• Title/Summary/Keyword: Short-rod specimen

Search Result 6, Processing Time 0.018 seconds

New record of a sea star of genus Henricia (Asteroidea: Spinulosida: Echinasteridae) from Jeju Island, Korea

  • Ubagan, Michael Dadole;Shin, Sook
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.1
    • /
    • pp.68-71
    • /
    • 2019
  • An asteroid specimen that belongs to the genus Henricia was collected from the waters near Ongpo harbor, Jeju Island using fishing net on 24 January 2017. The specimen was identified as Henricia anomala Hayashi, 1973, which belongs to the family Echinasteridae and order Spinulosida. Henricia anomala was first described by Hayashi, 1973, who captured it from Sagami Bay at a depth of 110-116 m. This species can be distinguished from other Henricia species by short arms (R/r=4), abactinal spines lining the abactinal plates and bearing about two to five spinelets, closely meshed abactinal skeleton, composed of small rod-like and subtriangular plates, a narrow papular area containing one or two papulae, and adambulacral armature composed of five to seven bluntly pointed spinelets. This is the first report of Henricia anomala in Korea.

A study on the estimation of fracture toughness of granite by acoustic emission (미소 파괴음 빈도 측정에 의한 화강암의 파괴인성 평가에 관한 연구)

  • 신재근;이상은;임한욱
    • Tunnel and Underground Space
    • /
    • v.10 no.2
    • /
    • pp.227-236
    • /
    • 2000
  • The fracture toughness can be measured by the two testing methods using chevron-notched specimen according to the ISRM Working Group of Commission of Testing Methods. They are chevron bend (CB) test and short rod (SR) test. In this study, the suggested methods (Level I tests) were conducted on the CB and SR specimens of Chuncheon granite. In addition. the J-integral analysis was combined with an acoustic emission technique to determine the fracture toughness. The results from two telling methods were analyzed in terms of the anisotropy and the acoustic emission characteristics.

  • PDF

The study of fractural behavior of repaired composite (수리된 복합 레진 수복물의 파괴 거동에 관한 연구)

  • Park, Sang-Soon;Nam, Wook;Eom, Ah-Hyang;Kim, Duck-Su;Choi, Gi-Woon;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.461-472
    • /
    • 2010
  • Objectives: This study evaluated microtensile bond strength (${\mu}TBS$) and short-rod fracture toughness to explain fractural behavior of repaired composite restorations according to different surface treatments. Materials and Methods: Thirty composite blocks for ${\mu}TBS$ test and sixty short-rod specimens for fracture toughness test were fabricated and were allocated to 3 groups according to the combination of surface treatment (none-treated, sand blasting, bur roughening). Each group was repaired immediately and 2 weeks later. Twenty-four hours later from repair, ${\mu}TBS$ and fracture toughness test were conducted. Mean values analyzed with two-way ANOVA / Tukey's B test ($\alpha$= 0.05) and correlation analysis was done between ${\mu}TBS$ and fracture toughness. FE-SEM was employed on fractured surface to examine the crack propagation. Results: The fresh composite resin showed higher ${\mu}TBS$ than the aged composite resin (p < 0.001). Mechanically treated groups showed higher bond strength than non-mechanically treated groups except none-treated fresh group in ${\mu}TBS$ (p < 0.05). The fracture toughness value of mechanically treated surface was higher than that of non-mechanically treated surface (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. Specimens having high KIC showed toughening mechanism including crack deviation, microcracks and crack bridging in FE-SEM. Conclusions: Surface treatment by mechanical interlock is more important for effective composite repair, and the fracture toughness test could be used as an appropriate tool to examine the fractural behavior of the repaired composite with microtensile bond strength.

Development of Precision Drilling Machine for the Instrumentation of Nuclear Fuels (핵연료계장을 위한 정밀 드릴링장치 개발)

  • Hong, Jintae;Jeong, Hwang-Young;Ahn, Sung-Ho;Joung, Chang-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.2
    • /
    • pp.223-230
    • /
    • 2013
  • When a new nuclear fuel is developed, an irradiation test needs to be carried out in the research reactor to analyze the performance of the new nuclear fuel. In order to check the performance of a nuclear fuel during the irradiation test in the test loop of a research reactor, sensors need to be attached in and out of the fuel rod and connect them with instrumentation cables to the measuring device located outside of the reactor pool. In particular, to check the temporary temperature change at the center of a nuclear fuel during the irradiation test, a thermocouple should be instrumented at the center of the fuel rod. Therefore, a hole needs to be made at the center of fuel pellet to put in the thermocouple. However, because the hardness and the density of a sintered $UO_2$ pellet are very high, it is difficult to make a small fine hole on a sintered $UO_2$ pellet using a simple drilling machine even though we use a diamond drill bit made by electro deposition. In this study, an automated drilling machine using a CVD diamond drill has been developed to make a fine hole in a fuel pellet without changing tools or breakage of workpiece. A sintered alumina ($Al_2O_3$) block which has a higher hardness than a sintered $UO_2$ pellet is used as a test specimen. Then, it is verified that a precise hole can be drilled off without breakage of the drill bit in a short time.

A STUDY ON FRACTURAL BEHAVIOR OF DENTIN-RESIN INTERFACE (상아질-복합레진 접착계면의 파괴거동에 대한 연구)

  • Ryu, Gil-Joo;Choi, Gi-Woon;Park, Sang-Jin;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.208-221
    • /
    • 2007
  • The fracture toughness test is believed as a clinically relevant method for assessing the fracture resistance of the dentinal restoratives. The objectives of this study were to measure the fracture toughness $(K_{1C})$ and microtensile bond strength of dentin-resin composite interface and compare their relationship for their use in evaluation of the integrity of the dentin-resin bond. A minimum of six short-rod specimens for fracture toughness test and fifteen specimens for microtensile bond strength test was fabricated for each group of materials used. After all specimens storing for 24 hours in distilled water at $37^{\circ}C$, they were tensile-loaded with an EZ tester universal testing machin. Statistical analysis was performed using ANOVA and Tukey's test at the 95% confidence level, Pearson's coefficient was used to verify the correlation between the mean of fracture toughness and microtensile bond strength. FE-SEM was employed on fractured surface to describe the crack propagation. Fracture toughness value of Clearfil SE Bond (SE) was the highest, followed by Adper Single Bond 2 (SB), OptiBond Solo (OB), ONE-STEP PLUS (0S), ScotchBond Multi-purpose (SM) and there was significant difference between SE and other 4 groups (p < 0.05). There were, however, no significant difference among SB, OB, OS, SM (p > 0.05). Microtensile bond strength of SE was the highest, followed by SB, OB, SM, OS and OS only showed significant lower value (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. FE-SEM examination revealed that dentin bonding agent showed different film thickness and different failure pattern according to the film thickness. From the limited results of this study, it was noted that there was statistically no correlation between K1C and ${\mu}TBS$. We can conclude that for obtaining the reliability of bond strength test of dentin bonding agent, we must pay more attention to the test procedure and its profound scrutiny.

Characterization of Microstructures and Fracture Toughness of SR Specimen in Granitic Rocks (화강암에서 SR 시편의 파괴인성과 미세구조적인 특징)

  • Lee, Sang-Eun
    • Tunnel and Underground Space
    • /
    • v.20 no.3
    • /
    • pp.217-224
    • /
    • 2010
  • Three relatively homogeneous granitic rocks were studied to investigate the relationship between their microstructural properties and fracture toughness. Fracture toughness and ultrasonic velocity were varied with the orientation of mineral's long axis and microcrack, obtained from optical microscope. The lowest fracture toughness values are obtained, when the fracture propagates parallel to weakness planes which have the orientation of mineral's long axis and microcrack, in other words, when weakness planes develop perpendicular to the direction of tensile stress agrees with that of rift plane. The fracture toughness values, measured with the short rod method, varied from 1.63 to 2.62 MPa $m^{0.5}$, and their values are related with the average grain size and average microcrack length.