• 제목/요약/키워드: Short Module Stack

검색결과 9건 처리시간 0.036초

소형 모듈 스택을 이용한 가정용 연료전지 성능의 실험적 고찰 (An Experimental Study of Short Stack on the Performance of the Proton Exchange Membrane Fuel Cell for the Residential Power generation)

  • 최원석;김용모;유상석;이영덕;홍동진;안국영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.21-24
    • /
    • 2008
  • Proton Exchange Membrane Fuel Cell (PEMFC) is an attractive candidate for residential power generator due to fast start-up and stop, high efficiency, low emission, and high power density. In this study, we employ short module stack to understand the performance of the unit cell of the stack in terms of operating temperatures. To simulate the practical fuel cell stack of residential power generator, the structure and active area of the short module stack is kept the same as that of the practical fuel cell. The results shows that the electric potential of short module stack is different from the number of cells times the potential of unit cell because of cell-to-cell variation.

  • PDF

Development of High Performance LonWorks Based Control Modules for Network-based Induction Motor Control

  • Kim, Jung-Gon;Hong, Won?Pyo;Yun, Byeong-Ju;Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.414-420
    • /
    • 2005
  • The ShortStack Micro Server enables any product that contains a microcontroller or microprocessor to quickly and inexpensively become a networked, Internet-accessible device. The ShortStack Micro Server provides a simple way to add LonWorks networking to new or existing smart devices. . It implements the LonTalk protocol and provides the physical interface with the LonWorks communication. The ShortStack host processor can be an 8, 16, or 32-bit microprocessor or microcontrollers. The ShortStack API and driver typically require about 4kbytes of program memory on the host processor and less than 200 bytes of RAM. The interface between host processor and the ShortStack Micro Server may be a Serial Communication Interface (SCI). The LonWorks control module with a high performance is developed, which is composed of the 8 bit PIC Microprocessor for host processor and the smart neuron chip for the ShortStack Micro Server. This intelligent control board is verified as proceeding the various function tests from experimental system with an boost pump and inverter driving systems. It is also confirmed that the developed control module provides stably 0-10VDC linear signal to the input signal of inverter driving system for varying the induction motor speed. Thus, the experimental results show that the fabricating intelligent board carried out very well the various functions in the wide operating ranges of boost pump system. This developed control module expect to apply to industrial fields to require the comparatively exact control and monitoring such as multi-motor driving system with inverter, variable air volume system and the boost pump water supply systems.

  • PDF

2 모듈 스택을 이용한 SOFC 시스템 운전결과 (Operation Results of the SOFC System Using 2 Sub-Module Stacks)

  • 이태희
    • 한국수소및신에너지학회논문집
    • /
    • 제21권5호
    • /
    • pp.405-411
    • /
    • 2010
  • A 5kW class SOFC cogeneration system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a stack, a fuel reformer, a catalytic combustor, and heat exchangers. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. A 5kW stack was designed to integrate 2 sub-modules. In this paper, the 5kW class SOFC system was operated using 2 short stacks connected in parallel to test the sub-module and the system. A short stack had 15 cells with $15{\times}15 cm^2$ area. When a natural gas was used, the total power was about 1.38 kW at 120A. Because the sub-modules were connected in parallel and current was loaded using a DC load, voltages of sub-modules were same and the currents were distributed according to the resistance of sub-modules. The voltage of the first stack was 11.46 V at 61A and the voltage of the second stack was 11.49V at 59A.

네트워크 기반 유도전동기 제어를 위한 고성능 LonWorks 제어모듈 개발 (Development of High Performance LonWorks Fieldbus Control Modules for Network-based Induction Motor Control)

  • 김중곤;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.319-324
    • /
    • 2005
  • The interface between host processor and the ShortStack Micro Server may be a Serial Communication Interface(SCI). The LonWorks control module with a high performance is developed, which is composed of the 8 bit PIC Microprocessor for host processor and the smart neuron chip for the ShoretStack Micro Server. This intelligent control board is verified as proceeding the various function tests from experimental system with an boost pump and inverter driving systems. It is also confirmed that the developed control module provides stably 0-10VDC linear signal to the input signal of inverter driving system for varying the induction motor speed. Thus, the experimental results show that the fabricating intelligent board carried out very well the various functions in the wide operating ranges of boost pump system. This developed control module expect to apply to industrial fields to require the comparatively exact control and monitoring such as multi-motor driving system with inverter, variable air volume system and the boost pump water supply systems.

  • PDF

A Modularized Charge Equalization Converter for a Hybrid Electric Vehicle Lithium-Ion Battery Stack

  • Park, Hong-Sun;Kim, Chong-Eun;Kim, Chol-Ho;Moon, Gun-Woo;Lee, Joong-Hui
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.343-352
    • /
    • 2007
  • This paper proposes a modularized charge equalization converter for hybrid electric vehicle (HEV) lithium-ion battery cells, in which the intra-module and the inter-module equalizer are Implemented. Considering the high voltage HEV battery pack, over approximately 300V, the proposed equalization circuit modularizes the entire $M^*N$ cells; in other words, M modules in the string and N cells in each module. With this modularization, low voltage stress on all the electronic devices, below roughly 64V, can be obtained. In the intra-module equalization, a current-fed DC/DC converter with cell selection switches is employed. By conducting these selection switches, concentrated charging of the specific under charged cells can be performed. On the other hand, the inter-module equalizer makes use of a voltage-fed DC/DC converter for bi-directional equalization. In the proposed circuit, these two converters can share the MOSFET switch so that low cost and small size can be achieved. In addition, the absence of any additional reset circuitry in the inter-module equalizer allows for further size reduction, concurrently conducting the multiple cell selection switches allows for shorter equalization time, and employing the optimal power rating design rule allows fur high power density to be obtained. Experimental results of an implemented prototype show that the proposed equalization scheme has the promised cell balancing performance for the 7Ah HEV lithium-ion battery string while maintaining low voltage stress, low cost, small size, and short equalization time.

하이브리드 통신을 이용한 항로표지의 원격관리 제어시스템에 관한 연구 (A Study on the Tele-controller System of Navigational Aids Using Hybrid Communication)

  • 전중성;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.842-848
    • /
    • 2011
  • 다중통신을 지원하는 하이브리드 통신 제어보드는 저전력의 8-bit 마이크로콘트롤러인 ATxmega128A1으로 설계하였으며, 마이크로콘트롤러는 다중통신을 위한 모뎀과 GPS 모듈 등을 시리얼 인터페이스 하기 위한 8개의 UART 포트가 갖추어져 있으며, 내부에 2K 바이트의 프로그램 매개변수와 프로그램이 동작하는데 필요한 데이터를 저장할 수 있는 EEPROM과 128K 바이트의 플래시 메모리 및 프로그램이 실행되는 8K 바이트의 SRAM으로 구성되어 있다. 항로표지의 원격 관리를 CDMA, TRS, RF 등 하이브리드 통신을 이용하면 개별 통신 방식별로 음영지역이 존재하는 경우에도, 최적의 통신방식을 선택하여 통신을 수행하게 됨으로써, 통신 음영지역의 해소가 가능하다. 또한 통신장치마다 동일한 데이터 프레임을 사용함으로써 데이터의 호환성을 높였다. 실험은 30일 동안 각 부표에서 매 5분마다 데이터를 취득하였으며, 데이터 수신율은 85 % 이상을 보였다.

애드 혹 네트워크 기반의 무선 영상 관측용 임베디드 시스템의 두 가지 설계 기법들 (Two Design Techniques of Embedded Systems Based on Ad-Hoc Network for Wireless Image Observation)

  • 이용업;송창영;박정욱
    • 한국통신학회논문지
    • /
    • 제39A권5호
    • /
    • pp.271-279
    • /
    • 2014
  • 이 논문에서는 임시 애드 혹 네트워크 기반 무선 영상 관측이 가능한 임베디드 시스템의 두 가지 설계 기법을 제안하고 구현한다. 첫 번째 방법은 실시간에 가까운 단기 관측 적용 서비스를 위한 임베디드 시스템 설계 기법에 기반을 둔 것으로 $160{\times}128$ 영상을 최대 1 fps(초당 프레임) 속도의 무선 영상 전송 능력을 가지며, 영상처리 기능이 내장된 특수한 원격 관측노드를 가진다. 두 번째 방법은 일반 무선 영상 장기 관측을 위한 임베디드 시스템을 사용하며, 1/3 fps 무선 영상 전송 능력을 가지고, 영상처리가 내장된 시스템 제어기, 주노드, 관측노드로 구성이 된다. 제안 시스템은 저전력 근거리 양방향 디지털 통신 방식으로 잘 알려진 애드 혹 무선 네트워크를 사용하며, 제안 시스템의 하드웨어는 일반 개발 보드, 소형 카메라, 그리고 시스템 제어를 위해 PC로 구성되며, 지그비 스택에 기반을 둔 임베디드 소프트웨어와 시스템 제어용 사용자 인터페이스 소프트웨어가 개발되고 구현된 하드웨어 모듈에 내장되어 동작된다. 또한 프로토콜 분석기를 사용해 무선 환경 분석을 수행한다.

전파 음영지역 해소를 위한 항로표지관리용 하이브리드 통신 시스템에 관한 연구 (A study on the hybrid communication system to remove the communication shadow area for controller system of navigational aids)

  • 전중성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.409-417
    • /
    • 2013
  • 하이브리드 통신을 지원하는 하이브리드 통신 신호처리 제어보드는 저전력의 8-bit 마이크로콘트롤러인 ATxmega128A1으로 설계하였으며, 마이크로콘트롤러는 하이브리드 통신을 위한 모뎀과 GPS 모듈 등을 직렬 인터페이스하기 위해 8개의 UART 포트가 갖추어져 있으며, CLI(Command Line Interpreter) 프로그램은 각 포트의 인터페이스를 사용자 환경에 맞게 설정할 수 있으며, 내부에 2K 바이트의 프로그램 매개변수와 프로그램이 동작하는데 필요한 데이터를 저장할 수 있는 EEPROM과 128K 바이트의 플래시 메모리 및 프로그램이 실행되는 8K 바이트의 SRAM으로 구성되어 있다. 항로표지의 원격 관리를 VHF, CDMA, TRS 통신의 경로설정 최적화(Path Optimization) 기능을 갖는 하이브리드 통신을 이용하면 개별 통신 방식별로 음영지역이 존재하는 경우에도, 최적의 통신방식을 선택하여 통신을 수행하게 됨으로써, 통신 음영지역의 해소가 가능하다. 또한 통신장치마다 동일한 데이터 프레임을 사용함으로써 데이터의 호환성을 높였다. 실험은 30일 동안 각 부표에서 매 5분마다 데이터를 취득하였으며, 데이터 수신율은 99.4 % 이상을 보였다.

방사성의약품 합성에서 발생하는 방사성기체의 효율적 차단 (An Effective Block of Radioactive Gases for the Storage During the Synthesis of Radiopharmaceutical)

  • 지용기;김동일;김시활;원문희;최성욱;최춘기;석재동
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.126-130
    • /
    • 2012
  • 방사성의약품 제조 시 휘발성 기체의 경우에 완전 차폐가 되지 않고, Hot cell 외부로 그리고 배기덕트를 통해 작업자에게 외부피폭은 물론 호흡을 통해 내부피폭을 가져오게 한다. 처음에는 Hot cell 자체의 배출구를 막아서 방사성기체를 차단하려하였으나 장치에 맞는 기체 밀폐형 댐퍼의 제작이 어렵고, 크기가 맞지 않아서 설치 후에 여전히 문제점이 개선되지 않았다. 그러나 Tedlar gas sampling bag의 사용으로 합성 장치의 가스 배출구를 연결하여 방사성 기체를 저장하고 10반감기가 지난 후에 배출함으로써 작업자의 피폭을 확연히 줄이게 되었으며 $^{18}F$ 방사성 기체는 Hot cell 배출구에 활성탄 필터를 연결하고 최종 배출구에 2차 활성탄 필터를 사용함으로써 배출되는 방사능 농도를 90% 이상 줄여주었다. 단 반감기의 핵종인 경우는 위와 같은 경우를 이용하여 다음날 작업을 할 수 있지만 반감기가 긴 핵종들 같은 경우는 다음날 처리 할 수 없는 문제점들이 발생한다. Decay tank의 추가적인 문제점들을 보완하거나 기체상의 여러 방사성 입자들을 포집 할 수 있는 물질들이 만들어져야 할 것이다. 현재 우리나라는 최종 배출 공기 중 방사능 농도만을 규제하고 있으나 유럽 같은 경우 일일 배출 양과 연간 배출도 규제를 하고 있다. 방사성의약품 합성 시 발생하는 많은 방사성 물질들을 보다 효과적으로 친환경적으로 처리할 수 있는 여러 연구들이 이루어져야 할 것이다.

  • PDF