• Title/Summary/Keyword: Shoulder region

Search Result 168, Processing Time 0.029 seconds

Numerical study on the effect of three-dimensional unsteady tunnel entry flow characteristics on the aerodynamic performance of high-speed train (터널진입시 비정상 유동특성이 고속전철의 공력성능에 미치는 영향에 관한 수치해석적 연구)

  • 정수진;김태훈;성기안
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.5
    • /
    • pp.596-606
    • /
    • 2002
  • The three-dimensional unsteady compressible Euler equation solver with ALE, CFD code, PAM-FLOW based on FEM method has been applied to analyze the flow field around the high speed train which is entering into a channel. From the present study, the pressure and flow transients were calculated and analyzed. The generation of compression wave was observed ahead of train and the high pressure in the gap between the train and the tunnel was also found due to the blockage effects. It was found that abrupt fluctuation in pressure exists in the region from train nose to shoulder of train corresponding to 10% of total length of train during tunnel entry. Computed time history of aerodynamic forces of train during tunnel entry show that drag coefficient rapidly rises and saturates at about non-dimensional time 0.31. The total increase of drag coefficient before and after tunnel entry is about 1.1%. Transient profile of lift force shows similar pattern to drag coefficient except abrupt drop after saturation and lift force in the tunnel increases 0.08% more than that before tunnel entry.

Interactive Virtual Anthroscopy Using Isosurface Raycasting Based on Min-Max Map (최대-최소맵 기반 등위면 광선투사법을 이용한 대화식 가상 관절경)

  • 임석현;신병석
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.103-109
    • /
    • 2004
  • A virtual arthroscopy is a simulation of optical arthroscopy that reconstructs anatomical structures from tomographic images in joint region such as a knee, a shoulder and a wrist. In this paper, we propose a virtual arthroscopy based on isosurface raycasting, which is a kind of volume rendering methods for generating 3D images within a short time. Our method exploits a spatial data structure called min-max map to produce high-quality images in near real-time. Also we devise a physically-based camera control model using potential field. So a virtual camera can fly through in articular cavity without restriction. Using the high-speed rendering method and realistic camera control model, we developed a virtual arthroscopy system.

Experimental Study for Enhancement of Material Strength In Cold Cross Wedge Rolling Process (냉간 전조압연 공정에서의 성형조건에 따른 재료의 물성변화분석)

  • Yoon D. J.;Kim I. H.;Choi S. O.;Lim S. J.;Lee H. W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.319-324
    • /
    • 2004
  • Cross wedge rolling process is utilized to manufacture multi-stepped axis symmetrical parts. This process is generally performed under high temperature conditions in order to induce serious deformation. But cold cross wedge rolling process has been rarely studied due to the limits of deformation. Recently, the cold cross wedge rolling process has been utilized to enhance the material strength in specified parts of manufactured products. In this paper, experimental researches were carried out with various forming conditions of cold cross wedge rolling process in order to suggest the design guidance to make preform for cold cross wedge rolling. The tensile strength and the surface hardness of specified region were compared to that of initial material with the variation of the area reduction and the rotational speed of rolling die. With respect to the area reduction, the maximum tensile strength was linearly increased and the surface hardness was rapidly increased within lower percent of area reduction. The surface hardness was saturated over the rotational die speed of 0.8 RPM.

  • PDF

Subjective symptoms in musculoskeletal and preventive actions of Dental technicians in Daegu Metropolitan City (대구지역 치과기공사의 근골격계 자각증상과 예방행위)

  • Jang, Eun-Jin;Bark, Young-Dae
    • Journal of Technologic Dentistry
    • /
    • v.36 no.4
    • /
    • pp.257-266
    • /
    • 2014
  • Purpose: This report intend to provide basic materials of Musculoskeletal diseases prevention program development and preventive measures establishing by surveying Musculoskeletal symptoms. Musculoskeletal disease and Musculoskeletal disease prevention act about dental technician in Daegu. Methods: From October. 2012 to November. 2012 by conducting self - survey using questionnaire and use unit490 final analysis data. Results: In dental Technicians, as the musculoskeletal symptoms back or waist pain rate appear such as 28.2% and as the musculoskeletal disorders, the shoulder region pain complaint rate appear highly such as 87.4%. Musculoskeletal disease prevention act was highly appeared man more than women, the married than the unmarried, over 10 years dental experience, fewer working hours per day, the average monthly income is greater regular medical check-up dental technician than technician who do not. As working environment, In case working in laboratory whch dust is well ventilated and with a barrier, Musculoskeletal disease prevention act rate was highly appeared more than another technician who do not. Conclusion: We must prepare an effective preventive measures. To development Musculoskeletal disease prevention program suitable for dental technic working and make obliged to practice.

Influence of the adjacent periodontium and inter-implant distance on bone resorption around non-submerged implants;A retrospective clinical and radiographic study (인접 치주조직과 임플란트간 거리가 임플란트 주변 골흡수에 미치는 영향;임상 및 방사선사진 검사에 의한 후향적 연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.535-541
    • /
    • 2004
  • The aims of the present study are firstly to investigate the amount of bone loss around non-submerged implants placed in the posterior region and secondly to investigate the relationship between inter-implant and implant-tooth distance and peri-implant bone loss. Thirty-one subjects with 60 implants were selected consecutively from the implant patient pool at the department of Chonbuk National University Hospital. To be included in the study subject, the implant should have been functioned more than 6 months after loading. Inter-implant and implant-tooth distance, distance between implant shoulder and the first bone contact with the implant(DIB) were measured from the scanning image of the radiograph of each implant. The result showed that; 1. inter-implant distance has a statistically significant relationship with DIB in Pearson correlation analysis. 2. the DIB at the implant facing surface of the implant was greater than that of tooth facing surface of the implant. Within limitation of this study, it is suggested to place an implant not too closely to adjacent implants, and the presence of a tooth adjacent to an implant may keep the level of tooth-facing surface of the implant. Further studies with a prospective design are needed to elucidate the relationship between bone changes and various dimensions around implants.

A Study on Somatotype of Elderly Women (노년기 여성 체형의 자세 및 실루엣)

  • 김경화
    • Journal of the Korean Home Economics Association
    • /
    • v.34 no.2
    • /
    • pp.183-199
    • /
    • 1996
  • The objective of this study was to provide fundamental data on somatotype for elderly women by classifying the somatotype and analysing the 3 characteristics of their somatotype. The subject were 368 women of 60~84 years old, they were analyzed indirect photography. To find out differences among the age groups, the 368 subjects were grouped into two age groups (Group 1 ; age 60 to 69, Group 2 ; aged 70 to 84). Data were analyzed using Factor analysis, Cluster analysis, duncan test and Analysis of variance. Through the factor analysis, 27 items from photometric measurements respectively. Cluster analysis was applied for classification of somatotype. The results of this study were as follows. 1. The characteristics of Elderly women's somatotype were bending of the upper-torso, fatness of the waist and abdomen, drooping of the bust and shoulder and hip. In addition, height, girth, depth and width items were decreased in their sizes respectively. 2. The characteristics of clusters were as follows. Type 1 was straight somatotype in which the plumb line through tragion, the bust depth and under bust depth region laterally. Type 2 was swayback somatotype in which the upper portion of protruding point on the back was bent forward but the lower portion of protruding point had a characteristics of turning over somatotype. Type 3 was bending somatotype. Namely, this type was shorter than average and below the average fatness. Generally, the lateral view silhouette of elderly women was the straight type and changed into bending type as the age increases.

  • PDF

Tear Extraction from Ultrasonic Images of Shoulder Tendon using Image Processing (영상 처리 기법을 이용한 어깨 힘줄 초음파 영상에서의 인대 손상 영역 추출)

  • Kim, Min-Ha;Lee, Ji-Hyeon;Son, Byeong-Seok;Kim, Yoon-Ho;Kim, Kwang Beak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.477-479
    • /
    • 2016
  • 본 논문에서는 초음파 영상에서 어깨 부위를 분석하여 어깨 힘줄(Tendon) 영역에서 인대 손상영역을 추출하는 방법을 제안한다. 제안된 방법은 초음파 영상에서 ROI(Region of Interest)을 추출하고 샤프닝 기법을 적용하여 ROI 영역을 뚜렷한 후에 퍼지 스트레칭 기법을 적용하여 명암 대비를 높인 후, 평균 이진화 기법을 적용하여 ROI 영역을 이진화 한다. 이진화된 ROI 영역에 침식, 팽창기법과 라벨링 기법을 적용하여 전체 ROI의 면적 영역에서 0.4%이하인 객체 영역들을 잡음으로 간주하여 제거한 후, ROI 영역에서 수평 너비가 가장 큰 영역의 상단 경계에 스플라인 곡선을 적용한다. 스플라인 곡선이 적용된 영역에서 곡선이 가장 높은 지점을 구한 후, 구한 지점으로부터 ROI 영역의 세로 길이의 1/5를 갖는 상단부분을 제거한 후에 양자화할 영역을 추출하고 FCM을 적용하여 양자화를 한다. 양자화된 영역에서 어깨 힘줄 영역 안에 있는 인대 손상의 후보 영역을 추출하고 면적의 크기가 0.14%이상이거나 3%이하인 영역을 어깨 힘줄의 인대 손상 영역으로 추출한다. 제안된 방법을 어깨 힘줄이 있는 초음파 영상을 대상으로 실험한 결과, 제안된 방법이 어깨 힘줄의 인대 손상 영역이 비교적 정확히 추출되었다.

  • PDF

Multi-view Human Recognition based on Face and Gait Features Detection

  • Nguyen, Anh Viet;Yu, He Xiao;Shin, Jae-Ho;Park, Sang-Yun;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.12
    • /
    • pp.1676-1687
    • /
    • 2008
  • In this paper, we proposed a new multi-view human recognition method based on face and gait features detection algorithm. For getting the position of moving object, we used the different of two consecutive frames. And then, base on the extracted object, the first important characteristic, walking direction, will be determined by using the contour of head and shoulder region. If this individual appears in camera with frontal direction, we will use the face features for recognition. The face detection technique is based on the combination of skin color and Haar-like feature whereas eigen-images and PCA are used in the recognition stage. In the other case, if the walking direction is frontal view, gait features will be used. To evaluate the effect of this proposed and compare with another method, we also present some simulation results which are performed in indoor and outdoor environment. Experimental result shows that the proposed algorithm has better recognition efficiency than the conventional sing]e view recognition method.

  • PDF

Structure Analyses of Rubber/Filler System under Shear Flow by Using Time Resolved USAXS Method

  • Nishitsuji, Shotaro;Takenaka, Mikihito;Amino, Naoya;Ishikawa, Yasuhiro
    • Elastomers and Composites
    • /
    • v.54 no.2
    • /
    • pp.156-160
    • /
    • 2019
  • The changes in the dispersion of carbon black in liquid polyisoprene under shear flow with time have been investigated by time-resolved ultra small-angle X-ray scattering (USAXS) method. The analyses of USAXS profile immediately after the start of shear flow clarified that the aggregates of carbon black with a mean radius of gyration of 14 nm and surface fractal dimension of 2.5 form the fractal network structure with mass-fractal dimension of 2.9. After the application of the shear flow, the scattering intensity increases with time at the observed whole entire q region, and then the a shoulder appears at $q=0.005nm^{-1}$, indicating that the agglomerate is broken and becomes smaller by shear flow. The analysis by the Unified Guinier/Power-law approach yielded several characteristic parameters, such as the sizes of aggregate and agglomerate, mass-fractal dimension of agglomerate, and surface fractal dimension of the primary particle. While the mean radius of gyration of the agglomerate decreases with time, the mean radius of gyration of the aggregate, mass fractal dimension, and surface fractal dimension don't change with time, indicating that the aggregates peel off the surface of the agglomerate.

Clavicle Fracture Site Surgical Contouring: A Case Report

  • Annachiara Cavaliere;Vincenzo Cepparulo;Giuseppe Pezone;Fabrizio Schonauer
    • Archives of Plastic Surgery
    • /
    • v.51 no.1
    • /
    • pp.67-71
    • /
    • 2024
  • Clavicle fractures are frequent injuries accounting for approximately 4% of all fractures in adults with about 35% occurring in the shoulder region among which midshaft fractures are the most common (>66%). Nonsurgical management is the treatment of choice for most clavicle fractures; however, poor functional and aesthetic outcomes may result from nonunion, symptomatic malunion, and aesthetic impairment which are the most common complications. A young woman was referred to our clinic for a "Step Deformity" resulting after primary, nonsurgical treatment of a midshaft clavicle fracture. Residual deformity was corrected with a novel simple and little invasive approach. Midshaft clavicle fractures typically only require conservative nonsurgical treatment, nevertheless suboptimal outcomes may occur. Selective osteotomies and fixation are deemed too invasive when only cosmetic impairment of the clavicle contour is present without any functional or sensitive damage and most patients are discouraged from undergoing surgery. Thus far, no specific focus on this topic, nor exploration of possible correction can be found in the published literature. These residual deformities may be very noticeable sometimes and cause psychological distress and social life impairment. Despite no related functional impairment, this deformity should still be addressed, to improve patients' quality of life.