• 제목/요약/키워드: Shore hardness

검색결과 63건 처리시간 0.024초

쇼어경도표준의 확립에 관한 연구 (A Study on the Establishment of Shore Hardness Standards)

  • 방건용;탁내형;봉하헌
    • 열처리공학회지
    • /
    • 제15권3호
    • /
    • pp.127-135
    • /
    • 2002
  • Shore hardness test was developed in 1906 to overcome the limit of Brinell hardness test. However, the detailed requirements on the tester was not clearly specified except the scale, i.e., 100 HS for high carbon steel and 10 HS for soft brass. As a result, the shore hardness was used for quite long time without well established standards. For the establishment of hardness standards, standard tester, standard procedure, and standard hardness block must be provided. So far the standard of Shore hardness was maintained by correlating Shore hardness scale to Vickers hardness through converting equation. This is the so called converted Shore hardness and it is not the true Shore hardness standard strictly. In this paper, the possibility of establishing Shore hardness standard based on the Shore standard hardness tester is reported.

부가중합형 실리콘 교합인기재의 탄성 특성 (Elastic properties of addition silicone interocclusal recording materials)

  • 이영옥;김경남
    • 한국치위생학회지
    • /
    • 제12권3호
    • /
    • pp.513-520
    • /
    • 2012
  • Objectives : In this study, contact angle and shore D hardness were measured, and a shark fin test was conducted after selecting five addition silicon(Blu-Mousse, BM; EXABITE II, EX; PERFECT, PF; Regisil$^{(R)}$ Rigid, RE; Silagum$^{(R)}$, SI) in order to figure out the properties of elastomeric interocclusal recording materials and reduce errors at interocclusal recording. 8) Methods : A contact angle was measured using a contact angle analyzer. After placing a drop of liquid on the surface of the specimens of interocclusal recording materials, a contact angle was photographed with a CCD camera on the equipment. In terms of a shark fin test, interocclusal recording materials were mixed for the time proposed by the manufacturer and inserted into the split ring of the Shark fin device. Twenty (20) seconds exactly, a metal rod was removed to make the materials slowly absorbed. Once they hardened, fin height was measured with a caliper after separating molds and trimming the specimens. The shore D hardness was measured with a shore D hardness tester(Model HPDSD, Hans Schmidt & Co. Gmbh, Germany) in sixty (60) minutes after fabricating specimens. In each experiment, five specimens, mean and standard deviation were calculated. A one-way ANOVA test was performed at the p>0.05 level of significance. In terms of correlation among the tests, Pearson correlation coefficient was estimated. For multiple comparison, Scheffe's test was carried out. Results : A contact angle was the highest in EX with $99.23^{\circ}$ (p<0.05) while the result of the shark fin test was the longest in RE with 5.45mm. SI was the lowest (0.27mm) with statistical significance. Among the interocclusal recording materials, significant difference was observed in terms of means (p<0.05). The shore D hardness was the highest in SI with 31.0 while RE was significantly low with 16.4 (p<0.05). Among the materials, statistically significant difference was observed in terms of means when compared to the rest materials (RE), BM, RE and SI (PF and EX) and the remaining materials (BM and SI) (p<0.05). In terms of correlations among the tests, a negative correlation occurred between shore D hardness and shark fin test(r=-0.823, p=0.000). Conclusions : According to the study above, it is necessary to understand the properties of interocclusal recording materials and consider contact angle, shark fin test and properties of shore D hardness to select appropriate materials.

Assessing Commercial CLEANBOLUS Based on Silicone for Clinical Use

  • Son, Jaeman;Jung, Seongmoon;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.159-164
    • /
    • 2021
  • Purpose: We investigated the properties of CLEANBOLUS based on silicone with suitable characteristics for clinical use. Methods: We evaluated the characteristics of CLEANBOLUS and compared the results with the commercial product (Super-Flex bolus). Also, we conducted physical evaluations, including shore hardness, element composition, and elongation break. Transparency was investigated through the measured absorbance within the visible region (400-700 nm). Also, dosimetric characteristics were investigated with surface dose and beam quality. Finally, the volume of unwanted air gap was investigated based on computed tomography images for breast, chin, and nose using Super-Flex bolus and CELANBOLUS. Results: CLEANBOLUS showed excellent physical properties for a low shore hardness (000-35) and elongation break (>1,000%). Additionally, it was shown that CLEANBOLUS is more transparent than Super-Flex bolus. Dosimetric results obtained through measurement and calculation have an electron density similar to water in CLEANBOLUS. Finally, CLEANBOLUS showed that the volume of unwanted air gap between the phantom and each bolus is smaller than Super-Flex bolus for breast, chin, and nose. Conclusions: The physical properties of CLEANBOLUS, including excellent adhesive strength and lower shore hardness, reduce unwanted air gaps and ensure accurate dose distribution. Therefore, it would be an alternative to other boluses, thus improving clinical use efficiency.

수치해석을 이용한 냉장고용 유리선반 성형용 인서트 금형의 개선 (Improvement of Insert Molding for Refrigerator Glass Shelves Using Numerical Analysis)

  • 한성렬
    • 한국기계가공학회지
    • /
    • 제15권6호
    • /
    • pp.50-57
    • /
    • 2016
  • Refrigerator glass shelves are manufactured by Insert Injection Molding. The current process of injection of glass into the mold induces movement of the core, on urethane springs. Defects in the product can result from too low a force being transmitted from the springs. To solve this problem, the force on the moving core and the injection molding pressure were subjected to numerical analysis. Based on this, the number of urethane springs as well as their hardness was changed to improve the situation. The number of springs was changed from 6 to 4. The diameter of the springs was increased from ${\emptyset}75$ to ${\emptyset}100$, and the hardness was increased from 70 (shore A) to 90 (shore A). These improvements caused the force on the molding core to increase by approximately 65,442 N. The proportion of defects decreased by 66%.

국내산(國內産) 대리석(大理石)의 지질공학적(地質工學的) 특성(特性) (Engineering Geological Properties of Some Domestic Marbles)

  • 정영욱;전효택
    • 자원환경지질
    • /
    • 제23권4호
    • /
    • pp.411-424
    • /
    • 1990
  • Mechanical, physical and petrographic properties of seventeen marble specimens collected from ten marble mines in Korea were investigated. Studied marbles were mainly composed of calcite, dolomite, and various amounts of serpentine, tremolite, olivine, quartz and opaque minerals. Complete and sutured textures were dominant. Compressive strength measured normal to the bedding plane is larger almost two times than that measured parallel to the bedding plane. From the results of Shore hardness test on marbles, water content was an important factor to decrease Shore hardness values. Engineering geological properties, especially, compressive strength, Young's modulus, wear resistance and water absorption could be controlled by the presence of quartz, and the type of marble texture. Water absorption-porosity, compressive strength-Young's modulus, and impact strength index-Los Angeles abrasion couples show good correlation. According to the comparative utility as commercial stone, it could be concluded that marbles from the Banglim mine, Songbo mine, Kwangdeok mine and Bongjeong mine were superior to that of other studied marbles.

  • PDF

달리기 속도의 증가에 따른 운동화 중저의 경도와 신발바닥의 두께가 신발의 볼 굴곡각도에 미치는 영향 (The Influence of Midsole Hardness and Sole Thickness of Sport Shoes on Ball Flex Angle with the Increment of Running Velocity)

  • 곽창수;목승한;권오복
    • 한국운동역학회지
    • /
    • 제15권4호
    • /
    • pp.153-168
    • /
    • 2005
  • The purposes of this study were to determine the influence of midsole hardness and sole thickness of sports shoes on ball flex angle and position with increment of running velocity. The subjects employed for this study were 10 college students who did not have lower extremity injuries for the last one year and whose running pattern was rearfoot striker of normal foot. The shoes used in this study had 3 different midsole hardness of shore A 40, shore A 50, shore A 60 and 3 different sole thickness of 17cm, 19cm, 21cm. The subjects were asked to run at 3 different speed of 2.0m/sec, 3.5m/sec, 5.0m/sec and their motions were videotaped with 4 S-VHS video cameras and 2 high speed video cameras and simultaneously measured with a force platform. The following results were obtained after analysing and comparing the variables. Minimum angle of each ball flex position were increased with the increment of running velocity and shoe sole thickness(P<0.05), but mid-sole hardness did not affect minimum ball flex angle. The position which minimum angle was shown as smallest was 'D'. Midsole hardness and sole thickness did not affect time to each ball flex minimum angle, total angular displacement of ball flex angle, and total angular displacement of torsion angle(P<0.05). The position which minimum angle was appeared to be earliest was similar at walking velocity, and E and F of midfoot region at running velocity. Total angular displacement of ball flex position tended to increase as shifted to heel. It was found that running velocity had effects on ball flex angle variables, but shoe sole thickness partially affected. It would be considered that running velocity made differences between analysis variables at walking and running when designing shoes. Also, it was regarded that shoes would be developed at separated region, because ball flex angle and position was shown to be different at toe and heel region. It is necessary that midsole hardness and thickness required to functional shoes be analyzed in the further study.

팽창질석 첨가에 따른 전선용 실리콘 고무의 난연 및 트래킹 특성에 관한 연구 (A Study on Flame Retardancy and Tracking Properties of Expanded Vermiculite Added Silicon Rubber for Wire)

  • 박승호;이성일
    • 한국전기전자재료학회논문지
    • /
    • 제32권3호
    • /
    • pp.213-218
    • /
    • 2019
  • In this study, a high-temperature vulcanizing (HTV) method was used to achieve a shore a hardness of 70. The basic base was composed of 60% silicon gum (GUM) which is a high-viscosity polymer, 30% fumed silica (FS), and 5% of plasticizer. The GUM and FS were mixed well with less than 1% silane to improve rubber strength. Expanded vermiculite was added as a filler at 10%, 15%, and 20%. The curing conditions were $170^{\circ}C$ for 10 min and a molding method was applied. We report herein, the results of inorganic analysis and flame-retardant and tracking tests on the expanded vermiculite. The flame retardance and tracking test outcomes for a shore a hardness of 70 were found to be optimal when the expanded vermiculite content was 10%.

Physical and electrical properties of PLA-carbon composites

  • Kang Z. Khor;Cheow K. Yeoh;Pei L. Teh;Thangarajan Mathanesh;Wee C. Wong
    • Advances in materials Research
    • /
    • 제13권3호
    • /
    • pp.211-220
    • /
    • 2024
  • Polylactic acid or polylactide (PLA) is a biodegradable thermoplastic that can be produced from renewable material to create various components for industrial purposes. In 3D printing technology, PLA is used due to its good mechanical, electrical, printing properties, environmentally friendly and non-toxic properties. However, the physical properties and excellent electrical insulation properties of PLA have limited its application. In this study, with the carbon black (CB) as filler added into PLA, the lattice spacing and morphology were investigated by using X-ray diffraction (XRD) and scanning electron microscope (SEM), respectively. The physical properties of PLA-carbon composite were evaluated by using tensile test, shore D hardness test and density and voids measurement. Impedance test was conducted to investigate the electrical properties of PLA-Carbon composites. The results demonstrate that the inclusion of carbon black as filler enhances the physical properties of the PLA-carbon composites, including tensile properties, hardness, and density. The addition of carbon black also leads to improved electrical conductivity of the composites. Better enhancement toward the electrical properties of PLA-carbon composites is observed with 1wt% of carbon black in N774 grade. The N550 grade with 2wt% of carbon black shows better improvement in the physical properties of PLA-carbon composites, achieving 10.686 MPa in tensile testing, 43.330 in shore D hardness test, and a density of 1.200 g/cm3 in density measurement. The findings suggest that PLA-carbon composites have the potential for enhanced performance in various industrial applications, particularly in sectors requiring improved physical and electrical properties.

경주 남산화강암에 대한 강화제 처리 전후의 물리적 특성변화 연구 (Studies on Physical Characterization of Gyeongju Namsan Granite after Treated with Consolidants)

  • 김성호;원종옥;강용수;장윤득;김사덕;김정진
    • 보존과학회지
    • /
    • 제25권3호
    • /
    • pp.245-256
    • /
    • 2009
  • 경주 남산화강암에 대한 강화제 처리 전후의 물리적 특성변화 연구를 위하여 강화제 처리 한 후 쌍안실체현미경관찰, 초음파속도, 쇼어경도, 색도측정 등을 실시하였다. 실험에 사용한 강화제는 세종대학교에서 개발한 6종류 35wt% Silicate Nonparticle/100%1T1G (Nonparticle), 3%POSS-SO1455/97%1T1G (3%POSS1455), POSS-SO1458/97%1T1G(3%POSS1458), 3%7nm/97%1T1G (3%7nm), 3%16nm/97%1T1G(3%16nm), 3%40nm/97%1T1G(3%40nm)와 상품화된 제품인 2개 Wacker사의 Silres BS OH-100, Kulba사의 Unil Sandsteinfestiger OH-100으로 총 8가지 종류이다. 강화제 처리후 암석의 표면색깔은 강화제의 종류에 따라 약간의 차이는 있으나 대부분 어두워졌으며 시간이 지남에 따라 원암과 유사한 색깔을 나타낸다. 강화제 처리 후 초음파속도와 쇼어경도는 증가하였다.

  • PDF

달리기 시 운동화 중저의 경도가 신발굴곡각도의 크기에 미치는 영향 (The Influence of Midsole Hardness of Running Shoes on Shoes Flex Angle during Running)

  • 목승한;곽창수;권오복
    • 한국운동역학회지
    • /
    • 제14권2호
    • /
    • pp.85-103
    • /
    • 2004
  • This study was conducted to determine what effects would the midsole hardness of running shoes have on shoe flex angle and maximum propulsive force. Furthermore, the relationship between the shoes flex angle and maximum propulsive force was elucidated in order to provide basic data for developing running shoes to improve sports performances and prevent injuries. The subjects employed in the study were 10 college students majoring in physical education who did not have lower limbs injuries for the last one year and whose running pattern was rearfoot strike pattern of normal foot. The shoes used in this study had 3different hardness, shore A 40(soft), 50(medium) and 60(hard). The subjects were asked to run at a speed of $4{\pm}0.08m/sec$, and their movements were videotaped with 2 S-VHS video-cameras and measured with a force platform. And the following results were obtained after analyzing and comparing the variables. 1. Although the minimum angle of shoes flex angle was estimated to appear at SFA4, it appeared at SFA2 except in those shoes with the hardness of 40. 2. The minimum angle of shoes flex angle was $145.1^{\circ}$ with barefoot. Among the shoes with different hardness, it was the smallest when the hardness was 50 at $149.9^{\circ}$. The time to the minimum angle was 70.7% of the total ground contact time. 3. Maximum propulsive force according to midsole hardness was the largest when the hardness was 50 at $1913.9{\pm}184.3N$. There was a low correlation between maximum propulsive force and shoes flex angle.