• Title/Summary/Keyword: Shielding ratio

Search Result 146, Processing Time 0.029 seconds

Effects of shielding Gas Types on $CO_2$ Laser Weldability (보호가스에 따른 Tailored Blank 레이저 용접성 평가에 관한 연구)

  • 정봉근;유순영;박인수;이창희
    • Laser Solutions
    • /
    • v.1 no.1
    • /
    • pp.30-38
    • /
    • 1998
  • This study includes the efface of shielding gas types on $CO_2$ laser weldability of low carbon automotive galvanized steel. The types of shielding gas evaluated are He, $CO_2$, Ar, $N_2$, 50%Ar+50%$N_2$. The weld penetration, strength, formability(Erichsen test) of Laser weld are found to be strongly dependent upon the types of shielding gas used. Further, the maximum travel speed and flow rate to form a keyhole weld is also dependent upon types of shielding gas. The ability of shielding gas in removing plasma plume and thus increasing weld penetration is believed to be closely related with ionization/dissociation potential, which determine the period of plasma formation and disappearance. Further, thermal conductivity and reactivity of gas with molten pool also give strong effect on penetration and porosity formation which in turn affect on the formability and strength.

  • PDF

A SHIELDING EFFECTIVENESS of COATED CONDUCTIVE POLYMER for ELECTROMAGNETIC SHIELDING (전자파 차폐용 전도성 고분자 코팅재료의 차폐효율)

  • 최재옥;임윤석;장용무;서광석;구자윤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.624-627
    • /
    • 2000
  • The shielding effectiveness of materials is determined by measuring the ratio of the incident electromagnetic power which passes through the material under test. To measure the shielding effectiveness materials made by conductive polymer, the flanged coaxial transmission-line holder based in ASTM D4935-89, was fabricated. This apparatus has dynamic range between 95dB and 120dB in frequency range of 50Mhz-2Ghz. Furthermore, this system can be utilized to measure the shielding effectiveness of materials produced by conductive polymer and can be adapted for shielding materials design.

  • PDF

Shielding effects on a tall building from a row of low and medium rise buildings

  • Zu, G.B.;Lam, K.M.
    • Wind and Structures
    • /
    • v.27 no.6
    • /
    • pp.439-449
    • /
    • 2018
  • Wind loading of a tall building built amidst a group of buildings in urban environment is always greatly affected by shielding effects. Wind tunnel tests were carried out to assess the shielding provided by a row of low-rise or medium-rise buildings upstream a square-section tall building of height-to-breadth ratio 6. Mean and dynamic wind loads on the tall building were measured at different wind incidence angles and presented as interference factors (IFs). It is found that presence of a row of upstream buildings provides significant shielding to the tall building. At normal wind incidence, the mean along-wind loads and all components of fluctuating wind loads on the tall building are always reduced by shielding. Vortex shedding seems to still occur on the upper exposed part of the tall building but the vortex excitation levels are largely reduced. The degree of shielding is found to depend on a number of arrangement parameters of the row of upstream buildings. Empirical equations are proposed to quantify the shielding effect based on the wind tunnel data.

A Study on the Shielding Element Using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 차폐체 원소 평가)

  • Kim, Ki-Jeong;Shim, Jae-Goo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.269-274
    • /
    • 2017
  • In this research, we simulated the elementary star shielding ability using Monte Carlo simulation to apply medical radiation shielding sheet which can replace existing lead. In the selection of elements, mainly elements and metal elements having a large atomic number, which are known to have high shielding performance, recently, various composite materials have improved shielding performance, so that weight reduction, processability, In consideration of activity etc., 21 elements were selected. The simulation tools were utilized Monte Carlo method. As a result of simulating the shielding performance by each element, it was estimated that the shielding ratio is the highest at 98.82% and 98.44% for tungsten and gold.

Shielding effect model and Signal Switching in the multi-layer interconnects (다층 배선에서 차폐효과 모델 및 스위칭에 미치는 영향)

  • 진우진;어영선
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1145-1148
    • /
    • 1998
  • New capacitance modeling and transient analysis for multi-layer interconnects with shielding effect are presented. The upper layer capacitances with under-layer shielding lines are represented by introducing a filling factor η which can be defined as the ratio of upper-layer line length to the total under-layer line width. The upper-layer effective self capacitances considering two extreme cases which the underlayer metals are assumed as a ground or as a Vdd are modeled. The signal transient analysis with shielding effect model is performed.

  • PDF

The Shielding Effectiveness of Zn-Al Arc Thermal Metal Film Coated Cement-Mortar Using Copper Powder (Zn-Al 아크 금속용사 피막을 적용한 구리분말 혼입 시멘트 모르타르의 전자파 차폐 성능 평가)

  • Choi, Hyun-Jun;Choi, Hyun-Kuk;Kim, Hyeong-Cheol;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.124-125
    • /
    • 2017
  • In this study, the shielding effectiveness of the Zn-Al arc thermal metal film coated cement-mortar mixed with copper powder by reflection, absorption, multi-reflection loss in 2.25~2.65 GHz was reviewed. By enhancing the mixing ratio of copper powder, the shielding effectiveness by absorption and multi-reflection loss was increased, but shielding rate(%) based on 80 dB showed below 20%. The Zn-Al arc thermal metal film coated on specimen, the shielding rate increased 3.5 times by reflection loss.

  • PDF

The effect of shielding gases on the characteristics of super duplex weld metal (슈퍼 듀플렉스 용접부에 미치는 보호가스의 영향)

  • Hong, In-Pyo;Lee, Cheol-Hwan;Kim, Yu-Gi;Kim, Dae-Sun
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.209-211
    • /
    • 2005
  • Super duplex stainless steels have been used for offshore oil and gas piping systems which are subject to corrosion atmosphere, because they have excellent resistance to Stress Corrosion Cracking (SCC) and Pitting corrosion and high strength/weight ratio. Normally, the welding for duplex stainless steels has been peformed using GTAW with Ar shielding gas. However, in case of using Ar as shielding gas, the corrosion resistance at root weld metal will be deteriorated due to loss of nitrogen from weld deposit during welding. It is wellknown that the corrosion resistance of super duplex stainless can be restored by addition of nitrogen as shielding gas. In this study, we made super duplex welding with using several kinds of shielding and purging gases and investigated the relationship between shielding gas and corrosion resistance. Consequently, it was shown that corrosion resistance of weld deposit can be restored by addition of $N_{2}$ as shielding gas.

  • PDF

Weldability in Nd:YAG Laser of Sintered Material Depend on Shielding Gases (보호가스에 따른 소결체의 Nd:YAG 레이저 용접성)

  • Kim, Yong;Yang, Hyun-Seok;Park, Ki-Young;Lee, Kyoung-Don
    • Laser Solutions
    • /
    • v.10 no.4
    • /
    • pp.1-6
    • /
    • 2007
  • This study includes the effects of shielding gas types and flow rate on Nd:YAG Laser weldability of sintered material. The types of shielding gas were evaluated for He, Ar and N2. Bending strength, porosity rate, hardness and aspect ratio testing of laser weld are carried out to evaluated the weldability. As a results, Ar gas was showed the best welding strength even it has the most porosity content on weld metal, and depend on increases the gas flow rate, it was not only got deeper penetration depth but also showed higher bending strength. Therefore we could know that bending strength is not only affect the porosity content but also melting area.

  • PDF

Optimization of GTAW Parameters for Horizontal Welding of a STS316L Pipe (STS316L 강관의 수평자세 용접을 위한 GTAW 용접조건의 최적화)

  • Lee, Hyoung-Keun;Bang, Kyoung-Sik
    • Journal of Welding and Joining
    • /
    • v.33 no.5
    • /
    • pp.47-52
    • /
    • 2015
  • In this study, it was tried to analyze the effects of welding parameters on the weld penetration and aspect ratio when a STS316L pipe was welded in a horizontal position by GTAW. Experiments were systematically designed using a L18 orthogonal array, and the effects of welding parameters were statistically analyzed by ANOVA(Analysis of Variance). The shielding gas type has the largest effect on both the penetration and aspect ratio. The welding current type and shielding gas flow rate have a little effect on the penetration, whereas the electrode tip angle has a little effect on the aspect ratio. When welded at a selected welding condition, which is composed of He shielding gas, pulse current of 300/45 A, electrode tip angle of 90o, and shielding gas flow rate of 30 l/min, the estimated interval at least 95 % confidence was $1.99{\pm}0.18mm$ for the penetration and $0.31{\pm}0.04$ for the aspect ratio. From the confirmation experiments, the average penetration and aspect ratio were well agreed with the estimation as 1.96 mm and 0.30, respectively. Additionally, the effects of the welding speed and welding current on the penetration and aspect ratio were experimented and analyzed by linear regression. The penetration was linearly increased with the decrease of the welding speed and with the increase of the welding current, but the aspect ratio showed a tendency to a little decrease with the increase of both the welding speed and current.

Some Measurements of Scattered Radiation from Various Radiation Shielding Materials (방사선(放射線) 차폐물질(遮蔽物質)에서 발생(發生)하는 산란선(散亂線)의 측정(測定))

  • Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.15-22
    • /
    • 1981
  • Half value layer(radiation energy) of $90^{\circ}$ scattered radiation from various radiation shielding materials was measured at 1 m distance from the central ray of the primary beam. Scattered radiation was measured from 100 to 200 kVp for 0-2.0mm Cu+1.0mm Al added filter in the primary beam for a deep therapeutic unit, the obtained results were as follows: 1. The ratio of scattered radiation to primary radiation was increased by using lighter filter. 2. The ratio of scattered radiation to primary radiation was decreased by using heavier filter. 3. The ratio of scattered radiation to primary radiation was independent of tube voltage. 4. The scattered radiation of high energy was produced, when the effective atomic number and density of shielding material were high.

  • PDF