• Title/Summary/Keyword: Short-circuit line

Search Result 201, Processing Time 0.048 seconds

Simplified Synthetic Testing Facility with Modified TRV Circuit

  • Chong, Jin-Kyo;Lee, Kyung Seob;Lee, Chang-Hoon;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.881-885
    • /
    • 2018
  • In order to develop a gas circuit breaker (GCB), the breaking performance of the short line fault (SLF) should be prioritized over that of the breaker terminal fault (BTF). In brief, it is necessary to evaluate the thermal characteristics of the insulating gas that is filled in a GCB. In the process of developing a GCB, many companies use the simplified synthetic testing facility (SSTF).In order to evaluate the SLF breaking performance of a GCB with a long minimum arcing time, a modifications to the conventional SSTF was proposed. In this study, we developed the SSTF with a modified transient recovery voltage circuit. The performance of the newly developed SSTF was verified by an $L_{90}$ breaking performance test on a rating combination of 170 kV, 50 kA, and 60 Hz.

Measurement Method for Catenary Line Constant (전차선로의 회로정수 측정방안 연구)

  • 오광해;이한민;이장무;이기원
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.620-627
    • /
    • 2000
  • This paper presents a mettled to obtain line constants for a catenary system. To find them, voltages, currents and power factors according to frequencies were measured in short circuit and open circuit respectively. And front the measured data, resistances, inductances and capacitances were also calculated.

  • PDF

Development of a 170kV 50kA Capacitorless Gas Circuit Breaker

  • Park, K. Y.;K. D. Song;Y. H. Oh;W. P. Song;J. H. Kang;Park, S. W.
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.3
    • /
    • pp.73-76
    • /
    • 2003
  • In modern EHV (Extra High Voltage) class GCBs (Gas Circuit Breakers), the interruption capability for SLF (Short Line Fault) is one of the most important aspects of performance required for GCBs. Up to now, the SLF interruption capability of EHV class GCBs was partially assisted by the adoption of capacitors able to decrease the dV/dt of the TRV (Transient Recovery Voltage), particularly the TRV on the line side. This paper describes the technique to increase the SLF interruption capability of EHV class GCBs as well as the procedure to develop capacitorless l70kV 50kA GCB.

Study on Application of Superconducting Fault Current Limiter Considering Risk of Circuit Breaker Short-Circuit Capacity in a Loop Network System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1789-1794
    • /
    • 2014
  • This paper suggests an application method for a superconducting fault current limiter (SFCL) using an evaluation index to estimate the risk regarding the short-circuit capacity of the circuit breaker (CB). Recently, power distribution systems have become more complex to ensure that supply continuously keeps pace with the growth of demand. However, the mesh or loop network power systems suffer from a problem in which the fault current exceeds the short-circuit capacity of the CBs when a fault occurs. Most case studies on the application of the SFCL have focused on its development and performance in limiting fault current. In this study, an analysis of the application method of an SFCL considering the risk of the CB's short-circuit capacitor was carried out in situations when a fault occurs in a loop network power system, where each line connected with the fault point carries a different current that is above or below the short-circuit capacitor of the CB. A loop network power system using PSCAD/EMTDC was modeled to investigate the risk ratio of the CB and the effect of the SFCL on the reduction of fault current through various case studies. Through the risk evaluations of the simulation results, the estimation of the risk ratio is adequate to apply the SFCL and demonstrate the fault current limiting effect.

The Study on Countermeasures of Electromagnetic Force by Three Phase Short-Circuit Test of Underground Transmission Cable (송전케이블 삼상단락 실증시험을 통한 전자력 대책방안 연구)

  • Kang, Ji-Won;Park, Hung-Sok;Yoon, Jong-Keon;Kim, Yang-Sang;Hong, Dong-Suk;Chang, Woo-Seog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2342-2348
    • /
    • 2009
  • Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, the interaction of electromagnetic force by fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, and close consideration is required for it. This paper presents countermeasures to reduce and release the effect of electromagnetic force with rope binding and installation of spacer and describes its efficacy through three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

A Study on Future System Construction Using WSCR Strengthness Index based on Python (Python 기반 WSCR 강건 지수를 이용한 미래계통 구축에 관한 연구)

  • Park, Seong-Jun;Hur, Jin;Kim, Hyun-Jin;Cho, Yoon-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.994-1001
    • /
    • 2018
  • In this paper, to studied about future power system construction using PSS / E-Python API. Python-based future system automatical construction methods and modeling of renewable sources. it confirmed the stability of the powert system for each renewable area by calculating the weighted short circuit ratio (WSCR) index. it calculated the short circuit ratio (SCR) and selected the transmission line linkage scenario to improve the stability of vulnerable areas. it confirmed the WSCR index improvement through the selected transmission line linkage of scenario, and analyzed the stability of the renewable power system applying the scenario. It describes Facts and Shunt devices adjustment for the load flow convergence. It describes the stable methed of the bus voltage through the transformer Ratio Tap adjustment. By performing PSS/E ASCC using the Python it was performed three-phase short circuit fault capacity analysis, it is confirmed whether excess of the fault current circuit breaker capacity. In order to contingency accident analysis, it have described the generation of one or two line list of each areas using the Python. The list is used to contingency analysis and describe the soluted of the transmission line overload through comparison before and after adding the scenario line.

A Short Wavelength Transmission Line Employing Periodically Arrayed Capacitive Devices on MMIC (MMIC상에서 주기적으로 배치된 용량성 소자를 이용한 단파장 전송선로)

  • Jeong, Jang-Hyeon;Kang, Suk-Youb;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.840-845
    • /
    • 2010
  • In this paper, short-wavelength transmission line employing periodically arrayed capacitive devices (PACD) structures were developed for application to a development of miniaturized on-chip passive components on GaAs monolithic microwave integrated circuit (MMIC). The transmission line employing PACD structure showed a wavelength much shorter than conventional microstrip line. Concretely, the wavelength of the transmission line employing PACD structure was 8 % of the conventional microstrip line on GaAs substrate at 5GHz. And It was 38% of the microstrip line employing PPGM at 5GHz. It was recognized that the basic characteristics of the transmission line employing PACD structure were investigated for application to the miniaturized passive on-chip components.

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.

A Study on Development of Over-load Fault Prevention Apparatus using Distribution Line Voltage (배전선로 선로전압을 이용한 과부하 사고 예방장치 개발에 관한 연구)

  • Kwak, D.K.;Park, D.H.;Park, Y.J.;Jung, D.Y.;Kim, D.K.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.617-618
    • /
    • 2012
  • Recently as the inactive response characteristics of the existing RCD(Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is proposed a prevention apparatus using neutral line voltage and semiconductor switching devices for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The proposed prevention apparatus confirms the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker(RCD) through various operation performance analysis.

  • PDF

A Coupled Line Impedance Transformer for High Termination Impedance with a Bandpass Filtering Response

  • Kim, Phirun;Jeong, Yongchae
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.41-45
    • /
    • 2018
  • In this study, a short-ended coupled line with a short-circuit stub transmission line bandpass filtering impedance transformer is presented. The general designed equations are derived on the basis of circuit theory. The design curves are provided to examine the characteristic of the proposed impedance transformer. The proposed circuit is suitable for high termination impedance. To validate the design formulas, a $400-50{\Omega}$ impedance transformer is designed and fabricated at the operating center frequency ($f_0$) of 2.6 GHz. The measured results show a good agreement with the simulation. The measured insertion and return losses are 0.6 dB and 22.5 dB at $f_0$, respectively. The measured return loss is higher than 20 dB within the passband frequency of 2.51-2.7 GHz. Moreover, the stopband attenuation is higher than 25 dB from DC to 1.64 GHz of the lower stopband and from 3.12 GHz to 6.4 GHz of the higher stopband.