• 제목/요약/키워드: Shock Sensor

검색결과 82건 처리시간 0.034초

Recommendations on dynamic pressure sensor placement for transonic wind tunnel tests

  • Yang, Michael Y.;Palodichuk, Michael T.
    • Advances in aircraft and spacecraft science
    • /
    • 제6권6호
    • /
    • pp.497-513
    • /
    • 2019
  • A wind tunnel test was conducted that measured surface fluctuating pressures aft of a ramp at transonic speeds. Dynamic pressure test data was used to perform a study to determine best locations for streamwise sensor pairs for shocked and unshocked runs based on minimizing the error in root-mean-square acceleration response of the panel. For unshocked conditions, the upstream sensor is best placed at least 6.5 ramp heights downstream of the ramp, and the downstream sensor should be within 2 ramp heights from the upstream sensor. For shocked conditions, the upstream sensor should be between 1 and 7 ramp heights downstream of the shock, with the downstream sensor 2 to 3 ramp heights of the upstream sensor. The shock was found to prevent the passage coherent flow structures; therefore, it may be desired to use the shock to define the boundary of subzones for the purpose of loads definition. These recommendations should be generally applicable to a range of expansion corner geometries in transonic flow provided similar flow structures exist. The recommendations for shocked runs is more limited, relying on data from a single dataset with the shock located near the forward end of the region of interest.

홉킨슨 압력봉(Hopkinson pressure bar)을 이용한 동적 충격센서 보정기술 연구 (A Study on the Calibration Method for Dynamic Shock Sensor Using Hopkinson Pressure Bar System)

  • 오세욱;민경조;조상호
    • 화약ㆍ발파
    • /
    • 제38권1호
    • /
    • pp.23-29
    • /
    • 2020
  • 발파나 충격과 관련된 연구에서 충격센서를 이용한 하중 및 진동의 계측이 널리 사용되고 있다. 하지만 대부분의 충격센서는 고가이며 외부로부터의 손상에 대해 보호할 필요성이 존재한다. 본 연구에서는 충격센서의 외부 구조적 변화에 따른 계측 대상 매질로부터 입사되는 하중정보의 왜곡현상을 보정할 수 있는 방법에 대해 고찰하였다. 홉킨슨 압력봉 시스템을 이용해 충격센서로 전달되는 충격가속도를 산출하였으며, 이와 동시에 충격진동의 감쇠를 야기하는 센서 홀더를 고안 및 적용하여 센서의 출력 값에 대한 비교분석을 수행하였다. 결과적으로 센서에 적용된 외부 구조적 변화가 센서의 진동운동 자체를 왜곡시키는 비선형 거동이 아닌 경우 본 방법을 통한 충격센서 보정기술이 합리적으로 작용할 수 있을 것으로 판단하였다.

수중폭발에 의한 원통형 배열센서의 구조 응답 및 안정성 해석 (Structural Response and Reliability of a Cylindrical Array Sensor due to Underwater Explosion)

  • 전수홍;홍진숙;정의봉;서희선;조요한
    • 한국소음진동공학회논문집
    • /
    • 제22권1호
    • /
    • pp.81-87
    • /
    • 2012
  • This paper establishes a modeling and simulation procedure for structural response and reliability of a cylindrical array sensor on submarines under the shock generated by underwater explosion. The structural reliability of SONAR is important because the submarine could get out of combat ability by the structural damage of the SONAR upon explosion. A cylindrical array sensor was first modeled using the finite element method. Modal analysis was then performed for the check of the reliability of the modeling. The shock resistance simulations were performed for the responses to the structural shock waves and for the responses to the directly applied underwater shock waves, according to BV-043 and MIL-STD-901D, respectively. The stresses of the structure were evaluated with von-Mises scheme. Vulnerable regions were exposed through mapping the maximum stress to the structural model. Maximum stress of the SONAR was compared with the yield stress of the material to examine the structural reliability.

사물인터넷(IoT) 기반의 무인 택배함 시스템 개발 (Development of an IoT-based Unmanned Home-Delivery Box System)

  • 박찬희;강현태;강창순
    • 한국IT서비스학회지
    • /
    • 제16권2호
    • /
    • pp.129-138
    • /
    • 2017
  • This paper is concerned with an Internet of Things (IoT)-based unmanned home-delivery box system, in which the system is developed with a prototype using a weight sensor, shock sensor, the Arduino and Raspberry-Pi of open-source hardware platforms. The developed system provides several functions such as a safe storage means, prevention of delivery-theft, and remote control of the home-delivery box, etc. Specifically, the system recognizes the arrival of goods by detecting the weight of deliveries and sends the arrived message of deliveries to the recipient' smartphone, and also controls (i.e., open and close) the locker of the unmanned home-delivery box system remotely with the smartphone. Furthermore, the developed system provides automatically a warning alarm around the unmanned home-delivery box when an external shock is applied to the home-delivery box, and sends a message on the shock to the recipient' smartphone. The major functions of the developed home-delivery box system have been verified in a realistic environment, and confirmed to work well. With the application of the developed home-delivery box system to the homes and offices where recipients are always not to stay, it is expected to significantly improve the safety of delivered goods as well as to effectively prevent the delivery operatives posing as a crime.

Sensor placement strategy for high quality sensing in machine health monitoring

  • Gao, Robert X.;Wang, Changting;Sheng, Shuangwen
    • Smart Structures and Systems
    • /
    • 제1권2호
    • /
    • pp.121-140
    • /
    • 2005
  • This paper presents a systematic investigation of the effect of sensor location on the data quality and subsequently, on the effectiveness of machine health monitoring. Based on an analysis of the signal propagation process from the defect location to the sensor, numerical simulations using finite element modeling were conducted on a bearing test bed to determine the signal strength at several representative sensor locations. The results showed that placing sensors closely to the machine component being monitored is critical to achieving high signal-to-noise ratio, thus improving the data quality. Using millimeter-sized piezoceramic plates, the obtained results were evaluated experimentally. A comparison with a set of commercial vibration sensors verified the developed structural dynamics-based sensor placement strategy. It further demonstrated that the proposed shock wave-based sensing technique provided an effective alternative to vibration measurement, while requiring less space for sensor installation.

용존산소활량 측정용 지르코니아 갈바니 센서 (Zirconia galvani sensor for the measurement of oxygen activity)

  • 오영제
    • 센서학회지
    • /
    • 제18권6호
    • /
    • pp.441-448
    • /
    • 2009
  • Magnesia partially stabilized zirconia(Mg-PSZ) solid electrolytes for an improvement of thermal shock resistance, which is suitable for the measurement of oxygen activity in a molten steel, were prepared by post-thermal aging treatment. The steelmaking oxygen sensor elements were formed by an injection molding method, sintered at $1650^{\circ}C$, and then thermal aged ranged from 1250 to $1400^{\circ}C$. Sintered density and porosity were decreased as increasing the magnesia content in a zirconia-magnesia solid solution. Fractions of cubic phase to the synthesized Mg-PSZ solid electrolytes were ranged from 13.13 to 79.54.% after post-thermal aging treatment. Very dense microstructure without voids in the grains was obtained by the post-thermal aging process. Fine tetragonal phase crystallites precipitated on the cubic surface during post-thermal aging up to $1300^{\circ}C$ improve a thermal shock resistance and reappearance of electro motive force(EMF) curve.

탄환 충격파 측정용 방수 음향센서 개발 (Development of Waterproof Acoustic Sensor for Shockwave Measurement)

  • 허신;이덕규
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.318-322
    • /
    • 2019
  • In shooting training, an impact point identification system that uses the impact wave of the bullet to check the impact point in the target plate has been recently used. Acoustic sensors used in these systems must be able to detect shock waves of high sound pressure levels and be both waterproof and dustproof for rainy weather and dusty environments, respectively. In this study, membranes with excellent waterproof, dustproof, and sound transmitting characteristics were selected through a characteristics test; a protection cap was installed to install the selected materials. After coupling the produced protection cap to the acoustic sensor housing, the sensitivity and phase characteristics of the acoustic sensor were checked. Through the waterproof and dustproof test, the performances of its sensitivity and phase characteristics were confirmed. Finally, the normal shockwave of a 5.56 mm diameter bullet was measured using a shockwave detection signal collecting plate equipped with a prototype of the acoustic sensor at a 100 m firing range.

초유동 충격파관관 장치 및 측정수단 (Superfluid Shock Tube Facility and Measurement Methods)

  • 양형석
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.202-204
    • /
    • 2002
  • The supurfluid shock tube facility has been developed as a versatile tool for experimental research of low-temperature thermo-fluid dynamic phenomena The shock tube is designed to operate with the He II filled test section which is immersed in superfluid helium. The thermo-dynamic phenomena occurred in this facility are measured using pressure transducers, superconductive temperature sensor and visualization method. In this paper, the design and performance of the superfluid shock tube facility and the superconductive temperature sensor is presented.

  • PDF

군용 차량 주행 내충격 분석 (Analysis for Driving Shock Resistance of Military Vehicle)

  • 전종익;이종학;정의봉;강광희;최지호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.267-272
    • /
    • 2014
  • In this paper, we analyze the characteristics for the driving shock resistance of the military vehicle through the bump test. Prior to the experiment, theoretical analysis was performed by using the SRS(shock response spectrum) and VRS(vibration response spectrum) analysis method. And we estimated the characteristics for the driving shock resistance of the military vehicle. Bump test was performed using the acceleration sensor and the driving test at a different speed. We evaluated the characteristics for the driving shock resistance of the military vehicle based on the result. And predicted values were compared with the theoretical analysis. In addition, we evaluated the results of the theoretical prediction of the SRS and the VRS analysis. And we evaluate the suitability of the prediction method at military vehicle shock analysis.

  • PDF