• Title/Summary/Keyword: Short turn

Search Result 253, Processing Time 0.029 seconds

Comparison of Skiing Time and Vertical Ground Reaction Force between the Short Turn and Basic Parallel Turn during Alpine Skiing

  • Kim, Jin-Hae;Kim, Joo-Nyeon
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.4
    • /
    • pp.257-262
    • /
    • 2017
  • Objective: This study aimed to investigate the differences in skiing time and vertical ground reaction force (vGRF) between the basic parallel turn and short turn. Method: Eleven alpine ski instructors (age: $28.73{\pm}4.29yrs$, height: $172.36{\pm}6.30cm$, body mass: $71.45{\pm}9.16kg$, career: $11.09{\pm}2.70yrs$) participated in this study. Each skier was asked to perform a basic parallel turn and short turn on a $16^{\circ}$ groomed slope. A foot pressure measurement system was used to measure the skiing time and vGRF under the three plantar regions (forefoot, midfoot, rearfoot). Results: Skiing time decreased significantly in all three phases during the short turn (p<.05). In the initiation phase, the vGRF showed a greater decrease on the midfoot and rearfoot during the short turn (p<.05). In the steering phase 1, the vGRF showed a greater increase on the forefoot and decreased on the midfoot during the short turn (p<.05). In the steering phase 2, the vGRF showed a greater increase on the forefoot and rearfoot during the short turn (p<.05). Conclusion: Our findings proved that the skiing time and vGRF changed during the short turn. Consequently, we suggest that recreational skiers should decrease the skiing time of the steering phase compared to that of the initiation phase and increase the vGRF on the forefoot and rearfoot in the steering phase.

A Prioritization Method Considering Trip Patterns to Introduce Short-turn Buses (단거리 순환버스 도입을 위한 통행패턴 기반의 우선순위 결정방법)

  • Moon, Sedong;Kim, Dong-Kyu;Cho, Shin-Hyung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.5
    • /
    • pp.1-18
    • /
    • 2019
  • A short-turn bus is a bus that is operated within a subsection of an existing bus line. Previous studies regarding short-turn buses decided optimal turn-back points for a single bus line rather than a bus network. Also, in-vehicle crowding which has a significant impact on transit convenience was rarely considered. Therefore, this study aimed to develop a methodology to set priorities for the introduction of short-turn buses of bus lines and sections, considering crowding. To achieve this objective, we calculated occupancies and crowding alleviation benefits of existing bus lines overlapping a new short-turn route based on transit card data, before and after the introduction of short-turn strategy. Also, operator and social costs caused by the introduction of short-turn buses were calculated. Those procedures were iterated over bus lines and sections to operate a short-turn service, and a section whose benefit-to-cost ratio (B/C) is the largest in a line was selected to operate a short-turn service in the line. After, priorities of bus lines to introduce short-turn services could be determined based on B/C values, and the optimum total fleet size could be determined when a short-turn strategy is applied in multiple lines.

Development of Inter-Turn Short Circuits Sensor for Rotor Winding of Synchronous Generator (발전기 회전자의 층간단락 감지기 개발)

  • Nam, Jong-Ha;Lee, Seung-Hak;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.307-312
    • /
    • 2002
  • Inter-turn short circuits can have significant effects on a generator and its performance. The Inter-turn short circuits sensor for synchronous generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a shorted- turn test was performed at the Seoinchon combined cycle power plant on gas turbine generator and stim turbine generator. This sensor will be used as a detecting of Inter-turn short circuits for synchronous generator's field winding.

Static and Dynamic Testing Technique of Inductor Short Turn

  • Piyarat, W.;Tipsuwanporn, V.;Tarasantisuk, C.;Kummool, S.;Im, T.Sum
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.281-283
    • /
    • 1999
  • This topic presents an inductor short turn testing. From the rudimentary principles, the quality factor(Q) decreases due to inductor short turn. Frequency response varies because of the variation of circuit inductance and resistance. In general, short turn circuit testing is performed by comparing the ratio of an inductance and resistance of inductor in that particular circuit. An alternative method can be done by considering the response of second order circuit which can give both dynamic and static testing, whereas static testing give an error results not more than 2 turns. For dynamic testing, the result is more accurate, which can test fur the short turn number form 1 turn onward.

  • PDF

Analytic Results for the Double Short Turn Sensor Structure of Rotor Winding in Generators (발전기 회전자권선 단락센서의 이중화구조 실험결과 분석)

  • Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2054-2055
    • /
    • 2008
  • Due to the severe operation environment, the accidents in the rotor winding increase lately. To prevent the rotor's damage from short turn phenomena, research staffs in Korea Electric Power Research Institute develop sensors to detect short turn efficiently. In this paper, we present the double-structured short turn sensor which evluates the healthiness of rotor winding.

  • PDF

Development of Inter-Turn Short Circuits Sensor for Field Winding of Synchronous Generator

  • Nam J-H;Jeon Y-S;Choe G-H;Lee S-H;Jeong S-Y;Yoo B-Y;Ju Y-H;Lee Y-J;Shin W-S
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.56-59
    • /
    • 2001
  • An effective method of detecting inter-turn short circuits on round rotor windings is described. Shorted-turns can have significant effects on a generator and its performance. A method of detecting inter-turn short circuits on rotor windings is described. The approach used is to measure the rate of change of the air-gap flux density wave when the rotor is at operating speed and excitation is applied to the field winding. The inter-turn short circuits sensor for synchronous generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a inter-turn short circuits test was performed at the West-Inchon combined cycle power plant on gas turbine generator and steam turbine generator. This sensor will be used as a detecting of shorted-turn for field winding of synchronous generator. The purpose of this paper is to describe the design and operation of a sensitive inter-turn short circuits detector. In this paper, development of inter-turn short circuits sensor for field winding of synchronous generator and application in a field.

  • PDF

다목적 회항조선 Double 30 ( woo ) Turn 조성법의 개발에 관한 연구 ( On the New Development of Double 30 ( woo ) Turn Maneuvers )

  • Woo, B.G.
    • Journal of Korean Port Research
    • /
    • v.8 no.1
    • /
    • pp.65-74
    • /
    • 1994
  • There are some turn maneuvers, such as hard Round Turn, Turning Short Round, Williamson Turn and Single Turn, of effectively returning a ship back close to the original track in case of emergency situations of man-overboard and intentional delay of port entrance time, and so forth. But the author developed the new turn maneuvers of Double 30 (woo) Turn originally by means of simulation experiments of Full-Mission Shiphandling Simulator. The conclusions of this study are as follows: 1) By comparison of existing Williamson Turn and Turning Short Round this Double 30(woo) Turn is all-weather multipurpose turn maneuvers in some respects, 2) According to simulation experiments this Double 30 (woo) Turn saved approximately 20-35% of total turning time to the original position and reduced maximum advances by 8-10% approximately in comparison to that of Williamson Turn, 3) Except for emergency men-overboard the Reverse Williamson Turn was proposed as a new reverse maneuver of returning a ship back to the original track.

  • PDF

Modeling and Analysis of PMSMs under Inter Turn Short Faults

  • Choi, Jun-Hyuk;Gu, Bon-Gwan;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1243-1250
    • /
    • 2013
  • A model of a permanent magnet synchronous motor (PMSM) with an inter turn short fault is proposed using a deformed flux model. The deformed flux model includes not only the fault winding flux information but also the inductance variation of the healthy winding considering the configuration of the winding distribution. With the deformed flux model and the positive sequence current assumption, the proposed model is derived in the positive and negative sequence synchronous reference frame (SRF). The finite elements method (FEM) simulation is applied to validate the proposed PMSM model with inter turn short fault.

Sensorless Diagnosis Method and Characteristic Analysis of Short-Circuited Turn for Generator Rotor (발전기 회전자의 층간단락 센서리스 진단기법 및 특성 해석)

  • Kim Sun-Ja;Jeon Yoon-Seok;Lee Seung-Hak;Choe Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.210-213
    • /
    • 2003
  • Short-circuited can have significant effects on a generator and its performance. One of effective method detecting inter-turn short circuits on round rotor winding is a method using sensor detecting. But the method needs duplicate design of sensor for characteristic change according to types and forms of generator. Thus rotor shorted-turn diagnosis method without sensor is needed for detecting short turn when generator is driven. Diagnosis method without sensor depend on change of electric property in generator For the reason, this paper presents characteristic analysis of shorted-turns in generator by detecting the output voltage of generator.

  • PDF

Winding Turn-to-Turn Faults Detection of Fault-Tolerant Permanent-Magnet Machines Based on a New Parametric Model

  • Liu, Guohai;Tang, Wei;Zhao, Wenxiang
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.23-30
    • /
    • 2013
  • This paper proposes a parametric model for inter-turn fault detection in a fault-tolerant permanent-magnet (FTPM) machine, which can predict the effect of the short-circuit fault to various physical quantity of the machine. For different faulty operations, a new effective stator inter-turn fault detection method is proposed. Finally, simulations of vector-controlled FTPM machine drives are given to verify the feasibility of the proposed method, showing that even single-coil short-circuit fault could be exactly detected.