Systematic Review and Meta-Analysis of Antibiotic-Impregnated Shunt Catheters on Anti-Infective Effect of Hydrocephalus Shunt

  • Zhou, Wen-xiu;Hou, Wen-bo;Zhou, Chao;Yin, Yu-xia;Lu, Shou-tao;Liu, Guang;Fang, Yi;Li, Jian-wen;Wang, Yan;Liu, Ai-hua;Zhang, Hai-jun
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권2호
    • /
    • pp.297-308
    • /
    • 2021
  • Objective : Shunt infection is a common complication while treating hydrocephalus. The antibiotic-impregnated shunt catheter (AISC) was designed to reduce shunt infection rate. A meta-analysis was conducted to study the effectiveness of AISCs in reduction of shunt infection in terms of age, follow-up time and high-risk patient population. Methods : This study reviewed literature from three databases including PubMed, EMBASE, and Cochrane Library (from 2000 to March 2019). Clinical studies from controlled trials for shunt operation were included in this analysis. A subgroup analysis was performed based on the patient's age, follow-up time and high-risk population. The fixed effect in RevMan 5.3 software (Cochrane Collaboration) was used for this meta-analysis. Results : This study included 19 controlled clinical trials including 10105 operations. The analysis demonstrated that AISC could reduce the infection rate in shunt surgery compared to standard shunt catheter (non-AISC) from 8.13% to 4.09% (odds ratio [OR], 0.48; 95% confidence interval [CI], 0.40-0.58; p=0.01; I2=46%). Subgroup analysis of different age groups showed that AISC had significant antimicrobial effects in all three groups (adult, infant, and adolescent). Follow-up time analysis showed that AISC was effective in preventing early shunt infections (within 6 months after implant). AISC is more effective in high-risk population (OR, 0.24;95% CI, 0.14-0.40; p=0.60; I2=0%) than in general patient population. Conclusion : The results of meta-analysis indicated that AISC is an effective method for reducing shunt infection. We recommend that AISC should be considered for use in infants and high-risk groups. For adult patients, the choice for AISC could be determined based on the treatment cost.

Three Shunt 저항을 이용한 3상 인버터의 상전류 측정방법 (Phase Current Sensing Method Using Three Shunt Resistor for Three Phase Inverter)

  • 김도윤;이용석;문정송;이택기;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.235-236
    • /
    • 2011
  • 본 논문에서는 세 개의 Shunt 저항을 이용하여 3상 인버터의 상전류를 검출하였다. Shunt 저항을 이용할 경우 전류 검출이 불가능한 제한 영역이 발생한다. 이러한 제한영역을 보상하기 위해 제한영역에 대하여 분석하였으며, 제한 영역은 추가적인 전류 추정방법을 이용하여 보상하였다. 이를 시뮬레이션을 통하여 검증하였다.

  • PDF

Three Shunt Resistor를 이용한 향상된 상전류 피드백 방법 (Improved Phase Current Feedback Method Using Three Shunt Resistor)

  • 신승민;이병국;박래관
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.200-201
    • /
    • 2011
  • 본 논문에서는, 동기 전동기 구동을 위해 세 개의 Shunt Resistor를 이용하여 전류를 피드백 받는 방법에 대하여 분석한다. 특히 세 개의 Shunt Resistor를 이용하여 전류를 피드백 받는 경우 인버터 출력 전압의 크기에 따라 피드백 받은 상전류 정보의 왜곡이 발생하는 문제점에 대하여 분석하고 이를 해결하기 위한 새로운 방법을 제안하며, 실험 결과를 통하여 검증한다.

  • PDF

Pd Shunt저항의 제작 및 동력학특성 조사 (Pd Shunt Resistor for Josephson Junction : Fabrication and Dynamic Simulation)

  • 김규태;남두우;이규원;유광민
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.143-145
    • /
    • 2003
  • External shunt resistor is used in Nb/AlOx/Nb Josephson junction which is basic component of RSFQ circuit. This is to increase damping and to make the so called 'self-reset' optimized for high speed operation. In this study, we fabricated and investigated sheet resistance of Pd and PdAu thin film, and simulated the inductance effect of the shunt resistor to the Josepshon junction dynamics.

  • PDF

뇌실복강단락술 후 발생한 복강 내 가성낭종 (Abdominal Cerebrospinal Pseudocyst: a Complication of Ventriculoperitoneal Shunt in a Child)

  • 부윤정
    • Advances in pediatric surgery
    • /
    • 제16권2호
    • /
    • pp.196-202
    • /
    • 2010
  • Abdominal cerebrospinal fluid pseudocyst is an uncommon complication of ventriculoperitoneal shunt (VPS) performed for hydrocephalus. The incidence of VPS complications in children is higher than in adults. There are controversies and difficulties in the treatment of the abdominal pseudocyst. We report a case of abdominal pseudocyst complicating VPS in a boy. Partial excision of pseudocyst and replacement of the VP shunt were effective during a followup of 18 months postoperatively with no recurrence.

  • PDF

Percutaneous Insertion of the Distal Catheter during Ventriculo-Atrial Shunts. A Simple and Reliable Method

  • Kim, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권6호
    • /
    • pp.429-431
    • /
    • 2007
  • Although the ventriculo-peritoneal shunt is the treatment of choice when hydrocephalus should be corrected, the ventriculo-atrial shunt still holds strong alternative when the peritonium is precluded due to the several reasons. During the ventriculo-atrial shunt operation, it is not always easy to dissect and find the corresponding venous structures. In this technical note, the author describes a simple method of percutaneous insertion for placement of the atrial end.

Endoscopic Third Ventriculostomy in Patients with Shunt Malfunction

  • Lee, Seung-Hoon;Kong, Doo-Sik;Seol, Ho-Joon;Shin, Hyung-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권4호
    • /
    • pp.217-221
    • /
    • 2011
  • Objective : This paper presents data from a retrospective study of endoscopic third ventriculostomy (ETV) in patients with shunt malfunction and proposes a simple and reasonable post-operative protocol that can detect ETV failure. Methods : We enrolled 19 consecutive hydrocephalus patients (11 male and 8 female) who were treated with ETV between April 2001 and July 2010 after failure of previously placed shunts. We evaluated for correlations between the success rate of ETV and the following parameters : age at the time of surgery, etiology of hydrocephalus, number of shunt revisions, interval between the initial diagnosis of hydrocephalus or the last shunt placement and ETV, and the indwelling time of external ventricular drainage. Results : At the time of ETV after shunt failure, 14 of the 19 patients were in the pediatric age group and 5 were adults, with ages ranging from 14 months to 42 years (median age, 12 years). The patients had initially been diagnosed with hydrocephalus between the ages of 1 month 24 days and 32 years (median age, 6 years 3 months). The etiology of hydrocephalus was neoplasm in 7 patients; infection in 5; malformation, such as aqueductal stenosis or megacisterna magna in 3; trauma in 1; and unknown in 3. The overall success rate during the median follow-up duration of 1.4 years (9 days to 8.7 years) after secondary ETV was 68.4%. None of the possible contributing factors for successful ETV, including age (p=0.97) and the etiology of hydrocephalus (p=0.79), were statistically correlated with outcomes in our series. Conclusion: The use of ETV in patients with shunt malfunction resulted in shunt independence in 68.4% of cases. Age, etiology of hydrocephalus, and other contributing factors were not statistically correlated with ETV success. External ventricular drainage management during the immediate post-ETV period is a good means of detecting ETV failure.

Spontaneous Cerebellar Hemorrhage with the Fourth Ventricular Hemorrhage : Risk Factors Associated with Ventriculoperitoneal Shunt

  • Shin, Donguk;Woo, Hyun-Jin;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권4호
    • /
    • pp.320-324
    • /
    • 2012
  • Objective : The purposes of this study are to investigate the factors that may be related to ventriculoperitoneal (VP) shunt in patients with cerebellar hematoma and the effect of severe fourth ventricular hemorrhage, causing obstructive hydrocephalus on subsequent VP shunt performance. Methods : This study included 31 patients with spontaneous cerebellar hematoma and concomitant fourth ventricular hemorrhage, who did not undergo a surgical evacuation of hematoma. We divided this population into two groups; the VP shunt group, and the non-VP shunt group. The demographic data, radiologic findings, and clinical factors were compared in each group. The location of the hematoma (whether occupying the cerebellar hemisphere or the vermis) and the degree of the fourth ventricular obstruction were graded respectively. The intraventricular hemorrhage (IVH) score was used to assess the IVH severity. Results : Ten out of 31 patients underwent VP shunt operations. The midline location of cerebellar hematoma, the grade of fourth ventricle obstruction, and IVH severity were significantly correlated with that of VP shunt operation (p=0.015, p=0.013, p=0.028). The significant variables into a logistic regression multivariate model resulted in statistical significance for the location of cerebellar hemorrhage [p=0.05; odds ratio (OR), 8.18; 95% confidence interval (CI), 1.00 to 67.0], the grade of fourth ventricle obstruction (p=0.044; OR, 19.26; 95% CI, 1.07 to 346.6). Conclusion : The location of the cerebellar hematoma on CT scans and the degree of fourth ventricle obstruction by IVH were useful signs for the selection of VP shunt operation in patients with spontaneous cerebellar hematoma and concomitant acute hydrocephalus.

청색증형 선천성 심질환아의 고식적 수술 이후 EBT에 의한 폐혈관계이 비침습적 추적 검사 (Non-invasive Fdlow-up of Pulmonary artey by EBT Other Palliatrve Shunt Operatin)

  • 김민정;박영환;홍유선;이종균;최규옥;조범구
    • Journal of Chest Surgery
    • /
    • 제33권1호
    • /
    • pp.7-19
    • /
    • 2000
  • Background :To assess the accuracy of Electron-Beam Tomography(EBT) in following evaluation of the pulmonary vascular system after a shunt operation in the cyanotic con-genital heart disease with pulmonary stenosis or pulmonary atresia. Material and Method : Sixteen patients(M:F=11:5) who received Blalock-Taussig(n=8) bidirectional cavo-pulmonary shunt(n=10) and unifocalization (n=2) were ncluded in the study. We evaluated the patency of the shunt the morphology of intrapericardial and hilar pulmonary arteries(PA) peripheral pulmonary vascularity by background lung attenuation and the abundance of arterial & venous collateral. Angiography(n=12) and echocardiography(n=20) were used as the gold standard for the comparison of EBT results. Result: EBT was consistent with angiogram/ echo in 100% of the evaluation for the patency of the shunt and in 12(by angiogram 100%) and 19(by echo 95%) for the detection the hypoplasia stenosis or interruption of central PA In measuring of PA EBT and angiogram corrlated(r=0.91) better than EBT-echo(r=0.88) or echo-angiogram(r=0.72) Abundant systemic arterial collateral were noted in 4 and venous collateral in 3 cases. In evaluating the peripheral pulmonary vascularity the homogenous and normal-ranged lung attenuation(m=6) decreased but homo-genous attenuation(n=1) segment-by-sgment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) segment-by-segment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) and venous congestion(n=2) were observed nd 12 of them were compatible with the blood flow pattern revealed by cardiac catheterization. Conclusion: EBT was accurate in the integrated evaluation of the pulmonary vascular system after the shunt including the patency of the shunt operaion the morphology and dimension of the central and hilar PAs and the loco-regional pulmonary flow in the lung parenchyma. It suggests the useful information about the need of secondary shunt operation the proper timing time for total repair and the need of interventional procedure prior to total repair.

  • PDF

Arteriovenous Fistula Formation Using Microscope Rather than Surgical Telescope

  • Lee, Byeong Ho;Suh, In Suck;Cho, A Jin;Noh, Jung Woo;Jeong, Hii Sun
    • Archives of Reconstructive Microsurgery
    • /
    • 제23권2호
    • /
    • pp.97-100
    • /
    • 2014
  • The number of patients with chronic renal failure who require renal replacement therapy is increasing and dialysis is still the mainly used renal replacement therapy. The first choice of surgical technique currently used is side-to-end anastomosis of the radial artery and the cephalic vein. The authors report on a case of an effective arteriovenous shunt operation performed using microscopy. A 53-year-old male with chronic renal failure was referred to plastic and reconstructive surgery department to undergo an arteriovenous shunt operation. Venography was performed before surgery in order to find the appropriate vessel for the arteriovenous shunt operation. The cephalic vein on the wrist showed a diameter of over 4 mm, which was appropriate for an arteriovenous shunt operation. Anastomosis of the vessels was performed under microscopy using Nylon #9-0. Blood flow and vessel diameter were evaluated by venography after surgery and showed well maintained function of the shunt. Complications such as bleeding, edema of the upper arm, and wound dehiscence did not occur. Many factors and certain complications may affect the long-term patency of an arteriovenous shunt; however, exquisite surgical technique is the most important factor in a successful operation. Thus, arteriovenous shunt operation using microscopy is thought to be a good treatment option.