• Title/Summary/Keyword: Short turn

Search Result 253, Processing Time 0.024 seconds

A Study on Stator Winding Turn-Fault Model for Fault Diagnosis in Inverter-Driven Permanent Magnet Moor Drives (고장진단을 위한 영구자식 동기전동기의 권선 단락에 의한 고장모델 연구 및 특성해석)

  • Kim, Kyeong-Hwa;Choi, Dong-Uk;Gu, Bon-Gwan;Jung, In-Soung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.18-28
    • /
    • 2009
  • To analyze influences under faults caused by a stator winding short and to evaluate an effectiveness of a diagnostic algorithm a faulty model for an inverter-driven permanent magnet synchronous motor is presented. Even though the conventional dq motor model obtained through the transformation of phase voltage model is widely used to analyze and control the motor, it can not be used in the analysis of a faulty motor since the 3-phase balanced condition is no longer hold under the fault caused by a stator winding short, and thus, it is very difficult to obtain motor input voltages from the pole voltage of an inverter. To overcome this problem, a faulty model for an inverter-driven permanent magnet synchronous motor is proposed by considering the line voltage of 3-phase variables. The effectiveness of the proposed faulty model is verified through comparative simulations and experiments using DSP TMS320F28335 and motor built to allow a partial short of inter-turn.

Current Limiting and Voltage Sag Suppressing Characteristics of Flux-lock Type SFCL According to Variations of Turn Number's Ratio (자속구속형 초전도전류제한기의 권선비 변화에 따른 전류제한 및 전압강하 보상 특성)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.410-415
    • /
    • 2011
  • In this paper, we investigated the fault current limiting and the load voltage sag suppressing characteristics of the flux-lock type SFCL, designed with the additive polarity winding, according to the variations of turn number's ratio and the comparative analysis between the resistive type and the flux-lock type SFCLs were performed as well. From the analysis for the short-circuit tests, the flux-lock type SFCL designed with the larger turn number's ratio was shown to perform more effective fault current limiting and load voltage sag suppressing operations compared to the flux-lock type SFCL designed with the lower turn number's ratio through the fast quench occurrence of the high-$T_C$ superconducting (HTSC) element comprising the flux-lock type SFCL. In addition, the recovery time of the flux-lock type SFCL after the fault removed could be confirmed to be shorter in case of the flux-lock type SFCL designed with the lower turn number ratio.

Characteristic Analysis of Shorted-turn for Generator Rotor (발전기 회전자의 층간단락에 대한 특성 해석)

  • Kim S.J.;Jeon Y.S.;Lee S.H.;Choe G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.137-140
    • /
    • 2003
  • Shorted-turns can have significant effects on a generator and its performance. Shorted-turn sensor for synchronous generator's field winding have been developed. One of effective method detecting inter-turn short circuits on round rotor winding is a method using sensor detecting. But the method needs duplicate design of sensor for characteristic change according to types and forms of generator Thus sensing skill without sensor depend on change of electric property in generator. For the reason, this paper presents shorted-turns phenomenon and the characteristic analysis of shorted-turns In synchronous generator by using 2-D finite element method(FEM).

  • PDF

The Structure, Growth and Equilibrium of the Money Market in Korea

  • Oh, Kwan-Chi
    • Journal of the Korean Statistical Society
    • /
    • v.4 no.2
    • /
    • pp.113-125
    • /
    • 1975
  • The money market has been existing in various forms for a long time. Until 1972, however, the market had supplied mainly short-term loans of commercial banks and loans of informal money lenders to business corporations. There was no market for notes and commercial papers of business corporations. Consequently, business corporations had to rely primarily upon commercial banks for short-term credit loans to supplement their working capital. The interest rate on loans of commercial banks had been set below a free market equilibrium rate and thereby, generated excess demands for the loans. Unsatisfied potential borrowers thus had to turn to informal money lenders for short-term cerdit loans of prohibitively high interest rate. Since 1972 investment and finance companies have been operating in the money market and their role in mobilizing short-term loans is increasing. This paper aims at estimating the equilibrium size of the money market.

  • PDF

Fault Detection and Diagnosis of Winding Short in BLDC Motors Based on Fuzzy Similarity

  • Bae, Hyeon;Kim, Sung-Shin;Vachtsevanos, George
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.9 no.2
    • /
    • pp.99-104
    • /
    • 2009
  • The turn-to-turn short is one major fault of the motor faults of BLDC motors and can appear frequently. When the fault happens, the motor can be operated without breakdown, but it is necessary to maintain the motor for continuous working. In past research, several methods have been applied to detect winding faults. The representative approaches have been focusing on current signals, which can give important information to extract features and to detect faults. In this study, current sensors were installed to measure signals for fault detection of BLDC motors. In this study, the Park's vector method was used to extract the features and to isolate the faults from the current measured by sensors. Because this method can consider the three-phase current values, it is useful to detect features from one-phase and three-phase faults. After extracting two-dimensional features, the final feature was generated by using the two-dimensional values using the distance equation. The values were used in fuzzy similarity to isolate the faults. Fuzzy similarity is an available tool to diagnose the fault without model generation and the fault was converted to the percentage value that can be considered as possibility of the fault.

Probeless Estimation of Electroluminescence Intensities Based on Photoluminescence Measurements of GaN-Based Light-Emitting Diodes

  • Kim, Jongseok;Jeong, Hoon;Choi, Won-Jin;Jung, Hyundon
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • The electroluminescence (EL) intensities of GaN-based light-emitting diodes (LEDs) are estimated based on their photoluminescence (PL) properties. The PL intensity obtained under open-circuit conditions is divided into two parts: the PL intensity under a forward bias lower than the optical turn-on voltage, and the difference between the PL intensities under open-circuit conditions and under forward bias. The luminescence induced by photoexcitation under a constant forward bias lower than the optical turn-on voltage is primarily the PL from the excited area of the LED. In contrast the intensity difference, obtained by subtracting the PL intensity under the forward bias from that under open-circuit conditions, contains the EL induced by the photocarriers generated during photoexcitation. In addition, a reverse photocurrent is generated during photoexcitation under constant forward bias across the LED, and can be correlated with the PL-intensity difference. The relationship between the photocurrent and PL-intensity difference matches well the relationship between the injection current and EL intensity of LEDs. The ratio between the photocurrent generated under a bias and the short-circuit current is related to the ratio between the PL-intensity difference and the PL intensity under open-circuit conditions. A relational expression consisting of the ratios, short-circuit current, and PL under open-circuit conditions is proposed to estimate the EL intensity.

Efficient One-dimensional Current Configuration and Encoding Method for ITSC Diagnosis of 3-Phase Induction Motor using CNN (CNN을 이용한 3상 유도전동기 ITSC 진단의 효율적인 1차원 전류 신호 구성 및 Encoding방법)

  • Yeong-Jin Goh
    • Journal of IKEEE
    • /
    • v.28 no.2
    • /
    • pp.180-186
    • /
    • 2024
  • This paper proposes an efficient fault diagnosis method for ITSC(Inter-Turn Short Circuit) in three-phase induction motors using CNN. By utilizing only the D-axis component of the D-Q synchronous coordinate system, it compares SWM(Slide Window Method) and GAF(Gramian Angular Field) methods for image encoding. Results show GAF achieving ~74% accuracy, while SWM achieves ~65%, indicating GAF's superiority by 9%. Learning time (~14.74s) remains consistent, particularly with epochs ≤ 100, showcasing faster learning.

Diagnosis Method and Characteristic Analysis of Shorted Turns on Generator Rotor using Flux Sensorless (자속센서리스 회전자 층간단락 진단기법 및 특성해석)

  • Kim Sun-Ja;Jeon Ywun-Seok;Lee Seung-Hak;Jeong Byung-Hwan;Lee Myung-Un;Choe Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.257-263
    • /
    • 2005
  • Short-circuit rotor windings on a generator causes unstable oscillation of unbalance of flux, asymmetrical heat. In order to prevent serious accidents of short-circuit rotor windings, it is important to study the shorted-turn diagnosis method for rotor windings of the generator. To improve the defects of the diagnosis with sensors, the new sensorless method for rotor shorted-turn diagnosis is proposed, which is to measure the electrical values of the voltage and current at the generator and then to detect if the shorted-turned phenomena would occurred. For the feasibility of the suggested method the theoretical results are shown in the aspects of the air-gap flux density, the flux leakage, the generated output voltage and the shorted field current through the digital simulation. Also the possibility of decision for the suggested sensorless method could be shown in this paper.

A Study on Application of TPCLT(Twice Per Cycle Left-Turn) for a Signalized Three-Leg Intersection (3지 교차로의 TPCLT(Twice Per Cycle Left-Turn) 적용 방안 연구)

  • Han, Dajeong;Kim, Eungcheol
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.2
    • /
    • pp.77-92
    • /
    • 2019
  • TPCLT is a advanced signal system that serves twice left turn phases during the same cycle. TPCLT can be a useful where the left turn traffic volume is high and the length of the left turn lane is short. This study examined the effectiveness of TPCLT in reducing delay for a signalized three-Leg intersection and proposed the application of TPCLT signal system. 108 scenarios with different traffic volumes were created. This study analyzed the control delay of the three-Leg intersection in case TPCLT is operated and non-TPCLT is operated. As a result of analysis, it was shown that TPCLT was effective in most of the scenarios. When traffic volume ratio of the left turn is 30~40%, TPCLT was more effective at reducing the control delay. The study result shows significant delay reduction for the left turning traffic and it is approximately 50 seconds. The opposing movement's average control delay increased 2 seconds. The effect of TPCLT on the length of left turn lane was analyzed. As a result, it is found that TPCLT is effective when the length of left turn lane is 30%~60% compared to that of conventional three leg intersection operations.