Study on the Off-design Performance on a Plug Nozzle with Variable Throat Area

  • Azuma, Nobuyuki;Tanatsugu, Nobuhiro;Sato, Tetsuya;Kobayashi, Hiroaki;Hongo, Motoyuki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.644-648
    • /
    • 2004
  • In the present study were examined numerically and experimentally the off-design performance characteristics on an axisymmetric plug nozzle with variable throat area. In this nozzle concept, its throat area can be changed by translating the plug into the axial direction. First, a mixed-expansion plug nozzle, in which two expansion parts are arranged both inside and outside, was designed by means of the method of characteristics. Second, the CFD analysis was verified by the cold-flow wind tunnel test. Third, its performance characteristics were evaluated over a wide range of pressure ratio from half to double throat area through the design point, using the CFD code verified by the wind tunnel tests. It was made clear from the study that not so critical thrust efficiency losses were found and the maximum thrust efficiency loss was at most approximately 5 % under off-design conditions without external flow. This result shows that a plug nozzle can give the altitude compensation even under off-design geometry operations. However, shock waves were observed in the inner expansion part under the doubled throat area operation and thus some thermal problems may be caused on the plug surface. Furthermore, collapse of cell structure on the plug surface was observed with external flow (around Mach number 2.0) as it became lower pressure ratio below the design point and the fact may result in big efficiency loss regardless of geometrical configuration.

  • PDF

The development for flooding prevention apparatus of electrical equipment using air pressure (공기압을 이용한 전기설비 침수 방지 장치 개발에 관한 연구)

  • Kim, Gi-Hyun;Jean, Hyun-Jae;Lee, Sang-Ick;Bae, Suk-Myong;Lee, Jae-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.281-284
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment(Pad-mounted Transformer and Switch). In case of installing the power equipment at flood danger territory, we are necessary to the product development, the product is that water does not come in the inside the power equipment. Product of pressure maintaining are established on the basic frame and sensor operates at the flooding occurrence and is maintained a shutting tightly structure and it is a method. The product which is produced the reliability of the product it confirmed a flooding yes or no from the condition which puts in the water tank and it verified. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation and a security of the flood protection product.

  • PDF

Improvement of Oxidative Resistance for C/C Composite Coated (졸-겔법으로 알루미나를 도포한 탄소/탄소 복합재의 산화 억제효과)

  • Ju, Hyeok-Jong;Choe, Don-Muk;Kim, Yeong-Guk;Gwon, Ho-Gil
    • Korean Journal of Materials Research
    • /
    • v.3 no.4
    • /
    • pp.372-380
    • /
    • 1993
  • In order to improve the oxidative resistance of carbon/carbon composites, aluminium-isopropoxide and aluminium-tri-sec-butoxide sol were coated on the surface of 2D--carbon/carbon composiles and the effects uf coating were investigated. The effects of oxidative resistance were dominant in the case of catalyst/alkoxide mole ratio, 0.07, and $H_2O$/alkoxide mole ratio, 100. Through the dynamic TGA analysis with the heating rate of 20%/min, oxidative initiation tempera~ ture was enhanced about $80^{\circ}C$. The oxidative resistance effects of alkoxide sol were improved according to the times of coating. Also the 20% weight loss time of coated samples by TGA analysis was 20% better than that of un~ coated samples. The thickness of 1^{st} coated layer was about 3${\mu}$m and that of $2^{nd}$ and $3^{nd}$ coated layers was about respectively 4~5${\mu}$m and the weight loss were increased with the increasing of thermal shock test times.

  • PDF

The study of aerodynamic characteristics to design of optimum jetvane (제트베인 최적 설계를 위한 공기역학 특성 연구)

  • 신완순;길경섭;이택상;박종호;김윤곤
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.1
    • /
    • pp.26-33
    • /
    • 2001
  • Thrust vector control system is control device which is mounted exit of the nozzle to generate pitch, yaw and roll directional force by deflecting flow direction of the supersonic jet from the nozzle. By obtaining control force, jetvane which is exposed in jet flow is working thermal and aerodynamic load. Axial thrust loss and side thrust is affected by shock patterns and interactions between jetvanes according to jetvane geometry and turning angle. In this study, we designed 6 types of jetvane to evaluate pitch, yaw and roll characteristics of ietvane in supersonic flow, and perform the cold flow test in range of turning angles of jetvanes between $0^{\cire}$ and $25^{\cire}$ by $5^{\cire}$ respectively. Also, calculation is going side by side to analyse flow interaction. Results show that there is no interactions between jetvanes upto turning angle 20$^{\circ}$, chord and lead length ratio is very important parameter to aerodynamic performance and maximum thrust loss is appeard to 17% of axial thrust in roll directional control.

  • PDF

Countermeasures for Flood Protection of Power Facility at Substation and Ground (수변전실 및 지상 전력기기 침수방지 대책에 관한 연구)

  • Kim, Gi-Hyun;Choi, Myeong-Il;Bae, Suk-Myong;Lee, Jae-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.78-84
    • /
    • 2008
  • Inundation of substation and ground power equipment broke out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical facility. So we researched the installation situation of substation and power equipment and inundation loss at Flood Danger Area. And we analyzed refutation or law relating to the flood protection counterplan of US, England Australia. We present flood protection countermeasures by survey and analyzing the internal standard and his paper will be used to resent a reform proposal of electrical feinted law about flood protection.

Design of TE10 to TEM mode convertor for W-band radial power combiner (W밴드 radial 전력 결합기용 TE10-TEM 모드 변환기 설계)

  • Young-Gon Kim;Myung-Hun Yong;Han-Chun Ryu;Se-Hoon Kwon;Seon-Keol Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.41-46
    • /
    • 2023
  • Design of W-band TE10 to TEM mode converter for radial power combiner is proposed in this paper. The proposed structure is used with generally available pin to realize TEM mode and is designed to convert TE10 to TEM mode gradually using 2-step impedance transformer and back short. The pin of proposed mode converter is well bonded to the housing so that environment conditions such as vibration or shock are not affected. The proposed mode converter, in a back-to-back configuration, has less than 1.55 dB insertion loss and more than 10 dB return loss from 92.5 GHz to 97.7 GHz. Proposed converter is expected compact radar and various applications requiring for high power and stable environment conditions.

[Fe II] $1.64{\mu}m$ Outflow Features around Ultracompact H II Regions in the First Galactic Quadrant

  • Shinn, Jong-Ho;Kim, Kee-Tae;Lee, Jae-Joon;Lee, Yong-Hyun;Kim, Hyun-Jeong;Pyo, Tae-Soo;Koo, Bon-Chul;Kyeong, Jaemann;Hwang, Narae;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.68.2-69
    • /
    • 2015
  • We present [Fe II] $1.644{\mu}m$ features around ultracompact H II regions (UCHIIs) found on a quest for the "footprint" outflow features of UCHIIs -the features produced by outflowing materials ejected during an earlier, active accretion phase of massive young stellar objects (MYSOs). We surveyed 237 UCHIIs in the first Galactic quadrant, employing the CORNISH UCHII catalog and UWIFE data, which is an imaging survey in [Fe II] $1.644{\mu}m$ performed with UKIRT-WFCAM under ~0.''8 seeing conditions. The [Fe II] features were found around five UCHIIs. We interpret the [Fe II] features to be shock-excited by outflows from YSOs and estimate the outflow mass-loss rates from the [Fe II] flux which are ${\sim}1{\times}10^{-6}-4{\times}10^{-5}M{\odot}yr^{-1}$. We propose that the [Fe II] features might be the "footprint" outflow features, but more studies are required to clarify whether or not this is the case. This is based on the morphological relation between the [Fe II] and 5 GHz radio features, the outflow mass-loss rate, the travel time of the [Fe II] features, and the existence of several YSO candidates near the UCHIIs.

  • PDF

Design of W-band 12-way radial power combiner (W-밴드 12-way radial 전력 결합기 설계)

  • Young-Gon Kim;Hyo-Chul Kim;Heung-Rae Cho;Han-Chun Ryu;Se-Hoon Kwon;Seon-Keol Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.3
    • /
    • pp.21-26
    • /
    • 2024
  • Design and fabrication method of W-band 12-way radial power combiner is proposed in this paper. The proposed structure is used with TE10 to TEM mode converter, which is realized using 2-step impedance transformer. The pin structure for mode converter is well bonded to the housing so that environment conditions such as vibration or shock are not affected. Proposed W-band power combiner has less than 0.7 dB insertion loss and more than 13 dB return loss from 88 GHz to 98 GHz. The measured output isolations between each other are greater than 7.5 dB from 82 to 100 GHz and phase differences are less than 10 degree from 88 to 96 GHz. Proposed power combiner is expected compact radar and various applications requiring for high power and stable environment conditions.

A Cilnical Study on the Aspect of ' Hwa ' in Hwabyung Patients (홧병 환자에게 나타나는 화의 양상에 관한 연구)

  • Eom Hyo-Jin;Kim Jong-Woo;Whang Wei-Wan
    • Journal of Oriental Neuropsychiatry
    • /
    • v.8 no.1
    • /
    • pp.141-150
    • /
    • 1997
  • A clinic study was carried out on 83 neuropsychiatric outpatients who visited 'Hwabyung Clinic' in Oriental Hospital of Kyung Hee University from July 1 in 1996, in order to study clinical research and the aspect of 'Hwa'. 1. Onset of stress that causes of Hwabyung was 14.23 years ago and onset of symptoms were 6.39 years ago. Hwabyung patients were maintaining their marital state and were under the same stress that was thought to be the chief causes of the Hwabyung..3. Familiar troubles including their spouse were the main cause of the Hwabyung, which suggested that prolonged trobles were more important rather than sudden emotional shock, and it was obvious that the patients were recognizing the predisposing factors of Hwabyung.5. The emotional state which led to Hwabyung and the present state caused by Heabyung were complicated very much. Feeling being mortified, anger and resentment were gradually changed into anxiety, irritability, depression and loss of interest.6. The somatic symptoms of Hwabyung were flushing, insomnia, hradache, dizziness, and oppressed.7. The feeling of flushing were whole body, front of the body and upper of the body.

  • PDF

Transcriptome and Small RNAome Analyses Reveal the Association of pre-harvest Sprouting and Heat Stress Response in Rice (Oryza sativa L.)

  • Minsu Park;Woochang Choi;Sang-Yoon Shin;Yujin Kweon;Jihyun Eom;Minsun Oh;Chanseok Shin
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2023.04a
    • /
    • pp.157-157
    • /
    • 2023
  • Pre-harvest sprouting (PHS) in rice (Oryza sativa L.) is one of the main problems associated with seed dormancy. PHS causes yield loss and reduction of grain quality under unpredictable humid conditions at the ripening stage, thus affecting the economic value of the rice crop. To resolve this issue, it is important to understand the molecular mechanism underlying seed dormancy in rice. Recent studies have shown that seed dormancy is affected by a large number of genes associated with plant hormones. However, the effect of heat stress on seed dormancy and plant hormones is not well understood. In this study, we compared the PHS rate as well as the transcriptome and small RNAome of the seed embryo and endosperm of two different accessions of rice, PHS-susceptible rice (low dormancy) and PHS-resistant rice (high dormancy) under three different maturation stages. We identified and verified the candidate genes associated with seed dormancy and heat stress-related responses in rice using quantitative real-time PCR. We newly discovered hormone-related genes, heat shock protein-related genes, and miRNAs potentially involved in PHS. These findings provide a foundation for understanding the dynamics of transcriptome and small RNAome of hormone- and heat stress-related genes, which affect PHS during seed maturation.

  • PDF