• 제목/요약/키워드: Shunt Active Filter

검색결과 105건 처리시간 0.023초

순시 무효전력 이론 기반의 능동전력필터 기능을 가지는 삼상 지-소스 정류기 (Three-Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory)

  • 안바르;홍승표;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.365-366
    • /
    • 2015
  • Shunt active power filter is a complete current source which can provide an effective and adjustable solution for elimination of harmonic currents in power system. Its performance depends on strategy employed in reference current generation, control technique and topology of converter used in the design.[1-2]. In this paper Three Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory is described. Thanking to the theory power factor and THD value are significantly improved. Experiment results and conclusions are presented.

  • PDF

AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식 (Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Series Active Filter)

  • 지준근;김장환;설승기
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.538-546
    • /
    • 2007
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently. In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state. Therefore the experimental results to prototype UPS system having power rating of 60kVA is shown to prove the verification of voltage control strategy.

병렬형 Z-소스 능동필터에 의한 배전계통의 전압 %THD 개선 (Voltage %THD Improvement of Distribution System by Shunt Z-Source Active Filters)

  • 오승열;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.86-89
    • /
    • 2007
  • 본 연구에서는 배전계통의 전압 고조파 확산에 따른 전압 %THD (%Total Harmonic Distortion)를 개선하기 위한 Z-소스 능동필터(Z-AFU : Z-Source Active Filter Unit)를 제시하였다. 버스(Bus)의 전압 고조파는 60Hz 버터워쓰 저역통과필터(LPF)에 의하여 검출하였다. 제안된 시스템의 보상전원으로는 고분자 전해질 연료전지(PEMFC)를 사용하였다. 제안된 시스템의 타당성을 확인하기 위하여 PSIM 시뮬레이션을 수행하였으며, 전압 고조파 확산 억제에 따른 배전계통 전압의 %THD를 개선 할 수 있었다.

  • PDF

싸이리스터 컨버터부하를 가지는 병렬형 능동전력필터 용량에 관한 연구 (A Study on the capacity of shunt type active power filter with a thyristor converter load)

  • 박노중;정숭기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2470-2474
    • /
    • 1999
  • The main drawback of parallel type active power filters (APFs) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement for harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current, while maintaining the filtering performance with an acceptable total harmonic current level. the minimum capacity requirement of APF with current limiting is evaluated as a function of the firing angle of thyristor converter and short circuit ratio(SCR).

  • PDF

전원전압의 불평형 및 왜곡에 강인한 3상 4선식 전력용 능동 필터의 설계 (A design for a robust active power filter in unbalanced and distortion source voltages in three-phase four-wire systems)

  • 민준기;최재호;김효성;김경환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.729-733
    • /
    • 2003
  • This paper proposed a novel current control strategy on active power filters using p-q-r instantaneous power theory which can compensate the line current harmonics and the neutral line current in unbalanced and/or distorted source conditions in three-phase four-wire systems. The proposed current control method is based on a sinusoidal PWM for fully-digital implementation which was compared with a hysteresis PWM. Simulation results showed good performance of the proposed current control strategy on shunt type APFs.

  • PDF

직렬형 능동필터와 수동형 병렬필터를 이용한 전원불평형 및 고조파 전류 보상 (Series-Active and Shunt-Pasive Type Power Filter Compensating Harmonic Currents and Unbalanced Voltages of Source)

  • 이지명;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.565-568
    • /
    • 2001
  • A novel control scheme compensating for source voltage unbalance and harmonic current for series active power filters is proposed, where the references for voltage unbalance and current harmonic and phase angle is derived from the positive sequence component of the source voltage obtained simply through digital all-pass filters, which makes the whole control algorithm simpler than other methods using p-q theory. In addition, the harmonic component of source current is compensated by harmonic component of load voltage and therefore fundamental component of source current is considered as separated terms for the control issue. The validity of the proposed scheme has been verified by experimental results.

  • PDF

Direct Harmonic Voltage Control Strategy of Shunt Active Power Filters Suitable for Microgrid Applications

  • Munir, Hafiz Mudassir;Zou, Jianxiao;Xie, Chuan;Li, Kay;Younas, Talha;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.265-277
    • /
    • 2019
  • The application of shunt active power filters (S-APFs) is considered to be the most popular approach for harmonic compensation due to its high simplicity, ease of installation and efficient control. Its functionality mainly depends upon the rapidness and precision of its internally built control algorithms. A S-APF is generally operated in the current controlled mode (CCM) with the detection of harmonic load current. Its operation may not be appropriate for the distributed power generation system (DPGS) due to the wide dispersion of nonlinear loads. Despite the fact that the voltage detection based resistive-APF (R-APF) appears to be more appropriate for use in the DPGS, the R-APF experiences poor performance in terms of mitigating harmonics and parameter tuning. Therefore, this paper introduces a direct harmonic voltage detection based control approach for the S-APF that does not need a remote harmonic load current since it only requires a local point of common coupling (PCC) voltage for the detection of harmonics. The complete design procedure of the proposed control approach is presented. In addition, experimental results are given in detail to validate the performance and superiority of the proposed method over the conventional R-APF control. Thus, the outcomes of this study approve the predominance of the discussed strategy.

선형변환기법을 이용한 능동여파기의 구성에 관한 연구 (Synthesis of Active Filers Using Linear Transformation)

  • 이태원;조용현
    • 대한전자공학회논문지
    • /
    • 제20권2호
    • /
    • pp.41-51
    • /
    • 1983
  • 선형변환기법을 이용하여 사다리형태의 수동여파회로를 능동화하는데 있어서 새로운 방식을 제시하였다. 전압과 전류영역으로 나타내는 회로망변수를 선형변환메이트릭스의 사용으로 새로운 영역의 변수로 바꾸어서 회로를 능동화하는 과정에서 종전의 방법은 개개의 리액턴스소자에 대해서 선형변환을 적용하는데 비하여 본연구에서는 병렬과 직렬의 두개의 리액턴스소자에 동시에 선형변환을 적용함으로써 회로능동화에 소요되는 연산증폭기의 개수를 여파기의 차수와 같도록 줄일수 있었다. 저역통과여파기의 경우. 선형변환메이트릭스를 적절하게 선택함으로써 사다리형회로의 리액턴스소자의 배치여하에 관계없이 규칙적이며 단계적인 회로능동화를 가능하게 하였다. 이 방법에 따라 5차 Chebyshev 저역통과여파회로를 능동화한 다음 이론치에 매우 근사한 주파수특성을 측정으로 얻음으로써 이 방식의 타당성을 입증하였다.

  • PDF

DSP를 이용한 엑티브 필터 기능 추가형 태양광발전시스템의 운전특성에 관한 연구 (A Study on PV Power Generation System Adding the Function of Shunt Active Filler Using DSP)

  • 서효룡;박영길;김종현;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1169-1170
    • /
    • 2006
  • Grid connected PV(Photovoltic) generation systems are becoming and actual and general. The power output of PV system is directly affected by the weather conditions. And when AC power supply is needed, power conversion by an inverter and a MPPT control are necessary. The PV power generation system can be treated to a harmonics source for the power distribution system. So, the PV system combined the function of active filter system can be useful applied in power distribution system. AF(Active Filters) intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer. With the test analysis of the proposed control strategy of PV-AF system, the outcome of the test shows the stability and effectiveness of the proposed PV-AF system. The various capability of AF has been proved in previous research and usage. In this paper, authors present a DSP controlled PV-AF system for power conditioning in three-phase industrial or commercial power systems and verify it through experimental results.

  • PDF

An Improved One Cycle Control for Active Power Filters under Non-Ideal Voltage Conditions

  • Wang, Lei;Ren, Chunguang;Yang, Yu;Han, Xiaoqing;Wang, Peng
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2350-2358
    • /
    • 2016
  • The one cycle control (OCC) scheme for active power filters (APFs) has shown excellent harmonic suppression and implementation simplicity. However, its real world application is limited because the non-ideal supply voltage for APFs can influence its performance so that the source currents are still distorted after compensation. This paper proposes a modified one cycle control (MOCC) scheme to improve the performance of three-phase shunt APFs under non-ideal supply voltage conditions. In this paper a detailed mathematical derivation has been presented and the key control law of the MOCC has been developed for adaption to the non-ideal supply voltages, following the control philosophy of simplicity. A relatively simple sequence filter is introduced to extract the harmonic components of supply voltages. The modified scheme can be easily implemented. The proposed control strategy has excellent performance and a 5kVA APF hardware platform has been implemented to validate the feasibility and performance of the proposed strategy.