lee, Byongjun
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1400-1407
    • /
    • 2015
  • This paper deals with methodology to control an automatic substation system. The control system can predict the power system condition by a voltage stability index (VSI). The strategies in this paper is called as Voltage-Reactive Power Control (VRPC), which regulates an abnormal voltage of a target substation by using coordination between tap changers and shunt capacitor/reactor. This method is efficient for better voltage profile. The monitoring substation includes whole of substations around the contingency event. The control quantities of the monitoring substations are decided by the calculation of the VSI, called as a Z-index. Case studies with BC Hydro-Quebec system are presented to illustrate this approach using real-time simulator.

IEC61850 프로토콜을 이용한 분로리액터 보호용 IED에 관한 연구 (A Study on the Protection IED for Shunt Reactor Using IEC 61850 Protocol)

  • 안용호;송인준;한정열;구춘서;조용익;구성완;오성준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.131-133
    • /
    • 2008
  • 최근 전력계통 분야에서는 IEC에서 제정한 변전소 자동화용 국제 규격 프로토콜인 IEC 61850을 적용한 시스템의 도입 및 적용이 활발하게 이루어지고 있다. 이러한 추세에 맞추어 변전소 내 많은 전력기기들의 IEC 61850 프로토콜을 탑재가 요구되고 있으며, 본 연구에서는 변전소 내 조상설비 중 IEC 61850 프로토콜을 적용한 분로리액터 보호용 IED의 설계, 제작, 시험을 통하여 변전자동화 가능성을 확인하였다.

  • PDF